Danfoss Coils Data sheet

Data Sheet
Data sheet
Coils for VDH and VDHT valves
Coils
for VDH and VDHT valves
hpp.danfoss.com.
www.danfoss.com
Data sheet | Coils for VDH and VDHT valves
Table of Contents
1. Introduction .....................................................................................................................................................................2
2. BB Coil ................................................................................................................................................................................3
3. UL Coil ................................................................................................................................................................................4
4. BE Coil ................................................................................................................................................................................5
5. BO Coil ...............................................................................................................................................................................7
6. Permanent magnet .......................................................................................................................................................8
1. Introduction
The coils for the Danfoss High-Pressure Pumps valves are high-performance and reliable coils based on more than 50 years manufacturing of solenoid valves.
The coils are designed for the VDH and VDHT High-Pressure solenoid valve program and are available with many dierent options.
For information about other coil types not listed in this data sheet, please contact the Danfoss High-Pressure Systems sales department.
The Clip-on fastening system ensures a faultless installation. A Danfoss Clip-on coil can be mounted without the use any tools, and it is simple to dismount the coil by means of a screwdriver.
AI319039085280en-000501 | 521B0980
Data sheet | Coils for VDH and VDHT valves
2. BB Coil 2.1 Features
11 W AC
16 W DC
Clip-on version
Windings of class H insulated wire moulded
in the coil body
Ambient temperature: Up to +80 °C
All usual AC and DC voltages
2.2 Technical data
Design In accordance with VDE 0580
Voltage tolerance
Power consumption, cut-in AC: 44 VA
Power consumption, holding AC: 19 VA, 11 W / DC: 16 W
Insulation of coil windings Class H according to IEC 85
Connection Spade connector in accordance with DIN 43650 form A
Enclosure, IEC 529 IP00 with spade connec., IP20 with protective cap, IP65 with cable plug
Ambient temperature Max. +50 °C /+80 °C - see table below for details
Duty rating Continuous
IP00 version with spade connector in accordance with DIN 43650, form A.
IP20 version with protective cap
IP65 version with mounted cable plug
Standard coils available with 3 core cable,
for DIN plugs
Coils can be tted without the use of tools
Coils can only be removed with the use of
tools
220/380V AC coils: +15%, -15%. 230/400V AC coils: +6%, -10%. Other AC coils with NC valve: +10%, -15% Other AC coils with NO valve and all DC coils: ± 10%
2.3 Code numbers
Power consumption holding
11 W AC
16 W DC BB024DS max. +50 °C 24 V DC 018F7928
Contact Danfoss for delivery of coils for other voltages
1)
Code nos. to be ordered in Danfoss Sensing Solutions (PL04)
Coil type Ambient temperature Supply voltage Code no.
BB024AS max. +80 °C 24 V, 50 Hz 018F7905
BB240AS max. +80 °C 240 V, 50 Hz 018F7906
Description Enclosure Code no.
Cable plug according to EN175301-803A, PG 9
Cable plug according to EN175301-803A, PG 8
IP67 042N12 56
IP65 0 42N1278
2.4 Dimensions and weight
Without cable plug 62 mm
With protective cap 77 mm
With cable plug 85 mm
1)
1)
L
© Danfoss | DCS (im) | 2021.05
Weight: 0.24 kg