Introduction The ARV22 is an automatic by-pass control valve
intended for use in domestic central heating systems. Its function is to allow a minimum  ow to be maintained through the boiler as the water  ow through the pump is reduced by, for example, radiator thermostats. The ARV22 automatically opens and closes depending on system load.
When the radiator thermostats are open and calling for heat the ARV22 remains closed, allowing the full boiler/pump output to circulate; as radiator thermostats start to close so the ARV22 opens to allow a  ow through the by-pass.
The ARV22 automatic by-pass control valve must be adjusted at the time of installation to suit the central heating system.
The ARV22 will protect most domestic boilers against low  ow rates.
O Automatic operation O Supplied complete with ¾" BSP and 22mm
compression  ttings
O Ensures quiet operation O Suitable for domestic system with boiler sizes
up to 22 kW
Application
Order Code
Feed and Expansion Tank
Mains
Water
Cylinder
Thermostat
Boiler
Type Code Number
ARV22 099-1063
Part No. 380v06 04/08
Wiring Centre
ARV22
Heatplan control system utilises two 2-port H Series valves
Programmer
Zone
Valves
Room
Thermostat
1
Datasheet ARV22 Automatic By-Pass Valve
Speci cations
Capacity
Maximum Working Pressure 4.0 Bar
Maximum Working Temperature 100°C
Setting Range 10 - 50 kPa
Connection Size (inlet) 22mm
Connection Size (outlet) 22mm
70
60
50
40
kPa
30
20
10
0
0.00
0.05
0.10
ARV22 Setting Diagram
0.15
0.20 0.25 Litres/second
0.30
0.35
0.40
0.45 0.50
0.55
Capacity
The valve can be installed in any attitude. The  ow through the valve must be as per the direction of the  ow arrow stamped into the valve body. The valve is supplied with two 22mm compression couplings for use with 22mm copper tubing. Dimensions are shown right. If replacing a previous ARV22 the existing pipework may need a small adjustment to  t a new ARV22.
Setting Instructions
Before running the boiler, set the ARV22 to the maximum setting by turning the white knob clockwise until the knob is mechanically stopped. Ensure that the radiator thermostats are set to their normal control temperature. Turn on the boiler, and allow the temperature to stabilise, at this stage the ARV22 will be closed. Turn the ARV22 knob slowly counter-clockwise until the valve begins to open, this can be monitored by feeling the temperature of the outlet connection of the valve. At this stage turn the knob clockwise half a turn to complete the setting process. Once the right setting has been established the setting can be locked using the transparent cap.
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.