Danfoss BD35F-B Data sheet

Barcode on white backgroun
Datasheets
BD35F-B
Direct Current Compressor
Bus-optimized
R134a, 12/24V DC & 100-240V AC 50/60Hz
General
Code number (without electronic units) 101Z0205 Approvals
Electronic unit 12/24V DC - Standard 101N0212, 30 pcs: 101N0213
Electronic unit 12/24V DC - AEO 101N0340, 30 pcs: 101N0341 UL
Electronic unit 12/24V DC & 100-240V AC 50/60Hz 101N0510, 28 pcs: 101N0511 UL / VDE
Electronic unit 12/24V DC - Automotive
Compressors on pallet 150
Application
Application LBP/MBP/HBP
Evaporating temperature °C -30 to 0 (10)
Voltage range DC VDC 9.6 - 17 / 21.3 - 31.5
Voltage range AC V/Hz 100 - 240 / 50/60
Max. condensing temperature continuous (short)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Application LBP MBP HBP
32°C S S S
38°C S S S
43°C S S S
Remarks on application: Fan cooling F
Special version of the BD35F optimized for rough vehicle motions, especially in buses.
Motor
Motor type variable speed
Resistance, all 3 windings (25°C) 2.2
depending on application and speed.
1
101N0650, 30 pcs: 101N0651 UL
°C 60 (70)
BD35F-B
only with BD controller
Blue stripe
Grey background Country of origin or manufacturer
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
= not applicable in this area
R134a
serial number
Made by Secop
101Z
0205
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 300
Free gas volume in compressor cm
Weight - Compressor/Electronic unit kg 4.3 / 0.19 (Standard)
Standard battery protection settings
Voltage 12V 24V
Cut out VDC 10.4 22.8
Cut in VDC 11.7 24.2
Dimensions
Height mm A 137
Suction connector location/I.D. mm | angle C 6.2 | 40°
Process connector location/I.D. mm | angle D 6.2 | 45°
Discharge connector location/I.D. mm | angle E 5.0 | 21°
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20 Remarks:
© Danfoss | DCS (CC) | 2016.11
3
3
3
(refer to electronic unit Instructions for optional settings)
B 135 B1 128 B2 73
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
2.00
150 (polyolester)
870
DEHC.ED.100.I9.02 | 1
Capacity (EN 12900 Household/CECOMAF) 12V DC, static cooling watt
Danf already on order pro All trademarks in this material are property of the respec
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 16.0 23.8 26.7 32.9 43.7 56.5 71.8 89.8 111 121 136 2,500 18.8 29.9 33.9 41.9 55.4 71.1 89.8 112 139 152 3,000 22.4 32.9 37.1 46.1 62.5 82.2 106 133 3,500 27.0 35.9 40.2 50.3 69.8 93.9 122
Capacity (ASHRAE LBP) 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 20.0 29.8 33.4 41.2 54.6 70.6 89.7 112 139 152 169 2,500 23.6 37.5 42.4 52.4 69.2 88.8 11 2 140 173 190 3,000 28.1 41.3 46.5 57.9 78.2 103 132 166 3,500 33.9 45.1 50.5 63.1 87.3 117 153
Power consumption 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 17.7 22.9 24.6 27.7 32.2 36.7 41.3 46.2 51.6 54.3 57.8 2,500 22.1 29.7 32.0 36.3 42.4 48.1 53.8 59.7 66.1 69.1 3,000 29.3 34.6 36.7 41.2 48.7 56.5 64.5 72.0 3,500 34.5 41.3 43.8 48.9 57.3 66.2 75.4
Current consumption
(for 24V applications the following must be halfed) A
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 1.4 1.9 2.0 2.3 2.7 3.1 3.4 3.8 4.3 4.5 4.8 2,500 1.8 2.5 2.7 3.0 3.5 4.0 4.5 5.0 5.5 5.8 3,000 2.4 2.9 3.1 3.4 4.0 4.7 5.3 6.0 3,500 2.9 3.4 3.6 4.1 4.8 5.5 6.3
COP (EN 12900 Household/CECOMAF) 12V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 0.90 1.04 1.09 1.19 1.36 1.54 1.74 1.94 2.15 2.24 2.35 2,500 0.85 1.01 1.06 1.15 1.31 1.48 1.67 1.88 2.10 2.20 3,000 0.76 0.95 1.01 1.12 1.28 1.45 1.64 1.85 3,500 0.78 0.87 0.92 1.03 1.22 1.42 1.62
COP (ASHRAE LBP) 12V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,000 1.13 1.30 1.36 1.49 1.70 1.93 2.18 2.44 2.70 2.81 2.95 2,500 1.07 1.26 1.33 1.45 1.64 1.86 2.10 2.36 2.64 2.77 3,000 0.96 1.19 1.27 1.41 1.61 1.83 2.06 2.32 3,500 0.98 1.09 1.15 1.29 1.53 1.78 2.03
Test conditions with electronic units EN 12900/CECOMAF ASHRAE LBP
Condensing temperature Ambient temperature 32°C 32°C Suction gas temperature 32°C 32°C Liquid temperature no subcooling 32°C
101N0212
101N0650
55°C 54.4°C
Accessories for BD35F-B Code number
Bolt joint for one comp. Ø:16 mm 118-1917 Bolt joint in quantities Ø:16 mm 118-1918 Snap-on in quantities Ø:16 mm 118-1919 Remote kit (without cable) 105N9210 One Wire/LIN gateway 105N9501
DC usage:
AC usage:
Automoblie fuse, DIN 7258 12V: 15A | 24V: 7.5 A Main switch
min. 20A Fuse, 100-240V Main switch
min. 6A
Not
deliverable
from Secop
Compressor speed
Electronit unit Resistor
(R1)[Ω]
Code number
calculated
values [rpm]
101N0212 101N0510 101N0650
0 2,000 5
277 2,500 4
692 3,000 3
Motor
speed
Control
circuit
current
[mA]
1523 3,500 2
0 AEO 6
101N0340 with AEO
173 2,000 5
450 2,500 4
865 3,000 3
1696 3,500 2
In AEO (Adaptive Energy Optimizing) speed mode the BD com­ressor will always adapt its speed to the actual cooling demand.
Wire dimensions DC
Size Max. length* Max. length*
Cross AWG 12V operation 24V operation
section
2
] [Gauge] [m] [ft.] [m] [ft.]
[mm
2.5 12 2.5 8 5 16 4 12 4 13 8 26 6 10 6 20 12 39
10 8 10 33 20 66
*Length between battery and electronic unit
Wire dimensions AC
Cross section min. 0.75 mm
Operational errors
Error code
or LED
ashes
Thermostat failure
6
(If the NTC thermistor is short-circuit or has no connection).
Thermal cut-out of electronic unit
5
(If the refrigeration system has been too hea vi ly loaded, or if the ambient tem pe ra ture is high, the electronic unit will run too hot).
Minimum motor speed error
4
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,850 rpm).
Motor start error
3
(The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)).
Too many start attempts or fan over current
2
(Too many compressor or fan starts in short time or fan current higher than 0.5A
Battery protection cut-out
1
(The voltage is outside the cut-out setting).
Can be read out in the software
2
or AWG 18
Error type
TOOL4COOL®
).
avg
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2016.11 DEHC.ED.100.I9.02
Loading...