BD35F-HD
Heavy Duty
Direct Current Compressor
R134a, 12-24V DC
General
Code number (without electronic units) |
|
|
|
101Z0206 |
|
|
Electronic unit - Standard |
|
101N0210, 30 pcs: 101N0211 |
||||
Approval for compressor - electronic unit combination |
|
|
UL |
|
||
Additional approvals |
|
|
|
e4, C-Tick |
|
|
Compressors on pallet |
|
|
150 |
|
|
|
Application |
|
|
|
|
|
|
Application |
|
|
LBP/MBP/HBP |
|
||
Evaporating temperature |
°C |
|
-30 to 0 (10) |
|
||
Voltage range |
VDC |
9.6 - 17 / 21.3 - 31.5 |
||||
Max. condensing temperature continuous (short) |
°C |
|
60 (70) |
|
|
|
Max. winding temperature continuous (short) |
°C |
|
125 (135) |
|
|
|
Cooling requirements |
|
|
|
|
|
|
Application |
|
LBP |
|
MBP |
|
HBP |
32°C |
|
S |
|
S |
|
S |
38°C |
|
S |
|
S |
|
S |
43°C |
|
S |
|
S |
|
S |
Remarks on application: |
|
|
|
|
|
|
HD (Heavy Duty) version of the BD35F which can handle extreme vibrations. |
||||||
Fan cooling F1 depending on application and speed. |
|
|
|
|
|
|
For more info please contact: mobile@secop.com. |
|
|
|
|
|
|
Motor |
|
|
|
|
|
|
Motor type |
|
|
variable speed |
|
||
Resistance, all 3 windings (25°C) |
Ω |
|
2.2 |
|
|
|
Design |
|
|
|
|
|
|
Displacement |
cm3 |
|
2.00 |
|
|
|
Oil quantity (type) |
cm3 |
|
150 (polyolester) |
|
||
Maximum refrigerant charge |
g |
|
300 |
|
|
|
Free gas volume in compressor |
cm3 |
|
870 |
|
|
|
Weight - Compressor/Electronic unit |
kg |
|
4.3/0.27 |
|
|
Standard battery protection settings (refer to 101N0xxx Instructions for optional settings)
Voltage |
|
12V |
24V |
Cut out |
VDC |
10.4 |
22.8 |
Cut in |
VDC |
11.7 |
24.2 |
Dimensions
Height |
mm |
A |
137 |
|
|
B |
135 |
|
|
B1 |
128 |
|
|
B2 |
73 |
Suction connector |
location/I.D. mm | angle |
C |
6.2 | 40° |
|
material | comment |
|
Cu-plated steel | Al cap |
Process connector |
location/I.D. mm | angle |
D |
6.2 | 45° |
|
material | comment |
|
Cu-plated steel | Al cap |
Discharge connector |
location/I.D. mm | angle |
E |
5.0 | 21° |
|
material | comment |
|
Cu-plated steel | Al cap |
Connector tolerance |
I.D. mm |
|
±0.09, on 5.0 +0.12/+0.20 |
Remarks: |
|
|
|
S = Static cooling normally sufficient
O= Oil cooling
F1 |
= Fan cooling 1.5 m/s |
|
(compressor compartment temperature |
|
equal to ambient temperature) |
F2 |
= Fan cooling 3.0 m/s necessary |
SG |
= Suction gas cooling normally sufficent |
–= not applicable in this area
July 2013 |
Manufactured by Secop for Danfoss - DEHC.ED.100.F4.02 / 520N1476 |
1/2 |
Capacity (EN 12900 Household/CECOMAF) |
|
12V DC, static cooling |
watt |
Operational errors shown by LED (optional) |
|
|||||||||||||||
rpm \ °C |
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
-5 |
0 |
5 |
7.2 |
10 |
15 |
Error |
|
|
|
Error type |
|
|
|
2,000 |
15.8 |
23.9 |
26.9 |
33.1 |
43.8 |
56.6 |
71.7 |
89.9 |
111 |
122 |
136 |
|
code |
|
|
|
|
|
|
|
2,500 |
20.2 |
29.9 |
33.5 |
41.2 |
54.6 |
70.7 |
89.7 |
112 |
139 |
152 |
|
|
5 |
Thermal cut-out of electronic unit |
|
|||||
3,000 |
22.5 |
32.4 |
36.5 |
45.4 |
61.8 |
81.7 |
105 |
133 |
|
|
|
|
|
(If the refrigeration system has been too heavily |
||||||
3,500 |
26.2 |
35.9 |
40.4 |
50.5 |
69.8 |
93.6 |
122 |
|
|
|
|
|
|
loaded, or if the ambient temperature is high, the |
||||||
Capacity (ASHRAE LBP) |
|
|
|
|
12V DC, static cooling |
watt |
|
electronic unit will run too hot). |
|
|
|
|||||||||
|
|
|
|
4 |
Minimum motor speed error |
|
|
|
||||||||||||
rpm \ °C |
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
-5 |
0 |
5 |
7.2 |
10 |
15 |
|
|
|
|||||
|
(If the refrigeration |
system is |
too heavily |
loaded, |
||||||||||||||||
2,000 |
19.5 |
29.4 |
33.1 |
40.7 |
54.0 |
69.8 |
88.6 |
111 |
137 |
151 |
169 |
|
|
|||||||
|
|
the motor cannot maintain minimum speed at |
||||||||||||||||||
2,500 |
24.9 |
36.8 |
41.3 |
50.7 |
67.3 |
87.1 |
111 |
139 |
172 |
189 |
|
|
|
|||||||
|
|
|
approximately 1,850 rpm). |
|
|
|
||||||||||||||
3,000 |
27.7 |
39.9 |
44.9 |
55.9 |
76.1 |
101 |
130 |
164 |
|
|
|
|
3 |
Motor start error |
|
|
|
|
||
3,500 |
32.2 |
44.2 |
49.7 |
62.2 |
86.0 |
115 |
150 |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
(The rotor is blocked or the differential pres-sure in |
||||||||||||||
Power consumption |
|
|
|
|
|
12V DC, static cooling |
watt |
|
||||||||||||
|
|
|
|
|
|
the refrigeration system is too high (>5 bar)). |
|
|||||||||||||
rpm \ °C |
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
-5 |
0 |
5 |
7.2 |
10 |
15 |
2 |
Fan over-current cut-out |
|
|
|
|||
2,000 |
17.6 |
23.4 |
25.3 |
28.7 |
33.6 |
38.3 |
43.0 |
48.0 |
53.4 |
56.0 |
59.5 |
|
|
(The fan loads the electronic unit with more than |
||||||
2,500 |
23.3 |
30.9 |
33.3 |
37.8 |
44.1 |
50.2 |
56.2 |
62.3 |
68.7 |
71.7 |
|
|
|
1Apeak). |
|
|
|
|
|
|
3,000 |
29.9 |
36.0 |
38.3 |
43.0 |
50.7 |
58.7 |
66.8 |
74.8 |
|
|
|
|
1 |
Battery protection cut-out |
|
|
|
|||
3,500 |
36.0 |
42.8 |
45.4 |
50.8 |
59.5 |
68.9 |
78.5 |
|
|
|
|
|
|
(The voltage is outside the cut-out setting). |
|
|||||
Current consumption (for 24V applications the following must be halfed) |
|
A |
Compressor speed |
|
|
|
|
|||||||||||||
rpm \ °C |
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
-5 |
0 |
5 |
7.2 |
10 |
15 |
|
|
|
|
||||
2,000 |
1.5 |
2.0 |
2.1 |
2.4 |
2.8 |
3.2 |
3.6 |
4.0 |
4.5 |
4.67 |
5.0 |
|
Electronit unit |
|
Resistor |
Motor |
Control |
|||
2,500 |
1.9 |
2.6 |
2.8 |
3.2 |
3.7 |
4.2 |
4.7 |
5.2 |
5.8 |
5.98 |
|
|
Code number |
|
(R1) [Ω] |
speed |
circuit |
|||
3,000 |
2.5 |
3.0 |
3.2 |
3.6 |
4.2 |
4.9 |
5.6 |
6.2 |
|
|
|
|
calculated |
|
current |
|||||
3,500 |
3.0 |
3.6 |
3.8 |
4.3 |
5.0 |
5.7 |
6.5 |
|
|
|
|
|
|
|
|
values |
[rpm] |
[mA] |
||
COP (EN 12900 Household/CECOMAF) |
|
|
12V DC, static cooling |
W/W |
|
|
|
0 |
2,000 |
|
5 |
|||||||||
rpm \ °C |
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
-5 |
0 |
5 |
7.2 |
10 |
15 |
101N0210 |
|
277 |
2,500 |
|
4 |
||
2,000 |
0.90 |
1.02 |
1.06 |
1.15 |
1.31 |
1.48 |
1.67 |
1.87 |
2.08 |
2.17 |
2.29 |
|
|
692 |
3,000 |
|
3 |
|||
|
|
|
|
|
||||||||||||||||
2,500 |
0.87 |
0.97 |
1.01 |
1.09 |
1.24 |
1.41 |
1.60 |
1.80 |
2.02 |
2.12 |
|
|
|
|
|
1523 |
3,500 |
|
2 |
|
3,000 |
0.75 |
0.90 |
0.95 |
1.06 |
1.22 |
1.39 |
1.58 |
1.78 |
|
|
|
|
Wire Dimensions DC |
|
|
|
|
|||
3,500 |
0.73 |
0.84 |
0.89 |
1.00 |
1.17 |
1.36 |
1.55 |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
Size |
|
Max. length* |
|
Max. length* |
|||||||||||
COP (ASHRAE LBP) |
|
|
|
|
|
12V DC, static cooling |
W/W |
|
|
|||||||||||
-23.3 |
-20 |
-15 |
-10 |
-5 |
Cross |
AWG |
|
12V operation |
24V operation |
|||||||||||
rpm \ °C |
-30 |
-25 |
0 |
5 |
7.2 |
10 |
15 |
section |
|
|
|
|
|
|
|
|||||
2,000 |
1.10 |
1.25 |
1.31 |
1.42 |
1.61 |
1.82 |
2.06 |
2.31 |
2.57 |
2.70 |
2.84 |
|
|
|
|
|
|
|
|
|
|
[mm2] |
[Gauge] |
[m] |
[ft.] |
|
[m] |
[ft.] |
|||||||||||||
2,500 |
1.07 |
1.19 |
1.24 |
1.34 |
1.53 |
1.74 |
1.97 |
2.23 |
2.50 |
2.63 |
|
|
|
|||||||
|
|
2.5 |
12 |
|
2.5 |
8 |
|
5 |
16 |
|||||||||||
3,000 |
0.93 |
1.11 |
1.17 |
1.30 |
1.50 |
1.72 |
1.95 |
2.20 |
|
|
|
|
|
|
||||||
3,500 |
0.89 |
1.03 |
1.09 |
1.23 |
1.44 |
1.68 |
1.91 |
|
|
|
|
|
4 |
12 |
|
4 |
13 |
|
8 |
26 |
Test conditions |
|
|
EN 12900/CECOMAF |
|
ASHRAE LBP |
|
6 |
10 |
|
6 |
20 |
|
12 |
39 |
||||||
|
|
|
|
10 |
8 |
|
10 |
33 |
|
20 |
66 |
|||||||||
Condensing temperature |
|
|
55°C |
|
|
54.4°C |
|
|
|
|
*Length between battery and electronic unit |
|||||||||
Ambient temperature |
|
|
|
32°C |
|
|
32°C |
|
|
|
|
|
|
|
|
|
||||
Suction gas temperature |
|
|
32°C |
|
|
32°C |
|
Accessories for BD35F-HD |
|
Code number |
||||||||||
Liquid temperature |
|
|
|
no subcooling |
|
|
32°C |
|
|
|||||||||||
|
|
|
|
|
|
Bolt joint for one compressor Ø:16 mm |
118-1917 |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Bolt joint in quantities |
Ø:16 mm |
118-1918 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Snap-on in quantities |
Ø:16 mm |
118-1919 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote kit (without cable) |
|
|
105N9210 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard automoblie fuse |
12V: 30A |
Not |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
DIN 7258 |
|
|
|
24V: 15A |
deliverable |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
Main switch |
|
|
min. 30A |
from Secop |
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 |
Manufactured by Secop for Danfoss - DEHC.ED.100.F4.02 / 520N1476 |
July 2013 |