Danfoss AB-QM DN 40-100 Operating guide

Operating Guide
AB-QM DN 40-100
DN 40/50 DN 50 DN 65-100
AB-QM DN 40-100 / 73693790
AME 435 QM
IP 54
DN 40/50 DN 50
 
DN 65-100
+
AME 435 QM
+
Code No.: 003Z0695
AQ146886477233en-010601 | 1© Danfoss | 2021.08
AB-QM DN 40-100
Shut o
Δp max = 16 bar
DN 40, DN 50
DN 65-100
Δp max = 16 bar
12 N m
Setting
Note: best before applying pressure
DN 40/50
DN 65-100
3 Nm
8 mm
50 mm
Max. 25 Nm 1 turn = 10%
+
42 mm
Max. 25 Nm 1 turn = 10%
+
Resetting
DN 40-100
max 1 turn
3 mm
Max. 25 Nm 1 turn = 10%
3 mm
AQ146886477233en-010601 2 | © Danfoss | 2021.08
AB-QM DN 40-100
Q
Locking
DN 40/50
DN 65-100
3 mm
3 mm
Measuring
Δp=p1-p3
p1-p2
DN 40/50
Flow direction
Δp=p1-p3
p1-p2
DN 65-100
Q ≠ const
Pump optimization
Q = const
∆p
min
P1 - P3
© Danfoss | 2021.08 | 3AQ146886477233en-010601
AB-QM DN 40-100
–10…95 °C
max.
a (6 bar)
DN 40 L/h L/s GPM
20% 1,500 0.416 6.6
25% 1,875 0.520 8.3
30% 2,250 0.625 9.9
35% 2,625 0.729 11.6
40% 3,000 0.833 13.2
45% 3,375 0.937 14.9
50% 3,750 1.041 16.5
55% 4,125 1.145 18.2
60% 4,500 1.250 19.8
65% 4,875 1.354 21.5
70% 5,250 1.458 23.1
75% 5625 1.562 24.8
80% 6,000 1.666 26.4
85% 6,375 1.770 28.1
90% 6,750 1.875 29.7
95% 7,125 1.979 31.4
100% 7,500 2.083 33.0
Note: 1 turn = 10%
DN 80
40% 11,200 3.11 49.3 16,000 4.44 70.5
45% 12,600 3.50 55.5 18,000 5.00 79.3
50% 14,000 3.89 61.6 20,000 5.56 88.1
55% 15,400 4.23 67.8 22,000 6.11 96.9
60% 16,800 4.67 74.0 24,000 6.67 105.7
65% 18,200 5.10 80.1 26,000 7.22 114.5
70% 19,600 5.44 86.3 28,000 7.78 123.3
75% 21,000 5.83 92.5 30,000 8.33 132.2
80% 22,400 6.22 98.6 32,000 8.89 141.0
85% 23,800 6.61 104.8 34,000 9.44 149.8
90% 25,200 7.00 111.0 36,000 10.00 158.6
95% 26,600 7.39 117.1 38,000 10.56 167.4
100% 28,000 7.78 123.3 40,000 11.11 176.2
Note: 1 turn = 10%
Flow High Flow
L/h L/s GPM L/h L/s GPM
DN 50 L/h L/s GPM
40% 5,000 1.386 22.0
45% 5,625 1.562 24.8
50% 6,250 1.736 27.5
55% 6,875 1.909 30.3
60% 7,500 2.083 33.0
65% 8,125 2.256 35.8
70% 8,750 2.430 38.50
75% 9,375 2.604 41.3
80% 10,000 2.777 44.0
85% 10,625 2.951 46.8
90% 11,250 3.125 49.5
95% 11,875 3.298 52.3
100% 12,500 3.472 55.0
Note: 1 turn = 10%
PN 16
Δp
= 600 kP
DN 65
40% 8,000 2.22 35.2 10,000 2.78 44.0
45% 9,000 2.50 39.6 11,250 3.13 49.5
50% 10,000 2.78 44.0 12,500 3.47 55.0
55% 11,000 3.06 48.4 13,750 3.82 60.5
60% 12,000 3.33 52.8 15,000 4.17 66.0
65% 13,000 3.61 57.2 16,250 4.51 71.5
70% 14,000 3.89 61.6 17,500 4.86 77.0
75% 15,000 4.17 66.0 18,750 5.21 82.5
80% 16,000 4.44 70.4 20,000 5.56 88.0
85% 17,000 4.72 74.9 21,250 5.90 93.5
90% 18,000 5.00 79.3 22,500 6.25 99.0
95% 19,000 5.28 83.7 23,750 6.60 104.5
100% 20,000 5.56 88.1 25,000 6.94 110.0
Note: 1 turn = 10%
DN 100
40% 15,200 4.22 67.0 23,600 6.56 104.0
45% 17,100 4.75 75.3 26,550 7.38 117.0
50% 19,000 5.28 83.7 29,500 8.19 130.0
55% 20,900 5.81 92.1 32,450 9.01 143.0
60% 22,800 6.33 100.4 35,400 9.83 155.9
65% 24,700 6.86 108.8 38,350 10.65 168.9
70% 26,600 7.39 117.2 41,300 11.47 181.9
75% 28,500 7.92 125.6 44,250 12.29 194.9
80% 30,400 8.44 133.9 47,200 13.11 207.9
85% 32,300 8.97 142.3 50,150 13.93 220.9
90% 34,200 9.50 150.7 53,100 14.75 233.9
95% 36,100 10.03 159.0 56,050 15.57 246.9
100% 38,000 10.56 167.4 59,000 16.39 259.9
Note: 1 turn = 10%
Flow High Flow
L/h L/s GPM L/h L/s GPM
Flow High Flow
L/h L/s GPM L/h L/s GPM
ІМПОРТЕР: UA: ТОВ з ІІ «Данфосс ТОВ», вул. Вікентія Хвойки, 15/15/6, м. Київ, 04080, Україна
73693790 / AQ146886477233en-0106014 | © Danfoss | DCS-S/SI | 2021.08
Loading...