Danfoss EHS Installation guide

Installation Guide
Electronic Speed Control
Speed Control EHS Code no. 155U3905 Supply: 11-30 V DC
Type EHS
Montage Installation
Tilslutning Connection Anschluss Raccordement
Monteringssokkel EHB Mounting base EHB Montagesockel EHB Socle de montage EHB
Terminalnumre Terminal numbers
T
Terminalnummern Numéros de bornes
Made in Denmark
Speed Control EHS Code no. 155U3905 Supply: 11-30 V DC
Made in Denmark
For at opnå den bedste funktion i Deres system anbefaler Danfoss, at De anvender EHS sammen med PVEH.
Speed Control EHS Code no. 155U3905 Supply: 11-30 V DC
Made in Denmark
To obtain the best function in your system Danfoss recommends that you use EHS together with PVEH.
Nødstop Emergency stop
E
Notschalter Arrêt d’urgence
Udtag fra fejlovervågning Branch circuit for fault monitoring
F
Anzapfung von der Fehlerüberwachung Sortie du signal défaut
Um die beste Funktion in Ihrem System zu erreichen empehlt Danfoss, dass Sie EHS zusammen mit PVEH verwenden.
An d’assurer le meilleur fonctionnement de votre système Danfoss propose d’utiliser l’EHS avec le PVEH.
© Danfoss, 2014-03 520L0508 • Rev BB • Mar 2014 1
Kompensering for lækage i motor med potentiometer II Motor leakage compensation with potentiometer II Leckölausgleich im Motor mit dem Potentiometer II Compensation des fuites avec potentiomètre II
*1 Pumpen startes Pump “on” Pumpe »ein« Démarrer la pompe
*2 Terminal 4 afbrydes Terminal 4 disconnected Klemme 4 oen La borne 4 ouvert
Speed Control EHS Code no. 155U3905 Supply: 11-30 V DC
*3 f > 0.1 × f
max.
*4 n = 0 r/min Pot. II
n > 0 r/min Pot. II
n ≈ 0 r/min → OK
*5 Terminal 4 tilsluttes Connect terminal 4 Klemme 4 anschliessen Raccorder la borne 4
Justering af maks. frekvens (f
max
Adjustment of max. frequence (f Einstellung von max. Frequenz (f Réglage e la fréquence maxi (f
max
D
) med potentiometer I
) with potentiometer I
max
) mit dem Potentiometer I
max
) avec potentiomètre I
Dødbånd Dead band Totband Zone morte
Made in Denmark
Ændring af input-reference Alteration of input reference Änderung der Eingangs-Referenz Modication de la référence d’entrée
Anvendes kun hvis input-reference 0,5 × UDC ± min. 1 V ikke kan overholdes.
To be used only if the input reference 0.5 × U
± min. 1 V
DC
cannot be observed.
Speed Control EHS Code no. 155U3905 Supply: 11-30 V DC
Speed Control EHS Code no. 155U3905 Supply: 11-30 V DC
Eingangs-Referenz 0,5 × UDC ± min. 1 V nicht ein­gehalten werden kann.
Wird nur verwendet, wenn die
*6 f = f f *7 U1 < ––– × 0.25 × UDC Pot. I f
in
f
max
in
A utiliser seulement si la
Made in Denmark
référence d’entré 0,5 × UDC ± min. 1 V ne peut
in
pas être observée. U1 > ––– × 0.25 × UDC Pot. I f
f
max
Made in Denmark
in
U1 = ––– × 0.25 × UDC OK f
2 520L0508 • Rev BB • Mar 2014 © Danfoss, 2014-03
max
Loading...