Features and Unit Parts Identification ............................................................................................... 6
Key Pad Functions ....................................................................................................................................... 7
Thank you for choosing this Danby® appliance to provide you and your family with all of the
“Home Comfort” requirements for your home, cottage or office. This Owner’s Manual will provide you with valuable information necessary for the proper usage, care and maintenance of
your new appliance. If properly maintained, your Danby® appliance will give you many years
of trouble free operation. Please take a few moments and read the instructions thoroughly
and familiarize yourself with all of the operational aspects of this appliance.
This unit can be conveniently moved from room to room within your home and set-up in
just minutes.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page,
along with the following information which is located on the manufacturers nameplate
located on the rear wall of the water tank compartment.
Model Number: DDR3008EE, DDR4588EE, DDR6588EE
Serial Number:
Date of Purchase:
Dealer’s Name and Address:
This information will be required if your unit requires servicing and/or for general inquiries.
To contact a Customer Service Representative, telephone
1-800-26-DANBY (1-800-263-2629)
Keep these instructions for future reference.
This symbol denotes a caution or warning
CAUTION
Do not leave this unit unattended or operate in an
area where people or animals may not be able to
react quickly. A failed unit may cause over-heating
reaulting in personal injury or property damage.
3
WARNING - IMPORTANT NOTICES
NOTE: The WARNING instructions issued in this manual are not meant to cover all possible
conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors that cannot be built into all appliances. These factors must
be supplied by the person(s) installing, maintaining, or operating the appliance. Failure to
install, maintain, and/or operate the equipment according to the manufacturer’s instructions
may result in conditions which can produce bodily injury and/or property damage. Contact
your dealer, service agent or the manufacturer about any problems or conditions you do
not fully understand. (For Danby Customer Service call 1 800 26 DANBY / 1 800 263 2629)
FOR YOUR SAFETY - To reduce the risk of fire or explosion, do not store or use gasoline or
other flammable vapors or liquids in the vicinity of this or any other appliance.
ELECTRICAL SERVICE INFORMATION - To reduce the risk of fire, electric shock or personal
injury, all wiring and grounding must conform with the latest edition of Local and National
Electrical Codes It is the customer’s responsibility to have the wiring and fuses checked by a
qualified electrician to make sure adequate electrical power is available.
This appliance is designed to operate on a separate branch, polarized, three-wire, effec
tively grounded, 120 Volt 60 Hertz (alternating current) circuit protected by a 15 ampere
fuse, equivalent fuse or circuit breaker.
The three-prong grounding plug on the power cord should be plugged directly into a
polarized three slot effectively grounded receptacle rated 110/120 V.A.C.
-
GROUNDING INSTRUCTIONS - Improper connection of the equipment-grounding conduc
tor can result in a risk of electrical shock. Check with a qualified electrician or serviceman if
you are in doubt as to whether your appliance outlets are properly grounded.
This appliance must be grounded. In the event of malfunction or breakdown, grounding
will reduce the risk of electrical shock by providing a path of least resistance for electrical
current. This appliance is equipped with a cord having an equipment-grounding conduc
tor and 3 prong grounding plug. The plug must be connected into an outlet that is properly
installed and grounded in the accordance with all local codes and ordinances.
Do not modify the plug provided with the appliance. If it will not fit the outlet, have a
proper outlet installed by a qualified electrician.
If the household electrical supply does not meet the above specifications, or if you are not
sure your home has an effective ground, have a qualified electrician or your local electrical
utility company check it and correct any problems.
-
-
4
Electrical Specifications
1. All wiring must comply with local and national
electrical codes and be installed by a qualified
electrician. If you have any questions regarding
the following instructions, contact a qualified
electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installation and opera
tion of this unit.
3. For your safety and protection, this unit is
grounded through the power cord plug when
plugged into a matching wall outlet. If you are
not sure whether the wall outlets in your home
are properly grounded, please consult a quali
fied electrician. DO NOT USE PLUG ADAPTERS
OR EXTENSION CORDS.
4. The manufacturers nameplate is located on the
rear wall of the water tank compartment. The
nameplate contains electrical and other techni
cal data specific to this unit.
5. To avoid the possibility of personal injury, always
disconnect the power supply before attempting
to clean and/or service the unit.
-
-
-
Unit Specifications:
Dehumidifying Capacity
Electrical Requirements115 Volts / 60 Hz
Power Input (watts)
Rated Amperage
• Dehumidifying
Air Flow Circulation - High Fan Speed
(Cubic Feet per Minute)
Type of Refrigerant
Water Tank Capacity
Operating Noise Level
Unit Dimensions Width / Height / Depth
Net Weight (kg / lbs.)
(Pints / Liters)
(Liters / Pints)
(dB A)
DDR3008EEDDR4588EDDR6588EE
30/14.245/21.365/30.7
490590735
4.45.26.5
115121158
R22
9.9/21
535360
15.0/22.8/13.2
16.5/36.417.1/37.718.6/41.0
NOTE: Specifications are subject to change without notice, for further improvements.
5
INSTALLATION
Location:
Select a suitable location, making sure you have easy
access to an electrical outlet. (avoid the use of
extension cords) If it is absolutely necessary to use an
extension cord, use an approved “air conditioner”
heavy duty extension cord only. (available at most local
hardware stores)
Select a suitable location making sure there are no
obstructions restricting airflow through the front air
intake grill. Maintain a minimum clearance of a least
20cm (8”) between adjacent walls and the back of the
unit to allow for proper air circulation and maximum
efficiency.
To obtain maximum operating efficiency from your
dehumidifier, the recommended (room ambient)
operating temperatures should be between 3ºC /
38ºF ~ 35ºC / 95ºF.
It is important to remember the efficiency of a
dehumidifier will be effected /influenced by the rate at
which new humid air (moisture) is allowed to infiltrate
the same space/area. To maintain efficiency, the
dehumidifier must be operated in an enclosed area.
Keep all doors and windows closed.
6
FEATURES
• Soft Touch (Electronic) Control Key Pads
• Auto-Sensing Humidity Control
• Adjustable Humidity Settings (35% ~ 80%)
• 2 Fan Speed Settings (High/Low)
• Delay Start Protection (compressor)
• Auto-Defrost (De-Icier)
• Full Bucket Indicator Light
• Easy Roll Casters (4)
• Front Mounted Water Tank (Removable)
• Direct Drain Option (Hose not Included)
• Quiet Operation
• Removable Air Filter
• Timer ( 3 / 6 / 12hr)
• Continuous Run
• Auto restart
Unit Parts Identification
Frant Panel
Drain Hose
Connector
Handle
Control Part for
consistency
Air Filter
Drain Hole
Drain Connector HolePower Cord
Water Bucket
7
KEY PAD FUNCTIONS.
1
7
6
5
1. LED (SETTING HUMIDITY): The LED
window displays the following information
independently;
A. Set Operating Relative Humidity Value.
B. Fuction indicator will light up;
(Fan Speed, Time, Self Dry)
2. ON/OFF Button : Each time this button is
pressed the unit turns On (adjacent indicator light
illuminates) or Off (adjacent indicator light is not
illuminated).
4
3
2
9
8
5.SELF DRY:Self Dry mode can be used to clean
the unit and removes excess humidity. You can
operate Self Dry mode when the dehumidifier is
powered on or off.
The inside moisture of the unit is removed in 30
minutes.
After 30 minutes, the product will power off.
6. CONTINUOUS: Used for Continuous
Dehumidifier Operation. (unit will run non-stop)
LED will be displayed [ ].
3. HUMIDITY DOWN: This button allows you to
decrease the relative humidity setting. Each time
this button is pressed the RH value setting is
decreased incrementally by 5%. (ranging from
80% ~ 35%)
4. HUMIDITY UP: This button allows you to
increase the relative humidity setting. Each time
this button is pressed the RH value setting is
increased incrementally by 5%. (ranging from
35% ~ 80%)
7.FAN SPEED: Press the Fan speed button to select
the fan speed (Hi/Low)
8.Timer: Press the Timer button to
timer to shut off in 3Hr 6Hr or 12Hr.
9.WATER FULL INDICATOR: This (red) light
illuminates under the following conditions;
A. When the internal water tank is not properly
installed inside the cabinet.
B. When the internal water tank is full. The
Water tank must be emptied and replaced
back in the cabinet before normal operating
conditions can resume.
select the off
Loading...
+ 17 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.