Danfoss BD35F-HD Data sheet

BD35F-HD

Heavy Duty

Direct Current Compressor

R134a, 12-24V DC

General

Code number (without electronic units)

 

 

 

101Z0206

 

Electronic unit - Standard

 

101N0210, 30 pcs: 101N0211

Approval for compressor - electronic unit combination

 

 

UL

 

Additional approvals

 

 

 

e4, C-Tick

 

Compressors on pallet

 

 

150

 

 

Application

 

 

 

 

 

 

Application

 

 

LBP/MBP/HBP

 

Evaporating temperature

°C

 

-30 to 0 (10)

 

Voltage range

VDC

9.6 - 17 / 21.3 - 31.5

Max. condensing temperature continuous (short)

°C

 

60 (70)

 

 

Max. winding temperature continuous (short)

°C

 

125 (135)

 

 

Cooling requirements

 

 

 

 

 

 

Application

 

LBP

 

MBP

 

HBP

32°C

 

S

 

S

 

S

38°C

 

S

 

S

 

S

43°C

 

S

 

S

 

S

Remarks on application:

 

 

 

 

 

 

HD (Heavy Duty) version of the BD35F which can handle extreme vibrations.

Fan cooling F1 depending on application and speed.

 

 

 

 

 

For more info please contact: mobile@secop.com.

 

 

 

 

 

Motor

 

 

 

 

 

 

Motor type

 

 

variable speed

 

Resistance, all 3 windings (25°C)

 

2.2

 

 

Design

 

 

 

 

 

 

Displacement

cm3

 

2.00

 

 

Oil quantity (type)

cm3

 

150 (polyolester)

 

Maximum refrigerant charge

g

 

300

 

 

Free gas volume in compressor

cm3

 

870

 

 

Weight - Compressor/Electronic unit

kg

 

4.3/0.27

 

 

Standard battery protection settings (refer to 101N0xxx Instructions for optional settings)

Voltage

 

12V

24V

Cut out

VDC

10.4

22.8

Cut in

VDC

11.7

24.2

Dimensions

Height

mm

A

137

 

 

B

135

 

 

B1

128

 

 

B2

73

Suction connector

location/I.D. mm | angle

C

6.2 | 40°

 

material | comment

 

Cu-plated steel | Al cap

Process connector

location/I.D. mm | angle

D

6.2 | 45°

 

material | comment

 

Cu-plated steel | Al cap

Discharge connector

location/I.D. mm | angle

E

5.0 | 21°

 

material | comment

 

Cu-plated steel | Al cap

Connector tolerance

I.D. mm

 

±0.09, on 5.0 +0.12/+0.20

Remarks:

 

 

 

S = Static cooling normally sufficient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

July 2013

Manufactured by Secop for Danfoss - DEHC.ED.100.F4.02 / 520N1476

1/2

Danfoss BD35F-HD Data sheet

Capacity (EN 12900 Household/CECOMAF)

 

12V DC, static cooling

watt

Operational errors shown by LED (optional)

 

rpm \ °C

-30

-25

-23.3

-20

-15

-10

-5

0

5

7.2

10

15

Error

 

 

 

Error type

 

 

2,000

15.8

23.9

26.9

33.1

43.8

56.6

71.7

89.9

111

122

136

 

code

 

 

 

 

 

 

 

2,500

20.2

29.9

33.5

41.2

54.6

70.7

89.7

112

139

152

 

 

5

Thermal cut-out of electronic unit

 

3,000

22.5

32.4

36.5

45.4

61.8

81.7

105

133

 

 

 

 

 

(If the refrigeration system has been too heavi­ly­

3,500

26.2

35.9

40.4

50.5

69.8

93.6

122

 

 

 

 

 

 

loaded, or if the ambient tem­pera­ture­ is high, the

Capacity (ASHRAE LBP)

 

 

 

 

12V DC, static cooling

watt

 

electronic unit will run too hot).

 

 

 

 

 

 

 

4

Minimum motor speed error

 

 

 

rpm \ °C

-30

-25

-23.3

-20

-15

-10

-5

0

5

7.2

10

15

 

 

 

 

(If the refrigeration

system is

too heavily

loaded,

2,000

19.5

29.4

33.1

40.7

54.0

69.8

88.6

111

137

151

169

 

 

 

 

the motor cannot maintain minimum speed at

2,500

24.9

36.8

41.3

50.7

67.3

87.1

111

139

172

189

 

 

 

 

 

 

approximately 1,850 rpm).

 

 

 

3,000

27.7

39.9

44.9

55.9

76.1

101

130

164

 

 

 

 

3

Motor start error

 

 

 

 

3,500

32.2

44.2

49.7

62.2

86.0

115

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(The rotor is blocked or the differential pres-sure in

Power consumption

 

 

 

 

 

12V DC, static cooling

watt

 

 

 

 

 

 

 

the refrigeration system is too high (>5 bar)).

 

rpm \ °C

-30

-25

-23.3

-20

-15

-10

-5

0

5

7.2

10

15

2

Fan over-current cut-out

 

 

 

2,000

17.6

23.4

25.3

28.7

33.6

38.3

43.0

48.0

53.4

56.0

59.5

 

 

(The fan loads the electronic unit with more than

2,500

23.3

30.9

33.3

37.8

44.1

50.2

56.2

62.3

68.7

71.7

 

 

 

1Apeak).

 

 

 

 

 

 

3,000

29.9

36.0

38.3

43.0

50.7

58.7

66.8

74.8

 

 

 

 

1

Battery protection cut-out

 

 

 

3,500

36.0

42.8

45.4

50.8

59.5

68.9

78.5

 

 

 

 

 

 

(The voltage is outside the cut-out setting).

 

Current consumption (for 24V applications the following must be halfed)

 

A

Compressor speed

 

 

 

 

rpm \ °C

-30

-25

-23.3

-20

-15

-10

-5

0

5

7.2

10

15

 

 

 

 

2,000

1.5

2.0

2.1

2.4

2.8

3.2

3.6

4.0

4.5

4.67

5.0

 

Electronit unit

 

Resistor

Motor

Control

2,500

1.9

2.6

2.8

3.2

3.7

4.2

4.7

5.2

5.8

5.98

 

 

Code number

 

(R1) [Ω]

speed

circuit

3,000

2.5

3.0

3.2

3.6

4.2

4.9

5.6

6.2

 

 

 

 

calculated

 

current

3,500

3.0

3.6

3.8

4.3

5.0

5.7

6.5

 

 

 

 

 

 

 

 

values

[rpm]

[mA]

COP (EN 12900 Household/CECOMAF)

 

 

12V DC, static cooling

W/W

 

 

 

0

2,000

 

5

rpm \ °C

-30

-25

-23.3

-20

-15

-10

-5

0

5

7.2

10

15

101N0210

 

277

2,500

 

4

2,000

0.90

1.02

1.06

1.15

1.31

1.48

1.67

1.87

2.08

2.17

2.29

 

 

692

3,000

 

3

 

 

 

 

 

2,500

0.87

0.97

1.01

1.09

1.24

1.41

1.60

1.80

2.02

2.12

 

 

 

 

 

1523

3,500

 

2

3,000

0.75

0.90

0.95

1.06

1.22

1.39

1.58

1.78

 

 

 

 

Wire Dimensions DC

 

 

 

 

3,500

0.73

0.84

0.89

1.00

1.17

1.36

1.55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size

 

Max. length*

 

Max. length*

COP (ASHRAE LBP)

 

 

 

 

 

12V DC, static cooling

W/W

 

 

-23.3

-20

-15

-10

-5

Cross

AWG

 

12V operation

24V operation

rpm \ °C

-30

-25

0

5

7.2

10

15

section

 

 

 

 

 

 

 

2,000

1.10

1.25

1.31

1.42

1.61

1.82

2.06

2.31

2.57

2.70

2.84

 

 

 

 

 

 

 

 

 

[mm2]

[Gauge]

[m]

[ft.]

 

[m]

[ft.]

2,500

1.07

1.19

1.24

1.34

1.53

1.74

1.97

2.23

2.50

2.63

 

 

 

 

 

2.5

12

 

2.5

8

 

5

16

3,000

0.93

1.11

1.17

1.30

1.50

1.72

1.95

2.20

 

 

 

 

 

 

3,500

0.89

1.03

1.09

1.23

1.44

1.68

1.91

 

 

 

 

 

4

12

 

4

13

 

8

26

Test conditions

 

 

EN 12900/CECOMAF

 

ASHRAE LBP

 

6

10

 

6

20

 

12

39

 

 

 

 

10

8

 

10

33

 

20

66

Condensing temperature

 

 

55°C

 

 

54.4°C

 

 

 

 

*Length between battery and electronic unit

Ambient temperature

 

 

 

32°C

 

 

32°C

 

 

 

 

 

 

 

 

 

Suction gas temperature

 

 

32°C

 

 

32°C

 

Accessories for BD35F-HD

 

Code number

Liquid temperature

 

 

 

no subcooling

 

 

32°C

 

 

 

 

 

 

 

 

Bolt joint for one compressor Ø:16 mm

118-1917

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bolt joint in quantities

Ø:16 mm

118-1918

 

 

 

 

 

 

 

 

 

 

 

 

 

Snap-on in quantities

Ø:16 mm

118-1919

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote kit (without cable)

 

 

105N9210

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard automoblie fuse

12V: 30A

Not

 

 

 

 

 

 

 

 

 

 

 

 

 

DIN 7258

 

 

 

24V: 15A

deliverable

 

 

 

 

 

 

 

 

 

 

 

 

 

Main switch

 

 

min. 30A

from Secop

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

Manufactured by Secop for Danfoss - DEHC.ED.100.F4.02 / 520N1476