Daikin FTXZ25NVMM, RXZ35NVM, FTXZ35NVMM, RXZ50NVM, FTXZ50NVMM Engineering Data

...
EDMY041425
Split Type Air Conditioners - Heat Pump
FTXZ-N Series
EDMY041425
Split Type
Air Conditioners
FTXZ-N Series
FTXZ25NVMM
Heat Pump
FTXZ35NVMM FTXZ50NVMM
1. Power Supply..........................................................................................2
2. Functions.................................................................................................3
3. Specifications..........................................................................................4
4. Dimensions .............................................................................................6
4.1 Indoor Unit................................................................................................6
4.2 Outdoor Unit .............................................................................................6
5. Wiring Diagrams......................................................................................7
5.1 Indoor Unit................................................................................................7
5.2 Outdoor Unit .............................................................................................7
6. Piping Diagrams......................................................................................8
6.1 Indoor Unit................................................................................................8
6.2 Outdoor Unit .............................................................................................8
7. Capacity Tables ......................................................................................9
8. Operation Limit......................................................................................12
9. Sound Level ..........................................................................................13
9.1 Measuring Location ................................................................................13
9.2 Indoor Unit..............................................................................................14
9.3 Outdoor Unit ...........................................................................................15
10.Electric Characteristics..........................................................................16
11.Installation Manual ................................................................................17
12.Operation Manual..................................................................................33
13.Optional Accessories ............................................................................77
13.1 Option List ..............................................................................................77
13.2 <KRP413AB1S> Wiring Adaptor for Timer Clock /
Remote Controller ..................................................................................78
13.3 <KRP928BB2S> Interface Adaptor for DIII-NET
(Residential Air Conditioner) ..................................................................82
13.4 <KPW937D4> Air Direction Adjustment Grille .......................................85
RXZ25NVM RXZ35NVM RXZ50NVM
Split Type Air Conditioners FTXZ-N Series 1
Power Supply EDMY041425

1. Power Supply

Indoor Unit Outdoor Unit Power Supply
FTXZ25NVMM RXZ25NVM
FTXZ35NVMM RXZ35NVM
FTXZ50NVMM RXZ50NVM
Note: Power Supply Intake ; Outdoor Unit
220 - 230 - 240 V, 50 Hz
1
φ,
1
220 - 230 V, 60 Hz
φ,
2 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Functions

2. Functions

Category Functions
FTXZ25/35/50NVMM
Basic Function PAM control
Swing compressor Reluctance DC motor Standby electricity saving
Operation URURU HUMIDIFY operation Air filter (pre-filter)
SARARA DRY operation DRY COOLING operation Programme dry operation — AUTO operation
Comfortable Airflow
Living Convenience
Timer 24-hour ON/OFF TIMER operation
Power-airflow flaps Angle louvres Auto-swing (up and down) Auto-swing (right and left) 3-D airflow 3-area INTELLIGENT EYE operation COMFORT AIRFLOW operation Mould proof indoor heat exchanger Comfort airflow with INTELLIGENT EYE
sensor Circulation airflow BREEZE airflow Auto fan speed Indoor unit quiet operation FAN ONLY operation Inverter POWERFUL operation ECONO operation
OUTDOOR UNIT QUIET operation
AUTO OFF operation INFORMATION display CHILDPROOF LOCK R/C with back light Remote controller setting memory Indoor unit lamp brightness setting Indoor unit ON/OFF button Auto-restart (after power failure)
DAILY ON/OFF TIMER operation WEEKLY TIMER operation — COUNTDOWN OFF TIMER operation NIGHT SET mode — COMFORT SLEEP TIMER operation QUICK HEATING TIMER operation
Note: z
: Available
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
Category Functions
RXZ25/35/50NVM
Health and Cleanliness
Comfortable Temperature
Installation and Service
Titanium apatite photocatalytic air-purifying filter
Photocatalytic air-purifying and deodorising filter
Air supply filter — MOISTURISING operation
FLASH STREAMER AIR PURIFYING operation
FRESH AIR SUPPLY VENTILATION operation
MOULD PROOF operation CLEANING FILTER operation Filter cleaning indicator (remote controller) — Hydrophilic coated indoor heat exchanger
Washable upper grille
Wipe-clean flat panel Hot-start function
Quick warming function (preheating operation)
Automatic defrosting Installation position setting Multi-split / split type compatible indoor
unit Either side drain (right or left)
Anti-corrosion treatment of outdoor heat exchanger
Self-diagnosis display (remote controller) Home automation correspondence
— : Not available
FTXZ25/35/50NVMM
RXZ25/35/50NVM
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
Split Type Air Conditioners FTXZ-N Series 3
Specifications EDMY041425

3. Specifications

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Model
Capacity Rated (Min. ~ Max.)
Running Current (Rated) A 2.1 - 2.0 - 2.0 / 2.1 - 2.0 2.9 - 2.8 - 2.7 / 2.9 - 2.8 3.2 - 3.0 - 2.9 / 3.2 - 3.0 4.6 - 4.4 - 4.3 / 4.6 - 4.4 Power Consumption Rated
(Min. ~ Max.)
Power Factor (Rated) %
COP Rated (Min. ~ Max.) W/W 5.70 (5.45 ~ 4.43) 5.81 (6.00 ~ 3.73) 5.07 (5.45 ~ 3.98) 5.00 (6.00 ~ 3.56) Piping
Connections Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 30 30 Max. Interunit Height Difference m 12 12 Chargeless m Amount of Additional Charge of
Refrigerant
Indoor Unit FTXZ25NVMM FTXZ35NVMM
Front Panel Colour Whit e Whit e
Airflow Rate
Fan
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards Air Filter Auto cleaning filter Auto cleaning filter
Running Current (Rated) A
Power Consumption (Rated) W 30 - 30 - 30 / 30 - 30 30 - 30 - 30 / 30 - 30 30 - 30 - 30 / 30 - 30 30 - 30 - 30 / 30 - 30
Power Factor (Rated) %
Temperature Control Microcomputer Control Microcomputer Control Dimensions (H × W × D) mm 295 × 798 × 370 295 × 798 × 370 Packaged Dimensions (H × W × D) mm 434 × 865 × 361 434 × 865 × 361 Weight (Mass) kg 15 15 Gross Weight (Gross Mass) kg 19 19 Sound Pressure
Level Sound Power Level (H) dB 54 56 57 57
Outdoor Unit RXZ25NVM RXZ35NVM
Casing Colour Ivory White Ivory White
Compressor
Refrigerant Oil
Refrigerant
Airflow Rate
Fan
Running Current (Rated) A 2.0 - 1.9 - 1.9 / 2.0 - 1.9 2.8 - 2.7 - 2.6 / 2.8 - 2.7 3.1 - 2.9 - 2.8 / 3.1 - 2.9 4.5 - 4.3 - 4.2 / 4.5 - 4.3 Power Consumption (Rated) W 400 590 650 970
Power Factor (Rated) %
Starting Current A 2.9 4.6 Dimensions (H × W × D) mm 595 × 795 × 300 595 × 795 × 300 Packaged Dimensions (H × W × D) mm 633 × 920 × 392 633 × 920 × 392 Weight (Mass) kg 43 43 Gross Weight (Gross Mass) kg 48 48 Sound Pressure Level (H) dB(A) 46 46 48 48 Sound Power Level (H) dB 59 59 61 61 Drawing No. 3D086954 3D086955
Indoor Unit FTXZ25NVMM FTXZ35NVMM
Outdoor Unit
kW 2.45 (0.6 ~ 3.9) 3.6 (0.6 ~ 7.5) 3.45 (0.6 ~ 5.3) 5.0 (0.6 ~ 9.0)
Btu/h 8,400 (2,000 ~ 13,300) 12,300 (2,000 ~ 25,600) 11,800 (2,000 ~ 18,100) 17,100 (2,000 ~ 30,700)
kcal/h 2,110 (520 ~ 3,350) 3,100 (520 ~ 6,450) 2,970 (520 ~ 4,560) 4,300 (520 ~ 7,740)
W 430 (110 ~ 880) 620 (100 ~ 2,010) 680 (110 ~ 1,330) 1,000 (100 ~ 2,530)
Liquid mm Gas mm
Cooling Heating Cooling Heating
93.1 - 93.5 - 89.6 /
93.1 - 93.5
RXZ25NVM RXZ35NVM
6.4
φ
9.5
φ
97.2 - 96.3 - 95.7 /
97.2 - 96.3
96.6 - 98.6 - 97.7 /
96.6 - 98.6
6.4
φ
9.5
φ
98.8 - 98.8 - 96.9 /
98.8 - 98.8
——
g/m
H M 7.5 (265) 8.6 (303) 8.4 (295) 9.2 (324) L 5.3 (188) 6.7 (236) 5.6 (197) 6.9 (245) SL 4.0 (141) 4.8 (168) 4.0 (141) 4.8 (168) Type Cross Flow Fan Cross Flow Fan Motor Output W 30 30 Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 38 / 33 / 26 / 19 39 / 35 / 28 / 19 42 / 35 / 27 / 19 42 / 36 / 29 / 19
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type Model 2YC40DXD 2YC40DXD Type FW68DA FW68DA Charge L 0.405 0.405 Type R-32 R-32 Charge kg 1.34 1.34 H L 22.5 (794) 16.2 (571) 22.5 (794) 16.2 (571) Type PZ440 PZ440 Motor Output W 71 71
m³/min
(cfm)
m³/min
(cfm)
10.7 (379) 11.7 (415) 12.1 (428) 13.3 (469)
0.14 - 0.14 - 0.13 /
0.14 - 0.14
97.4 - 93.2 - 96.2 /
97.4 - 93.2
31.0 (1,093) 28.3 (999) 34.4 (1,216) 31.5 (1,113)
90.9 - 91.5 - 87.7 /
90.9 - 91.5
——
0.14 - 0.14 - 0.13 /
0.14 - 0.14
97.4 - 93.2 - 96.2 /
97.4 - 93.2
95.8 - 95.0 - 94.6 /
95.8 - 95.0
0.14 - 0.14 - 0.13 /
0.14 - 0.14
97.4 - 93.2 - 96.2 /
97.4 - 93.2
95.3 - 97.5 - 96.7 /
95.3 - 97.5
0.14 - 0.14 - 0.13 /
0.14 - 0.14
97.4 - 93.2 - 96.2 /
97.4 - 93.2
98.0 - 98.1 - 96.2 /
98.0 - 98.1
Note:
The data are based on the conditions shown in the table below.
Cooling Heating Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB / 6°CWB
7.5 m
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
4 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Specifications
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Model
Capacity Rated (Min. ~ Max.)
Running Current (Rated) A 5.3 - 5.1 - 4.8 / 5.3 - 5.1 6.5 - 6.2 - 6.0 / 6.5 - 6.2 Power Consumption Rated
(Min. ~ Max.) Power Factor (Rated) % 98.6 - 98.0 - 99.8 / 98.6 - 98.0 98.6 - 98.9 - 97.9 / 98.6 - 98.9 COP Rated (Min. ~ Max.) W/W 4.30 (5.45 ~ 3.63) 4.47 (6.00 ~ 3.56)
Piping Connections
Heat Insulation Both Liquid and Gas Pipes Max. Interunit Piping Length m 30 Max. Interunit Height Difference m 12 Chargeless m Amount of Additional Charge of
Refrigerant
Indoor Unit FTXZ50NVMM
Front Panel Colour Whit e
Airflow Rate
Fan
Air Direction Control Right, Left, Horizontal, Downwards Air Filter Auto cleaning filter Running Current (Rated) A 0.14 - 0.14 - 0.13 / 0.14 - 0.14 0.14 - 0.14 - 0.13 / 0.14 - 0.14 Power Consumption (Rated) W 30 - 30 - 30 / 30 - 30 30 - 30 - 30 / 30 - 30 Power Factor (Rated) % 97.4 - 93.2 - 96.2 / 97.4 - 93.2 97.4 - 93.2 - 96.2 / 97.4 - 93.2 Temperature Control Microcomputer Control Dimensions (H × W × D) mm 295 × 798 × 370 Packaged Dimensions (H × W × D) mm 434 × 865 × 361 Weight (Mass) kg 15 Gross Weight (Gross Mass) kg 19 Sound Pressure
Level Sound Power Level (H) dB 60 59
Outdoor Unit RXZ50NVM
Casing Colour Ivory White
Compressor
Refrigerant Oil
Refrigerant
Airflow Rate
Fan
Running Current (Rated) A 5.2 - 5.0 - 4.7 / 5.2 - 5.0 6.4 - 6.1 - 5.9 / 6.4 - 6.1 Power Consumption (Rated) W 1,120 1,380 Power Factor (Rated) % 97.9 - 97.4 - 99.3 / 97.9 - 97.4 98.0 - 98.4 - 97.5 / 98.0 - 98.4 Starting Current A 6.5 Dimensions (H × W × D) mm 595 × 795 × 300 Packaged Dimensions (H × W × D) mm 633 × 920 × 392 Weight (Mass) kg 43 Gross Weight (Gross Mass) kg 48 Sound Pressure Level (H) dB(A) 49 50 Sound Power Level (H) dB 63 64 Drawing No. 3D086956
Indoor Unit FTXZ50NVMM
Outdoor Unit
kW 4.95 (0.6 ~ 5.8) 6.3 (0.6 ~ 9.4)
Btu/h 16,900 (2,000 ~ 19,800) 21,500 (2,000 ~ 32,100)
kcal/h 4,260 (520 ~ 4,990) 5,420 (520 ~ 8,080)
W 1,150 (110 ~ 1,600) 1,410 (100 ~ 2,640)
Liquid mm Gas mm
Cooling Heating
RXZ50NVM
6.4
φ
9.5
φ
g/m
H M 9.2 (326) 10.7 (378) L 6.6 (232) 7.7 (274) SL 4.6 (164) 5.9 (210) Type Cross Flow Fan Motor Output W 30 Speed Steps 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 47 / 38 / 30 / 23 44 / 38 / 31 / 24
Type Hermetically Sealed Swing Type Model 2YC40DXD Type FW68DA Charge L 0.405 Type R-32 Charge kg 1.34 H L 22.5 (764) 16.2 (571) Type PZ440 Motor Output W 71
m³/min
(cfm)
m³/min
(cfm)
15.0 (545) 14.4 (517)
40.4 (1,427) 33.1 (1,170)
Note:
The data are based on the conditions shown in the table below.
Cooling Heating Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB / 6°CWB
7.5 m
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Split Type Air Conditioners FTXZ-N Series 5
Dimensions EDMY041425

4. Dimensions

4.1 Indoor Unit

FTXZ25/35/50NVMM
LEFT GRILLE FIXED SCREWS (INSIDE PANEL)
AUXILIARY FLAP (HORIZONTAL BLADE)
FLAP (HORIZONTAL BLADE)
INTELLIGENT EYE SENSOR
TRANSMITTER / RECEIVER
56
WIRELESS REMOTE
CONTROLLER
(ARC477A2)
OPERATION LAMP
TIMER LAMP
30
227
798
CIRCULATION FLOW
AIR CLEANING UPPER LIMIT (SINGULARITY OPERATION) COOLING UPPER LIMIT DEHUMIDIFICATION UPPER LIMIT DEHUMIDIFICATION COOLING UPPER LIMIT HEATING UPPER LIMIT
THE MARK () SHOWS PIPING DIRECTION
QUICK HEATING TIMER LAMP
MODEL NAME PLATE
13˚
COOLING LOWER LIMIT DEHUMIDIFICATION LOWER LIMIT DEHUMIDIFICATION COOLING LOWER LIMIT
MOLD PROOF CLEANING FILTER LAMP TRANSMITTER / RECEIVER
OPERATION ON/OFF SWITCH (INSIDE PANEL)
RIGHT GRILLE FIXED SCREWS (INSIDE PANEL)
TERMINAL BLOCK WITH EARTH TERMINAL (AFTER REMOVING THE SERVICE COVER)
BLADE ANGLE
AUXILIARY FLAP
55˚
65˚
AIR CLEANING LOWER LIMIT (SINGULARITY OPERATION) HEATING LOWER LIMIT
372
370
295
86
150
179
328
CIRCULATION FLOW
13˚ 17˚
AIR CLEANING UPPER LIMIT (SINGULARITY OPERATION) COOLING UPPER LIMIT DEHUMIDIFICATION UPPER LIMIT DEHUMIDIFICATION COOLING UPPER LIMIT
HEATING UPPER LIMIT
28˚
COOLING LOWER LIMIT DEHUMIDIFICATION LOWER LIMIT DEHUMIDIFICATION COOLING LOWER LIMIT
()
MAIN FLAP
55˚
65˚
DISTANCE FROM WALL MIN.50 FOR OPERATION (RECOMMENDED) MIN.20 FOR INSTALLATION
NAME PLATE
SECURE THE CLEARANCE 15mm FROM INDOOR UNIT WHEN (∗) IS OVER 70mm BY CURTAIN RAIL
15
SHUTTER (BOTTOM AIR INLET)
AIR CLEANING LOWER LIMIT (SINGULARITY OPERATION) HEATING LOWER LIMIT
44.5
AIR FLOW (INDOOR)REQUIRED SPACE
APPROX. 350
GAS PIPE 9.5CuT
APPROX. 400
LIQUID PIPE 6.4CuT
APPROX. 430
14.5
48
WALL HOLE FOR EMBEDDED PIPING φ65 HOLE
STANDARD LOCATIONS OF WALL HOLES
DRAIN HOSE CONNECTING PART
LIQUID PIPE
GAS PIPE
798
MIN.30
(SPACE FOR PERFORMANCE) DISTANCE FROM WALL
MIN.50 FOR OPERATION (RECOMMENDED) MIN.20 FOR INSTA
APPROX. 330
APPROX. 380 APPROX. 400
φ16
DRAIN HOSE
72645
48
φ18
170.4
44.5
LL
295
ATION
3D086877

4.2 Outdoor Unit

RXZ25/35/50NVM
18
OUTDOOR AIR THERMISTOR
20
MINIMUM SPACE FOR AIR PASSAGE
100
50 50
27.5
DRAIN OUTLET (I.D. φ15.9 HOSE FOR CONNECTION)
2017 300
HANDLE
595
WALL HEIGHT ON AIR OUTLET SIDE
150
= LESS THAN 1200
50
495
795 6315
BRAND NAME LABEL
MANUFACTURER'S LABEL
150
300
90.5574
4-HOLES FOR ANCHOR BOLTS (M8 OR M10)
328.5
326
(BASE PITCH)
342
50
100
LIQUID STOP VALVE (φ6.4 CuT)
GAS STOP VALVE (φ9.5 CuT)
SERVICE PORT
13
TERMINAL STRIP WITH EARTH TERMINAL
156
IN CASE OF REMOVING STOP VALVE COVER
50
200
165
105
3D086876
6 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Wiring Diagrams

5. Wiring Diagrams

5.1 Indoor Unit

FTXZ25/35/50NVMM
CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS
FIELD WIRING.
indoor
FG1
GRN/YLW
GRN/YLW
GRN
E1
C105
C104
outdoor
X1M
+ _
TRANSMISSION
_
CIRCUIT
_
+
IPM200
13478
S200
BLK
RED
WHT
MS
3~
M1F
M1S M4S M5SM3SM2S
MSW MSW MSWMSWMSW
213
WHT
ORG
231
RED
BLK
WHT
(H250V,T3.15A)
R1V
F1U
U
MR10
S32
1
2
BLK
BLK
R1T
WIRELESS
REMOTE
CONTROLLER
BLU
PNK
BLK
YLW
H1 H3
H2
A2P
S1W
TRANSMITTER
RECEIVER
BLU
ORG
PNK
YLW
A4P
R2T
HUMIDITY SENSOR
1
4
BLK
BLK
BLK
4
1
BLK
BLK
BLK
1
SIGNAL
SIGNAL
BLK
BLK
RED
BLK
15
ORG
S1C
S46
BLK
S56
YLW
BLK
1
BLK
BLK
136˚C
PNK
BLU
M6S M8SM7S
BLU
BLU
PNK
ORG
YLW
5
5
A1P
15
BLK
BLK
BLK
BLK
BLK
15
F1UT
S26
LED5 LED1LED2 LED4
H5PH1PH2P H4P
ORG
PNK
BLU
RED
YLW
MSWMSW MSW
RED
BLU
PNK
BLU
PNK
ORG
RED
YLW
5
2041130
BLK
BLK
6
1
AREA B(L)
BLK
BLK
BLK
INTELLIGENT EYE SENSOR
AREA A(R
BLK BLK BLK
INTELLIGENT EYE SENSOR
TURNED OFF AND THEN BACK ON AGAIN.
A1P~A4P A6P, A7P C104, C105 FG1 F1U F1UT
BLK
ORG
BLU
PNK
YLW
H1P, H2P H4P, H5P S1C S2C M1F M1S~M8S MR10 R1T, R2T R1V
29
S16~S401 CN403, B401
RED
ORG
YLW
S1W X1M
S41S44S33
1
BLK
1
A6P
3
1
S401
HIGH VOLTAGE
)
UNIT
1
A7P
A3P
3
: PRINTED CIRCUIT BOARD : CAPACITOR : FLAME GROUND : FUSE : THERMAL FUSE
: PILOT LAMP : LIMIT SWITCH FOR BRUSH : LIMIT SWITCH FOR STREAMER : FAN MOTOR : SWING MOTOR : MAGNETIC RELAY : THERMISTOR : VARISTOR
: CONNECTOR : OPERATION SWITCH : TERMINAL STRIP : PROTECTIVE EARTH
S52
5
BLK
BLK
BLK
BLK
5
CN403
6
B401
1
S16
4 1
S21
5
HA
S53
1
BLK
BLK
S2C
WHT WHT
STREAMER PA RT
3D086394

5.2 Outdoor Unit

RXZ25/35/50NVM
INDOOR
1 2 3
L N
NOTE
1. REFER TO THE NAME PLATE FOR THE POWER REQUIREMENTS.
.DB1, DB3 .FU1, FU2, FU3 .HK1, HK2, HK3 .IPM1, IPM2 .L .L1R, L2R .MRK, MR4, MR30 .MRM10, MRM20 .M1C .M1F
: DIODE BRIDGE : FUSE : CONNECTOR : INTELLIGENT POWER MODULE : LIVE : REACTOR : MAGNETIC RELAY : MAGNETIC RELAY : COMPRESSOR MOTOR : FAN MOTOR
FIELD WIRING
102˚C
1L 2N 3
X1M
YLW YLW
BLK WHT RED GRN/
YEL
Z2C N=3
GRN
OUTDOOR
Z1C N=6
GRY
.N .PCB1 .Q1M .R1T, R2T, R3T .R5T .SA1 .V3, V5 .X5A, X6A .X1M .Y1E
1 3
HL1 HN1 S
E1
E2
S45
FU3 30A
HK3 HK2 HK1
1
4 1
2
V5
U
S101
V3
U
SA1
MR30
MRK
MRM20
MRM10
FU1
3.15A
S213
7
1
S22
BLK
BLK
ORG
BLU
WHT
5
1 2
S501
YLW
M
Y1E
R5T
(OUTDOOR)
: NEUTRAL : PRINTED CIRCUIT BOARD : OVERLOAD PROTECTOR : THERMISTOR : LIQUID PIPE THERMISTOR : SURGE ARRESTER : VARISTOR : CONNECTOR : TERMINAL STRIP : ELECTRONIC EXPANSION VALVE COIL
DB1
+
BLK
RED
BLK
BLK
R3TR2TR1T (DISCHARGE)
(CONDENSER)
L2RL1R
RED
BRN
WHT
+
HR2HR1
PCB1
IPM2DB3
MR4
S80
4411763 1
3121612582
YLW
YLW
Y1S
.Y1S .Z1C, Z2C, Z3C, Z4C
.
S70
Z4C N=3
PPL
+
IPM1
+
HR4HR3
FU2
3.15A +
S40S72S20 S90S91
U
BRN
RED
BLU
WHT
ORG
BLK
BLK
X6A
BLK
BLK
MS
UW
M1CQ1MM1F
: REVERSING SOLENOID VALVE COIL : FERRITE CORE : PROTECTIVE EARTH
RED
RED
MS 3
~
VW
YLW
YLW
V
BLU
Z3C N=3
BLU
X5A
3D086397B
Split Type Air Conditioners FTXZ-N Series 7
Piping Diagrams EDMY041425

6. Piping Diagrams

6.1 Indoor Unit

FTXZ25/35/50NVMM
INDOOR UNIT
HEAT EXCHANGER
HEAT EXCH.
THERMISTOR
(DC)
ROOM TEMPERATURE SENSOR HUMIDITY SENSOR (INDOOR)
FIELD PIPING
(6.4CuT)
FIELD PIPING
(9.5CuT)
CROSS FLOW FAN
6.4CuT
M
FAN MOTOR
SINGLE UNION JOINT
9.5CuT
SINGLE UNION JOINT
REFRIGERANT FLOW
COOLING
HEATING

6.2 Outdoor Unit

RXZ25/35/50NVM
7.9CuT
7.9CuT
12.7CuT
HEAT EXCH.
THERMISTOR
(DE)
12.7CuT
MUFFLER
OUTDOOR UNIT
HEAT EXCHANGER
AUXILIARY
HEAT EXCHANGER
PROPELLER FAN
FAN MOTOR
M
FOUR WAY VALVE ON : HEATING
7.9CuT
DISCHARGE PIPE THERMISTOR (DO)
7.9CuT COMPRESSOR
DISTRIBUTOR
7.9CuT
7.9CuT
4.0CuT
4.0CuT
12.7CuT
ACCUMULATOR
9.5CuT
MUFFLER
WITH FILTER
12.7CuT
12.7CuT
OUTDOOR TEMPERATURE
THERMISTOR
MOTOR OPERATED
6.4CuT
MUFFLER
REFRIGERANT FLOW
COOLING
HEATING
VALV E
LIQUID RECEIVER
9.5CuT
6.4CuT
STRAINERSTRAINER
MUFFLER
WITH FILTER
4D086882
LIQUID PIPE THERMISTOR (DL)
6.4CuT
6.4CuT
LIQUID STOP
VALV E
GAS STOP
VALV E
FIELD PIPING
(6.4CuT)
FIELD PIPING
(9.5CuT)
3D086885
8 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Capacity Tables

7. Capacity Tables

FTXZ25NVMM + RXZ25NVM (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
Cooling
AFR 10.7
BF 0.10
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB –10 –5 0 5 10 15
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 3.19 2.54 0.17 3.08 2.49 0.17 2.97 2.44 0.20 2.85 2.38 0.23 2.74 2.33 0.27 2.62 2.28 0.30
16.0 22 3.31 2.49 0.20 3.19 2.44 0.20 3.08 2.39 0.20 2.97 2.34 0.24 2.85 2.29 0.27 2.74 2.24 0.30
18.0 25 3.42 2.62 0.21 3.31 2.57 0.21 3.19 2.53 0.21 3.08 2.48 0.24 2.96 2.43 0.27 2.85 2.39 0.30
19.0 27 3.48 2.78 0.21 3.36 2.74 0.21 3.25 2.69 0.21 3.13 2.65 0.24 3.02 2.60 0.27 2.91 2.56 0.30
22.0 30 3.65 2.68 0.24 3.53 2.64 0.24 3.42 2.60 0.24 3.30 2.56 0.24 3.19 2.52 0.27 3.08 2.48 0.31
24.0 32 3.76 2.61 0.24 3.64 2.57 0.24 3.53 2.54 0.24 3.42 2.50 0.24 3.30 2.47 0.28 3.19 2.43 0.31
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20 25 30 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 2.51 2.22 0.33 2.40 2.17 0.36 2.28 2.12 0.39 2.17 2.07 0.43 2.05 2.02 0.43
16.0 22 2.62 2.19 0.33 2.51 2.14 0.36 2.39 2.09 0.40 2.28 2.04 0.43 2.17 2.00 0.43
18.0 25 2.74 2.34 0.33 2.62 2.30 0.37 2.51 2.25 0.40 2.39 2.21 0.43 2.28 2.16 0.43
19.0 27 2.79 2.52 0.33 2.68 2.47 0.37 2.56 2.43 0.40
22.0 30 2.96 2.44 0.34 2.85 2.41 0.37 2.73 2.37 0.40 2.62 2.33 0.43 2.51 2.29 0.44
24.0 32 3.07 2.40 0.34 2.96 2.36 0.37 2.85 2.33 0.40 2.73 2.29 0.43 2.62 2.26 0.44
2.45 2.39 0.43 2.34 2.34 0.43
Heating
AFR 11.7
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15 –10 –5 0 6 10
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 1.710.402.060.422.410.443.240.583.720.614.050.63
20.0 1.610.411.950.432.300.453.110.59
22.0 1.570.411.910.442.260.463.060.593.550.633.880.65
24.0 1.520.421.870.442.220.463.010.603.500.633.830.65
25.0 1.500.421.850.442.190.462.990.603.480.633.800.65
27.0 1.460.431.810.452.150.472.940.613.430.643.750.66
Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
BF : Bypass factor
EWB : Entering wet bulb temp. (°C)
EDB : Entering dry bulb temp. (°C)
TC : Total capacity (kW)
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the
4. About SHC which are not mentioned in the table, please calculate them with
5. Capacities are based on the following conditions.
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated in the above table.
3.60 0.62 3.93 0.64
motor heat.
above tables. (Figures out of the tables should not be used for calculation.)
around values in direct proportion.
Corresponding refrigerant piping length : 7.5 m Level difference : 0 m
3D087021A
Split Type Air Conditioners FTXZ-N Series 9
Capacity Tables EDMY041425
FTXZ35NVMM + RXZ35NVM (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
Cooling
AFR 12.1
BF 0.14
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB –10 –5 0 5 10 15
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 4.50 3.27 0.27 4.34 3.19 0.27 4.18 3.11 0.32 4.02 3.03 0.37 3.86 2.95 0.42 3.70 2.87 0.45
16.0 22 4.66 3.19 0.27 4.50 3.11 0.27 4.34 3.04 0.32 4.18 2.96 0.37 4.01 2.89 0.42 3.85 2.81 0.47
18.0 25 4.82 3.31 0.33 4.66 3.24 0.33 4.50 3.17 0.33 4.33 3.10 0.38 4.17 3.03 0.43 4.01 2.96 0.48
19.0 27 4.90 3.48 0.33 4.74 3.41 0.33 4.57 3.34 0.33 4.41 3.28 0.38 4.25 3.21 0.43 4.09 3.14 0.48
22.0 30 5.13 3.33 0.38 4.97 3.27 0.38 4.81 3.21 0.38 4.65 3.15 0.38 4.49 3.09 0.43 4.33 3.03 0.48
24.0 32 5.29 3.23 0.39 5.13 3.17 0.39 4.97 3.12 0.39 4.81 3.06 0.39 4.65 3.01 0.44 4.49 2.96 0.49
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20 25 30 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 3.53 2.79 0.52 3.37 2.71 0.57 3.21 2.64 0.62 3.05 2.56 0.67 2.89 2.49 0.68
16.0 22 3.69 2.74 0.52 3.53 2.67 0.57 3.37 2.60 0.63 3.21 2.53 0.68 3.05 2.46 0.68
18.0 25 3.85 2.90 0.53 3.69 2.83 0.58 3.53 2.76 0.63 3.37 2.70 0.68 3.21 2.63 0.69
19.0 27 3.93 3.08 0.53 3.77 3.01 0.58 3.61 2.95 0.63
22.0 30 4.17 2.98 0.53 4.01 2.92 0.58 3.85 2.86 0.63 3.69 2.81 0.68 3.53 2.75 0.69
24.0 32 4.33 2.91 0.54 4.17 2.85 0.59 4.01 2.80 0.64 3.85 2.75 0.69 3.69 2.70 0.69
3.45 2.89 0.68 3.29 2.82 0.69
Heating
AFR 13.3
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15 –10 –5 0 6 10
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 2.380.642.860.683.340.714.500.935.170.985.621.01
20.0 2.230.662.710.693.190.734.320.95
22.0 2.180.672.660.703.140.734.250.964.931.015.381.04
24.0 2.120.682.600.713.080.744.180.974.861.025.311.05
25.0 2.090.682.570.713.050.754.150.974.831.025.281.05
27.0 2.030.692.510.722.990.754.080.984.761.034.830.96
Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
BF : Bypass factor
EWB : Entering wet bulb temp. (°C)
EDB : Entering dry bulb temp. (°C)
TC : Total capacity (kW)
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the
4. About SHC which are not mentioned in the table, please calculate them with
5. Capacities are based on the following conditions.
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated in the above table.
5.00 1.00 5.45 1.03
motor heat.
above tables. (Figures out of the tables should not be used for calculation.)
around values in direct proportion.
Corresponding refrigerant piping length : 7.5 m Level difference : 0 m
3D087022A
10 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Capacity Tables
FTXZ50NVMM + RXZ50NVM (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
Cooling
AFR 15.0
BF 0.17
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB –10 –5 0 5 10 15
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 5.59 4.02 0.45 5.59 4.02 0.45 5.59 4.02 0.45 5.59 4.02 0.45 5.53 3.99 0.45 5.30 3.87 0.45
16.0 22 6.68 4.37 0.46 6.45 4.25 0.46 6.22 4.14 0.55 5.99 4.02 0.58 5.76 3.91 0.58 5.53 3.80 0.58
18.0 25 6.91 4.50 0.47 6.68 4.39 0.47 6.45 4.28 0.55 6.22 4.17 0.64 5.99 4.07 0.72 5.76 3.96 0.73
19.0 27 7.02 4.68 0.55 6.79 4.58 0.55 6.56 4.47 0.55 6.33 4.37 0.64 6.10 4.27 0.72 5.87 4.17 0.81
22.0 30 7.37 4.47 0.56 7.14 4.37 0.56 6.91 4.28 0.56 6.68 4.19 0.65 6.44 4.10 0.73 6.21 4.01 0.82
24.0 32 7.59 4.31 0.65 7.36 4.23 0.65 7.13 4.15 0.65 6.90 4.06 0.65 6.67 3.98 0.74 6.44 3.90 0.82
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20 25 30 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 5.07 3.75 0.88 4.84 3.64 0.97 4.61 3.52 1.05 4.38 3.41 1.14 4.15 3.30 1.15
16.0 22 5.30 3.69 0.89 5.07 3.58 0.97 4.84 3.47 1.06 4.61 3.37 1.14 4.38 3.26 1.15
18.0 25 5.53 3.86 0.89 5.30 3.76 0.98 5.07 3.66 1.06 4.84 3.56 1.15 4.61 3.46 1.16
19.0 27 5.64 4.07 0.89 5.41 3.97 0.98 5.18 3.88 1.06
22.0 30 5.98 3.92 0.90 5.75 3.84 0.99 5.52 3.75 1.07 5.29 3.67 1.16 5.06 3.59 1.17
24.0 32 6.21 3.82 0.91 5.98 3.74 0.99 5.75 3.66 1.08 5.52 3.59 1.16 5.29 3.51 1.17
4.95 3.78 1.15 4.72 3.69 1.16
Heating
AFR 14.4
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15 –10 –5 0 6 10
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 3.000.913.600.954.211.005.661.316.521.387.091.42
20.0 2.820.933.420.984.021.035.451.34
22.0 2.740.943.350.993.951.045.361.356.211.426.361.34
24.0 2.670.953.271.003.881.055.271.375.881.365.881.24
25.0 2.630.963.241.003.841.055.231.375.641.305.641.18
27.0 2.560.973.161.013.771.065.141.385.161.185.161.08
Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
BF : Bypass factor
EWB : Entering wet bulb temp. (°C)
EDB : Entering dry bulb temp. (°C)
TC : Total capacity (kW)
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the
4. About SHC which are not mentioned in the table, please calculate them with
5. Capacities are based on the following conditions.
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated in the above table.
6.30 1.41 6.84 1.45
motor heat.
above tables. (Figures out of the tables should not be used for calculation.)
around values in direct proportion.
Corresponding refrigerant piping length : 7.5 m Level difference : 0 m
3D087023A
Split Type Air Conditioners FTXZ-N Series 11
Operation Limit EDMY041425

8. Operation Limit

RXZ25/35/50NVM
43 40
30
20
10
Outdoor temp. (˚CDB)
0
-10
Cooling
Continuous operation
Indoor temp. (˚CWB)
Pull-down period
2815 20 302310
Notes:
The graphs are based on the following conditions.
• Equivalent piping length
• Level difference
• Air flow rate
20 18
15
10
Outdoor temp. (˚CWB)
-10
-15
-20
(-20˚CDB)
7.5m 0m
High
Heating
5
0
-5
Continuous operation
10 20 30
Indoor temp. (˚CDB)
3D087020
12 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Sound Level

9. Sound Level

9.1 Measuring Location

Indoor Unit Outdoor Unit
1 m
0.8 m
MICROPHONE
1 m
Notes: 1. Operation sound is measured in an anechoic chamber.
2. The data are based on the conditions shown in the table below.
Indoor ; 27°CDB / 19°CWB
Cooling Heating Piping Length
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB / 6°CWB
MICROPHONE
5 m
Split Type Air Conditioners FTXZ-N Series 13
Sound Level EDMY041425

9.2 Indoor Unit

FTXZ25NVMM
COOLING HEATING
70
60
)
50
bar
µ
40
0dB=0.0002 (
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63 125
250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
)
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OVER ALL (dB
220-240/220-230V
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
POWER SOURCE
JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
)
50/60Hz
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
50/60Hz
220-240/220-230V
(H)
220-240/220-230V 50/60Hz
Cooling
(L)
2638
)
FTXZ35NVMM
COOLING HEATING
70
60
)
50
bar
µ
40
0dB=0.0002 (
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63 125
250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
)
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OVER ALL (dB
SCALE
220-240/220-230V
A
(
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
POWER SOURCE
JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
)
50/60Hz
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
50/60Hz
220-240/220-230V
(H)
220-240/220-230V 50/60Hz
Cooling
(L)
2742
)
70
60
)
50
bar
µ
40
0dB=0.0002
(
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
70
60
)
50
bar
µ
40
0dB=0.0002
(
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
)
)
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OVER ALL (dB
50/60Hz
220-240/220-230V
SCALE
POWER SOURCE
SCALE
POWER SOURCE
(H)
A
(
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
220-240/220-230V 50/60Hz
JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
Heating
OVER ALL (dB
50/60Hz
220-240/220-230V
(H)
A
(
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
220-240/220-230V 50/60Hz
JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
Heating
)
50/60Hz
220-240/220-230V
(L)
2839
)
3D086964
)
50/60Hz
220-240/220-230V
(L)
2942
)
3D086965
FTXZ50NVMM
COOLING HEATING
70
60
)
50
bar
µ
40
0dB=0.0002 (
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63 125
250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
)
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OVER ALL (dB
SCALE
220-240/220-230V
A
(
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
POWER SOURCE
JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE
)
50/60Hz
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
50/60Hz
220-240/220-230V
(H)
220-240/220-230V 50/60Hz
Cooling
(L) 3047
)
70
60
)
50
bar
µ
40
0dB=0.0002
(
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
)
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OVER ALL (dB
50/60Hz
SCALE
220-240/220-230V
(H)
A
(
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
POWER SOURCE
STANDARD EXTERNAL STATIC PRESSURE
220-240/220-230V 50/60Hz
JIS STANDARD
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
Heating
)
50/60Hz
220-240/220-230V
(L)
3144
)
3D086966
14 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Sound Level

9.3 Outdoor Unit

RXZ25NVM
COOLING HEATING
70
60
)
50
bar
µ
40
0dB=0.0002 (
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63 125
250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
)
NC-70
SCALE
NC-60
A
(
B.G.N IS ALREADY RECTIFIED
NC-50
NC-40
NC-30
NC-20
OPERATING CONDITIONS
POWER SOURCE
OVER ALL (dB
JIS STANDARD
)
50/60Hz
220-240/220-230V
46
)
220-240/220-230V 50/60Hz
Cooling
RXZ35NVM
COOLING HEATING
70
60
)
50
bar
µ
40
0dB=0.0002 (
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63 125
250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
)
NC-70
SCALE
NC-60
A
(
B.G.N IS ALREADY RECTIFIED
NC-50
NC-40
NC-30
NC-20
OPERATING CONDITIONS
POWER SOURCE
OVER ALL (dB
JIS STANDARD
)
50/60Hz
220-240/220-230V
48
)
220-240/220-230V 50/60Hz
Cooling
70
60
)
50
bar
µ
40
0dB=0.0002
(
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
70
60
)
50
bar
µ
40
0dB=0.0002
(
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
)
)
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OVER ALL (dB
SCALE
POWER SOURCE
SCALE
POWER SOURCE
220-240/220-230V
A46
(
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
220-240/220-230V 50/60Hz
JIS STANDARD
Heating
OVER ALL (dB
220-240/220-230V
A48
(
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
220-240/220-230V 50/60Hz
JIS STANDARD
Heating
)
50/60Hz
)
3D086967
)
50/60Hz
)
3D086968
RXZ50NVM
COOLING HEATING
70
60
)
50
bar
µ
40
0dB=0.0002 (
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63 125
250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
)
OVER ALL (dB
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
POWER SOURCE
JIS STANDARD
)
50/60Hz
220-240/220-230V
49
) (
220-240/220-230V 50/60Hz
Cooling
70
60
)
50
bar
µ
40
0dB=0.0002
(
30
dB
20
APPROXIMATE
OCTAVE BAND SOUND PRESSURE LEVEL
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz
)
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OVER ALL (dB
SCALE
POWER SOURCE
220-240/220-230V
A50
B.G.N IS ALREADY RECTIFIED
OPERATING CONDITIONS
220-240/220-230V 50/60Hz
JIS STANDARD
Heating
)
50/60Hz
)
3D086969
Split Type Air Conditioners FTXZ-N Series 15
Electric Characteristics EDMY041425

10.Electric Characteristics

Indoor Unit Outdoor Unit
FTXZ25NVMM RXZ25NVM
FTXZ35NVMM RXZ35NVM
FTXZ50NVMM RXZ50NVM
Symbols:
MCA : Min. circuit amps (A)
MFA : Max. fuse amps (A)
Notes:
1. Maximum allowable voltage variation between phases is 2%.
2. Select wire size based on the larger value of MCA.
3. Instead of fuse, use circuit breaker.
4. Be sure to install an earth leak detector. (This unit uses an inverter, which means that an earth leak detector capable of handling high harmonics must be used in order to prevent malfunctioning of the earth leak detector.)
Hz - Volts Voltage Range MCA MFA
50 - 220 50 - 230 50 - 240 60 - 220 60 - 230 50 - 220 50 - 230 50 - 240 60 - 220 60 - 230 50 - 220 50 - 230 50 - 240 60 - 220 60 - 230
Power Supply
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
10.5 16
13.25 16
15 16
3D087024
16 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Installation Manual

11.Installation Manual

Split Type Air Conditioners FTXZ-N Series 17
Installation Manual EDMY041425
18 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Installation Manual
Split Type Air Conditioners FTXZ-N Series 19
Installation Manual EDMY041425
20 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Installation Manual
Split Type Air Conditioners FTXZ-N Series 21
Installation Manual EDMY041425
22 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Installation Manual
Split Type Air Conditioners FTXZ-N Series 23
Installation Manual EDMY041425
24 Split Type Air Conditioners FTXZ-N Series
EDMY041425 Installation Manual
Split Type Air Conditioners FTXZ-N Series 25
Installation Manual EDMY041425
26 Split Type Air Conditioners FTXZ-N Series
Loading...
+ 64 hidden pages