Data sheet
Refrigeration controller
EETc 11, 12, 21, 22 and EETa 2W, 3W
The EET Series is the next generation of Electronic Thermostats which is a direct replacement of
the Mechanical Thermostat (and timer) and Danfoss ETC series. It comes in two variants: EETc (Enhanced Electronic Thermostat, compact) which has one and two output model options for controlling compressor and fan/defrost heater and EETa (Enhanced Electronic Thermostat, advanced) which has two and three output model options for controlling compressor, fan, defrost heater or light.
With the EETc and the EETa, we continue building on the electronification legacy by bringing a high number of new features and capabilities
to increase performance and flexibility, while keeping the familiar form factor and installation method.
Features |
• Moisture protected design for installability |
|
inside the cold space area |
|
• Similar dimensions and installation method |
|
as ETC series and Mech Thermostat for easy |
|
transition (applicable for EETc) |
|
• Wide Voltage Power Support (110 – 230 V) |
|
(applicable for EETa) |
|
• Configurable auxiliary inputs and outputs to |
|
control fan, defrost heater and light |
|
• Alarms, fan & light control, compressor |
|
management using door sensor |
|
• Supports multiple sensor types: NTC 5K, NTC |
|
10K, PTC 990 |
|
• Zero cross technology for longer relay life |
|
• Mass programmable at production site with |
|
direct programming key access |
•Compressor protection from voltage fluctuations, spikes and surges
•Advanced fan control
•Multiple defrost methods to choose from
•Condenser overheat protection
•Economy mode (Eco mode) to give more energy saving potential during night and long hours of no use. EETa also supports Holiday mode, which allows longer than a day period of auto temperature offset
•Dual defrost control (only EETa)
•Quick factory test mode to check if inputs/ outputs are functioning
•High and low temperature alarm indication
•Safety/Emergency mode in case of sensor and potentiometer failure
© Danfoss | DCS (vt) | 2020.10 |
AI355927147717en-000102 |
Data sheet | Refrigeration controller, EETc 11, 12, 21, 22 and EETa 2W, 3W
Applications |
Applications supported by the EETc: |
Applications supported by the EETa: |
|||
|
• |
Glass door merchandisers |
• |
Glass door merchandisers |
|
|
• |
Beverage coolers |
• Commercial freezers and refrigerators |
||
|
• Commercial freezers and refrigerators |
• |
Preparation tables |
||
|
• |
Preparation tables |
• |
Dual compressor refrigerators |
|
|
|
|
• Anti-freeze applications requiring auto heat |
||
|
|
|
|
control |
|
|
|
|
• Applications requiring dual defrost control |
||
|
|
|
|
||
Variants |
EETc: |
EETa: |
|
||
|
• EETc 11: 1 output, 120 V |
• EETa 2W: 2 outputs, wide voltage (120 – 230 V) |
|||
|
• EETc 12: 1 output, 230 V |
• EETa 3W: 3 outputs, wide voltage (120 – 230 V) |
|||
|
• EETc 21: 2 outputs, 120 V |
|
|
|
|
|
• EETc 22: 2 outputs, 230 V |
|
|
|
|
|
|
|
|
|
|
Facts |
Variant differences |
|
|
|
|
|
HW differences between EETc and EETa: |
|
|
|
|
|
|
|
|
|
|
|
|
Features |
EETc |
|
EETa |
|
|
|
|
|
|
|
|
Sensor inputs |
2 |
|
3 |
|
|
|
|
|
|
|
|
Wide voltage power module |
No |
|
Yes |
|
|
|
|
|
|
|
|
Visible LED indication |
Power |
|
Power, Error |
|
|
|
|
|
|
|
|
Temperature sensors supported |
NTC 5K, NTC 10K |
NTC 5K, NTC 10K, PTC |
|
|
|
|
|
|
|
|
|
Output options |
1 & 2 Relay |
|
2 & 3 Relay |
|
|
|
|
|
|
|
SW differences between EETc and EETa: |
|
|
|
|
|
|
|
|
|
|
|
|
Features |
EETc |
|
EETa |
|
|
|
|
|
|
|
|
Onsite Parameter Programming/ |
Koolkey with external power |
Koolkey with powered controller |
|
|
|
Production Programming capability |
|
|
|
|
|
|
|
|
|
|
|
Onsite firmware update capability |
No |
|
Yes |
|
|
|
|
|
|
|
|
Eco mode |
Yes |
|
Yes |
|
|
|
|
|
|
|
|
Holiday mode |
No |
|
Yes |
|
|
|
|
|
|
|
|
Light Control |
No |
|
Yes |
|
|
|
|
|
|
|
|
Dual defrost |
No |
|
Yes |
|
|
|
|
|
|
|
|
Dual compressor control |
No |
|
Yes |
|
|
|
|
|
|
|
|
Anti-freeze function |
No |
|
Yes |
|
|
|
|
|
|
2 | AI354138789910en-000101 |
© Danfoss | DCS (vt) | 2020.10 |