Danfoss DCB20-HV Technical Information

Counterbalance Valves Technical Information

Dual Counterbalance - Hydraulic Vent

DCB20-HV

OPERATION

DCB20-HV: Dual counterbalance HIC, 20-size, hydraulic vent. This HIC is low leakage and internally piloted. The DCB20-HV uses 2 CB20-HV 20-size cartridges and allows free flow from the V port to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port.

APPLICATIONS

Use dual counterbalance HIC’s for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator.

SPECIFICATIONS

SCHEMATIC

Rated pressure

350 bar [5075psi]*

Rated flow at

266 l/min [70 US gal/min]

22 bar (319 psi )

 

 

Leakage

10 drops/min @ at 70% of

 

crack pressure

Weight

Aluminum 5.59 kg [12.59 lb]

 

Ductile

10.68 kg [23.55 lb]

Pilot ratio

3.0:1, 4.5:1, 10.0:1

Cavity

CIB

 

*350 bar with steel housing

210 bar with aluminum housing

PERFORMANCE

BC332375678109en-000101 • February 2020

CB - 33

Danfoss DCB20-HV Technical Information

Counterbalance Valves Technical Information

Dual Counterbalance - Hydraulic Vent

DCB20-HV

DIMENSIONS mm [in]

turn ccw to increase presure setting

turn cw to decrease pressure setting

EXAMPLE CIRCUITS

Bi-directional

Counterbalance DCB20-HV

Counterbalance

with Pressure DCB20-HV

Limiting

ORDERING INFORMATION

BC332375678109en-000101 • February 2020

CB - 34