Operating Guide
AB-PM DN 40-100
①
AB-PM DN 40-100 / 73694360
G /
003Z0690
DN 40 -50 DN 65-100
Mounting of handle
❶
❷
Installation
Flow
direction
①
Impulse tube connection
DPCV
003L8151
②
③
003L8151
003Z0695
②
④
③
PIBCV
003L8151
max
p
400kPa(4bar)
10 mm
M
2 Nm
max
⑤
PIBCV
Note: Best done before pressurizing the system
➌
Setting: Flow %
Impulse tube
connected to flow
3 mm
max 1 turn
connected to return
Note: 1 turn = 10%
Impulse tube
Alternative
AQ262437753445en-010201 | 1© Danfoss | 2021.09
003L8151
Max. 25 Nm
003Z0691
+
AB-PM DN 40-100
Setting: Δp setting
❹
Manual shut-off
❺
Note: Best done before pressurizing the system
5 5
(turns)
0 turns
Clockwise: Close
Counter-Clockwise: Open
DN 65 80 100
13
n
Δp setting
Min. setting
❻
P
3
Measuring
P1-P
3
P1-P
2
P
P
2
1
P
0
-P
=P
p
n
(turns)
0 turns
3
0
a
Δp setting
Min. setting
003L8151
-P
=P
p
1
0
r
Mounting actuator
➐
ІМПОРТЕР:
UA: ТОВ з ІІ «Данфосс ТОВ», вул. Вікентія Хвойки, 15/15/6, м. Київ, 04080, Україна
P0-P
pv=P1-P
1
3
+
AME 435 QM
73694360 / AQ262437753445en-0102012 | © Danfoss | DCS-S/SI | 2021.09