Danfoss DCB20-HV Technical Information

Counterbalance Valves Technical Information
Dual Counterbalance - Hydraulic Vent DCB20-HV
OPERATION
DCB20-HV: Dual counterbalance HIC, 20-size, hydraulic vent. This HIC is low leakage and internally piloted. The DCB20-HV uses 2 CB20-HV 20-size cartridges and allows free ow from the V port to the C ports and blocks ow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port.
APPLICATIONS
Use dual counterbalance HIC’s for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator.
SPECIFICATIONS SCHEMATIC
Rated pressure 350 bar [5075psi]*
Rated ow at
22 bar (319 psi )
Leakage 10 drops/min @ at 70% of
Weight Aluminum 5.59 kg [12.59 lb]
Pilot ratio 3.0:1, 4.5:1, 10.0:1
Cavity CIB
* 350 bar with steel housing
210 bar with aluminum housing
266 l/min [70 US gal/min]
crack pressure
Ductile 10.68 kg [23.55 lb]
PERFORMANCE
BC332375678109en-000101 • February 2020
CB - 33
DIMENSIONS
mm [in]
EXAMPLE CIRCUITS
Counterbalance Valves Technical Information
Dual Counterbalance - Hydraulic Vent
DCB20-HV
turn ccw to increase presure setting
turn cw to decrease pressure setting
Bi-directional Counterbalance
ORDERING INFORMATION
Counterbalance with Pressure Limiting
DCB20-HVDCB20-HV
BC332375678109en-000101 • February 2020
CB - 34