Danfoss BD35F-HD Data sheet

BD35F-HD Heavy Duty Direct Current Compressor R134a, 12-24V DC
General
Code number (without electronic units) 101Z0206
Electronic unit - Standard 101N0210, 30 pcs: 101N0211
Additional approvals e4, C-Tick
Compressors on pallet 150
Application
Application LBP/MBP/HBP
Evaporating temperature °C -30 to 0 (10)
Voltage range VDC 9.6 - 17 / 21.3 - 31.5
Max. condensing temperature continuous (short)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Application LBP MBP HBP
32°C S S S
38°C S S S
43°C S S S
Remarks on application:
HD (Heavy Duty) version of the BD35F which can handle extreme vibrations.
Fan cooling F
For more info please contact: mobile@secop.com.
Motor
Motor type variable speed
Resistance, all 3 windings (25°C) 2.2
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 300
Free gas volume in compressor cm
Weight - Compressor/Electronic unit kg 4.3/0.27
Standard battery protection settings
Voltage 12V 24V
Cut out VDC 10.4 22.8
Cut in VDC 11.7 24.2
Dimensions
Height mm A 137
Suction connector location/I.D. mm | angle C 6.2 | 40°
Process connector location/I.D. mm | angle D 6.2 | 45°
Discharge connector location/I.D. mm | angle E 5.0 | 21°
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
depending on application and speed.
1
(refer to 101N0xxx Instructions for optional settings)
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
°C 60 (70)
3
3
3
B 135
B1 128
B2 73
2.00
150 (polyolester)
870
S = Static cooling normally sufcient O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
July 2013 Manufactured by Secop for Danfoss - DEHC.ED.100.F4.02 / 520N1476 1/2
Capacity (EN 12900 Household/CECOMAF) 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 15.8 23.9 26.9 33.1 43.8 56.6 71.7 89.9 111 122 136 2,500 20.2 29.9 33.5 41.2 54.6 70.7 89.7 112 139 152 3,000 22.5 32.4 36.5 45.4 61.8 81.7 105 133 3,500 26.2 35.9 40.4 50.5 69.8 93.6 122
Capacity (ASHRAE LBP) 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 19.5 29.4 33.1 40.7 54.0 69.8 88.6 111 137 151 169 2,500 24.9 36.8 41.3 50.7 67.3 87.1 111 139 172 189 3,000 27.7 39.9 44.9 55.9 76.1 101 130 164 3,500 32.2 44.2 49.7 62.2 86.0 115 150
Power consumption 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 17.6 23.4 25.3 28.7 33.6 38.3 43.0 48.0 53.4 56.0 59.5 2,500 23.3 30.9 33.3 37.8 44.1 50.2 56.2 62.3 68.7 71.7 3,000 29.9 36.0 38.3 43.0 50.7 58.7 66.8 74.8 3,500 36.0 42.8 45.4 50.8 59.5 68.9 78.5
Current consumption
(for 24V applications the following must be halfed) A
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 1.5 2.0 2.1 2.4 2.8 3.2 3.6 4.0 4.5 4.67 5.0 2,500 1.9 2.6 2.8 3.2 3.7 4.2 4.7 5.2 5.8 5.98 3,000 2.5 3.0 3.2 3.6 4.2 4.9 5.6 6.2 3,500 3.0 3.6 3.8 4.3 5.0 5.7 6.5
COP (EN 12900 Household/CECOMAF) 12V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 0.90 1.02 1.06 1.15 1.31 1.48 1.67 1.87 2.08 2.17 2.29 2,500 0.87 0.97 1.01 1.09 1.24 1.41 1.60 1.80 2.02 2.12 3,000 0.75 0.90 0.95 1.06 1.22 1.39 1.58 1.78 3,500 0.73 0.84 0.89 1.00 1.17 1.36 1.55
COP (ASHRAE LBP) 12V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 1.10 1.25 1.31 1.42 1.61 1.82 2.06 2.31 2.57 2.70 2.84 2,500 1.07 1.19 1.24 1.34 1.53 1.74 1.97 2.23 2.50 2.63 3,000 0.93 1.11 1.17 1.30 1.50 1.72 1.95 2.20 3,500 0.89 1.03 1.09 1.23 1.44 1.68 1.91
Test conditions EN 12900/CECOMAF ASHRAE LBP
Condensing temperature 55°C 54.4°C Ambient temperature 32°C 32°C Suction gas temperature 32°C 32°C Liquid temperature no subcooling 32°C
Operational errors shown by LED (optional)
Error code
5
Thermal cut-out of electronic unit
(If the refrigeration system has been too hea vi ly loaded, or if the ambient tem pe ra ture is high, the electronic unit will run too hot).
4
Minimum motor speed error
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,850 rpm).
3
Motor start error
(The rotor is blocked or the differential pres-sure in the refrigeration system is too high (>5 bar)).
2
Fan over-current cut-out
(The fan loads the electronic unit with more than 1A
).
1
peak
Battery protection cut-out
(The voltage is outside the cut-out setting).
Error type
Compressor speed
Electronit unit Resistor
(R1) [Ω]
Code number
calculated
values [rpm]
Motor
speed
Control
circuit
current
[mA]
0 2,000 5
101N0210
277 2,500 4 692 3,000 3
1523 3,500 2
Wire Dimensions DC
Size Max. length* Max. length*
Cross AWG 12V operation 24V operation
section
2
] [Gauge] [m] [ft.] [m] [ft.]
[mm
2.5 12 2.5 8 5 16 4 12 4 13 8 26 6 10 6 20 12 39
10 8 10 33 20 66
*Length between battery and electronic unit
Accessories for BD35F-HD Code number
Bolt joint for one compressor Ø :16 mm 118-1917 Bolt joint in quantities Ø: 16 mm 118-1918 Snap-on in quantities Ø:16 m m 118-1919 Remote kit (without cable) 105N9210
Standard automoblie fuse 12V: 30A DIN 7258 Main switch
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
24V: 15A
min. 30A
Not
deliverable
from Secop
2/2 Manufactured by Secop for Danfoss - DEHC.ED.100.F4.02 / 520N1476 July 2013
Loading...