Daikin RKMBUHCA3V3, RKMBUHCA9W1 Installation manuals

Installation manual
ROTEX HPSU low temperature monobloc backup
heater
RKMBUHCA3V3 RKMBUHCA9W1
Installation manual
ROTEX HPSU low temperature monobloc backup heater
English
Table of Contents

1 About the documentation 2

1.1 About this document.................................................................. 2

2 About the box 2

2.1 Backup heater ........................................................................... 2
2.1.1 To remove the accessories from the backup heater... 2

3 Preparation 2

3.1 Preparing installation site .......................................................... 2
3.1.1 Installation site requirements of the backup heater .... 2
3.2 Preparing water piping .............................................................. 3
3.3 Preparing electrical wiring ......................................................... 3
3.3.1 Overview of electrical connections for external and
internal actuators ........................................................ 3
4 Installation 3
4.1 Opening the units ...................................................................... 3
4.1.1 To open the backup heater......................................... 3
4.1.2 To open the switch box cover of the backup heater ... 3
4.2 Mounting the backup heater...................................................... 3
4.2.1 To install the backup heater........................................ 3
4.3 Connecting the water piping...................................................... 4
4.3.1 To connect the water piping to the backup heater...... 4
4.4 Connecting the electrical wiring................................................. 5
4.4.1 To connect the electrical wiring on the backup heater 5
4.4.2 To connect the backup heater power supply .............. 5
4.4.3 To connect the backup heater kit to the control box ... 6
5 Starting up the system 6
1 About the documentation
Installer reference guide:
▪ Preparation of the installation, technical specifications, good
practices, reference data,…
▪ Format: Digital files on the ROTEX homepage
Addendum book for optional equipment:
▪ Additional info about how to install optional equipment
▪ Format: Paper (in the box of the outdoor unit) + Digital files on
the ROTEX homepage
Latest revisions of the supplied documentation may be available on the regional ROTEX website or via your dealer.
The original documentation is written in English. All other languages are translations.
2 About the box

2.1 Backup heater

NOTICE
▪ The backup heater is an option and can only be used in
combination with outdoor units RDLQ05+07CAV3 and RBLQ05+07CAV3.
▪ To be able to use the backup heater, it is required that
optional control box RKCB07CAV3 is part of the system.

2.1.1 To remove the accessories from the backup heater

1 Remove the wall bracket from the box.

1.1 About this document

Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set consists of:
General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: Paper (in the box of the outdoor unit)
Outdoor unit installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the outdoor unit)
Control box installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the control box)
Option box installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the option box)
Backup heater installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the backup heater)
3 Preparation

3.1 Preparing installation site

3.1.1 Installation site requirements of the backup heater

▪ Mind the measurement guidelines:
Maximum distance between the backup heater and the outdoor unit
▪ Mind the following spacing installation guidelines:
10m
Installation manual
2
ROTEX HPSU low temperature monobloc backup heater
RKMBUHCA3V3 + RKMBUHCA9W1
4P414875-1 – 2015.08
>50 >50
>200
>500
>350
INFORMATION
2
1
1
2
If the backup heater is installed in a reversible system (RBLQ05+07CAV3) and valve kit EKMBHBP1 is part of the system, it may be required to provide more space under the backup heater than indicated above. For more information, refer to the installer reference guide and to the documentation of the valve kit.
▪ The backup heater is designed to be wall-mounted in indoor
locations only. Make sure the installation surface is a flat and vertical non-combustible wall.
▪ The backup heater is designed to operate in ambient
temperatures ranging from 5~30°C.

4 Installation

4 Installation

4.1 Opening the units

4.1.1 To open the backup heater

3.2 Preparing water piping

When installing the backup heater in the system, make sure the required minimum water flow rate is guaranteed at all times. For more information, refer to the installation manual of the outdoor unit.

3.3 Preparing electrical wiring

3.3.1 Overview of electrical connections for external and internal actuators

Item Description Wires Maximum
Interconnection cable
1 Backup heater kit
2 Backup heater kit
3 Backup heater kit
Backup heater Power supply Required number of
RKMBUHCA3V3 1× 230V 2+GND
RKMBUHCA9W1 1× 230V 2+GND+2 bridges
thermistor
thermal protector
connection (from control box)
(a) Minimum cable section: 0.75mm2; maximum length: 10m.
3× 400V 4+GND
2
2
2 (3V3)
3 (6V3, 6W1, 9W1)
conductors
running
current
(a)
(a)
(a)

4.1.2 To open the switch box cover of the backup heater

4.2 Mounting the backup heater

4.2.1 To install the backup heater

1 Fix the wall bracket to the wall with M5 screws.
NOTICE
More technical specifications of the different connections are indicated on the inside of the backup heater.
RKMBUHCA3V3 + RKMBUHCA9W1 ROTEX HPSU low temperature monobloc backup heater 4P414875-1 – 2015.08
Installation manual
3
Loading...
+ 5 hidden pages