Daikin SRC-COA, SRC-HPA Operation manuals

OPERATING MANUAL
Models SRC-COA SRC-HPA
TEMP
TIMER
AUTO
HIGH MED LOW
SENSOR
Operating Manual
Handset Wired
Bedienungsanleitung
ON/OFF
COOL
FAN
FAN
MODE
DRY
SLEEPSWING
Verdrahtetes Handgerät
Mode D’emploi
Combiné Câblé
Bedieningsaanwijzing
Bedraad Handapparaat
Manual De Instrucciones
Auricular Alámbrico
Manuale Di Funzionamento
Ricevitore Cablato
Εγχειρίδιο Οδηγιών
Ασύρµατη Χειροσυσκευή
Manual De Funcionamento
Aparelho Conectado
Руководство По Зксплуатации
Проводное Дистанционное Управление
Kullanım Kılavuzu Kablolu Kumanda
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
Portugues
Pycckий
TürkçeTürkçe
Türkçe
TürkçeTürkçe
Part No.: R08019029812 OM-SLM-1208(1)-DAIKIN
OM-SLM-1206(1)-Daikin 2/12/09, 4:40 PM26
OPERATING INSTRUCTION
1. TEMPERATURE (Seven Segments)
• To indicate the ambient temperature set by the user.
2. MODE
• To indicate the selected operating mode: HEAT & DRY / COOL / FAN (LED green / yellow / red).
3. VENTILATION SPEED
• To indicate the selected ventilation speed: LOW / MED / HIGH
• For U1-SB125 only have single speed: HIGH.
4. AUTO SELECTION
• Automatic selection for speed, whereby the speed is automatically adjusted according to the room temperature.
5. FAN AND VENTILATION MODE
• Press the fan button to set the desired selection.
6. OPERATION SELECTION MODE
• Press the mode button to select the type of operation mode.
• Cooling unit: COOL, DRY, FAN.
• Heat pump unit: AUTO, COOL, DRY, FAN, HEAT. The Auto mode is unavailable for Chilled Water (CW) 2 pipe system. It is available for Chilled Water (CW) 4 pipe system.
7. TEMPERATURE SETTING
• Set the desired temperature.
• Press or button to increase or decrease the set temperature. The setting range is between 16°C to 30°C (60°F to 80°F).
8. TIMER SWITCH SETTING
• Press the set button to activate the switch timer of the air conditioner unit (the setting range is between 1 to 10 hours). The unit will be at ON or OFF state in function of operating mode.
9. “SLEEP ” FUNCTION
• Press the sleep button to select the sleep function. This function cannot be selected if the air conditioner unit is operating under FAN mode only or dry mode. For SLEEP function operating under COOL mode, the set temperature increases by 0.5°C after 30 minutes, another 0.5°C after the next 30 minutes and 1°C after the following 1 hour. When the unit is operating under heating mode, the set temperature decreases by 1°C after 30 minutes, another 1°C after the next 30 minutes and 1°C after the following 1 hour.
10. “ON/OFF” SWITCH
• Press once, the air conditioner unit starts.
• Press again, the air conditioner unit stops.
11. IR RECEIVER
12. AUTOMATIC AIR SWING (OPTIONAL)
• Press the SWING button to activate the automatic air swing function.
• To distribute the air to a specific direction, press the button and wait until the louver move to the desired direction and press the SWING button once again.
Error Seven Segments
Room Sensor missing/Short E1 blinking Indoor coil sensor missing/Short E2 blinking Outdoor coil sensor missing/Short E3 blinking Compressor overload E4 blinking Outdoor abnormal compressor E5 blinking
overload trip or gas leak Pump fault E6 blinking
NOTE:
• Function 3, 4, 5, 12 are not applicable for Roof Top models.
• Function 6 (Dry Mode) is not applicable for Roof Top models.
• Function 12 (Automatic Air Swing) mode is not applicable for ducted models.