Danby DAC5111 Owner's Manual

Danby Products Limited, Ontario, Canada N1H 6Z9
Danby Products Inc., Findlay, Ohio, USA 45840
Model • Modèle • Modelo
• Owner’s Use and Care Guide
• Guide d’utilisation et soins de Propriètaire
AIR CONDITIONER CLIMATISEUR
DAC5111M / DAC5211M
Contents
CAUTION:
PRECAUTION:
Read and follow all safety rules and operat­ing instructions before first use of this prod­uct.
Veuillez lire attentivement les consignes de sécurité et les instructions d’utilisation avant l’utilisation initiale de ce produit.
CLIMATISEUR
Guide d'utilisation et d'entretien ........................
• Bienvenue
• Consignes de Sécurité Importantes
• Caractéristiques
• Installation
• Consignes d’utilisation
• Soins et Entretien
• Dépannage
• Garantie
2-11
AIR CONDITIONER
Owner’s Use and Care Guide .............................
• Welcome
• Important Safety Information
• Features
• Installation
• Operation Instructions
• Care and Maintenance
• Troubleshooting
• Warranty
Model • Modèle DAC5111M / DAC5211M
12-21
Welcome
Thank you for choosing a Danby appliance to provide you and your family with all of the “Home Comfort” requirements of your home, cottage, or office. This Owner’s Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturers nameplate on side of the unit.
NOTE: THIS UNIT IS NOT DESIGNED FOR “THROUGH-THE-WALL” INSTALLATION.
Model Number:
Serial Number:
Date of Purchase:
This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a Customer
Service Representative, call Danby TOLL FREE: 1-800-263-2629
2
WARNING
Improper connection of the grounding plug can result in risk of Fire, Electric Shock and/or injury to Persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is proplery grounded.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
ELECTRICAL SPECIFICATIONS
FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
1) All wiring must comply with local and national electrical codes and must
be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
2) Check available power supply and resolve any wiring problems
BEFORE installing and operating this unit.
3) This 115V air conditioner uses 4.8 or less nameplate amps and may
be used in any properly wired, general purpose household receptacle. See Table 1 for specifications for individual branch circuit.
4) For your safety and protection, this unit is grounded through the power
cord plug when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician.
5) The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters. See Table 2 for receptacle and fuse information. If it is necessary to use an extension cord to connect your air conditioner, use an approved “air conditioner” extension cord only (available at most local hardware stores).
6) The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit, above the power cord.
3
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
4.5 to 4.8 18
AWG- American Wire Gauge
*Based on copper wire at 60°C temperature rating.
TABLE 2
Receptacle and Fuse Types Rated Volts 125
Amps 15 Wall Outlet
Fuse Size 15 Time Delay Fuse Plug Type
(or Circuit Breaker)
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
ENERGY SAVING TIPS
FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
Your Danby appliance is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency.
1) Select a thermostat setting that suits your comfort needs and leave at
that chosen setting.
2) The air filter is very efficient in removing airborne particles. Keep the air
filter clean at all times. (usually cleaned every 2 weeks depending on indoor air quality).
3) Use drapes, curtains or shades to keep direct sunlight from penetrating
and heating the room, but do not allow drapes or curtains to obstruct the air flow around the unit.
4) Start your air conditioner before the outdoor air becomes hot and
uncomfortable, to avoid an initial period of discomfort while the unit is cooling off the room.
5) When outdoor temperatures are cool enough, use HIGH or LOW FAN
only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting.
4
Features
Air FIlter
Exterior Air Inlet
Cabinet
Interior Air Inlet
Control Panel
Interior Air Outlet
Installation Instructions
CAUTION
Because the compressor is located on the controls side of the unit (left side), this side will be heavier and more awkward to manipu­late. Inadequate support on control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended that you have someone assist you during the installation of this unit.
TOOLS NEEDED FOR INSTALLATION:
Screw Drivers: Phillips and flat head.
Power Drill: 1/8” (3.2mm) diameter drill bit.
Pencil
Measuring Tape
Scissors
Carpenters Level
NOTE: Save the shipping carton and packing materials for future storage or transportation. From carton, remove the plastic bag containing the installation hardware kit necessary for the installation of your air conditioner. Please check the contents of hardware kit against the corre­sponding model check list, prior to installation of the unit. See Fig. 1.
ELECTRIC SHOCK HAZARD
To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.
NOTE: Your Room Air Conditioner is designed for easy installtion in a single or double-hung window. This unit is NOT designed for vertical (slider type) windows and/or through-the-wall applications.
Installation Instructions
Fig. 1
INSTALLATION HARDWARE
LOCATION
A) This room air conditioner is designed to fit easily into a single or double
hung window. However, since window designs vary, it may be necessary to make some modifications for safe, proper installation.
B) Make sure window and frame are structurally sound and free from dry
and rotted wood.
C) For maximum efficiency, install the air conditioner on a side of the
house or building which favours more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit.
D) Provide sufficient clearance around the cabinet to allow for ample air
circulation through the unit (See Fig. 2). The rear of the unit should be outdoors and not in a garage nor inside a building. Keep unit as far away as possible from obstacles/obstructions and at least 30” above the floor or ground. Curtains and other objects within a room should be prevented from blocking the air flow.
E) Be certain the proper electrical outlet is within reach of the installation.
Use only a single outlet circuit rated at 15 amps. All wiring should be in accordance with local and national electrical codes.
F) DO NOT install unit where leakage of combustible gas is suspected.
Your air conditioner may fail to operate in air containing oils (including machine oils), sulfide gas, near hot springs, etc.
NOTE: Your unit is designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess conden­sation may cause basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrains or neigh­boring properties.
5
1/2in. (12.7mm) screws (7)
Safety Lock (1)
3/8in. (9.5mm) screws (4) *Factory installed
on some models
“L” Shaped mounting bracket (1)
* Factory installed
on some models
Sash bracket (2)
Adhesive Foam Seal(1)
Side Curtain LH (1)
Side Curtain RH (1)
LOCATION
Installation Instructions
Awning
Fence, wall, or other obstacle
Ground
Side Obstruction
20” Min
30” Min
20” Min
12” Min
Fig. 2
1) Assembly of the Upper Channel to Cabinet.
(Factory installed on some units)
• “L” Shaped Top Channel: Install the “L” shaped channel to the top of the
cabinet as shown in Fig. 3, using four (4) 3/8” screws.
2) Assembly of the Side Curtains to Cabinet.
• Extend the shutter from the shutter frame and slide it into the shutter tabs
on the side channel of the air conditioner, as shown in Fig. 4.
• Slide the shutters into the top (“L” Shaped) and bottom (“U” Shaped) channels. The shutters are identified (on frame) as left and right.
3) Completing the Installation
• Cut the foam (non adhesive) sealing strip to fit the area of the window sill
that the air conditioner will rest on.
3/8” screws
“L” shaped mounting bracket
“U” shaped Channel (Factory Installed)
Slide down into tabs
Shutter tabs
Shutter
Shutter frame
Fig. 3
Fig. 4
6
Loading...
+ 16 hidden pages