3. UL Coil ................................................................................................................................................................................4
4. BE Coil ................................................................................................................................................................................5
5. BO Coil ...............................................................................................................................................................................7
The coils for the Danfoss High-Pressure Pumps
valves are high-performance and reliable coils
based on more than 50 years manufacturing of
solenoid valves.
The coils are designed for the VDH and VDHT
High-Pressure solenoid valve program and are
available with many dierent options.
For information about other coil types not listed
in this data sheet, please contact the Danfoss
High-Pressure Systems sales department.
The Clip-on fastening system ensures a faultless
installation. A Danfoss Clip-on coil can be
mounted without the use any tools, and it is
simple to dismount the coil by means of a
screwdriver.
Power consumption, holdingAC: 19 VA, 11 W / DC: 16 W
Insulation of coil windingsClass H according to IEC 85
ConnectionSpade connector in accordance with DIN 43650 form A
Enclosure, IEC 529IP00 with spade connec., IP20 with protective cap, IP65 with cable plug
Ambient temperatureMax. +50 °C /+80 °C - see table below for details
Duty ratingContinuous
• IP00 version with spade connector in
accordance with DIN 43650, form A.
• IP20 version with protective cap
• IP65 version with mounted cable plug
• Standard coils available with 3 core cable,
for DIN plugs
• Coils can be tted without the use of tools
• Coils can only be removed with the use of
tools
220/380V AC coils: +15%, -15%. 230/400V AC coils: +6%, -10%.
Other AC coils with NC valve: +10%, -15%
Other AC coils with NO valve and all DC coils: ± 10%
2.3 Code numbers
Power
consumption
holding
11 W AC
16 W DCBB024DSmax. +50 °C24 V DC018F7928
Contact Danfoss for delivery of coils for other voltages
1)
Code nos. to be ordered in Danfoss Sensing Solutions (PL04)
Power consumption, holdingAC: 21 VA, 10 W / DC: 16 W
Insulation of coil windingsClass H according to IEC 85
ConnectionTerminal box; PG 13.5 - on 3-core ying lead
Enclosure, IEC 529IP67
Ambient temperatureMax. +50 °C / +80 °C - see table below for details
Duty ratingContinuous
• All usual AC and DC voltages
• IP67 version with terminal box
• IP67 version with 3-core ying lead
• Coils can be tted without the use of tools
• Coils can only be removed with the use of tools
220/380V AC coils: +10%, -15%. 230/400V AC coils: +6%, -10%.
Other AC coils with NC valve: +10%, -15%
Other AC coils with NO valve and all DC coils: ± 10%
4.3 Code numbers
Power
consumption
holding
12 W ACBE024ASmax. +80 °C24 V, 50 Hz018F7920
10 W ACBE042ASmax. +80 °C42 V, 50 Hz018F7927
10 W ACBE048ASmax. +80 °C48 V, 50 Hz
12 W ACBE230ASmax. +80 °C220–230 V, 50 Hz018F7921
11 W ACBE240ASmax. +80 °C240 V, 50 Hz018F7924
14 W ACBE024BSmax. +80 °C24 V, 60 Hz018F7922
13 W ACBE220BSmax. +80 °C220 V, 60 Hz018F7925
11/15 W ACBE240BSmax. +80 °C 200-240 V, 50/60 Hz018F7926
15/13 W ACBE110CSmax. +50 °C110 V, 50/60 Hz018F7923
10 W ACBE200CSmax. +50 °C200 V, 50/60 Hz018F7929018F7918
17/14 ACBE230CSmax. +50 °C 220–230 V, 50/60 Hz018F7919
15 W DCBE012DSmax. +50 °C12 V018F7913
16 W DCBE024DSmax. +50 °C24 V018F7914018F7912
Contact Danfoss for delivery of coils for other voltages
Terminal box with LED indication48–220 V DC 24–250 V AC, 50/60 Hz018Z0089
Terminal box100 pcs package018Z0279
1)
Code nos. to be ordered in Danfoss Sensing Solutions (PL04)