Datasheets
DLE6.5CN Energy-optimized
LBP/MBP R290 115-127V 60Hz
General
Code number 102H3792
Code number (pre-assembled CSIR start equipment) 102H3793
Approvals UL984
Compressors on pallet 100
Compressors on pallet (with CSIR start equipment) 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F – -31 to 45
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 131 (149)
Max. winding temperature continuous (short) °F – 257 (275)
Application
DLE6.5CN
SUCTION
Red stripe
Approvals
Barcode on white background
Green background
Country of origin or manufacturer
R290
serial number
3792
Made by Secop
DLE6.5CN
115-127V-60Hz
1PH
THERMALLY
PROTECTED
102H
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – F2F2–
100°F – – – F
110°F – – – F
Remarks on application: For evaporation temperatures higher than 32 °F do not run
compressor at condensing temperatures higher 122 °F in steady state operation.
Motor
Motor type CSIR/RSIR/RSCR
LRA (rated after 4 sec. UL984), HST | LST A 22.8 16.7
Cut in Current, HST | LST A 22.8 29.0
Resistance, main | start winding (77°F) Ω 2.5 5.0
Design
Displacement cu.in 0.40
Oil quantity (type) .oz. 7.8 (polyolester)
Maximum refrigerant charge oz. 5.3
Free gas volume in compressor .oz. 44.8
Weight without electrical equipment lbs. 18.7
Dimensions
Height inch A 6.90
Suction connector location, I.D. in. | angle C 0.320-0.327 | 18°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 60°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 25°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
2F2
B 6.64
B1 –
B2 –
S = Static cooling normally sufcient
O = Oil cooling
= Fan cooling 1.5 m/s
F
1
(compressor compartment temperature
equal to ambient temperature)
–
F2 = Fan cooling 3.0 m/s necessary
–
SG = Suction gas cooling normally sufcent
– = not applicable in this area
DEHC.ED.100.B1.22
© Danfoss | DCS (CC) | 2015.10 | 1

ASHRAE LBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in BTU/h 722 984 1188 1282 1631 2048 2238 2551 3156 3291 3881 3961 4294
Power cons. in W 191 221 242 251 281 311 323 341 372 378 403 406 419
Current cons. in A 2.83 2.97 3.09 3.14 3.33 3.55 3.63 3.77 4.02 4.07 4.27 4.30 4.40
EER in BTU/Wh 3.78 4.46 4.91 5.11 5.81 6.59 6.92 7.47 8.48 8.7 9.63 9.75 10.3
ASHRAE MBP/HBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in BTU/h 645 880 1061 1145 1456 1827 1996 2274 2810 2930 3452 3522 3817
Power cons. in W 189 219 239 248 278 308 320 338 368 374 398 401 413
Current cons. in A 2.83 2.97 3.09 3.14 3.33 3.55 3.63 3.77 4.02 4.07 4.27 4.30 4.40
EER in BTU/Wh 3.41 4.02 4.43 4.61 5.24 5.94 6.24 6.73 7.64 7.84 8.67 8.78 9.23
EN 12900 LBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 223 295 353 380 479 598 651 740 909 946 1109 1131 1222
Power cons. in W 195 220 236 243 267 291 300 314 337 342 361 363 373
Current cons. in A 2.81 2.92 3.00 3.04 3.18 3.33 3.39 3.49 3.65 3.69 3.82 3.84 3.91
COP in W/W 1.14 1.35 1.49 1.56 1.79 2.06 2.17 2.35 2.69 2.77 3.07 3.11 3.28
EN 12900 MBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 204 272 325 350 443 553 604 686 844 879 1033 1053 1139
Power cons. in W 198 224 243 251 277 303 313 329 356 361 382 385 396
Current cons. in A 2.82 2.94 3.03 3.08 3.23 3.40 3.47 3.58 3.76 3.8 3.96 3.98 4.06
COP in W/W 1.03 1.21 1.34 1.40 1.60 1.83 1.93 2.08 2.37 2.44 2.70 2.73 2.88
Accessories for DLE6.5CN Figure Code number Test conditions
ePTC starting device 1/4 in. spade connectors a1 103N0058 *
)
Condensing temperature 104°F 113°F
Starting relay 1/4 in. spade connectors a2 117U7013 Ambient temperature 90°F 90°F
Start. capacitor 240 µF 1/4 in. spade connectors c 117U5023 Suction gas temperature 68°F 68°F
Cover b 103N0492 Liquid temperature no subcooling
EN 12900
LBP MBP
ASHRAE
LBP MBP
130°F 130°F
90°F 90°F
90°F 95°F
90°F 115°F
Cord relief d 103N1010
)
Remarks: RSIR and RSCR option available in 4th quarter 2015 Mounting accessories Code number
*
Bolt joint for one comp. Ø: 3/4 in. 118-1949
Bolt joint for one comp. Ø: 5/8 in. 118-1946
Snap-on for one comp. Ø: 5/8 in. 118-1947
2 | © Danfoss | DCS (CC) | 2015.10
DEHC.ED.100.B1.22