Danfoss DLE4.8CN Data sheet

Datasheets
DLE4.8CN Energy-optimized LBP/MBP R290 115-127V 60Hz
General
Code number 102H3582 Code number (pre-assembled CSIR start equipment) 102H3583 Approvals UL984 Compressors on pallet 100 Compressors on pallet (with CSIR start equipment) 80
Application
Application LBP/MBP Frequency Hz 50 60 Evaporating temperature °F -31 to 45 Voltage range V 95 - 135 Max. condensing temperature continuous (short) °F 131 (149) Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60 Application 90°F S S – 100°F S S – 110°F F Remarks on application: For evaporation temperatures higher than 32 °F do not run
compressor at condensing temperatures higher 122 °F in steady state operation.
Motor
Motor type CSIR/RSIR/RSCR LRA (rated after 4 sec. UL984), HST | LST A 21.4 17.3 Cut in Current, HST | LST A 21.4 24.9 Resistance, main | start winding (77°F) 2.8 6.4
Design
Displacement cu.in 0.29 Oil quantity (type) .oz. 7.8 (polyolester) Maximum refrigerant charge oz. 5.3 Free gas volume in compressor .oz. 49.5 Weight without electrical equipment lbs. 18.0
Dimensions
Height inch A 6.90
Suction connector location, I.D. in. | angle C 0.320-0.327 | 18°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 60°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 25°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
B 6.64 B1 – B2
Application
DLE4.8CN
SUCTION
Red stripe
Approvals
Barcode on white background Green background Country of origin or manufacturer
S = Static cooling normally sufcient
O = Oil cooling
= Fan cooling 1.5 m/s
F
1
(compressor compartment temperature equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area
R290
serial number
Made by Secop
102H
3582
DEHC.ED.100.D1.22
© Danfoss | DCS (CC) | 2015.10 | 1
ASHRAE LBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in BTU/h 544 741 898 971 1239 1553 1694 1921 2349 2443 2846 2900 3123 Power cons. in W 150 172 188 194 215 234 242 252 268 270 280 281 285 Current cons. in A 2.42 2.52 2.60 2.63 2.75 2.88 2.93 3.00 3.13 3.15 3.25 3.26 3.30 EER in BTU/Wh 3.62 4.30 4.79 5.00 5.77 6.63 7.00 7.62 8.78 9.04 10.20 10.30 11.00
ASHRAE MBP/HBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in BTU/h 486 663 803 867 1106 1386 1511 1713 2092 2175 2531 2579 2775 Power cons. in W 149 171 186 192 213 232 239 249 264 267 277 278 282 Current cons. in A 2.42 2.52 2.60 2.63 2.75 2.88 2.93 3.00 3.13 3.15 3.25 3.26 3.30 EER in BTU/Wh 3.26 3.88 4.32 4.51 5.20 5.98 6.32 6.87 7.91 8.14 9.15 9.28 9.85
EN 12900 LBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 175 224 265 284 359 448 488 554 678 706 823 839 904 Power cons. in W 157 172 183 188 204 220 226 235 249 252 262 263 268 Current cons. in A 2.37 2.47 2.53 2.56 2.65 2.73 2.76 2.80 2.85 2.86 2.89 2.89 2.90 COP in W/W 1.12 1.30 1.45 1.52 1.76 2.04 2.16 2.36 2.72 2.80 3.14 3.19 3.38
EN 12900 MBP 115V, 60Hz, fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 161 208 248 266 336 420 457 518 634 659 768 782 842 Power cons. in W 159 177 189 195 212 230 236 246 261 264 274 275 279 Current cons. in A 2.39 2.48 2.55 2.58 2.67 2.77 2.80 2.85 2.93 2.94 2.99 3.00 3.02 COP in W/W 1.01 1.18 1.31 1.37 1.58 1.83 1.93 2.11 2.43 2.50 2.81 2.85 3.02
Accessories for DLE4.8CN Figure Code number Test conditions
ePTC starting device 1/4 in. spade connectors a1 103N0058 *
)
Condensing temperature 104°F 113°F Starting relay 1/4 in. spade connectors a2 117U7011 Ambient temperature 90°F 90°F Start. capacitor 240 µF 1/4 in. spade connectors c 117U5023 Suction gas temperature 68°F 68°F Cover b 103N0492 Liquid temperature no subcooling
EN 12900
LBP MBP
ASHRAE
LBP MBP
130°F 130°F
90°F 90°F 90°F 95°F 90°F 115°F
Cord relief d 103N1010
)
Remarks: RSIR and RSCR option available in 4th quarter 2015 Mounting accessories Code number
*
Bolt joint for one comp. Ø: 3/4 in. 118-1949
Bolt joint for one comp. Ø: 5/8 in. 118-1946
Snap-on for one comp. Ø: 5/8 in. 118-1947
2 | © Danfoss | DCS (CC) | 2015.10
DEHC.ED.100.D1.22
ASHRAE LBP 115V, 60Hz, RC 15 µF, ePTC consumption incl., fan cooling F
Danf already on order pro All trademarks in this material are property of the respec
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in BTU/h 555 756 916 990 1264 1585 1728 1959 2396 2492 2903 2958 3185 Power cons. in W 145 165 180 186 205 223 230 240 254 257 266 267 271 Current cons. in A 1.61 1.75 1.84 1.89 2.03 2.17 2.23 2.31 2.44 2.47 2.56 2.57 2.62 EER in BTU/Wh 3.83 4.57 5.10 5.34 6.17 7.10 7.51 8.18 9.43 9.71 10.9 11.10 11.80
ASHRAE MBP/HBP 115V, 60Hz, RC 15 µF, ePTC consumption incl., fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in BTU/h 496 676 819 885 1129 1414 1541 1747 2134 2219 2582 2630 2831 Power cons. in W 143 164 178 184 203 221 228 237 251 254 263 264 267 Current cons. in A 1.61 1.75 1.84 1.89 2.03 2.17 2.23 2.31 2.44 2.47 2.56 2.57 2.62 EER in BTU/Wh 3.46 4.13 4.60 4.82 5.56 6.40 6.77 7.37 8.50 8.75 9.83 9.98 10.60
EN 12900 LBP 115V, 60Hz, RC 15 µF, ePTC consumption incl., fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 179 228 270 290 366 457 498 565 692 720 840 856 922 Power cons. in W 151 165 175 180 195 210 215 224 237 240 249 250 255 Current cons. in A 1.57 1.68 1.76 1.79 1.90 1.99 2.03 2.08 2.16 2.17 2.22 2.22 2.24 COP in W/W 1.18 1.38 1.54 1.61 1.88 2.18 2.31 2.52 2.92 3.00 3.37 3.42 3.62
EN 12900 MBP 115V, 60Hz, RC 15 µF, ePTC consumption incl., fan cooling F
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
2
Capacity in W 164 213 253 272 343 428 466 529 646 672 783 798 859 Power cons. in W 153 170 181 186 203 219 225 234 248 251 260 261 265 Current cons. in A 1.59 1.71 1.79 1.82 1.94 2.05 2.09 2.15 2.24 2.26 2.32 2.33 2.35 COP in W/W 1.07 1.25 1.39 1.46 1.69 1.95 2.07 2.26 2.61 2.68 3.01 3.06 3.24
Accessories for DLE4.8CN Figure Code number Test conditions
ePTC starting device 1/4 in. spade connectors a1 103N0058 * Run capacitor 15 µF 1/4 in. spade connectors (optional) Suction gas temperature 68°F 68°F Cover b 103N0492 Liquid temperature no subcooling Cord relief d 103N1010
)
Remarks: RSIR and RSCR option available in 4th quarter 2015 Mounting accessories Code number
*
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
3 | © Danfoss | DCS (CC) | 2015.10
)
Condensing temperature 104°F 113°F
Ambient temperature 90°F 90°F
e 117-7118 *
)
Bolt joint for one comp. Ø: 3/4 in. 118-1949
Bolt joint for one comp. Ø: 5/8 in. 118-1946
Snap-on for one comp. Ø: 5/8 in. 118-1947
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
EN 12900
LBP MBP
ASHRAE
LBP MBP
130°F 130°F
90°F 90°F 90°F 95°F 90°F 115°F
DEHC.ED.100.D1.22