The EET Series is the next generation of Electronic
Thermostats which is a direct replacement of
the Mechanical Thermostat (and timer) and
Danfoss ETC series. It comes in two variants:
EETc (Enhanced Electronic Thermostat, compact)
which has one and two output model options for
controlling compressor and fan/defrost heater
and EETa (Enhanced Electronic Thermostat,
advanced) which has two and three output
model options for controlling compressor, fan,
defrost heater or light.
With the EETc and the EETa, we continue building
on the electronification legacy by bringing a
high number of new features and capabilities
to increase performance and flexibility, while
keeping the familiar form factor and installation
method.
Features• Moisture protected design for installability
inside the cold space area
• Similar dimensions and installation method
as ETC series and Mech Thermostat for easy
transition (applicable for EETc)
• Wide Voltage Power Support (110 – 230 V)
(applicable for EETa)
• Configurable auxiliary inputs and outputs to
control fan, defrost heater and light
• Alarms, fan & light control, compressor
management using door sensor
• Mass programmable at production site with
direct programming key access
• Compressor protection from voltage
fluctuations, spikes and surges
• Advanced fan control
• Multiple defrost methods to choose from
• Condenser overheat protection
• Economy mode (Eco mode) to give more
energy saving potential during night and long
hours of no use. EETa also supports Holiday
mode, which allows longer than a day period
of auto temperature offset
• Dual defrost control (only EETa)
• Quick factory test mode to check if inputs/
outputs are functioning
• High and low temperature alarm indication
• Safety/Emergency mode in case of sensor and
potentiometer failure
Two relay version: Compressor relay + Aux relay (Defrost heater / Evaporator
fan)
Cold Space Installability
III - 115 V supply version - (UL recognized)
R290/R600a end-use applications employing in accordance to
EN/IEC 60335-2-24, annex CC and EN/IEC 60335-2-89, annex BB
Glow wire according to EN/IEC 60335-1
IEC/EN 60730
UL60730
NSF
CQC
EAC
Ukraine
Data sheet | Refrigeration controller, EETc 11, 12, 21, 22 and EETa 2W, 3W
Electronic temperature control, type EETa 2W and EETa 3W:
Product specificationEETa 2WEETa 3W
Purpose of controlOperating temperature sensing control suitable for incorporation into
Construction of controlIncorporated control
Power supply100 – 240 V AC +/- 10%, 50/60 Hz, Non isolated
Relay ratingsDO1: 16 A (16 FLA / 72LRA)
Product dimensionLength: 83.5 mm
Temperature controlPotentiometer with spindle
Number of inputs3 (1 Analogue, 2 Analogue / Digital)
Supported sensor typesNTC 5K (Beta value 3980 @ 25/100 °C)
Measuring accurancy±1 K below -35 °C
Measurement range NTC 5K: -40 – +80 °C
Output configurationDO1: Compressor
Input connector typePlug and header type
Output connector typeTab Connector
CommunicationTTL (MODBUS)
Operating temperature range-25 – +50 °C
Humidity range93% RH, Condensing
InstallationSpindle mounted
Relay switchingZero cross technology (all relays)
Surge protection 4 KV
Approvals
(In process)
commercial air-conditioning and refrigeration applications
DO2: 8A (2FLA /12LRA)
Width: 43.5 mm
Height: 30.5 mm
NTC 10K (Beta value 3980 @25/100 °C)
PTC 990 ohms @ 25 °C (EKS111)
±0.5 K between -35 – +25 °C
±1 K above +25 °C
NTC 10K: -40 – +80 °C
PTC 990: -55 – +100 °C
DO2: Def. Heater/Fan/Light/Second
comp/Alarm
Cold space installability
R290/R600a end-use applications employing in accordance to
EN/IEC 60335-2-24, annex CC and EN/IEC 60335-2-89, annex BB
Glow wire according to EN/IEC 60335-1
IEC/EN 60730
UL60730
NSF
CQC
EAC
Ukraine
DO1: 16 A (16 FLA / 72LRA)
DO2: 8 A (2FLA /12LRA)
DO3: 5 A (2FLA /12 LRA)
DO1: Compressor
DO2 and DO3: Def. Heater/Fan/Light/
Second comp/Alarm
Data sheet | Refrigeration controller, EETc 11, 12, 21, 22 and EETa 2W, 3W
s
80G404
s
80G405
s
s
7
Connections
EETc11, EETc12
EETc21, EETc22
Warnings:
1. Do not fit power supply wiring and signal
wiring (probes/sensors and digital inputs) in
the same raceways or ducts.
2. Separate as much as possible the probe and
digital input signal cables from the cables
carrying inductive loads and power cables to
avoid possible electromagnetic disturbance.
1
2
3
DO1
4
1
DO2
2
3
DO1
4
120 / 230 V AC120 / 230 V AC
N
L
N
L
Open
Compressor
Def. Heater/
Fan
Compressor
3. Suitably fasten the output connection cables
to avoid any unintentional contact.
4. The electrical connections must only be
completed by a qualified electrician.
5. The customer must only use the product in
the manner described in the documentation
relating to the installation and product
application.
-40 – +80 °C, PVC Standard, NTC 10K, Cabinet Sensor
S1, 1000 mm150080N0300
S1, 1500 mm150080N0301
S1, 2000 mm150080N0302
S1, 3000 mm150080N0303
-40 – +80 °C, PVC Standard NTC 10K, Defrost Sensor
S2, 1500 mm, 2 Blue Stripes150080N0304
S2, 2000 mm, 2 Blue Stripes150080N0305
S2, 3000 mm, 2 Blue Stripes150080N0306
-40 – +80 °C, PVC Standard, NTC 10K, Condenser Sensor
S3, 1000 mm, 1 Blue Stripe150080N0307
S3, 3000 mm, 1 Blue Stripe150080N0308
Magnetic door sensor
2000 mm1500 80 N0 311
3000 mm150080N0312
Cable door sensor
2000 mm150080N0313
4000 mm150080 N0314
Hand knob
Black480077F8562
Washer
Black with white print 0-9480077F8577
Power plug*
4-pole with screw50080 N0310
6-pole with screw54080G3357
Programming
Please contact your nearest sales representative for more information.
* The connectors are rated for 28 Amps max.