Service Handbook
Danfoss Burner
Components
Up to
10%
Energy savings
from a year ly
oil burner service
installer.danfoss.co.uk
Good service is to fix customers’ problems.
Excellent service is to prevent those problems
from occurring.
Dear Danfoss partner,
Your oil burner needs the same attention as your car in order to perform
at its best. Regular inspection and servicing are essential to ensure that it is
running reliably and at optimum efficiency. By servicing your oil burner on a
yearly basis incl. replacement of components like nozzles, filters and coils the
burner can reduce oil consumption by as much as 10%. Keeping it free from
soot can achieve even greater savings.
Danfoss offers a complete range of components for most oil burners on
the market. The service manual is intended to make it easy for you to find
the most suitable components from the comprehensive Danfoss range and
service tip videos via the QR codes.
Happy service!
Your Danfoss Team
Contents
Links to Burner Components instruction videos ..................................... Page 3
1. Oil pumps
Contents Oil pumps ................................................................Page 9
Conversion......................................................................... Page 10
Spare parts and accessories......................................................... Page 54
Dimensions ........................................................................ Page 57
Connections ....................................................................... Page 63
2. Oil nozzles
Contents Oil nozzles ...............................................................Page 68
Introduction ....................................................................... Page 69
Brass nozzles EH/ES, OD and LE ..................................................... Page 70
Steel nozzles HFD/HD and SFD/SD .................................................Page 81
Conversion ........................................................................ Page 82
Dimensions ........................................................................ Page 83
Marking............................................................................ Page 85
1
3. Oil burner controls
Contents Oil burner controls .......................................................Page 86
Introduction ....................................................................... Page 87
Conversion......................................................................... Page 89
Dimensions ........................................................................ Page 95
Flame sensors...................................................................... Page 96
Service............................................................................. Page 98
Accessories ........................................................................Page 99
Flash codes ........................................................................Page 100
4. Ignition units
Contents Ignition units .............................................................Page 101
Introduction ....................................................................... Page 102
Conversion......................................................................... Page 104
Dimensions ........................................................................ Page 111
Service............................................................................. Page 113
5. Oil preheaters
Contents Oil preheaters ............................................................Page 115
Conversion ........................................................................ Page 116
Dimensions ........................................................................ Page 117
2
Links to Burner Components instruction videos
Changing the oil nozzle
Instructions for a safe and optimal change of a
Danfoss oil nozzle on an oil burner.
Changing the oil pump (BFP)
Instructions for a safe and optimal changing of the
Danfoss oil pump (BFP).
Changing the cartridge lter in the oil pump
(BFP 20, 21, 41 and 52)
Instructions for a safe and optimal change of a
cartridge lter in a Danfoss oil pump (BFP 20, 21,
41 and 52).
Changing the ring lter in the oil pump
(BFP 10 and 11)
Instructions for a safe and optimal change of ring
lter in a Danfoss oil pump (BFP 10 and 11).
3
Changing the coil on the oil pump (BFP)
Instructions for a safe and optimal change of the
coil on a Danfoss oil pump (BFP).
Changing the solenoid valve (NC) on the oil
pump (BFP)
Instructions for a safe and optimal change of the
solenoid valve (NC valve) on a Danfoss oil pump
(BFP).
Converting the oil pump from a 1 to a 2 pipe
system (BFP 20, 21, 41, 52)
Instructions for a safe and optimal conversion
from a one pipe system to a two pipe system on a
Danfoss oil pump (BFP 20, 21, 41 and 52).
Converting the oil pump from a 1 to a 2 pipe
system (BFP 10 and 11)
Instructions for a safe and optimal conversion from
a 1 pipe to a 2 pipe system (BFP 10 and 11)
4
Bleeding the oil pump (BFP 20, 21, 41 and 52)
Instructions for a safe and optimal bleeding of a
Danfoss oil pump (BFP 20, 21, 41 and 52).
Bleeding the oil pump (BFP 10 and 11)
Instructions for a safe and optimal bleeding of the
oil pump (BFP 10 and 11)
Bleeding the oil pump (BFP with bleed plug)
Instructions for a safe and optimal bleeding of the
oil pump (BFP with bleed plug)
Changing the LE valve in the preheater
Instructions for a safe and optimal change of the LE
valve in the preheater
5
Changing the oil burner control (OBC with a UV
sensor)
Instructions for a safe and optimal change of the
oil burner control (OBC with a UV sensor)
Reading failure codes on the oil burner control
(OBC)
Instructions for reading failure codes on the oil
burner control (OBC)
Changing the oil burner control (OBC with a LD/
LDS sensor)
Instructions for a safe and optimal change of oil
burner control (OBC with a LD/LDS sensor)
Changing the ame sensor (UV sensor)
Instructions for a safe and optimal change of the
ame sensor (UV sensor)
6
Changing the ame sensor (LD/LDS sensor)
Instructions for a safe and optimal change of the
ame sensor (LD/LDS sensor)
Changing the ignition unit (EBI3 to an EBI4)
Instructions for a safe and optimal change of
ignition unit (EBI3 to an EBI4)
7
8
Oil pumps
Contents
Introduction ............................................................................ Page 10
Conversion ................. Danfoss RS -> RSA Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12
Conversion ................. RSA/RSH -> RSA Service ................................... Page 13
Conversion ................. Danfoss RSL -> BFP Service ................................ Page 15
Conversion ................. Danfoss MSL -> BFP Service ................................ Page 17
Conversion ................. Danfoss MS -> BFP Service ................................. Page 20
Conversion ................. Danfoss BFP -> BFP Service ................................ Page 22
Conversion ................. Suntec -> BFP Service ...................................... Page 37
Conversion ................. Eckerle -> BFP Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 42
Conversion ................. DELTA -> BFP Service ...................................... Page 49
Spare parts and accessories.. RSA/RSH .................................................. Page 54
Spare parts and accessories.. BFP ....................................................... Page 55
Accessories .................BFP ....................................................... Page 56
Dimensions ................. BFP ....................................................... Page 57
Changeover 1-2 pipe ........RSA/BFP................................................... Page 61
Connections ................ RSA ....................................................... Page 63
Connections ................ BFP ....................................................... Page 64
Oil pumps
9
Oil pumps
Oil pump conversion
The tables below give the following pump conversions:
• Danfoss RS pumps to RSA pumps
• Danfoss RSL/MSL/MS/BFP pumps to BFP
service pumps
• Suntec pumps to BFP service pumps
• Eckerle pumps to BFP service pumps
• Delta pumps to BFP service pumps
Using Danfoss service pumps BFP 21 L3 and BFP 21
R3 it is possible to maintain 90% of existing small
burners. In other cases it can be dicult to nd the
correct Danfoss service pump. The main purpose of
the conversion tables is to make the replacement
of such pumps easier.
The tables are compiled as follows:
• Column 1 always gives the pump type to
be replaced.
• Column 2 gives the code number of the pump
to be replaced.
Note: Where Eckerle UNI-pumps are concerned,
column 1 gives the old and column 2 the new
designation.
• Column 3 states whether the pump is for
1-pipe or 2-pipe operation.
Note: With the MS pump, the numbers „1 +2“
are added because this particular unit has
automatic changeover. Eckerle pumps have no
suxes.
• Column 5 gives the Danfoss pump type able to
replace the existing pump.
• Column 6 gives the corresponding Danfoss
code number.
• The last column, „Comments/accessories“,
refers to special characteristics and features.
Please note that in some cases accessories are
necessary.
10
Explanation – code number and comments:
When changing over from pumps with hydraulic
shut-o valve (RSL and MSLC) to BFP with electric
shut-o valve (BFP 11, 21 and 41) a cable must be
ordered for connection to the motor terminals in
the oil burner control.
Some pump types carry the comment „No repl.“.
There are several possible explanations, among
them:
• The BFP service pump cannot supply the
required nozzle capacity.
• The BFP service pump does not have the
required coil voltage. BFP coils are only available
for 220-240 V a.c., 110-120V a.c., 24V a.c./12 V d.c.
and 24 V d.c.
• The shaft of the BFP service pump is not of a
suitable diameter.
• With the BFP service pump it is possible that a
hydraulic cylinder might be connected to the
pressure gauge port on the front.
The position of connections and clockwise/counterclockwise indication are always given when
looking on the shaft end. See Changeover 1-2 pipe.
Before tting a service pump, a check must be
made of whether it is set for 1-pipe or 2-pipe
operation. If necessary, the pump must be reset to
suit the system in which it is being installed.
As per October 2017 all service pumps have been
upgraded to Diamond Series 2.0 with Danfoss DLC
inside™ and extra durable Diamond Coil. All service
pumps are released for B10 bio heating oil.
Conversion of industrial pumps:
Pump types RSB/RSBK, RSF/RSFH, KSM, KSN, KSB,
KSV, KSVB and pressure regulating valves: B-PP,
B-P, B-G, B-GH, B-GHG and former Safag products
please contact HP Pumps; www.hptechnik.com
Oil pumps
11
Oil pumps
Conversion Danfoss RS RSA Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
RS 28 070-5300 1
RS 28 070L5376 1
RS 28 070-5302 2
RS 28 070L5370 2
RS 28 070-5310 1
RS 28 070L5310 1
RS 28 070-5312 2
RS 28 070L5312 2
RS 28 070-5322 2
RS 28 070L5322 2
RS 40 070-3200 1
RS 40 070L3200 1
RS 40 070-3202 2
RS 40 070L3202 2
RS 40 070-3210 1
RS 40 070L3210 1
RS 40 070-3212 2
RS 40 070L3212 2
RS 40 070-3222 2
RS 40 070L3222 2
RS 60 070-3300 1
RS 60 070L3300 1
RS 60 070-3302 2
RS 60 070L3302 2
1-2
pipe
Type Code no. Comments/accessories
RSA 28 070-5376
➨
RSA 28 070L5370
➨
RSA 28 070-5376 + mount 2-pipe screw
➨
RSA 28 070L5370 + mount 2-pipe screw
➨
➨
➨
➨
➨
➨
➨
RSA 40 070-3230
➨
RSA 40 070L3230
➨
RSA 40 070-3230 + mount 2-pipe screw
➨
RSA 40 070L3230 + mount 2-pipe screw
➨
RSA 40 070-3240
➨
RSA 40 070L3244
➨
RSA 40 070-3240 + mount 2-pipe screw
➨
RSA 40 070L3244 + mount 2-pipe screw
➨
RSA 40 070-3249
➨
RSA 40 070L3249
➨
RSA 60 070-3354
➨
RSA 60 070L3350
➨
RSA 60 070-3354 + mount 2-pipe screw
➨
RSA 60 070L3350 + mount 2-pipe screw
➨
No repl.
No repl.
No repl.
No repl.
No repl.
No repl.
12
Conversion Danfoss RS ➨ RSA Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
RS 60 070-3310 1
RS 60 070L3310 1
RS 60 070-3312 2
RS 60 070L3312 2
1-2
pipe
Type Code no. Comments/accessories
RSA 60 070-3360
➨
RSA 60 070L3366
➨
RSA 60 070-3360 + mount 2-pipe screw
➨
RSA 60 070L3362
➨
Conversion Danfoss RSA/RSH ➨ RSA Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
RSA 40 070-3232 2
RSA 40 070-3242 2
RSA 60 070-3350 1
RSA 60 070-3352 2
RSA 60 070-3362 2
RSA 125 070-3402 2
RSA 125 070-3412 2
RSA 95 070-3472 2
RSA 95 070-3482 2
RSA 28 070-5332 2
RSA 28 070-5370 1
RSA 28 070-5372 2
RSA 28 070-5380 1
RSA 28 070-5382 2
RSA 40 070L3232 2
RSA 40 070L3240 1
1-2
pipe
Type Code no. Comments/accessories
RSA 40 070-3230
➨
RSA 40 070-3240
➨
RSA 60 070-3354
➨
RSA 60 070-3354
➨
RSA 60 070-3360
➨
RSA 125 070-3400
➨
RSA 125 070-3410
➨
RSA 95 070-3470
➨
RSA 95 070-3480
➨
➨
RSA 28 070-5376
➨
RSA 28 070-5376 + mount 2-pipe screw
➨
➨
➨
RSA 40 070L3230 + mount 2-pipe screw
➨
RSA 40 070L3244
➨
No repl.
No repl.
No repl.
+ mount 2-pipe screw
+ mount 2-pipe screw
Oil pumps
13
Oil pumps
Conversion Danfoss RSA/RSH ➨ RSA Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
RSA 40 070L3242 2
RSA 40 070L3247 1
RSA 60 070L3356 2
RSA 60 070L3360 1
RSA 125 070L3402 2
RSA 125 070L3403 2
RSA 125 070L3413 1
RSA 125 070L3422 2
RSA 95 070L3472 2
RSA 95 070L3474 1
RSA 28 070L5332 2
RSA 28 070L5372 2
RSA 28 070L5380 1
RSA 28 070L5382 2
RSH 63 070-6300 1
RSH 63 070-6310 1
RSH 125 070-6400 1
RSH 125 070-6410 1
RSH 95 070-6480 1
RSH 32 070-7300 1
RSH 32 070-7310 1
RSH 63 070L6300 1
RSH 63 070L6310 1
RSH 125 070L6400 1
RSH 125 070L6410 1
RSH 95 070L6480 1
RSH 32 070L7300 1
RSH 32 070L7310 1
1-2
pipe
Type Code no. Comments/accessories
RSA 40 070L3244 + mount 2-pipe screw
➨
RSA 40 070L3248
➨
RSA 60 070L3350 + mount 2-pipe screw
➨
RSA 60 070L3366
➨
RSA 125 070L3400 + mount 2-pipe screw
➨
➨
RSA 125 070L3410 +070-0211
➨
RSA 125 070L3410
➨
RSA 95 070L3470 + mount 2-pipe screw
➨
➨
➨
RSA 28 070L5370 + mount 2-pipe screw
➨
➨
➨
RSA 60 070-3354 use 15-30 bar spr ing 070-0031 + 070-0042
➨
RSA 60 070-3360 use 15-30 bar spr ing 070-0031 + 070-0042
➨
RSA 125 070-3400 use 15-30 bar spr ing 070-0031
➨
RSA 125 070-3410 use 15-30 bar spr ing 070-0031
➨
RSA 95 070-3480 use 15-30 bar spr ing 070-0031
➨
➨ RSA 40 070-3230 use 15-30 bar spr ing 070-0031
RSA 40
➨
➨ RSA 60 070L3350 use 15-30 bar spring 070-0031 + 070-0042
➨ RSA 60 070L3366 use 15-30 bar spring 070-0031 + 070-0042
RSA 125
➨
➨ RSA 125 070L3410 use 15-30 bar spring 070-0031
➨ RSA 95 070L3482 use 15-30 bar spring 070-0031
RSA 40
➨
RSA 40
➨
No repl.
No repl.
No repl.
No repl.
No repl.
070-3240 use 15-30 bar spring 070-0031
070L3400 use 15-30 bar spring 070-0031
070L3230 use 15-30 bar spring 070-0031
070L3244 use 15-30 bar spring 070-0031
use 15-30 bar spring 070-0031+ 070-0211
+ mount 2 -pipe screw
14
Conversion Danfoss RSL ➨ BFP Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
RSL 028 070-4330 1
RSL 028 070L4330 1
RSL 028 070-4332 2
RSL 028 070L4332 2
RSL 028 070-4340 1
RSL 028 070L4340 1
RSL 028 070-4342 2
RSL 028 070L4342 2
RSL 050 070-3130 1
RSL 050 070L3130 1
RSL 050 070-3132 2
RSL 050 070L3132 2
RSL 050 070-3140 1
RSL 050 070L3140 1
RSL 050 070-3142 2
RSL 050 070L3142 2
1) The solenoid coil must be connected in parallel with the burner motor.
1-2
pipe
Type Code no. Comments/accessories
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 R5 071N7173
➨
BFP 21 L5 071N7172
➨
BFP 21 R5 071N7173
➨
BFP 21 L5 071N7172
➨
BFP 21 R5 071N7173
➨
RFP 21 L5 071N71721)
➨
BFP 21 R5 071N7173
➨
BFP 21 L5 071N7172
➨
1)
1)
+ cable, L = 710 mm: 071G0204
1)
1)
1)
1)
+ cable, L = 710 mm: 071G0204
1)
+ bush ∅ 54: 071B0011
1)
1)
1)
+ cable, L = 710 mm: 071G0204
1)
1)
1)
+ cable, L = 710 mm: 071G0204
1)
+ bush ∅ 54: 071B0011
1)
Oil pumps
15
Oil pumps
Conversion Danfoss RSLB ➨ BFP Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
RSLB 028 070-4030 1 BFP 20 R3 071N7169
RSLB 028 070L4030 1 BFP 20 L3 071N7168
RSLB 028 070-4032 2 BFP 20 R3 071N7169
RSLB 028 070L4032 2 BFP 20 L3 071N7168
RSLB 028 070-4040 1 BFP 20 R3 071N7169
RSLB 028 070L4040 1 BFP 20 L3 071N7168
RSLB 028 070-4042 2 BFP 20 R3 071N7169
RSLB 028 070L4042 2 BFP 20 L3 071N7168
RSLB 050 070-4130 1 BFP 20 R5 071N7129
RSLB 050 070L4130 1 BFP 20 L5 071N7126
RSLB 050 070-4132 2 BFP 20 R5 071N7129
RSLB 050 070L4132 2 BFP 20 L5 071N7126
RSLB 050 070-4140 1 BFP 20 R5 071N7129
RSLB 050 070L4140 1 BFP 20 L5 071N7126
RSLB 050 070-4142 2 BFP 20 R5 071N7129
RSLB 050 070L4142 2 BFP 20 L5 071N7126
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
2)
2)
2)
2)
+ bush ∅ 54: 071B0011
+ bush ∅ 54: 071B0011
16
Conversion Danfoss MSLA ➨ BFP Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
MSLA 032 071B0101 1
MSLA 032 071B0102 2
MSLA 032 071B0103 1
MSLA 032 071B0104 2
MSLA 032 071B0105 1
MSLA 032 071B0108 2
MSLA 032 071B0112 2
MSLA 032 071B0113 1
MSLA 032 071B0132 2
MSLA 032 071B1101 1
MSLA 032 071B1102 2
MSLA 032 071B1103 1
MSLA 032 071B1104 2
MSLA 032 071B1105 1
MSLA 032 071B1111 1
MSLA 032 071B1112 2
MSLA 032 071B1114 2
MSLA 032 071B1118 2
MSLA 032 071B1120 2
MSLA 032 071B1126 2
MSLA 032 071B1128 2
MSLA 032 071B1132 2
MSLA 032 071B1134 2
MSLA 032 071B1136 2
MSLA 032 071B1138 2
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 21 R3 071N7157
➨
BFP 21 R3 071N7157
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
➨
No repl.
BFP 21 R3 071N7157 + coil 110-120 V a.c.: 071N0061
BFP 21 R3 071N7157
BFP 21 R3 071N7157
BFP 21 R3 071N71573)+ coil 24 V a.c.: 071N0062
BFP 21 L3 071N7156
BFP 21 L3 071N7156
BFP 21 L3 071N7156 + coil 110-120 V a.c.: 071N0061
BFP 21 L3 071N7156
BFP 21 L3 071N7156
BFP 21 L3 071N7156
BFP 21 L3 071N7156
BFP 21 L3 071N7156
BFP 21 L3 071N7156
BFP 21 L3 071N7156
BFP 21 L3 071N71563)+ coil 24 V a.c.: 071N0062
BFP 21 L3 071N7156
BFP 21 L3 071N7156
BFP 21 L3 071N7156
3)
No repl.
No repl. MSLA = 200 V a.c.
No repl.
No repl.
MSLA = 100 V a.c.
3)
3)
MSLA 100 V a.c.
3)
3)
3)
3)
3)
3)
3)
3)
3)
+ cable,
L = 710 mm:
071G0204
Oil pumps
17
Oil pumps
Conversion Danfoss MSLA/MSLB ➨ BFP Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
MSLA 050 071B0201 1
MSLA 050 071B0202 2
MSLA 050 071B0203 1
MSLA 050 071B0204 2
MSLA 050 071B0205 1
MSLA 050 071B0208 2
MSLA 050 071B1201 1
MSLA 050 071B1202 2
MSLA 050 071B1203 1
MSLA 050 071B1204 2
MSLB 032 071B2101 1
MSLB 032 071B3101 1
MSLB 032 071B2102 2
MSLB 032 071B2104 2
MSLB 032 071B3102 2
MSLB 050 071B2201 1
MSLB 050 071B3201 1
MSLB 050 071B2202 2
MSLB 050 071B2203 1
MSLB 050 071B3202 2
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 21 R5 071N71732)
➨
BFP 21 R5 071N7173
➨
BFP 21 R5 071N7173
➨
BFP 21 R5 071N7173
➨
BFP 21 R5 071N71732)
➨
BFP 21 R5 071N7173 MSLA = 200 V a.c.
➨
BFP 21 L5 071N7172
➨
BFP 21 L5 071N7172
➨
BFP 21 L5 071N7172
➨
BFP 21 L5 071N7172
➨
BFP 20 R3 071N7169
➨
BFP 20 L3 071N7168
➨
BFP 20 R3 071N7169
➨
BFP 20 R3 071N7169
➨
BFP 20 L3 071N7168
➨
BFP 20 R5 071N7129
➨
BFP 20 L5 071N7126
➨
BFP 20 R5 071N7129
➨
BFP 20 R5 071N7129
➨
BFP 20 L5 071N7126
➨
2)
2)
2)
2)
2)
2)
2)
2)
MSLA = 100 V a.c.
+ coil 110-120 V a.c.: 071N0061
MSLA = 100 V a.c.
+ coil 110-120 V a.c.: 071N0061
+ cable,
L = 710 mm,
071G0204
18
Conversion Danfoss MSLC/MSLD ➨ BFP Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
MSLC 032 071B4101 1
MSLC 032 071B5101 1
MSLC 032 071B4102 2
MSLC 032 071B5102 2
MSLC 032 071B4103 1
MSLC 032 071B4105 1
MSLC 050 071B4201 1
MSLC 050 071B5201 1
MSLC 050 071B4202 2
MSLC 050 071B5202 2
MSLD 032 071B6101 1
MSLD 032 071B6102 2
MSLD 032 071B7101 1
MSLD 032 071B7102 2
MSLD 032 071B6201 1
MSLD 050 071B6202 2
MSLD 050 071B7201 1
MSLD 050 071B7202 2
1) The solenoid coil must be connected in parallel with the burner motor.
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 R3 071N7157
➨
BFP 21 R5 071N7173
➨
BFP 21 L5 071N7172
➨
BFP 21 R5 071N7173
➨
BFP 21 L5 071N7172
➨
BFP 20 R3 071N7169
➨
BFP 20 R3 071N7169
➨
BFP 20 L3 071N7168
➨
BFP 20 L3 071N7168
➨
BFP 20 R5 071N7129
➨
BFP 20 R5 071N7129
➨
BFP 20 L5 071N7126
➨
BFP 20 L5 071N7126
➨
1)
1)
1) 3)
1) 3)
1)
+ cable, L = 710 mm: 071G0204
1)
1) 2)
1) 2)
1)
1)
2)
2)
2)
2)
Oil pumps
19
Oil pumps
Conversion Danfoss MS ➨ BFP Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
MS 10 L3 071G0125 1 + 2
MS 10 R3 071G0123 1 + 2
MS 10 L3 071G0153 1 + 2
MS 10 R3 071G0175 1 + 2
MS 10 R5 071G0176 1 + 2
MS 10 L5 071G0128 1 + 2
MS 10 R5 071G0124 1 + 2
MS 11 L3 071G0117 1 + 2
MS 11 R3 071G0118 1 + 2
MS 11 L3 071G0121 1 + 2
MS 11 L3 071G0134 1 + 2
MS 11 L3 071G0137 1 + 2
MS 11 L3 071G0139 1 + 2
MS 11 L3 071G0154 1 + 2
MS 11 L3 071G0156 1 + 2
MS 11 L3 071G0158 1 + 2
MS 11 R3 071G0160 1 + 2
MS 11 L3 071G0162 1 + 2
MS 11 L3 071G0163 1 + 2
MS 11 L3 071G0165 1
MS 11 R3 071G0173 1 + 2
MS 11 R5 071G0174 1 + 2
MS 11 R3 071G0177 1 + 2
MS 11 L3 071G0178 1 + 2
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
No repl.
2)
2)
2)
2)
2)
2)
3)
2)
BFP 20 L3 071N7168
➨
BFP 20 R3 071N7169
➨
➨
BFP 20 R3 071N7169
➨
BFP 20 R5 071N7129
➨
BFP 20 L5 071N7126
➨
BFP 20 R5 071N7129
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156 + coupling with single at in hole (D-shaped)
➨
BFP 21 L3 071N7156 + coil 24 V a.c.: 071N0062
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157 + coil 24 V a.c.: 071N0062
➨
BFP 11 L3 071N7141
➨
BFP 11 L3 071N71413)+ coil 24 V a.c.: 071N0062
➨
BFP 21 L3 071N7156 MS has manual conversion
➨
BFP 21 R3 071N7157
➨
BFP 21 R5 071N7173
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
20
Conversion Danfoss MS ➨ BFP Service
Danfoss oil pumps – older series Relevant Danfoss types
Type Code no.
MS 11 L3 071G0179 1 + 2
MS 11 L5 071G0127 1 + 2
MS 11 R5 071G0126 1 + 2
MS 12 L3 071G0115 1 + 2
MS 12 R3 071G0113 1 + 2
MS 12 L5 071G0116 1 + 2
MS 12 R5 071G0114 1 + 2
MS 12 L3 071G0161 1 + 2
MS 12E L3 071G0130 1 + 2
MS 12E R3 071G0129 1 + 2
MS 12E L5 071G0120 1 + 2
MS 12E R5 071G0119 1 + 2
MS 12E L3 071G0140 1 + 2
MS 12E L5 071G0181 1 + 2
MS 21 L3 071G0157 1 + 2
MS 21 R3 071G0167 1 + 2
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
Strang
Type Code no. Comments/accessories
Any hydraulic cylinder must be connected to the
No repl.)
No repl.
No repl.
No repl.
No repl.
3)
pressure gauge port on the front.
2)
2)
2)
2)
2)
2)
3)
3)
BFP 21 L3 071N7156
➨
BFP 21 L5 071N7172
➨
BFP 21 R5 071N7173
➨
➨
➨
➨
➨
➨
BFP 52E L3 071N3201
➨
BFP 52E R3 071N3203
➨
BFP 52E L5 071N3202
➨
BFP 52E R5 071N3204
➨
BFP 52E L3 071N32012)
➨
BFP 52E L5 071N32022)
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
Oil pumps
21
Oil pumps
Conversion Danfoss BFP ➨ BFP Service
BFP – standard pump Relevant Danfoss types
Type Code no.
BFP 11 L3 071N0101 2
BFP 21 L3 071N0102 2
BFP 11 L3 071N0103 2
BFP 21 L3 071N0104 2
BFP 11 L5 071N0105 2
BFP 21 L3 071N0107 2
BFP 20 L3 071N0108 1
BFP 21 R3 071N0109 2
BFP 21 L3 071N0111 2
BFP 21 R3 071N0112 2
BFP 21 L3 071N0113 2
BFP 11 L3 071N0114 2
BFP 31 L3 071N0115 2
BFP 21 L5 071N0116 2
BFP 21 L3 071N0117 2
BFP 20 R3 071N0118 1
BFP 21 L3 071N0119 2
BFP 21 R5 071N0120 1
BFP 21 L3 071N0122 1
BFP 21 L3 071N0123 2
BFP 21 L3 071N0124 2
BFP 20 L3 071N0125 2
BFP 20 L5 071N0126 2
BFP 20 L3 071N0127 1
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 11 L3 071N7141
➨
BFP 21 L3 071N7156
➨
BFP 11 L3 071N7141
➨
BFP 21 L3 071N7156
➨
BFP 21 L5 071N7172
➨
BFP 21 L3 071N7156
➨
BFP 20 L3 071N7168
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N71563)+ coupling with single at in hole (D-shaped)
➨
BFP 21 L3 071N7156
➨
BFP 21 L5 071N7172
➨
BFP 21 L3 071N71563)+ coupling with single at in hole (D-shaped)
➨
BFP 20 R3 071N7169
➨
BFP 21 L3 071N7156
➨
BFP 21 R5 071N7173
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N71563)+ coil 110 V: 071N0061
➨
BFP 21 L3 071N7156
➨
BFP 20 L3 071N7168
➨
BFP 20 L5 071N7126
➨
BFP 20 L3 071N7168
➨
3)
3)
3)
3)
3)
2)
3)
3)
3)
3)
3)
2)
3)
2)
3)
2)
Any hydraulic cylinder must be connected
to the pressure gauge port on the front.
Any hydraulic cylinder must be connected
to the pressure gauge port on the front.
22
Conversion Danfoss BFP ➨ BFP Service
BFP – standard pump Relevant Danfoss types
Type Code no.
BFP 20 R3 071N0128 1
BFP 20 R5 071N0129 2
BFP 21 L3 071N0130 2
BFP 21 L3 071N0132 1
BFP 31 L3 071N0133 2
BFP 41 L3 071N0135 2
BFP 21 R3 071N0136 1
BFP 41 R3 071N0137 2
BFP 21 L3 071N0138 2
BFP 20 R3 071N0140 2
BFP 11 L3 071N0141 1
BFP 11 L3 071N0142 1
BFP 11 R3 071N0143 1
BFP 11 L3 071N0144 2
BFP 11 R3 071N0145 2
BFP 11 L3 071N0146 2
BFP 21 L3 071N0147 2
BFP 21 L3 071N0148 2
BFP 31 L3 071N0149 2
BFP 21 L3 071N0150 2
BFP 21 L3 071N0151 2
BFP 11 L3 071N0152 2
BFP 11 L3 071N0153 2
BFP 21 R3 071N0154 1
BFP 11 R3 071N0155 1
BFP 21 L3 071N0156 1
BFP 21 R3 071N0157 1
BFP 21 L5 071N0158 1
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 20 R3 071N7169
➨
BFP 20 R5 071N7129
➨
BFP 21 L3 071N71563)
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N71563) + coupling with single at in hole (D-shaped)
➨
BFP 41 L3 071N8213
➨
BFP 21 R3 071N7157
➨
BFP 41 R3 071N7137
➨
BFP 21 L3 071N71563) Old ttings must be used
➨
BFP 20 R3 071N7169
➨
BFP 11 L3 071N7141
➨
BFP 11 L3 071N7141
➨
BFP 11 R3 071N7155
➨
BFP 11 L3 071N71413)
➨
BFP 11 R3 071N71553)
➨
BFP 11 L3 071N71413)Old coil might be usable
➨
BFP 21 L3 071N71563)
➨
BFP 21 L3 071N71563)
➨
BFP 21 L3 071N71563)
➨
BFP 21 L3 071N71563)
➨
BFP 21 L3 071N71563)
➨
BFP 11 L3 071N71413)
➨
BFP 11 L3 071N71413) + coil 24 V a.c.: 071N0062
➨
BFP 21 R3 071N7157
➨
BFP 11 R3 071N7155
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L5 071N7172
➨
2)
3)
2)
Oil pumps
23
Oil pumps
Conversion Danfoss BFP ➨ BFP Service
BFP – standard pump Relevant Danfoss types
Type Code no.
BFP 21 R5 071N0159 1
BFP 41 L3 071N0160 1
BFP 20 L3 071N0161 1
BFP 20 R3 071N0162 1
BFP 11 R5 071N0163 2
BFP 21 L3 071N0164 2
BFP 11 R5 071N0165 2
BFP 10 R5 071N0166 2
BFP 21 R3 071N0167 2
BFP 20 L3 071N0168 2
BFP 20 R3 071N0169 2
BFP 21 L3 071N0170 2
BFP 21 R3 071N0171 2
BFP 21 L5 071N0172 2
BFP 21 R5 071N0173 2
BFP 41 L3 071N0174 2
BFP 21 L3 071N0175 1
BFP 21 L3 071N0176 1
BFP 10 R3 071N0177 2
BFP 11 L5 071N0178 2
BFP 21 L3 071N0179 2
BFP 20 R5 071N0180 2
BFP 11 R3 071N0181 2
BFP 21 L3 071N0182 2
BFP 11 R3 071N0183 2
BFP 21 L3 071N0184 2
BFP 21 L3 071N0185 2
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 21 R5 071N7173
➨
BFP 41 L3 071N8213
➨
BFP 20 L3 071N7168
➨
BFP 20 R3 071N7169
➨
BFP 21 R5 071N7173
➨
BFP 21 L3 071N7156
➨
BFP 21 R5 071N7173
➨
BFP 20 R5 071N7129
➨
BFP 21 R3 071N7157
➨
BFP 20 L3 071N7168
➨
BFP 20 R3 071N7169
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L5 071N7172
➨
BFP 21 R5 071N7173
➨
BFP 41 L3 071N8213
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156 + coil: 071N0061
➨
BFP 10 R3 071N7253
➨
BFP 21 L5 071N7172
➨
BFP 21 L3 071N7156
➨
BFP 20 R5 071N7129
➨
BFP 11 R3 071N7155
➨
BFP 21 L3 071N7156
➨
BFP 11 R3 071N7155
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
2)
2)
2)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
24
Conversion Danfoss BFP ➨ BFP Service
BFP – standard pump Relevant Danfoss types
Type Code no.
BFP 41 L3 071N0188 2
BFP 21 L3 071N0189 2
BFP 31 L3 071N0190 2
BFP 31 R3 071N0191 2
BFP 31 L3 071N0192 1
BFP 21 L3 071N0193 1
BFP 21 L5 071N0194 1
BFP 21 R5 071N0195 1
BFP 41 R3 071N0196 1
BFP 21 L3 071N0197 2
BFP 21 R3 071N0198 1
BFP 20 R3 071N0200 2
BFP 21 L5 071N0202 2
BFP 21 L3 071N0203 2
BFP 21 L3 071N0204 2
BFP 21 R5 071N0207 2
BFP 21 R3 071N0208 2
BFP 21 L3 071N0209 2
BFP 11 L3 071N0210 1
BFP 21 L4 071N0211 2
BFP 20 L3 071N0212 2
BFP 11 L3 071N0213 1
BFP 21 R3 071N0214 1
BFP 21 R3 071N0215 2
BFP 21 R5 071N0216 2
BFP 21 L3 071N0217 2
BFP 20 L3 071N0218 2
BFP 21 L4 071N0219 2
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 41 L3 071N8213
➨
BFP 21 L3 071N71563)+ coil: 071N0062
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
BFP 21 L5 071N7172
➨
BFP 21 R5 071N7173
➨
BFP 41 R3 071N7137
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 20 R3 071N7169
➨
BFP 21 L5 071N7172
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
BFP 21 R5 071N7173
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 11 L3 071N7141
➨
BFP 21 L3 071N71563)+ coupling with single at in hole (D-shaped)
➨
BFP 20 L3 071N7168 + coupling with single at in hole (D-shaped)
➨
BFP 11 L3 071N7141
➨
BFP 21 R3 071N7157
➨
BFP 21 R3 071N71573)071N0215 has G 1/8 in S+R
➨
BFP 21 R5 071N7173
➨
BFP 21 L3 071N7156
➨
BFP 20 L3 071N7168
➨
BFP21 L3 071N71563)+ coupling with single at in hole (D-shaped)
➨
3)
3)
3)
2)
2)
2)
3)
3)
3)
3)
3)
3)
Oil pumps
25
Oil pumps
Conversion Danfoss BFP ➨ BFP Service
BFP – standard pump Relevant Danfoss types
Type Code no.
BFP 21 L3 071N0221 1
BFP 41 L3 071N0224 1
BFP 41 L3 071N0225 2
BFP 21 L3 071N0226 2
BFP 21 L5 071N0227 2
BFP 21 L3 071N0228 2
BFP 20 R3 071N0229 2
BFP 21 R3 071N0230 2
BFP 21 R3 071N0231 1
BFP 21 L3 071N0232 1
BFP 21 L3 LE-S 071N0233 2
BFP 21 L5 LE-S 071N0234 2
BFP 41 R3 071N0235 2
BFP 21 L3 071N0236 2
BFPC-21 L5 071N0237 2
BFPC-21 L3 071N0238 2
BFP21 L3 LE-S 071N0239 2
BFPC-21 L3 071N0240 1
BFPC-21 L3 071N0241 1
BFPC-21 L3 071N0242 2
BFPC-21 L3 071N0243 2
BFPC-21 R3 071N0245 2
BFPC-21 R5 071N0248 2
BFP 21 L3 071N0250 2
BFP 21 L3 071N0251 2
BFP 21 L3 071N0252 1
BFP 10 R3 071N0253 1
BFP 21 R3 071N0254 2
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 21 L3 071N7156
➨
BFP 41 L3 071N8213
➨
BFP 41 L3 071N8213
➨
BFP 21 L3 071N7156
➨
BFP 21 L5 071N7172 + coupling with single at in hole (D-shaped)
➨
BFP 21 L3 071N7156
➨
BFP 20 R3 071N7169
➨
BFP 21 R3 071N7157
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 LE-S 071N3225 + coupling with single at in hole (D-shaped)
➨
BFP 21 L5 LE-S 071N3136 Use the coupling included
➨
BFP 41 R3 071N7137
➨
BFP 21 L3 071N71563)Old pump is with 1/8" RG in S+R
➨
BFP 21 L5 071N7172
➨
BFP 21 L3 071N7156
➨
BFP21 L3 LE-S 071N3225 Old pump is with 1/8" RG in S+R
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156 + 24 V a.c. coil 071N0062
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N71563)+ 24 V a.c. coil 071N0062
➨
BFP 21 R3 071N7157
➨
BFP 21 R5 071N7173
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
BFP 10 R3 071N7253
➨
BFP 21 R3 071N7157
➨
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
26
Conversion Danfoss BFP ➨ BFP Service
BFP – standard pump Relevant Danfoss types
Type Code no.
BFP 21 R3 071N0255 2
BFP 21 R3 071N0256 1
BFP 21 L5 071N0257 2
BFP 21 L5 071N0258 2
BFP 21 R5 071N0259 2
BFP 21 R5 071N0260 2
BFP 21 L4 071N0261 2
BFP 41 L3 LE-S 071N0262 2
BFP 20 L5 071N0263 2
BFP 21 L3 LE-S 071N0264 2
BFP 20 L3 071N0267 2
BFP 21 L5 071N0268 1
BFP 21 L5 071N0269 1
BFP 11 L6 071N0270 2
BFP 11 R6 071N0271 2
BFP 10 L6 071N0272 2
BFP 10 R6 071N0273 2
BFP 11 L6 071N0274 1
BFP 11 R6 071N0275 1
BFPC-21 R3 071N0279 1
BFPC-21 R3 071N0280 2
BFPC-21 R5 071N0281 2
BFPC-21 L3 071N0282 1
BFPC-21 R3 071N0283 1
BFPC-21 L3 071N0284 2
BFPC-21 R3 071N0285 2
BFPC-21 R3 071N0286 2
BFPC-21 R3 071N0287 2
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 21 R3 071N7157
➨
BFP 21 R3 071N7157
➨
BFP 21 L5 071N7172
➨
BFP 21 L5 071N7172
➨
BFP 21 R5 071N7173
➨
BFP 21 R5 071N7173
➨
BFP 21 L3 071N71563)+ coupling with single at in hole (D-shaped)
➨
BFP 41 L3 LE-S 071N3137
➨
BFP 20 L5 071N7126
➨
BFP 21 L3 LE-S 071N3225
➨
BFP 20 L3 071N7168
➨
BFP 21 L5 071N71722)100 V a.c.
➨
BFP 21 L5 071N71722)100 V a.c.
➨
BFP 21 L5 071N7172
➨
BFP 21 R5 071N7173
➨
BFP 20 L5 071N7126
➨
BFP 20 R5 071N7129
➨
BFP 21 L5 071N7172
➨
BFP 21 R5 071N7173
➨
BFP 21 R3 071N7157 + 24 V a.c. coil 071N0062
➨
BFP 21 R3 071N7157
➨
BFP 21 R5 071N7173
➨
BFP 21 L3 071N7156 Old coil might be usable
➨
BFP 21 R3 071N7157 Old coil might be usable
➨
BFP 21 L3 071N71563)Old coil might be usable
➨
BFP 21 R3 071N71573)+ 24 V a.c. coil 071N0062
➨
BFP 21 R3 071N71573)+ 24 V a.c. coil 071N0062
➨
BFP 21 R3 071N71573)+ 24 V a.c. coil 071N0062
➨
3)
2)
2)
3)
Oil pumps
Max. 40 l/h at 10 bar
27
Oil pumps
Conversion Danfoss BFP ➨ BFP Service
BFP – standard pump Relevant Danfoss types
Type Code no.
BFP 10 R3 071N0288 1
BFPC-21 L3 071N0289 1
BFP 21 L4 071N0291 2
BFP 21 L5 071N0292 2
BFP 21 L3 071N0295 2
BFP 20 R3 071N0298 1
BFP 21 L5 071N0299 2
BFP 21 L3 071N1107 2
BFP 11 R3 071N1108 2
BFP 21 R3 071N1109 2
BFP 21 R5 071N1173 2
BFP 21 L3 071N1175 2
BFP 41 L3 071N1196 2
BFP 21 L3 LE-S 071N1199 2
BFP 21 L3 071N1200 2
BFP 31 L3 071N1201 2
BFP 31 L3 071N1203 2
BFP 41 L3 071N1206 2
BFP 21 R5 071N1207 2
BFP 21 R3 071N1208 2
BFP 31 L3 071N1209 2
BFP 21 L3 LE-S 071N1211 2
BFP 41 L3 071N1213 1
BFP 21 L3 071N1214 1
BFP 21 R3 071N1215 1
BFP 21 L3 071N1216 2
BFP 21 L3 071N1217 2
BFP 21 L3 071N1219 2
BFP 20 L3 071N1220 2
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.
3) This pump is delivered for 1-pipe operation. A changeover to 2-pipe operation is possible, see Changeover 1 - 2 pipe.
1-2
pipe
Type Code no. Comments/accessories
BFP 10 R3 071N7253
➨
BFP 21 L3 071N7156 Old coil might be usable
➨
BFP 21 L3 071N71563)+ coupling with single at in hole (D-shaped)
➨
BFP 21 L5 071N7172 + coupling with single at in hole (D-shaped)
➨
BFP 21 L3 071N7156
➨
BFP 20 R3 071N7169
➨
BFP 21 L5 071N7172 200 V a.c.
➨
BFP 21 L3 071N7156
➨
BFP 11 R3 071N7155
➨
BFP 21 R3 071N7157
➨
BFP 21 R5 071N7173
➨
BFP 21 L3 071N7156
➨
BFP 41 L3 071N8213
➨
BFP 21 L3 LE-S 071N3225
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N7156
➨
BFP 41 L3 071N8213
➨
BFP 21 R5 071N7173
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 LE-S 071N3225 + coupling with single at in hole (D-shaped)
➨
BFP 41 L3 071N8213
➨
BFP 21 L3 071N7156
➨
BFP 21 R3 071N7157
➨
BFP 21 L3 071N7156
➨
BFP 21 L3 071N71563)+ coupling with single at in hole (D-shaped)
➨
BFP 21 L3 071N71563)+ coupling with single at in hole (D-shaped)
➨
BFP 20 L3 071N7168
➨
3)
2)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
28