Danfoss BD50F Data sheet

Danfoss BD50F Data sheet

BD50F

Direct Current Compressor

R134a, 12-24V DC &

100-240V AC 50/60Hz

General

Code number (without electronic units)

 

 

 

101Z0203

 

 

 

 

 

 

Electronic unit - standard

 

101N0210, 30 pcs: 101N0211

 

 

 

 

 

Electronic unit 12-24V DC - with metal shielding

 

101N0220, 30 pcs: 101N0221

Electronic unit 12-24V DC - high start performance

101N0230, 30 pcs: 101N0231

 

 

 

 

Electronic unit 12-24V DC - AEO & metal shielding

101N0320, 30 pcs: 101N0321

Electronic unit 12-24V DC & 100-240V AC 50/60Hz

101N0500, 36 pcs: 101N0501

 

 

Approved compressor - electronic unit combinations

refer to INSTRUCTIONS for 101N0xxx

Additional approvals

 

 

 

e4, C-Tick

 

 

 

 

 

 

 

Compressors on pallet

 

 

150

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

 

Application

 

 

LBP/MBP/HBP

 

 

 

 

 

 

 

 

Evaporating temperature

°F

 

 

-20 to 50

 

Voltage range (DC& AC)

 

12-24V DC & 100-240V AC 50/60Hz

 

 

 

 

 

 

Max. condensing temperature continuous (short)

°F

 

140 (158)

 

 

Max. winding temperature continuous (short)

°F

 

257 (275)

 

 

Cooling requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

Application

 

LBP

 

MBP

 

HBP

32°C

 

S

 

S

 

F1

38°C

 

S

 

S

 

F1

43°C

 

S

 

S

 

F1

Remarks on application: Fan cooling F1 depending on application and speed.

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

Variable speed

 

Resistance, all 3 windings (25°C)

Ω

 

1.8

 

 

 

 

 

 

 

 

 

Design

 

 

 

 

 

 

 

 

 

 

 

 

Displacement

cu.in.

 

0.15

 

 

Oil quantity (type)

fl .oz.

 

5.1 (polyolester)

 

 

 

 

 

 

 

Maximum refrigerant charge

oz.

 

10.5

 

 

Free gas volume in compressor

fl .oz.

 

29.6

 

 

 

 

 

 

 

 

Weight - Compressor/Electronic unit

lbs.

 

9.5/0.55

 

 

Standard battery protection settings (refer to 101N0xxx INSTRUCTIONS for optional settings)

Voltage

 

 

12V

 

24V

 

 

 

 

 

 

Cut out

VDC

 

10.4

 

22.8

Cut in

VDC

 

11.7

 

24.2

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

Height

inch

A

 

5.39

 

 

B

 

5.32

 

 

 

 

 

 

 

B1

 

5.04

 

 

B2

 

2.87

 

 

 

 

Suction connector

location/I.D. mm | angle

C

0.252-0259 | 41.5°

 

material | comment

 

Cu-plated steel | Al cap

 

 

 

 

Process connector

location/I.D. mm | angle

D

0.252-0259 | 45°

 

material | comment

 

Cu-plated steel | Al cap

Discharge connector

location/I.D. mm | angle

E

0.202-0.205 | 21°

 

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Remarks: inch connectors

 

 

 

 

 

 

 

 

 

 

 

S = Static cooling normally suffi cient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally suffi cent

= not applicable in this area

June 2011

DEHC.ED.100.M6.22 / 520N0953

1/2

Capacity (EN 12900 Household/CECOMAF)

 

12V DC, static cooling

watt

Operational errors shown by LED (optional)

 

rpm \ °F

-20

-13

-10

0

10

14

20

30

40

41

45

50

 

Error

 

 

 

 

 

 

Error type

 

 

 

 

 

 

2,000

95

126

142

201

273

308

359

458

571

583

632*

697*

 

code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,500

119

157

176

247

335

375

442

570

723*

740

809*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Thermal cut-out of electronic unit

 

 

 

3,000

142

189

211

297

402

450

529

682*

863*

 

 

 

 

 

(If the refrigeration system has been too heavily

 

3,500

167

220

245

343

464

518*

612*

790*

 

 

 

 

 

 

 

 

 

 

 

 

 

loaded, or if the ambient temperature is high, the

 

Capacity (ASHRAE LBP)

 

 

 

 

12V DC, static cooling

watt

 

electronic unit will run too hot).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rpm \ °F

-20

-13

-10

0

10

14

20

30

40

41

45

50

 

4

Minimum motor speed error

 

 

 

 

 

 

 

2,000

22.6

30.0

33.6

47.7

64.9

72.6

85.2

109

135

138*

150*

165*

 

 

(If

the

refrigeration

system is too heavily loaded,

 

2,500

28.2

37.3

41.7

58.5

79.3

88.9

105

135

171*

175*

191*

 

 

 

the

motor cannot

maintain

minimum

 

speed at

 

3,000

33.7

44.8

50.1

70.4

95.2

107

125

161*

204*

 

 

 

 

 

approximately 1,850 rpm).

 

 

 

 

 

 

 

3,500

39.8

52.2

58.2

81.3

110

123*

145*

187*

 

 

 

 

 

3

Motor start error

 

 

 

 

 

 

 

 

 

Power consumption

 

 

 

 

 

12V DC, static cooling

watt

 

(The rotor is blocked or the differential pres-sure in

 

rpm \ °F

-20

-13

-10

0

10

14

20

30

40

41

45

50

 

 

the refrigeration system is too high (>5 bar)).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,000

27.4

32.5

34.6

41.7

49.0

52.6

56.8

65.4

75.1

76.9*

80.4*

86.2*

 

2

Fan over-current cut-out

 

 

 

 

 

 

 

2,500

34.3

41.4

44.3

54.0

63.4

67.7

73.0

82.8

93.1*

94.9*

98.6*

 

 

 

(The fan

loads the

electronic

unit with

more than

 

3,000

41.4

50.1

53.7

65.2

76.2

81.3

87.4

98.9*

111*

 

 

 

 

 

1Apeak).

 

 

 

 

 

 

 

 

 

 

 

 

3,500

49.6

58.8

62.6

75.5

88.7

95.0*

103*

119*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Battery protection cut-out

 

 

 

 

 

 

 

Current consumption (for 24V applications the following must be halfed)

 

A

 

(The voltage is outside the cut-out setting).

 

rpm \ °F

-20

-13

-10

0

10

14

20

30

40

41

45

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,000

2.28

2.69

2.87

3.50

4.18

4.49

4.90

5.65

6.45

6.58*

6.87*

7.29*

 

Compressor speed

 

 

 

 

 

 

 

 

 

2,500

2.86

3.41

3.65

4.45

5.26

5.61

6.10

6.94

7.81*

7.94*

8.25*

 

 

Electronit unit

 

 

Resistor

 

Motor

 

 

 

Control

 

3,000

3.52

4.16

4.43

5.37

6.33

6.75

7.31

8.32

9.34*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(R1) [Ω]

 

speed

 

 

 

circuit

 

3,500

4.20

4.88

5.18

6.24

7.39

7.90*

8.61*

9.91*

 

 

 

 

 

Code number

 

 

 

 

 

 

 

 

 

 

 

 

 

calculated

 

 

 

 

 

 

current

 

COP (ASHRAE LBP)

 

 

 

 

 

12V DC, static cooling

W/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

values

 

[rpm]

 

 

 

 

[mA]

 

rpm \ °F

-20

-13

-10

0

10

14

20

30

40

41

45

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

101N0210

 

 

 

0

 

2,000

 

 

 

5

 

2,000

3.49

3.89

4.09

4.81

5.57

5.83

6.32

7.00

7.60

7.63*

7.86*

8.09*

 

 

 

 

 

 

 

 

 

 

 

 

 

277

 

2,500

 

 

 

4

 

2,500

3.47

3.81

3.97

4.58

5.28

5.52

6.05

6.89

7.76*

7.77*

8.21*

 

 

101N0220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

101N0230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3,000

3.43

3.77

3.93

4.55

5.27

5.52

6.05

6.89

7.76*

 

 

 

 

 

 

 

692

 

3,000

 

 

 

3

 

3,500

3.37

3.74

3.91

4.54

5.23

5.46*

5.94*

6.66*

 

 

 

 

 

101N0500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1523

 

3,500

 

 

 

2

 

COP (EN 12900 Household/CECOMAF)

 

 

12V DC, static cooling

W/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

AEO

 

 

 

6

 

rpm \ °F

-20

-13

-10

0

10

14

20

30

40

41

45

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

101N0320

 

 

 

173

 

2,000

 

 

 

5

 

2,000

0.82

0.92

0.96

1.13

1.31

1.38

1.48

1.64

1.78

1.79*

1.84*

1.90*

 

 

 

 

 

 

 

 

 

 

 

 

 

450

 

2,500

 

 

 

4

 

2,500

0.82

0.90

0.94

1.08

1.24

1.31

1.42

1.62

1.82

1.89*

1.93*

 

 

101N0400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3,000

0.81

0.89

0.93

1.07

1.24

1.31

1.42

1.62

1.82*

 

 

 

 

with AEO

 

 

 

865

 

3,000

 

 

 

3

 

3,500

0.80

0.88

0.92

1.07

1.23

1.30*

1.40*

1.56*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1696

 

3,500

 

 

 

2

 

power consumption is limited to 100W with 101N0500

* fan cooling of electronic unit compulsory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In AEO (Adaptive Energy Optimizing) speed mode the BD com-

 

Test conditions

 

 

EN 12900/CECOMAF

ASHRAE LBP

 

ressor will always adapt its speed to the actual cooling demand.

 

Condensing temperature

 

 

131°F

 

 

130°F

 

 

 

 

 

 

 

 

 

Wire Dimensions DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient temperature

 

 

 

90°F

 

 

90°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size

 

 

 

 

Max. length*

 

Max. length*

 

Suction gas temperature

 

 

90°F

 

 

90°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cross

AWG

 

12V operation

24V operation

 

Liquid temperature

 

 

 

no subcooling

 

90°F

 

 

 

 

 

 

 

 

 

 

section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[mm2]

[Gauge]

 

[m]

 

[ft.]

 

[m]

 

[ft.]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5

 

 

12

 

 

 

2.5

 

8

 

5

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

12

 

 

 

4

 

13

 

8

 

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

10

 

 

 

6

 

20

 

12

 

39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

8

 

 

 

10

 

33

 

20

 

66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Length between battery an electronic unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire Dimensions AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cross section min. 0.75 mm2 or AWG 18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories for BD50F

 

 

 

 

Code number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bolt joint for one comp.

 

Ø: 5/8 in.

 

118-1917

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bolt joint in quantities

 

Ø: 5/8 in.

 

118-1918

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Snap-on in quantities

 

Ø: 5/8 in.

 

118-1919

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote kit (without cable)

 

 

 

 

 

105N9210

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC line cord UL approved

 

 

 

 

 

105N9520

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC line cord VDE approved

 

 

 

 

 

105N9530

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Automoblie fuse

12V: 15A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC usage:

DIN 7258

 

24V: 7.5 A

 

 

 

Not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main switch

 

min. 20A

 

 

deliverable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC usage:

 

Fuse, 100-240V

min. 4A

 

 

from Secop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main switch

 

min. 6A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifi cations already agreed.