Technical Information (TI)............................................................................................................................................................. 4
Data Sheet (DS)................................................................................................................................................................................. 4
PLUS+1® GUIDE User Manual....................................................................................................................................................... 4
Latest version of technical literature.........................................................................................................................................4
DM1x00 Series Displays description..........................................................................................................................................8
Model variants.................................................................................................................................................................................10
Model code.......................................................................................................................................................................................10
Model code key...............................................................................................................................................................................10
Related products............................................................................................................................................................................11
CAN shield and analog input.....................................................................................................................................................16
Digital output.................................................................................................................................................................................. 16
CAN communication.....................................................................................................................................................................16
USB communication..................................................................................................................................................................... 17
Video power.....................................................................................................................................................................................17
Officially validated digital camera formats...........................................................................................................................17
Officially validated analog camera formats..........................................................................................................................18
Supply voltage/maximum current ratings........................................................................................................................... 20
DM1x00 Series Displays dimensions.......................................................................................................................................22
Standard Mount..............................................................................................................................................................................25
Visibility and viewing radius...................................................................................................................................................... 27
DM1x00 Series PLUS+1® Mobile Machine DisplaysTechnical InformationBC313277849405
DM1x00 Series PLUS+1® Mobile Machine DisplaysData SheetAI304864913574
PLUS+1® GUIDE SoftwareUser ManualAQ152886483724
Technical Information (TI)
A TI is comprehensive information for engineering and service personnel to reference.
Data Sheet (DS)
A DS is summarized information and parameters that are unique to a specific model.
PLUS+1® GUIDE User Manual
The Operation Manual (OM) details information regarding the PLUS+1® GUIDE tool used in building PLUS
+1® applications. This OM covers the following broad topics:
How to use the PLUS+1® GUIDE graphical application development tool to create machine
•
applications
How to configure module input and output parameters
•
How to download PLUS+1® GUIDE applications to target PLUS+1® hardware modules
•
How to upload and download tuning parameters
•
How to use the PLUS+1® Service Tool
•
Latest version of technical literature
Comprehensive technical literature is online at www.danfoss.com
The OEM of a machine or vehicle in which Danfoss products are installed has the full responsibility for all
consequences that might occur. Danfoss has no responsibility for any consequences, direct or indirect,
caused by failures or malfunctions.
Danfoss has no responsibility for any accidents caused by incorrectly mounted or maintained
•
equipment.
Danfoss does not assume any responsibility for Danfoss products being incorrectly applied or the
•
system being programmed in a manner that jeopardizes safety.
All safety critical systems shall include an emergency stop to switch off the main supply voltage for
•
the outputs of the electronic control system. All safety critical components shall be installed in such a
way that the main supply voltage can be switched off at any time. The emergency stop must be easily
accessible to the operator.
Safety statements
Warning
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders.
Improperly protected power input lines against over current conditions may cause damage to the
hardware. Properly protect all power input lines against over-current conditions. To protect against
unintended movement, secure the machine.
Warning
At high ambient temperatures the metal housing can become hotter than 70℃. Please use caution when
touching the metal housing of the display
Caution
Unused pins on mating connectors may cause intermittent product performance or premature failure. Be
sure to plug all pins on mating connectors.
Display operation guidelines
•
Disconnect your machine's battery power before connecting power and signal cables to the display.
•
Before doing any electrical welding on your machine, disconnect all power and signal cables
connected to the display.
•
Do not exceed the display power supply voltage ratings. Using higher voltages may damage the
display and can create a fire or electrical shock hazard.
•
Do not use or store the display where flammable gases or chemicals are present. Using or storing the
display where flammable gases or chemicals are present may cause an explosion.
•
Software configures the keypad buttons on the display. Do not use these buttons to implement
critical safety features. Use separate mechanical switches to implement critical safety features such as
emergency stops.
•
Design systems that use the display so that a communication error or failure between the display and
other units cannot cause a malfunction that might injure people or damage material.
•
The protective glass over the display screen will break if hit with a hard or heavy object. Install the
display to reduce the possibility of it being hit by hard or heavy objects.
•
Storing or operating a display in an environment that exceeds the display specified temperature or
humidity rating may damage the display.
Always clean the display with a soft, damp cloth. Use a mild dishwashing detergent as needed. To
avoid scratching and discoloring the display, do not use abrasive pads, scouring powders, or solvents
such as alcohol, benzene, or paint thinner.
•
Keep ambient light sensor area clean and uncovered for best operation.
•
Danfoss graphical displays are not user serviceable. Return the display to the factory in case of failure.
Protect wires from mechanical abuse, run wires in flexible metal or plastic conduits.
•
Use 85˚ C (185˚ F) wire with abrasion resistant insulation and 105˚ C (221˚ F) wire should be
considered near hot surfaces.
•
Use a wire size that is appropriate for the module connector.
•
Separate high current wires such as solenoids, lights, alternators or fuel pumps from sensor and other
noise-sensitive input wires.
•
Run wires along the inside of, or close to, metal machine surfaces where possible, this simulates a
shield which will minimize the effects of EMI/RFI radiation.
•
Do not run wires near sharp metal corners, consider running wires through a grommet when
rounding a corner.
•
Do not run wires near hot machine members.
•
Provide strain relief for all wires.
•
Avoid running wires near moving or vibrating components.
•
Avoid long, unsupported wire spans.
•
Ground electronic modules to a dedicated conductor of sufficient size that is connected to the
battery (-).
•
Power the sensors and valve drive circuits by their dedicated wired power sources and ground
returns.
•
Twist sensor lines about one turn every 10 cm (4 in).
•
Use wire harness anchors that will allow wires to float with respect to the machine rather than rigid
anchors.
Machine welding guidelines
Warning
High voltage from power and signal cables may cause fire or electrical shock, and cause an explosion if
flammable gasses or chemicals are present.
Disconnect all power and signal cables connected to the electronic component before performing any
electrical welding on a machine.
The following is recommended when welding on a machine equipped with electronic components:
•
Turn the engine off.
•
Remove electronic components from the machine before any arc welding.
•
Disconnect the negative battery cable from the battery.
•
Do not use electrical components to ground the welder.
•
Clamp the ground cable for the welder to the component that will be welded as close as possible to
the weld.
The Danfoss DM1x00 display series bring modern appearance and performance to mobile machine
markets with two display platforms, expanding the PLUS+1® family.
The DM1x00 series was developed for best operator viewability with its high brightness, optical bonding,
anti-glare, anti-reflection, oleophobic coating and wide viewing angles. It is equipped with an
outstanding dual core 800 MHz i.MX6 processor and 4GB flash memory delivering high performance.
Ruggedized for mobile machine markets, it is built to withstand harsh operating environments with its
IP66 and IP67 rating and the water-resistant screen allowing for multi-touch while wearing gloves.
The integrated file viewer and media player provides view of documents and media files on the run using
the audio line out to connect to the vehicle speaker system.
To meet specific needs, the DM1x00 includes two different screen sizes (10.1” and 12.1”) with optional
multi-touch and two button pad configurations with programmable back-lights and tactile feedback.
WiFi and Bluetooth® provide wireless channels for servicing the machine remotely.
Features
•
4 CAN ports
•
RS232 and USB 2.0 high-speed
•
Ethernet
•
Bluetooth® and WiFi, GNSS (optional)
•
4 Camera inputs (Up to 2 displayed at one time)
•
Audio line out
•
Sensor supply out
•
Optional keypad with either 8 buttons on each side (16 total) or 8 buttons plus navigation panel (16
total)
•
Backlit buttons
•
Touch screen (optional)
•
Optical signal (2 RGB LEDs)
•
Integrated ambient light sensor for automatically adjusting brightness to lighting conditions
•
Ignition input
•
Wake up over input
•
Dual core 800 MHz i.MX6
4 GB Flash memory
‒
•
Media player and File viewer (PDF, JPG, MP3, MP4)
•
PLUS+1® GUIDE programmable
•
Real Time Clock (RTC)
•
Rugged IP66 and IP67 rating
•
2 Integrated DEUTSCH connectors
•
Fast Start-up Time (less than 5 seconds)
•
RAM® or Bracket (optional) mount (portrait or landscape)
•
Integrated accelerometer for auto-adjusting between screen orientations
•
32 MB App Log
PLUS+1® GUIDE
PLUS+1® GUIDE (Graphical User Integrated Development Environment) is a complete toolbox that
generates downloadable applications for all programmable PLUS+1® Compliant products.
A screen editor allows easy development of applications by programmers without formal software
development training. The expertise from a software engineer is not needed to find your way around in
PLUS+1® GUIDE.
Screen Size10.1Inch
Resolution1280 x 800Pixels
Brightness900cd/m2Value includes cover glass
Contrast Ratio500:1
Viewing Angle± 85Degreevertical and horizontal
Color Depth24Bits8 bits per color
DM1200 LCD 12.1" screen
Description.Value.Unit.Notes.
Screen Size12.1Inch
Resolution1280 x 800Pixels
Brightness900cd/m2Value includes cover glass
Contrast Ratio500:1
Viewing Angle± 85Degreevertical and horizontal
Color Depth24Bits8 bits per color
Danfoss | October 2021BC313277849405en-000204 | 11
Technical Information
PLUS+1 DM1x00 Series Displays
Input/output types and specifications
Specifications
Characteristics/certifications
Processor
RAM
FRAM
Supply voltage
Connector
Size
Aspect ratio
Resolution
Brightness
Contrast ratio
Viewing angle
Color depth
IP rating
Operating temperature
Storage temperature
Weight
Each PLUS+1® Module input pin supports one of the above functional types. For pins with multiple
functions, input configurations are user programmable using PLUS+1® GUIDE templates.
When using inputs in digital mode, it is advised to use the software selectable pull-up or pull-down
resistors.
error
Non-linearitymV——±8.5—
Input impedancekΩ232233234No pull up or pull down
Input impedance (5V/GND) kΩ13.914.114.3Pull up or pull down
Input impedance (2.5V)kΩ7.17.37.4Pull up and pull down
High range
DescriptionUnitMinimumTypicalMaximumComment
Minimum discernible
voltage
Maximum discernible
voltage
ResolutionmV—9.5——
Worst case offset and gain
error
Non-linearitymV——±56.8—
Input impedancekΩ109.1109.3109.5No pull up or pull down
Input impedance (5V/GND) kΩ13.013.213.4Pull up or pull down (Vin <
Pull up and pull down input
impedance (2.5V)
V—
V5.695.785.88—
V——±0.14V
V—
V37.938.839.7—
V——0.95V
kΩ6.97.07.1Pull up and pull down (Vin
—
—
0.03—
0.16—
= 5.78 V
Measure
= 38.8 V
Measure
(Vin < 5.7 V)
5.7 V)
< 5.7 V)
Multifunction inputs
Low range analog
DescriptionUnitMinimumTypicalMaximumComment
Minimum discernible
voltage
Maximum discernible
voltage
ResolutionmV—0.1——
Worst case offset and gain
error
Non-linearitymV——±26—
Input impedancekΩ232233234No pull up or pull down
Input impedance (5V/GND) kΩ13.914.114.3Pull up or pull down
Input impedance (2.5V)kΩ7.17.37.4Pull up and pull down
Danfoss | October 2021BC313277849405en-000204 | 13
mV——13—
mV379404430—
mV——±0.6V
Measure
= 404 mV
Technical Information
PLUS+1 DM1x00 Series Displays
Input/output types and specifications
Middle range analog
DescriptionUnitMinimumTypicalMaximumComment
Minimum discernible
voltage
Maximum discernible
voltage
ResolutionmV—1.4——
Worst case offset and gain
error
Non-linearitymV——±8.5—
Input impedancekΩ232233234No pull up or pull down
Input impedance (5V/GND) kΩ13.914.114.3Pull up or pull down
Input impedance (2.5V)kΩ7.17.37.4Pull up and pull down
High range analog
DescriptionUnitMinimumTypicalMaximumComment
Minimum discernible
voltage
Maximum discernible
voltage
ResolutionmV—9.5——
Worst case offset and gain
error
Non-linearitymV——±56.8—
Input impedancekΩ109.1109.3109.5No pull up or pull down
Input impedance (5V/GND) kΩ13.013.213.4Pull up or pull down (Vin <
Input impedance (2.5V)kΩ6.97.07.1Pull up and pull down (Vin
V——0.03—
V5.695.785.88—
V——±0.14V
V——0.16—
V37.938.839.7—
V——±0.95V
(Vin < 5.7 V)
5.7 V)
< 5.7 V)
Measure
Measure
= 5.78 V
= 38.8 V
Low range frequency (PPU)
DescriptionUnitMinimumTypicalMaximumComment
RangeHz0—10000In steps of 1 Hz
Rising voltage thresholdmV——314
Falling voltage thresholdmV55——
Input impedancekΩ232233234No pull up or pull down
Input impedance (5V/GND) kΩ13.914.114.3Pull up or pull down
Input impedance (2.5V)kΩ7.17.37.4Pull up and pull down
Middle range frequency (PPU)
DescriptionUnitMinimumTypicalMaximumComment
RangeHz0—10000In steps of 1 Hz
Range (phase and quad)Hz0—5000In steps of 1 Hz
Rising voltage thresholdV——4.25Voltage required for
Falling voltage thresholdV0.97——Voltage required for
Due to the display nature of the TFT-LCD screen, the optimal viewing angle for the DM1x00 series
displays are at a maximum radius of 85° from either side of the screen.
Optimal viewing angle
Display faulty application recovery
The boot loader is always executed when the unit is powered. The boot loader checks if the application
has the completely downloaded flag set and in that case starts to execute it after a delay of 200 ms. The
delay gives an opportunity for the PLUS+1® Service Tool to prevent the call to the application. This allows
a non functional application to be replaced by the boot loader. This recovery function is activated by the
Communication > Recover ECU menu in the PLUS+1® Service Tool.
Cleaning
Do not pressure wash. Clean using a dry, soft, lint-free cloth, such as a micro-fiber cloth.
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 2080 6201
Products we offer:
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Cartridge valves
•
DCV directional control
•
valves
Electric converters
•
Electric machines
•
Electric motors
•
Gear motors
•
Gear pumps
•
Hydraulic integrated
•
circuits (HICs)
Hydrostatic motors
•
Hydrostatic pumps
•
Orbital motors
•
PLUS+1® controllers
•
PLUS+1® displays
•
PLUS+1® joysticks and
•
pedals
PLUS+1® operator
•
interfaces
PLUS+1® sensors
•
PLUS+1® software
•
PLUS+1® software services,
•
support and training
Position controls and
•
sensors
PVG proportional valves
•
Steering components and
•
systems
Telematics
•
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electric components. We specialize in providing state-of-the-art technology and solutions
that excel in the harsh operating conditions of the mobile off-highway market as well as the
marine sector. Building on our extensive applications expertise, we work closely with you to
ensure exceptional performance for a broad range of applications. We help you and other
customers around the world speed up system development, reduce costs and bring vehicles
and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile
electrification.
Go to www.danfoss.com for further product information.
We offer you expert worldwide support for ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also
provide you with comprehensive global service for all of our components.
Local address:
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.