Danfoss DCB10-HV Technical Information

Counterbalance Valves Technical Information
100
15
US gal/min
psi
12
963
Dual Counterbalance - Hydraulic Vent DCB10-HV
OPERATION
APPLICATIONS
Dual counterbalance HIC’s are used for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator.
SPECIFICATIONS SCHEMATIC
Rated pressure 350 bar [5075 psi]*
Rated ow at
22 bar (319 psi )
Leakage 10 drops/min @ at 70% of
Weight 0.90 kg [1.98 lb]
Pilot ratio 3.0:1, 4.5:1, 10.0:1
Cavity CIB
* 350 bar with steel housing
210 bar with aluminum housing
60 l/min [16 US gal/min]
crack pressure
EXAMPLE CIRCUIT
Bi-directional
PERFORMANCE
Motor Control
bar
26 cSt [121 SUS] hyd.oil at 50°C [122°F]
25
300
200
20
15
10
Pilot open
Free flow
DCB10-HV
5
0
10 20 30 40 50 60
BC332375678109en-000101 • February 2020
l/min
CB - 27
DIMENSIONS
Counterbalance Valves Technical Information
Dual Counterbalance - Hydraulic Vent DCB10-HV
mm [in]
35.00 [1 .38]
BSP Port
38 [1 .50]
17.5 [0.69]
ORDERING INFORMATION
BSP Ported - (Body Only)
DIAM
6.
5 [0.26]
35.00 [1 .38]
BSP Port
33 [1 .30]
70.00 [2.76]
38 [1 .50]
20 [0 .79]
15 [0 .59]
70 [2 .76]
100.00 [3.94]
15 [0 .59]
17.5 [0.69] BSP
Port
67 [2 .64 ]
Bottom View
BSP Port
BC332375678109en-000101 • February 2020
CB - 28
Loading...