Daikin REYQ8U7Y1B, REYQ10U7Y1B, REYQ12U7Y1B, REYQ14U7Y1B, REYQ16U7Y1B Operation manuals [fr]

...
Manuel d'installation et
d'utilisation
Récupération de chaleur VRV IV+
REYQ8U7Y1B REYQ10U7Y1B REYQ12U7Y1B REYQ14U7Y1B REYQ16U7Y1B REYQ18U7Y1B REYQ20U7Y1B
Manuel d'installation et d'utilisation
Récupération de chaleur VRV IV+
Français
Directivelor, cu amendamentele respective.
<A>
<B>
<C>
TÜV (NB0197)
60128402
DAIKIN.TCF.030B4/12-2018
<D> Daikin.TCFP.001
<E> VINÇOTTE nv (NB0026)
<F> D1
<G> —II<H>
Direktive z vsemi spremembami.
Direktiivid koos muudatustega.
Директиви, с техните изменения.
Direktyvose su papildymais.
Direktīvās un to papildinājumos.
Smernice, v platnom znení.
18192021222324
съответстват на следните стандарти или други нормативни
документи, при условие, че се използват съгласно нашите
инструкции:
atitinka žemiau nurodytus standartus ir (arba) kitus norminius
dokumentus su sąlyga, kad yra naudojami pagal mūsų nurodymus:
tad, ja lietoti atbilstoši ražotāja norādījumiem, atbilst sekojošiem
standartiem un citiem normatīviem dokumentiem:
sú v zhode s nasledovnou(ými) normou(ami) alebo iným(i)
normatívnym(i) dokumentom(ami), za predpokladu, že sa používajú v
súlade snašim návodom:
ürünün, talimatlarımıza göre kullanılması koşuluyla aşağıdaki standartlar
21
222324
deklaruje na własną i wyłączną odpowiedzialność, że modele klimatyzatorów, których dotyczy niniejsza deklaracja:
declară pe proprie răspundere că aparatele de aer condiţionat la care se referă această declaraţie:
z vso odgovornostjo izjavlja, da so modeli klimatskih naprav, na katere se izjava nanaša:
kinnitab oma täielikul vastutusel, et käesoleva deklaratsiooni alla kuuluvad kliimaseadmete mudelid:
декларира на своя отговорност, че моделите климатична инсталация, за които се отнася тази декларация:
visiška savo atsakomybe skelbia, kad oro kondicionavimo prietaisų modeliai, kuriems yra taikoma ši deklaracija:
ar pilnu atbildību apliecina, ka tālāk uzskaitīto modeļu gaisa kondicionētāji, uz kuriem attiecas šī deklarācija:
vyhlasuje na vlastnú zodpovednosť, že tieto klimatizačné modely, na ktoré sa vzťahuje toto vyhlásenie:
tamamen kendi sorumluluǧunda olmak üzere bu bildirinin ilgili olduǧu klima modellerinin aşaǧıdaki gibi olduǧunu beyan eder:
17
18
19
20
21
22
23
24
25
spełniają wymogi następujących norm i innych dokumentów
normalizacyjnych, pod warunkiem że używane są zgodnie z naszymi
instrukcjami:
sunt în conformitate cu următorul (următoarele) standard(e) sau alt(e)
document(e) normativ(e), cu condiţia ca acestea să fie utilizate în
conformitate cu instrucţiunile noastre:
17
skladni z naslednjimi standardi in drugimi normativi, pod
18
19
ve norm belirten belgelerle uyumludur:
25
Direktiver, med senere ændringer.
Direktiv, med företagna ändringar.
Direktiver, med foretatte endringer.
10111213141516
Directives, as amended.
Direktiven, gemäß Änderung.
pogojem, da se uporabljajo v skladu z našimi navodili:
on vastavuses järgmis(t)e standardi(te)ga või teiste normatiivsete
dokumentidega, kui neid kasutatakse vastavalt meie juhenditele:
20
Directives, telles que modifiées.
010203040506070809
Değiştirilmiş halleriyle Yönetmelikler.
25
ako bolo uvedené v <A> a pozitívne zistené <B> vsúlade
sosvedčením<C>.
ako je to stanovené v Súbore technickej konštrukcie <D> a kladne
posúdené <E> (Aplikovaný modul <F>) podľa Certifikátu <G>. Kategória
nebezpečia <H>. Viď tiež nasledovnú stranu.
24*
Direktiivejä, sellaisina kuin ne ovat muutettuina.
v platném znění.
Smjernice, kako je izmijenjeno.
irányelv(ek) és módosításaik rendelkezéseit.
z późniejszymi poprawkami.
17
Richtlijnen, zoals geamendeerd.
Directivas, según lo enmendado.
Direttive, come da modifica.
Οδηγιών, όπως έχουν τροποποιηθεί.
Directivas, conforme alteração em.
Директив со всеми поправками.
kot je določeno v <A> in odobreno s strani <B> vskladu
19*
*
**
***
<A>’da belirtildiği gibi ve <C>Sertifikasına göre <B> tarafından olumlu
**
25*
scertifikatom<C>.
kot je določeno v tehnični mapi <D> in odobreno s strani <E> (Uporabljen
modul <F>) v skladu s certifikatom <G>. Kategorija tveganja <H>.
Glejtetudinanaslednji strani.
nagu on näidatud dokumendis <A> ja heaks kiidetud <B> järgi vastavalt
**
20*
olarak değerlendirildiği gibi.
<D> Teknik Yapı Dosyasında belirtildiği gibi ve <G> Sertifikasına göre
<E> tarafından olumlu olarak (Uygulanan modül <F>) değerlendirilmiştir.
Risk kategorisi <H>. Ayrıca bir sonraki sayfaya bakın.
**
sertifikaadile<C>.
nagu on näidatud tehnilises dokumentatsioonis <D> ja heaks kiidetud
<E> järgi (lisamoodul <F>) vastavalt sertifikaadile <G>. Riskikategooria
<H>. Vaadake ka järgmist lehekülge.
както е изложено в <A> и оценено положително от <B> съгласно
Сертификата<C>.
както е заложено в Акта за техническа конструкция <D> и оценено
положително от <E> (Приложен модул <F>) съгласно Сертификат
<G>. Категория риск <H>. Вижте също на следващата страница.
kaip nustatyta <A> ir kaip teigiamai nuspręsta <B> pagal
**
21*
**
Sertifikatą<C>.
22*
kaip nurodyta Techninėje konstrukcijos byloje <D> ir patvirtinta <E>
(taikomas modulis <F>) pagal pažymėjimą <G>. Rizikos kategorija <H>.
Taip pat žiūrėkite ir kitą puslapį.
kā norādīts <A> un atbilstoši <B> pozitīvajam vērtējumam saskaņā
arsertifikātu<C>.
kā noteikts tehniskajā dokumentācijā <D>, atbilstoši <E> pozitīvajam
lēmumam (piekritīgā sadaĮa: <F>), ko apliecina sertifikāts <G>. Riska
**
kategorija <H>. Skat. arī nākošo lappusi.
23*
**
Daikin Europe N.V. je pooblaščen za sestavo datoteke s tehnično mapo.
Daikin Europe N.V. on volitatud koostama tehnilist dokumentatsiooni.
Daikin Europe N.V. е оторизирана да състави Акта за техническа конструкция.
Daikin Europe N.V. yra įgaliota sudaryti šį techninės konstrukcijos failą.
Daikin Europe N.V. ir autorizēts sastādīt tehnisko dokumentāciju.
Spoločnosť Daikin Europe N.V. je oprávnená vytvoriť súbor technickej konštrukcie.
Daikin Europe N.V. Teknik Yapı Dosyasını derlemeye yetkilidir.
19***
20***
21***
22***
23***
24***
25***
respektive utstyr er i overensstemmelse med følgende standard(er) eller
andre normgivende dokument(er), under forutssetning av at disse brukes
i henhold til våre instrukser:
vastaavat seuraavien standardien ja muiden ohjeellisten dokumenttien
vaatimuksia edellyttäen, että niitä käytetään ohjeidemme mukaisesti:
za předpokladu, že jsou využívány v souladu s našimi pokyny, odpovídají
následujícím normám nebo normativním dokumentům:
u skladu sa slijedećim standardom(ima) ili drugim normativnim
dokumentom(ima), uz uvjet da se oni koriste u skladu s našim uputama:
megfelelnek az alábbi szabvány(ok)nak vagy egyéb irányadó
12
131415
dokumentum(ok)nak, ha azokat előírás szerint használják:
16
jak bylo uvedeno v <A> a pozitivně zjištěno <B> vsouladu
sosvědčením<C>.
jak bylo uvedeno v souboru technické konstrukce <D> a pozitivně
zjištěno <E> (použitý modul <F>) v souladu s osvědčením <G>.
Kategorie rizik <H>. Viztakénásledující strana.
kako je izloženo u <A> i pozitivno ocijenjeno odstrane <B> prema
14*
Certifikatu<C>.
**
15*
kako je izloženo u Datoteci o tehničkoj konstrukciji <D> i pozitivno
ocijenjeno od strane <E> (Primijenjen modul <F>) prema Certifikatu
<G>. Kategorija opasnosti <H>. Također pogledajte na slijedećoj stranici.
a(z) <A> alapján, a(z) <B> igazolta a megfelelést, a(z) <C>tanúsítvány
szerint.
a(z) <D> műszaki konstrukciós dokumentáció alapján, a(z) <E> igazolta
a megfelelést (alkalmazott modul: <F>), a(z) <G> tanúsítvány szerint.
Veszélyességikategória <H>. Lásd még a következő oldalon.
zgodnie z dokumentacją <A>, pozytywną opinią <B> i
Świadectwem<C>.
**
16*
**
zgodnie z archiwalną dokumentacją konstrukcyjną <D> i pozytywną
17*
**
Machinery 2006/42/EC
Pressure Equipment 2014/68/EU
Electromagnetic Compatibility 2014/30/EU
заявляет, исключительно под свою ответственность, что модели кондиционеров воздуха, к которым относится настоящее заявление:
erklærer under eneansvar, at klimaanlægmodellerne, som denne deklaration vedrører:
deklarerar i egenskap av huvudansvarig, att luftkonditioneringsmodellerna som berörs av denna deklaration innebär att:
erklærer et fullstendig ansvar for at de luftkondisjoneringsmodeller som berøres av denne deklarasjon, innebærer at:
ilmoittaa yksinomaan omalla vastuullaan, että tämän ilmoituksen tarkoittamat ilmastointilaitteiden mallit:
prohlašuje ve své plné odpovědnosti, že modely klimatizace, k nimž se toto prohlášení vztahuje:
izjavljuje pod isključivo vlastitom odgovornošću da su modeli klima uređaja na koje se ova izjava odnosi:
teljes felelőssége tudatában kijelenti, hogy a klímaberendezés modellek, melyekre e nyilatkozat vonatkozik:
09
10
11
12
13
14
15
16
соответствуют следующим стандартам или другим нормативным
документам, при условии их использования согласно нашим
инструкциям:
overholder følgende standard(er) eller andet/andre
retningsgivende dokument(er), forudsat at disse anvendes i henhold til
vore instrukser:
respektive utrustning är utförd i överensstämmelse med och
följer följande standard(er) eller andra normgivande dokument, under
förutsättning att användning sker i överensstämmelse med våra
09
10
están en conformidad con la(s) siguiente(s) norma(s) u otro(s)
documento(s) normativo(s), siempre que sean utilizados de acuerdo con
nuestras instrucciones:
sono conformi al(i) seguente(i) standard(s) o altro(i) documento(i) a
carattere normativo, a patto che vengano usati in conformità alle nostre
05
06
instruktioner:
11
ob upoštevanju določb:
vastavalt nõuetele:
следвайки клаузите на:
laikantis nuostatų, pateikiamų:
ievērojot prasības, kas noteiktas:
19202122232425
istruzioni:
είναι σύμφωνα με το(α) ακόλουθο(α) πρότυπο(α) ή άλλο έγγραφο(α)
κανονισμών, υπό την προϋπόθεση ότι χρησιμοποιούνται σύμφωνα με τις
οδηγίες μας:
estão em conformidade com a(s) seguinte(s) norma(s) ou outro(s)
documento(s) normativo(s), desde que estes sejam utilizados de acordo
07
com as nossas instruções:
08
održiavajúc ustanovenia:
как указано в <A> и в соответствии сположительным решением <B>
согласно Свидетельству<C>.
как указано в Досье технического топкования <D> и в соответствии
сположительным решением <E>
09*
**
bunun koşullarına uygun olarak:
como se establece en <A> y es valorado positivamente por <B>
deacuerdo con el Certificado<C>.
tal como se expone en el Archivo de Construcción Técnica <D>
yjuzgado positivamento por <E> (Modulo aplicado <F>) según el
05*
**
(Прикладной модуль <F>) согласно Свидетельству <G>. Категория
риска <H>. Также смотрите следующую страницу.
som anført i <A> og positivt vurderet af <B> ihenhold til Certifikat<C>.
som anført i den Tekniske Konstruktionsfil <D> og positivt vurderet af
<E> (Anvendt modul <F>) i henhold til Certifikat <G>. Risikoklasse <H>.
Se også næste side.
enligt <A> och godkänts av <B> enligt Certifikatet<C>.
i enlighet med den Tekniska Konstruktionsfilen <D> som positivt intygats
av <E> (Fastsatt modul <F>) vilket också framgår av Certifikat <G>.
Riskkategori <H>. Seäven nästa sida.
som det fremkommer i <A> og gjennom positiv bedømmelse av <B>
ifølge Sertifikat<C>.
som det fremkommer i den Tekniske Konstruksjonsfilen <D> og gjennom
10*
**
11*
**
Certificado <G>. Categoría de riesgo <H>. Consulte también la siguiente
página.
delineato nel <A> e giudicato positivamente da<B> secondo
ilCertificato<C>.
delineato nel File Tecnico di Costruzione <D> e giudicato positivamente
da <E> (Modulo <F> applicato) secondo il Certificato <G>. Categoria
dirischio <H>. Fare riferimento anche alla pagina successiva.
όπως καθορίζεται στο <A> και κρίνεται θετικά από το <B> σύμφωνα με
**
το Πιστοποιητικό<C>.
07*
06*
positiv bedømmelse av <E> (Anvendt modul <F>) ifølge Sertifikat <G>.
12*
**
όπως προσδιορίζεται στο Αρχείο Τεχνικής Κατασκευής <D> και κρίνεται
θετικά από το <E> (Χρησιμοποιούμενη υπομονάδα <F>) σύμφωνα με το
Πιστοποιητικό <G>. Κατηγορία επικινδυνότητας <H>. Ανατρέξτε επίσης
στην επόμενη σελίδα.
tal como estabelecido em <A> e com o parecer positivo de <B>
**
08*
Daikin Europe N.V. on valtuutettu laatimaan Teknisen asiakirjan.
opinią <E> (Zastosowany moduł <F>) zgodnie ze Świadectwem <G>.
Kategoria zagrożenia<H>. Patrz także następna strona.
aşa cum este stabilit în <A> şi apreciat pozitiv de<B> în conformitate cu
Certificatul<C>.
conform celor stabilite în Dosarul tehnic de construcţie <D> şiapreciate
pozitiv de<E> (Modul aplicat <F>) în conformitate cu Certificatul <G>.
18*
**
Risikokategori <H>. Se også neste side.
jotka on esitetty asiakirjassa <A> ja jotka <B> on hyväksynyt
Sertifikaatin<C> mukaisesti.
jotka on esitetty Teknisessä Asiakirjassa <D> ja jotka <E> on hyväksynyt
(Sovellettu moduli <F>) Sertifikaatin <G> mukaisesti. Vaaraluokka <H>.
Katsomyös seuraava sivu.
13*
**
deacordo com o Certificado<C>.
tal como estabelecido no Ficheiro Técnico de Construção <D> ecomo
parecer positivo de <E> (Módulo aplicado <F>) de acordo com o
Certificado <G>. Categoria de risco <H>. Consultar também a página
seguinte.
**
13***
Categorie derisc<H>. Consultaţi de asemenea pagina următoare.
Η Daikin Europe N.V. είναι εξουσιοδοτημένη να συντάξει τον Τεχνικό φάκελο κατασκευής.
07***
Společnost Daikin Europe N.V. má oprávnění ke kompilaci souboru technické konstrukce.
Daikin Europe N.V. je ovlašten za izradu Datoteke o tehničkoj konstrukciji.
A Daikin Europe N.V. jogosult a műszaki konstrukciós dokumentáció összeállítására.
Daikin Europe N.V. ma upoważnienie do zbierania i opracowywania dokumentacji konstrukcyjnej.
Daikin Europe N.V. este autorizat să compileze Dosarul tehnic de construcţie.
14***
15***
16***
17***
18***
A Daikin Europe N.V. está autorizada a compilar a documentação técnica de fabrico.
Компания Daikin Europe N.V. уполномочена составить Комплект технической документации.
Daikin Europe N.V. er autoriseret til at udarbejde de tekniske konstruktionsdata.
Daikin Europe N.V. är bemyndigade att sammanställa den tekniska konstruktionsfilen.
Daikin Europe N.V. har tillatelse til å kompilere den Tekniske konstruksjonsfilen.
08***
09***
10***
11***
12***
declares under its sole responsibility that the air conditioning models to which this declaration relates:
erklärt auf seine alleinige Verantwortung daß die Modelle der Klimageräte für die diese Erklärung bestimmt ist:
CE - DECLARATION-OF-CONFORMITY CE - DECLARACION-DE-CONFORMIDAD CE - DECLARAÇÃO-DE-CONFORMIDADE CE - ERKLÆRING OM-SAMSVAR CE - IZJAVA-O-USKLAĐENOSTI CE - IZJAVA O SKLADNOSTI CE - ATITIKTIES-DEKLARACIJA
CE - KONFORMITÄTSERKLÄRUNG CE - DICHIARAZIONE-DI-CONFORMITA CE - ЗАЯВЛЕНИЕ-О-СООТВЕТСТВИИ CE - ILMOITUS-YHDENMUKAISUUDESTA CE - MEGFELELŐSÉGI-NYILATKOZAT CE - VASTAVUSDEKLARATSIOON CE - ATBILSTĪBAS-DEKLARĀCIJA
CE - DECLARATION-DE-CONFORMITE CE - ΔHΛΩΣΗ ΣΥΜΜΟΡΦΩΣΗΣ CE - OVERENSSTEMMELSESERKLÆRING CE - PROHLÁŠENÍ-O-SHODĚ CE - DEKLARACJA-ZGODNOŚCI CE - ДЕКЛАРАЦИЯ-ЗА-СЪОТВЕТСТВИЕ CE - VYHLÁSENIE-ZHODY
CE - CONFORMITEITSVERKLARING CE - FÖRSÄKRAN-OM-ÖVERENSTÄMMELSE CE - DECLARAŢIE-DE-CONFORMITATE CE - UYGUNLUK-BEYANI
déclare sous sa seule responsabilité que les appareils d'air conditionné visés par la présente déclaration:
Daikin Europe N.V.
01
02
03
under iagttagelse af bestemmelserne i:
enligt villkoren i:
gitt i henhold til bestemmelsene i:
noudattaen määräyksiä:
za dodržení ustanovení předpisu:
prema odredbama:
követi a(z):
zgodnie z postanowieniami Dyrektyw:
101112131415161718
verklaart hierbij op eigen exclusieve verantwoordelijkheid dat de airconditioning units waarop deze verklaring betrekking heeft:
declara baja su única responsabilidad que los modelos de aire acondicionado a los cuales hace referencia la declaración:
dichiara sotto sua responsabilità che i condizionatori modello a cui è riferita questa dichiarazione:
δηλώνει με αποκλειστική της ευθύνη ότι τα μοντέλα των κλιματιστικών συσκευών στα οποία αναφέρεται η παρούσα δήλωση:
declara sob sua exclusiva responsabilidade que os modelos de ar condicionado a que esta declaração se refere:
REYQ8U7Y1B*, REYQ10U7Y1B*, REYQ12U7Y1B*, REYQ14U7Y1B*, REYQ16U7Y1B*, REYQ18U7Y1B*, REYQ20U7Y1B*,
REMQ5U7Y1B*,
04
05
06
07
08
* = , , 1, 2, 3, ..., 9
are in conformity with the following standard(s) or other normative
document(s), provided that these are used in accordance with our
instructions:
der/den folgenden Norm(en) oder einem anderen Normdokument oder -
dokumenten entspricht/entsprechen, unter der Voraussetzung, daß sie
gemäß unseren Anweisungen eingesetzt werden:
sont conformes à la/aux norme(s) ou autre(s) document(s) normatif(s),
pour autant qu'ils soient utilisés conformément à nos instructions:
conform de volgende norm(en) of één of meer andere bindende
documenten zijn, op voorwaarde dat ze worden gebruikt overeenkomstig
01
02
03
onze instructies:
04
following the provisions of:
gemäß den Vorschriften der:
conformément aux stipulations des:
EN60335-2-40,
overeenkomstig de bepalingen van:
010203040506070809
în urma prevederilor:
as set out in <A> and judged positively by <B> according to the
Certificate<C>.
as set out in the Technical Construction File <D> and judged positively by
<E> (Applied module <F>) according to the Certificate <G>. Risk
category <H>. Also refer to next page.
wie in <A> aufgeführt und von <B> positiv beurteilt gemäß
siguiendo las disposiciones de:
secondo le prescrizioni per:
με τήρηση των διατάξεων των:
de acordo com o previsto em:
в соответствии с положениями:
01*
**
Zertifikat<C>.
02*
wie in der Technischen Konstruktionsakte <D> aufgeführt und von <E>
(Angewandtes Modul <F>) positiv ausgezeichnet positiv ausgezeichnet
gemäß Zertifikat <G>. Risikoart <H>. Siehe auch nächste Seite.
tel que défini dans <A> et évalué positivement par <B> conformément au
Certificat<C>.
tel que stipulé dans le Fichier de Construction Technique <D> et jugé
03*
positivement par <E> (Module appliqué <F>) conformément au Certificat
**
**
<G>. Catégorie de risque <H>. Se reporter également à la page
suivante.
zoals vermeld in <A> en positief beoordeeld door <B> overeenkomstig
Certificaat<C>.
zoals vermeld in het Technisch Constructiedossier <D> en
inordebevonden door <E> (Toegepaste module <F>) overeenkomstig
Certificaat <G>. Risicocategorie <H>. Zie ook de volgende pagina.
04*
**
Daikin Europe N.V. is authorised to compile the Technical Construction File.
Daikin Europe N.V. hat die Berechtigung die Technische Konstruktionsakte zusammenzustellen.
Daikin Europe N.V. est autorisé à compiler le Dossier de Construction Technique.
Daikin Europe N.V. is bevoegd om het Technisch Constructiedossier samen te stellen.
Daikin Europe N.V. está autorizado a compilar el Archivo de Construcción Técnica.
Daikin Europe N.V. è autorizzata a redigere il File Tecnico di Costruzione.
01***
02***
03***
04***
05***
06***
2P546224-3A
22 ankstesnio puslapio tęsinys:
<K>
<L>
<M>
TSmin
TSmax
PS
<N>
<P>
40
–30
63
R410A
40 bar
°C
°C
bar
<Q> VINÇOTTE nv
Jan Olieslagerslaan 35
1800 Vilvoorde, Belgium
23 iepriekšējās lappuses turpinājums:
24 pokračovanie z predchádzajúcej strany:
25 önceki sayfadan devam:
Maximálny povolený tlak (PS): <K> (bar)
∙ 24
Deklaratsiooni alla kuuluvate mudelite disainispetsifikatsioonid:
Проектни спецификации на моделите, за които се отнася декларацията:
Konstrukcinės specifikacijos modelių, kurie susiję su šia deklaracija:
To modeļu dizaina specifikācijas, uz kurām attiecas šī deklarācija:
Konštrukčné špecifikácie modelu, ktorého sa týka toto vyhlásenie:
2021222324
19 nadaljevanje s prejšnje strani:
20 eelmise lehekülje järg:
21 продължение от предходната страница:
15 nastavak s prethodne stranice:
16 folytatás az előző oldalról:
17 ciąg dalszy z poprzedniej strony:
18 continuarea paginii anterioare:
Tätä ilmoitusta koskevien mallien rakennemäärittely: 13141516171819
Bu bildirinin ilgili olduğu modellerin Tasarım Özellikleri: 25
Maksimalni dovoljeni tlak (PS): <K> (bar)
∙ 19
Specifikace designu modelů, ke kterým se vztahuje toto prohlášení:
Specifikacije dizajna za modele na koje se ova izjava odnosi:
A jelen nyilatkozat tárgyát képező modellek tervezési jellemzői:
Specyfikacje konstrukcyjne modeli, których dotyczy deklaracja:
Najveći dopušten tlak (PS): <K> (bar)
Specificaţiile de proiectare ale modelelor la care se referă această declaraţie:
Specifikacije tehničnega načrta za modele, na katere se nanaša ta deklaracija:
∙ 15
Minimálna/maximálna povolená teplota (TS*):
*TSmin: Minimálna teplota na nízkotlakovej strane: <L> (°C)
*TSmax: Nasýtená teplota korešpondujúca s maximálnym povoleným
tlakom (PS): <M> (°C)
Chladivo: <N>
Nastavenie tlakového poistného zariadenia: <P> (bar)
Výrobné číslo a rok výroby: nájdete na výrobnom štítku modelu
İzin verilen maksimum basınç (PS): <K> (bar)
İzin verilen minimum/maksimum sıcaklık (TS*):
*TSmin: Düşük basınç tarafındaki minimum sıcaklık: <L> (°C)
*TSmax: İzin verilen maksimum basınca (PS) karşı gelen doyma
sıcaklığı: <M> (°C)
Soğutucu: <N>
Basınç emniyet düzeninin ayarı: <P> (bar)
∙∙∙∙∙
25
Minimalna/maksimalna dovoljena temperatura (TS*):
*TSmin: Minimalna temperatura na nizkotlačni strani: <L> (°C)
*TSmax: Nasičena temperatura, ki ustreza maksimalnemu dovoljenemu
tlaku (PS): <M> (°C)
Hladivo: <N>
Nastavljanje varnostne naprave za tlak: <P> (bar)
Tovarniška številka in leto proizvodnje: glejte napisno ploščico
Maksimaalne lubatud surve (PS): <K> (bar)
Minimaalne/maksimaalne lubatud temperatuur (TS*):
∙∙∙∙∙
Najniža/najviša dopuštena temperatura (TS*):
*TSmin: Najniža temperatura u području niskog tlaka: <L> (°C)
*TSmax: Standardna temperatura koja odgovara najvećem dopuštenom
tlaku (PS): <M> (°C)
Rashladno sredstvo: <N>
∙∙∙∙∙
*TSmin: Minimaalne temperatuur madalsurve küljel: <L> (°C)
20
Postavke sigurnosne naprave za tlak: <P> (bar)
Proizvodni broj i godina proizvodnje: pogledajte natpisnu pločicu modela
Legnagyobb megengedhető nyomás (PS): <K> (bar)
Legkisebb/legnagyobb megengedhető hőmérséklet (TS*):
*TSmin: Legkisebb megengedhető hőmérséklet a kis nyomású oldalon:
16
İmalat numarası ve imalat yılı: modelin ünite plakasına bakın
∙∙∙
*TSmax: Maksimaalsele lubatud survele (PS) vastav küllastunud
temperatuur: <M> (°C)
Jahutusaine: <N>
Surve turvaseadme seadistus: <P> (bar)
Tootmisnumber ja tootmisaasta: vaadake mudeli andmeplaati
Максимално допустимо налягане (PS): <K> (bar)
Минимално/максимално допустима температура (TS*):
*TSmin: Минимална температура от страната на ниското налягане:
<L> (°C)
*TSmax: Температура на насищане, съответстваща на максимално
допустимото налягане (PS): <M> (°C)
Охладител: <N>
Настройка на предпазното устройство за налягане: <P> (bar)
Фабричен номер и година на производство: вижте табелката
намодела
Maksimalus leistinas slėgis (PS): <K> (bar)
Minimali/maksimali leistina temperatūra (TS*):
∙∙∙∙∙
21
<L> (°C)
*TSmax: A legnagyobb megengedhető nyomásnak (PS) megfelelő
telítettségi hőmérséklet: <M> (°C)
Hűtőközeg: <N>
A túlnyomás-kapcsoló beállítása: <P> (bar)
Gyártási szám és gyártási év: lásd a berendezés adattábláján
Maksymalne dopuszczalne ciśnienie (PS): <K> (bar)
∙∙∙∙∙
17
∙∙∙∙∙
Minimalna/maksymalna dopuszczalna temperatura (TS*):
*TSmin: Minimalna temperatura po stronie niskociśnieniowej: <L> (°C)
*TSmax: Temperatura nasycenia odpowiadająca maksymalnemu
dopuszczalnemu ciśnieniu (PS): <M> (°C)
Czynnik chłodniczy: <N>
Nastawa ciśnieniowego urządzenia bezpieczeństwa: <P> (bar)
∙∙∙∙∙
*TSmin: Minimali temperatūra žemo slėgio pusėje: <L> (°C)
22
Numer fabryczny oraz rok produkcji: patrz tabliczka znamionowa modelu
Presiune maximă admisibilă (PS): <K> (bar)
Temperatură minimă/maximă admisibilă (TS*):
*TSmin: Temperatură minimă pe partea de presiune joasă: <L> (°C)
*TSmax: Temperatură de saturaţie corespunzând presiunii maxime
18
Názov a adresa certifikačného úradu, ktorý kladne posúdil zhodu so
smernicou pre tlakové zariadenia: <Q>
Basınçlı Teçhizat Direktifine uygunluk hususunda olumlu olarak
değerlendirilen Onaylanmış kuruluşun adı ve adresi: <Q>
24
25
*TSmax: Prisotinta temperatūra, atitinkamti maksimalų leistiną slėgį
(PS): <M> (°C)
Šaldymo skystis: <N>
Apsauginio slėgio prietaiso nustatymas: <P> (bar)
Gaminio numeris ir pagaminimo metai: žiūrėkite modelio pavadinimo
plokštelę
Maksimālais pieļaujamais spiediens (PS): <K> (bar)
Minimālā/maksimālā pieļaujamā temperatūra (TS*):
*TSmin: Minimālā temperatūra zemā spiediena pusē: <L> (°C)
*TSmax: Piesātinātā temperatūra saskaņā ar maksimālo pieļaujamo
spiedienu (PS): <M> (°C)
Dzesinātājs: <N>
Spiediena drošības ierīces iestatīšana: <P> (bar)
Izgatavošanas numurs un izgatavošanas gads: skat. modeļa
izgatavotājuzņēmuma plāksnītie
Ime in naslov organa za ugotavljanje skladnosti, ki je pozitivno ocenil
združljivost z Direktivo o tlačni opremi: <Q>
Teavitatud organi, mis hindas Surveseadmete Direktiiviga ühilduvust
positiivselt, nimi ja aadress: <Q>
Наименование и адрес на упълномощения орган, който
сеепроизнесъл положително относно съвместимостта
сДирективата за оборудване под налягане: <Q>
Atsakingos institucijos, kuri davė teigiamą sprendimą pagal slėginės
įrangos direktyvą pavadinimas ir adresas: <Q>
Sertifikācijas institūcijas, kura ir devusi pozitīvu slēdzienu par atbilstību
∙∙∙∙∙
23
admisibile (PS): <M> (°C)
Agent frigorific: <N>
Reglarea dispozitivului de siguranţă pentru presiune: <P> (bar)
Numărul de fabricaţie şi anul de fabricaţie: consultaţi placa de identificare
a modelului
∙∙∙
∙∙∙
192021
Název a adresa informovaného orgánu, který vydal pozitivní posouzení
shody se směrnicí o tlakových zařízeních: <Q>
Naziv i adresa prijavljenog tijela koje je donijelo pozitivnu prosudbu o
usklađenosti sa Smjernicom za tlačnu opremu: <Q>
A nyomástartó berendezésekre vonatkozó irányelvnek való
141516
megfelelőséget igazoló bejelentett szervezet neve és címe: <Q>
Spiediena lekārtu Direktīvai, nosaukums un
22
23
Nazwa i adres Jednostki notyfikowanej, która wydała pozytywną opinię
dotyczącą spełnienia wymogów Dyrektywy dot. Urządzeń Ciśnieniowych:
<Q>
Denumirea şi adresa organismului notificat care a apreciat pozitiv
conformarea cu Directiva privind echipamentele sub
17
18
adrese: <Q>
presiune: <Q>
12 fortsettelse fra forrige side:
13 jatkoa edelliseltä sivulta:
14 pokračování z předchozí strany:
08 continuação da página anterior:
09 продолжение предыдущей страницы:
10 fortsat fra forrige side:
11 fortsättning från föregående sida:
Προδιαγραφές Σχεδιασμού των μοντέλων με τα οποία σχετίζεται η δήλωση:
Especificações de projecto dos modelos a que se aplica esta declaração:
Проектные характеристики моделей, к которым относится настоящее заявление:
0708091011
05 continuación de la página anterior:
06 continua dalla pagina precedente:
07 συνέχεια από την προηγούμενη σελίδα:
Maks. tilladt tryk (PS): <K> (bar)
Min./maks. tilladte temperatur (TS*):
*TSmin: Min. temperatur på lavtrykssiden: <L> (°C)
*TSmax: Mættet temperatur svarende til maks. tilladte tryk (PS): <M>
(°C)
Kølemiddel: <N>
Indstilling af tryksikringsudstyr: <P> (bar)
Produktionsnummer og fremstillingsår: se modellens fabriksskilt
Maximalt tillåtet tryck (PS): <K> (bar)
Min/max tillåten temperatur (TS*):
*TSmin: Minimumtemperatur på lågtryckssidan: <L> (°C)
*TSmax: Mättnadstemperatur som motsvarar maximalt tillåtet tryck (PS):
<M> (°C)
Köldmedel: <N>
Inställning för trycksäkerhetsenhet: <P> (bar)
Tillverkningsnummer och tillverkningsår: se modellens namnplåt
Maksimalt tillatt trykk (PS): <K> (bar)
Minimalt/maksimalt tillatt temperatur (TS*):
*TSmin: Minimumstemperatur på lavtrykkssiden: <L> (°C)
*TSmax: Metningstemperatur i samsvar med maksimalt tillatt trykk (PS):
<M> (°C)
Kjølemedium: <N>
Innstilling av sikkerhetsanordning for trykk: <P> (bar)
Produksjonsnummer og produksjonsår: se modellens merkeplate
Suurin sallittu paine (PS): <K> (bar)
Pienin/suurin sallittu lämpötila (TS*):
*TSmin: Alhaisin matalapainepuolen lämpötila: <L> (°C)
*TSmax: Suurinta sallittua painetta (PS) vastaava kyllästyslämpötila:
<M> (°C)
10
Typespecifikationer for de modeller, som denne erklæring vedrører:
Designspecifikationer för de modeller som denna deklaration gäller:
Konstruksjonsspesifikasjoner for de modeller som berøres av denne deklarasjonen: 12
Pressione massima consentita (PS): <K> (bar)
∙ 06
∙∙∙∙∙
11
Temperatura minima/massima consentita (TS*):
*TSmin: temperatura minima nel lato di bassa pressione: <L> (°C)
*TSmax: temperatura satura corrispondente alla pressione massima
consentita (PS): <M> (°C)
Refrigerante: <N>
Impostazione del dispositivo di controllo della pressione: <P> (bar)
Numero di serie e anno di produzione: fare riferimento alla targhetta del
modello
∙∙∙∙∙
∙∙∙∙∙
12
Mέγιστη επιτρεπόμενη πίεση (PS): <K> (bar)
Ελάχιστη/μέγιστη επιτρεπόμενη θερμοκρασία (TS*):
*TSmin: Ελάχιστη θερμοκρασία για την πλευρά χαμηλής πίεσης: <L>
(°C)
*TSmax: Κορεσμένη θερμοκρασία που αντιστοιχεί με τη μέγιστη
επιτρεπόμενη πίεση (PS): <M> (°C)
Ψυκτικό: <N>
Ρύθμιση της διάταξης ασφάλειας πίεσης: <P> (bar)
07
∙∙∙∙∙
∙∙∙∙∙
13
Αριθμός κατασκευής και έτος κατασκευής: ανατρέξτε στην πινακίδα
αναγνώρισης του μοντέλου
Pressão máxima permitida (PS): <K> (bar)
Temperaturas mínima e máxima permitidas (TS*):
*TSmin: Temperatura mínima em baixa pressão: <L> (°C)
*TSmax: Temperatura de saturação correspondente à pressão máxima
permitida (PS): <M> (°C)
Refrigerante: <N>
08
∙∙∙∙∙
Kylmäaine: <N>
∙∙∙∙∙
Regulação do dispositivo de segurança da pressão: <P> (bar)
Número e ano de fabrico: consultar a placa de especificações
daunidade
Максимально допустимое давление (PS): <K> (бар)
Минимально/Максимально допустимая температура (TS*):
09
Varmuuspainelaitteen asetus: <P> (bar)
Valmistusnumero ja valmistusvuosi: katso mallin nimikilpi
Maximální přípustný tlak (PS): <K> (bar)
Minimální/maximální přípustná teplota (TS*):
*TSmin: Minimální teplota na nízkotlaké straně: <L> (°C)
*TSmax: Saturovaná teplota odpovídající maximálnímu přípustnému
tlaku (PS): <M> (°C)
Chladivo: <N>
Nastavení bezpečnostního tlakového zařízení: <P> (bar)
Výrobní číslo a rok výroby: viz typový štítek modelu
14
*TSmin: Минимальная температура на стороне низкого давления:
<L> (°C)
*TSmax: Температура кипения, соответствующая максимально
∙∙∙
допустимому давлению (PS): <M> (°C)
Хладагент: <N>
Настройка устройства защиты по давлению: <P> (бар)
Заводской номер и год изготовления: смотрите паспортную табличку
модели
∙∙∙
Navn og adresse på bemyndiget organ, der har foretaget en positiv
bedømmelse af, at udstyret lever op til kravene i PED (Direktiv for
Trykbærende Udstyr): <Q>
Namn och adress för det anmälda organ som godkänt uppfyllandet av
tryckutrustningsdirektivet: <Q>
Navn på og adresse til det autoriserte organet som positivt bedømte
samsvar med direktivet for trykkutstyr (Pressure Equipment Directive):
<Q>
Sen ilmoitetun elimen nimi ja osoite, joka teki myönteisen päätöksen
10
11
Nome e indirizzo dell’Ente riconosciuto che ha riscontrato la conformità
alla Direttiva sulle apparecchiature a pressione: <Q>
Όνομα και διεύθυνση του Κοινοποιημένου οργανισμού που απεφάνθη
θετικά για τη συμμόρφωση προς την Οδηγία Εξοπλισμών υπό Πίεση:
<Q>
06
07
painelaitedirektiivin noudattamisesta: <Q>
12
13
Nome e morada do organismo notificado, que avaliou favoravelmente a
conformidade com a directiva sobre equipamentos pressurizados: <Q>
Название и адрес органа технической экспертизы, принявшего
положительное решение о соответствии Директиве об оборудовании
под давлением: <Q>
08
09
Hiromitsu Iwasaki
Director
Ostend, 1st of March 2019
CE - DECLARATION-OF-CONFORMITY CE - DECLARACION-DE-CONFORMIDAD CE - DECLARAÇÃO-DE-CONFORMIDADE CE - ERKLÆRING OM-SAMSVAR CE - IZJAVA-O-USKLAĐENOSTI CE - IZJAVA O SKLADNOSTI CE - ATITIKTIES-DEKLARACIJA
CE - KONFORMITÄTSERKLÄRUNG CE - DICHIARAZIONE-DI-CONFORMITA CE - ЗАЯВЛЕНИЕ-О-СООТВЕТСТВИИ CE - ILMOITUS-YHDENMUKAISUUDESTA CE - MEGFELELŐSÉGI-NYILATKOZAT CE - VASTAVUSDEKLARATSIOON CE - ATBILSTĪBAS-DEKLARĀCIJA
CE - DECLARATION-DE-CONFORMITE CE - ΔHΛΩΣΗ ΣΥΜΜΟΡΦΩΣΗΣ CE - OVERENSSTEMMELSESERKLÆRING CE - PROHLÁŠENÍ-O-SHODĚ CE - DEKLARACJA-ZGODNOŚCI CE - ДЕКЛАРАЦИЯ-ЗА-СЪОТВЕТСТВИЕ CE - VYHLÁSENIE-ZHODY
CE - CONFORMITEITSVERKLARING CE - FÖRSÄKRAN-OM-ÖVERENSTÄMMELSE CE - DECLARAŢIE-DE-CONFORMITATE CE - UYGUNLUK-BEYANI
01 continuation of previous page:
02 Fortsetzung der vorherigen Seite:
03 suite de la page précédente:
04 vervolg van vorige pagina:
Maximum allowable pressure (PS): <K> (bar)
Minimum/maximum allowable temperature (TS*):
*TSmin: Minimum temperature at low pressure side: <L> (°C)
*TSmax: Saturated temperature corresponding with the maximum
allowable pressure (PS): <M> (°C)
Refrigerant: <N>
Setting of pressure safety device: <P> (bar)
Manufacturing number and manufacturing year: refer to model nameplate
Maximal zulässiger Druck (PS): <K> (Bar)
Minimal/maximal zulässige Temperatur (TS*):
*TSmin: Mindesttemperatur auf der Niederdruckseite: <L> (°C)
*TSmax: Sättigungstemperatur die dem maximal zulässigen Druck (PS)
entspricht: <M> (°C)
Kältemittel: <N>
Einstellung der Druck-Schutzvorrichtung: <P> (Bar)
Herstellungsnummer und Herstellungsjahr: siehe Typenschild
desModells
Pression maximale admise (PS): <K> (bar)
Température minimum/maximum admise (TS*):
*TSmin: température minimum côté basse pression: <L> (°C)
*TSmax: température saturée correspondant à la pression maximale
admise (PS): <M> (°C)
Réfrigérant: <N>
Réglage du dispositif de sécurité de pression: <P> (bar)
Numéro de fabrication et année de fabrication: se reporter à la plaquette
signalétique du modèle
Maximaal toelaatbare druk (PS): <K> (bar)
Design Specifications of the models to which this declaration relates:
Konstruktionsdaten der Modelle auf die sich diese Erklärung bezieht:
Spécifications de conception des modèles auxquels se rapporte cette déclaration:
Ontwerpspecificaties van de modellen waarop deze verklaring betrekking heeft:
Especificaciones de diseño de los modelos a los cuales hace referencia esta declaración:
Specifiche di progetto dei modelli cui fa riferimento la presente dichiarazione:
0102030405
06
01
∙∙∙∙∙
02
∙∙∙∙∙
03
∙∙∙∙∙
Minimaal/maximaal toelaatbare temperatuur (TS*):
04
*TSmin: Minimumtemperatuur aan lagedrukzijde: <L> (°C)
*TSmax: Verzadigde temperatuur die overeenstemt met de maximaal
toelaatbare druk (PS): <M> (°C)
Koelmiddel: <N>
Instelling van drukbeveiliging: <P> (bar)
Fabricagenummer en fabricagejaar: zie naamplaat model
Presión máxima admisible (PS): <K> (bar)
Temperatura mínima/máxima admisible (TS*):
*TSmin: Temperatura mínima en el lado de baja presión: <L> (°C)
*TSmax: Temperatura saturada correspondiente a la presión máxima
admisible (PS): <M> (°C)
Refrigerante: <N>
Ajuste del presostato de seguridad: <P> (bar)
Número de fabricación y año de fabricación: consulte la placa
deespecificaciones técnicas del modelo
Name and address of the Notified body that judged positively
oncompliance with the Pressure Equipment Directive: <Q>
Name und Adresse der benannten Stelle, die positiv unter Einhaltung der
Druckanlagen-Richtlinie urteilte: <Q>
Nom et adresse de l’organisme notifié qui a évalué positivement la
conformité à la directive sur l’équipement de pression: <Q>
Naam en adres van de aangemelde instantie die positief geoordeeld
heeft over de conformiteit met de Richtlijn Drukapparatuur: <Q>
Nombre y dirección del Organismo Notificado que juzgó positivamente el
∙∙∙∙∙
05
∙∙∙
0102030405
cumplimiento con la Directiva en materia de Equipos de Presión: <Q>
2P546224-3A

Table des matières

Table des matières
1 À propos de la documentation 5
1.1 À propos du présent document ................................................. 5
Pour l'installateur 5
2 À propos du carton 5
2.1 Retrait des accessoires de l'unité extérieure............................. 5
2.2 Tuyaux accessoires: Diamètres ................................................ 6
2.3 Retrait du raidisseur de transport (uniquement pour 14-16 HP) 6
2.4 Retrait du raidisseur de transport (uniquement pour 18+20
HP) ............................................................................................ 6
3 À propos des unités et des options 6
3.1 A propos de l'unité extérieure.................................................... 6
3.2 Configuration du système.......................................................... 7
4 Préparation 7
4.1 Préparation du lieu d'installation................................................ 7
4.1.1 Exigences du site d'installation pour l'unité extérieure 7
4.1.2 Exigences supplémentaires du site d'installation pour
l'unité extérieure dans les climats froids ..................... 7
4.2 Préparation de la tuyauterie de réfrigérant................................ 8
4.2.1 Exigences de la tuyauterie de réfrigérant ................... 8
4.2.2 Pour sélectionner la taille de la tuyauterie .................. 8
4.2.3 Pour sélectionner les kits d'embranchement de
réfrigérant.................................................................... 9
4.2.4 Unités extérieures multiples: Configurations
possibles ..................................................................... 9
4.3 Préparation du câblage électrique............................................. 10
4.3.1 A propos de la conformité électrique .......................... 10
4.3.2 Exigences du dispositif de sécurité............................. 11
5 Installation 11
5.1 Ouverture des unités ................................................................. 11
5.1.1 Pour ouvrir l'unité extérieure ....................................... 11
5.1.2 Pour ouvrir la boîte des composants électrique de
l'unité extérieure.......................................................... 12
5.2 Montage de l'unité extérieure .................................................... 12
5.2.1 Prévoir la structure d'installation ................................. 12
5.3 Raccordement de la tuyauterie de réfrigérant ........................... 13
5.3.1 Acheminement de la tuyauterie de réfrigérant............ 13
5.3.2 Raccordement du tuyau de réfrigérant à l'unité
extérieure .................................................................... 13
5.3.3 Raccordement du kit de tuyauterie à connexions
multiples...................................................................... 13
5.3.4 Unités extérieures multiples: Trous à enfoncer........... 13
5.3.5 Pour protéger de tout encrassement .......................... 13
5.3.6 Utilisation de la vanne d'arrêt et de l'orifice de
service......................................................................... 14
5.3.7 Retirer les tuyaux écrasés .......................................... 14
5.4 Vérification de la tuyauterie de réfrigérant................................. 15
5.4.1 A propos du contrôle de la tuyauterie de réfrigérant... 15
5.4.2 Contrôle du tuyau de réfrigérant: Directives
générales .................................................................... 15
5.4.3 Contrôle du tuyau de réfrigérant: Configuration.......... 15
5.4.4 Réalisation d'un essai de fuite .................................... 16
5.4.5 Réalisation du séchage par le vide............................. 16
5.5 Isolation de la tuyauterie de réfrigérant ..................................... 16
5.6 Charge du réfrigérant ................................................................ 16
5.6.1 Précautions lors de la recharge de réfrigérant............ 16
5.6.2 A propos de la recharge du réfrigérant ....................... 17
5.6.3 Détermination de la quantité de réfrigérant
complémentaire .......................................................... 17
5.6.4 Pour recharger le réfrigérant: Organigramme............. 18
5.6.5 Recharge du réfrigérant.............................................. 20
5.6.6 Etape 6a: Recharge automatique du réfrigérant......... 21
5.6.7 Etape 6b: Pour recharger manuellement le
réfrigérant..................................................................... 22
5.6.8 Codes d'erreur lors de la recharge de réfrigérant ........ 22
5.6.9 Contrôles après la recharge de réfrigérant .................. 22
5.6.10 Mise en place de l'étiquette concernant les gaz
fluorés à effet de serre ................................................. 23
5.7 Raccordement du câblage électrique......................................... 23
5.7.1 Câblage à effectuer: Aperçu ........................................ 23
5.7.2 Directives lors de l'enfoncement des trous à
enfoncer ....................................................................... 23
5.7.3 Acheminement et fixation du câblage de
transmission................................................................. 23
5.7.4 Branchement du câblage de transmission................... 24
5.7.5 Finition du câblage de transmission............................. 24
5.7.6 Acheminement et fixation de l'alimentation électrique . 24
5.7.7 Brancher l’alimentation électrique................................ 25
6 Configuration 25
6.1 Réalisation des réglages sur place ............................................ 25
6.1.1 A propos de la réalisation des réglages sur place ....... 25
6.1.2 composants du réglage sur place................................ 26
6.1.3 Accès aux composants du réglage sur place .............. 26
6.1.4 Accès au mode 1 ou 2 ................................................. 26
6.1.5 Utilisation du mode 1 ................................................... 26
6.1.6 Utilisation du mode 2 ................................................... 27
6.1.7 Mode 1: Réglages de surveillance............................... 27
6.1.8 Mode 2: Réglages sur place ........................................ 27
6.1.9 Raccordement du configurateur PC à l'unité
extérieure ..................................................................... 29
6.2 Utilisation de la fonction de détection de fuite ............................ 29
6.2.1 A propos de la détection de fuite automatique............. 29
7 Mise en service 29
7.1 Précautions lors de la mise en service....................................... 29
7.2 Liste de contrôle avant la mise en service ................................. 29
7.3 A propos du test de fonctionnement........................................... 30
7.4 Exécution d'un test ..................................................................... 30
7.5 Correction après achèvement anormal de l’opération de test.... 31
8 Dépannage 31
8.1 Résolution des problèmes sur la base des codes d'erreur......... 31
8.2 Codes d’erreur: Aperçu .............................................................. 31
9 Données techniques 36
9.1 Espace de service: Unité extérieure........................................... 36
9.2 Schéma de tuyauterie: unité extérieure...................................... 38
9.3 Schéma de câblage: unité extérieure......................................... 40
Pour l'utilisateur 42
10 A propos du système 42
10.1 Configuration du système........................................................... 42
11 Interface utilisateur 42 12 Fonctionnement 43
12.1 Plage de fonctionnement............................................................ 43
12.2 Fonctionnement du système ...................................................... 43
12.2.1 A propos du fonctionnement du système..................... 43
12.2.2 A propos du mode refroidissement, chauffage,
ventilateur uniquement et automatique........................ 43
12.2.3 A propos du mode chauffage....................................... 43
12.2.4 Utilisation du système (SANS commutateur à
distance refroidissement/chauffage) ............................ 43
12.2.5 Utilisation du système (AVEC commutateur à
distance refroidissement/chauffage) ............................ 43
12.3 Utilisation du programme sec..................................................... 44
12.3.1 A propos du programme sec........................................ 44
12.3.2 Utilisation du programme sec (SANS commutateur à
distance refroidissement/chauffage) ............................ 44
Manuel d'installation et d'utilisation
4
REYQ8~20+REMQ5U7Y1B
Récupération de chaleur VRV IV+
4P546222-1 – 2018.09

1 À propos de la documentation

a d
e
3P328191-1
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
REQUEST FOR THE INDICATION OF INSTALLATION INFORMATION
1. RECORD OF INDOOR UNIT MODEL AND INSTALLATION SITE
2. RECORD FOR SETTINGS (CONTENTS SEE INSTALLATION MANUAL)
SETTING
40
30
10
2019
9
29
3938
28
8
1817
7
27
3736
26
6
1615
5
25
3534
23 24
4321
INSTALLATION
MODELNAME
No.
12 13 14
504948474645
6059585756
64636261
11
2221
333231
44434241
5554535251
SITE
INSTALLATION
MODELNAME
No.
SITE
INSTALLATION
MODELNAME
No.
SITE
INSTALLATION
MODELNAME
No.
SITE
INSTALLATION
MODELNAME
No.
SITE
INSTALLATION
MODELNAME
No.
SITE
INSTALLATION
MODELNAME
No.
SITE
3. RECORD OF INSTALLATION DATE
6. AFTER EQUIPPING, PLEASE PUT IT ON THE BACK SIDE OF THE FRONT PLATE.
DAY MONTH YEAR
4. MODEL NAME 5. MANUFACTURING NUMBER
VALUE
REMARK DATE SETTING VALUE REMARK DATE
3P328192-1
3. FOR DETAILS CONCERNING PIPING SELECTION AND CALCULATION OR HOW TO OPERATE THE LEAK DETECTION FUNCTION, PLEASE REFER TO THE INSTALLATION MANUAL.
2. RECORD OF ADDITIONAL REFRIGERANT CHARGE AMOUNT AND RESULT OF LEAK CHECK OPERATION
REQUEST FOR THE INDICATION OF ADDITIONAL REFRIGERANT CHARGING AND LEAK DETECTION OPERATION RESULT
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
1. CALCULATION OF ADDITIONAL REFRIGERANT CHARGING AMOUNT
4. AFTER FILLING IN THIS TABLE, PLEASE PUT IT ON THE SWITCH BOX COVER.
(m) x 0.18(m) x 0.37
kg
OUTDOOR UNIT
(m) x 0.26
(m) x 0.12 (m) x 0.059
(m) x 0.022
ADDITIONAL CHARGING AMOUNT
TOTAL LENGTH OF LIQUID PIPE SIZE O22.2 x 0.37
TOTAL LENGTH OF LIQUID PIPE SIZE O19.1 x 0.26
TOTAL LENGTH OF LIQUID PIPE SIZE O15.9 x 0.18
TOTAL LENGTH OF LIQUID PIPE SIZE O12.7 x 0.12
TOTAL LENGTH OF LIQUID PIPE SIZE O9.5 x 0.059
TOTAL LENGTH OF LIQUID PIPE SIZE O6.4 x 0.022
105%< CR < 130%
50%< CR < 105%
50%< CR < 70% 70%< CR < 85% 85%< CR < 105% 105%< CR < 130%
8HP
Total indoor unit capacity connection ratio (CR)
10-12HP
14-16HP
18-20HP
2.0
1.5
1.5
1.2
1.5
1
1
0.7
1.0
0.5
0.5
0.3
0.5
0
0
0
1.0
0.5
0.5
0.5
0.5
0
0
0
Total indoor unit capacity when piping length <30m
Total indoor unit capacity when piping length >30m
kg
1.3
1.1
0.9
RYYQ18-20
RYYQ14-16
RYYQ8~12
kg
ONLY FOR RYYQ8~20 MODELS
DATE AMOUNT
CALCULATE THE ADDITIONAL REFRIGERANT CHARGING AMOUNT BASED ON THE FORMULA BELOW BEFORE CHARGING.
SHIPMENT (INDICATED ON THE MACHINE NAMEPLATE) AND THE ADDITIONAL AMOUNT SHOWN AS FOLLOWS :
WHEN RE-CHARGING TOTAL AMOUNT OF REFRIGERANT , CHARGE THE TOTAL OF THE AMOUNT CHARGED AT
RESULT LEAK CHECK
DATE AMOUNT RESULT LEAK CHECK
DATE AMOUNT RESULT LEAK CHECK
DATE AMOUNT RESULT LEAK CHECK
c
b
f g
12.3.3 Utilisation du programme sec (AVEC commutateur à
distance refroidissement/chauffage) ........................... 44
12.4 Réglage de la direction d'écoulement de l'air............................ 44
12.4.1 A propos du volet d'écoulement de l'air ...................... 44
12.5 Réglage de l'interface utilisateur maître .................................... 45
12.5.1 A propos du réglage de l'interface utilisateur maître... 45
13 Entretien et réparation 45
13.1 A propos du réfrigérant.............................................................. 45
13.2 Service après-vente et garantie ................................................ 46
13.2.1 Période de garantie..................................................... 46
13.2.2 Inspection et maintenance recommandées ................ 46
14 Dépannage 46
14.1 Codes d’erreur: Aperçu ............................................................. 47
14.2 Symptômes ne constituant pas des dysfonctionnements du
système ..................................................................................... 48
14.2.1 Symptôme: Le système ne fonctionne pas................. 48
14.2.2 Symptôme: L'inversion froid/chaud est impossible ..... 48
14.2.3 Symptôme: Le fonctionnement du ventilateur est
possible, mais le refroidissement et le chauffage ne
fonctionnent pas.......................................................... 48
14.2.4 Symptôme: La vitesse du ventilateur est différente
de celle du réglage...................................................... 48
14.2.5 Symptôme: Le sens du ventilateur est différent de
celui du réglage........................................................... 48
14.2.6 Symptôme: Une fumée blanche sort d'une unité
(unité intérieure).......................................................... 48
14.2.7 Symptôme: Une fumée blanche sort d'une unité
(unité intérieure, unité extérieure) ............................... 48
14.2.8 Symptôme: L'interface utilisateur affiche "U4" ou
"U5" et s’arrête, puis redémarre après quelques
minutes ....................................................................... 49
14.2.9 Symptôme: Bruit des climatiseurs (unité intérieure) ... 49
14.2.10 Symptôme: Bruit des climatiseurs (unité intérieure,
unité extérieure) .......................................................... 49
14.2.11 Symptôme: Bruit des climatiseurs (unité extérieure) .. 49
14.2.12 Symptôme: De la poussière sort de l'unité.................. 49
14.2.13 Symptôme: Les unités peuvent dégager une odeur ... 49
14.2.14 Symptôme: Le ventilateur de l'unité extérieure ne
tourne pas ................................................................... 49
14.2.15 Symptôme: L'affichage indique "88" ........................... 49
14.2.16 Symptôme: Le compresseur de l'unité extérieure ne
s'arrête pas après une courte opération de chauffage 49
14.2.17 Symptôme: L'intérieur d'une unité extérieure est
chaud même lorsque l'unité est arrêtée...................... 49
14.2.18 Symptôme: Il est possible de sentir de l’air chaud
lorsque l’unité est arrêtée............................................ 49
15 Relocalisation 49
16 Mise au rebut 49
1 À propos de la
documentation

1.1 À propos du présent document

Public visé
INFORMATIONS
Cet appareil est destiné à être utilisé par des utilisateurs experts ou formés dans des ateliers, l'industrie légère et les fermes ou à des fins commerciales par des profanes.
Documentation
Le présent document fait partie d'un ensemble. L'ensemble complet comprend les documents suivants:
Précautions de sécurité générales:
▪ Instructions de sécurité à lire avant l'installation ▪ Format: Papier (dans le carton de l'unité extérieure)
Manuel d'installation et d'utilisation de l'unité extérieure:
▪ Instructions d'installation et d'utilisation ▪ Format: Papier (dans le carton de l'unité extérieure)
Guide de référence de l'installateur et de l'utilisateur:
▪ Préparation de l'installation, données de référence, etc. ▪ Instructions détaillées étape par étape et informations de fond
pour une utilisation de base et avancée
▪ Format: Fichiers numériques sur http://www.daikineurope.com/
support-and-manuals/product-information/
Il est possible que les dernières révisions de la documentation fournie soient disponibles sur le site Web Daikin de votre région ou via votre revendeur.
La documentation d'origine est rédigée en anglais. Toutes les autres langues sont des traductions.
Données techniques
▪ Un sous-ensemble des récentes données techniques est
disponible sur le site régional Daikin (accessible au public).
▪ L'ensemble complet des dernières données techniques est
disponible sur l'extranet Daikin (authentification requise).

Pour l'installateur

2 À propos du carton

2.1 Retrait des accessoires de l'unité extérieure

S'assurer que tous les accessoires sont disponibles dans l'unité.
REYQ8~20+REMQ5U7Y1B Récupération de chaleur VRV IV+ 4P546222-1 – 2018.09
a Consignes de sécurité générales b Manuel d'installation et manuel d'utilisation c Etiquette de charge de réfrigérant supplémentaire d Etiquette d'information sur l'installation
Manuel d'installation et d'utilisation
5

3 À propos des unités et des options

ID Øa
ID Øb
ID Øa
OD Øb
ID Øb
ID Øa
ID Øb
ID Øa
ID Øa
ID Øb
ID Øa
OD Øb
1
3
2
1
3
33
2
(x2)
(x2)
121
2
a
b
a
(12.3 N·m)
(12.3 N·m)
(12.3 N·m)
11
4
4
2
222
5
5
3
3
6
6
7
7
a b
d
e c
e Etiquette de gaz à effet de serre fluorés
f Etiquette multilingue de gaz à effet de serre fluorés
g Sac d'accessoires de tuyauterie

2.2 Tuyaux accessoires: Diamètres

Tuyaux accessoires (mm) HP Øa Øb
Tuyauterie de gaz
▪ Connexion frontale
▪ Connexion inférieure
Tuyauterie de liquide
▪ Connexion frontale
▪ Connexion inférieure
Tuyau de gaz haute/basse pression
▪ Connexion frontale
▪ Connexion inférieure
5 25,4 19,1
8 10 22,2 12 28,6 14 16 18 20
(a)
18+20
5 9,5 9,5
8 10 12 12,7 14 12,7 16 18 15,9 20
5 19,1 15,9
8 10 19,1 12 14 22,2 16 18 20 28,6
31,8 41,4

2.4 Retrait du raidisseur de transport (uniquement pour 18+20 HP)

Les raidisseurs de transport protégeant l'unité pendant le transport doivent être ôtés. Procédez comme illustré et conformément à la procédure ci-dessous.
REMARQUE
Si l'appareil est utilisé avec le raidisseur de transport fixé, des vibrations ou un bruit anormaux peuvent se produire.
1 Desserrez légèrement le boulon (a). 2 Retirez le raidisseur de transport (b) comme illustré ci-dessous. 3 Serrez le boulon (a) de nouveau. 4 Desserrez légèrement le boulon (c). 5 Retirez le boulon (d) du raidisseur de transport (e). 6 Retirez le raidisseur de transport (e) comme indiqué dans la
figure ci-dessous.
7 Serrez le boulon (c) de nouveau.
(a) Uniquement en combinaison avec le kit d'embranchement
multiconnexion de l'unité extérieure.

2.3 Retrait du raidisseur de transport (uniquement pour 14-16 HP)

Les raidisseurs de transport protégeant l'unité pendant le transport doivent être ôtés. Procédez comme illustré et conformément à la procédure ci-dessous.
REMARQUE
Si l'appareil est utilisé avec le raidisseur de transport fixé, des vibrations ou un bruit anormaux peuvent se produire.
1 Desserrez légèrement le boulon (a). 2 Retirez le raidisseur de transport (b) comme illustré ci-dessous. 3 Serrez le boulon (a) de nouveau.
Manuel d'installation et d'utilisation
6
3 À propos des unités et des
options

3.1 A propos de l'unité extérieure

Ce manuel d'installation concerne le système de récupération de chaleur VRV IV à variateur.
Gamme de modèles:
REYQ8~20+REMQ5U7Y1B
Récupération de chaleur VRV IV+
4P546222-1 – 2018.09

4 Préparation

k
e
c
k l
e
e e
f h
b
a
k
l
c c
kkk
j
c
e
i
k
k
c
d
1
3
2
5
4
e
g
c
T
AO
(°C WB)
a b
20
15.5 15
10
5
0
–5
–10
–15
–20
10 15 20 25
27
30
T
AI
(°C DB)
Modèle Description
REYQ8~20 Modèle à récupération de chaleur pour
usage simple ou multiple
REMQ5 Modèle à récupération de chaleur pour une
utilisation multiple uniquement
En fonction du type d'unité extérieure retenu, certaines fonctionnalités seront présentes ou non. Elles vous seront rappelées tout au long de ce manuel. Certaines caractéristiques ont des droits de modèle exclusifs.
Ces unités sont destinées à une installation extérieure et à des pompes à chaleur qui incluent les applications air/air et air/eau.
Ces unités affichent des capacités de chauffage (en fonctionnement individuel) allant de 25 à 63kW et des capacités de refroidissement allant de 22,4 à 56kW. En configuration multiple, les capacités de chauffage et de refroidissement peuvent atteindre respectivement 168kW et 150kW.
L'unité extérieure est conçue pour fonctionner en mode de chauffage à des températures ambiantes comprises entre –20°CBH et 15,5°C BH et en mode de refroidissement à des températures ambiantes de –5°CBS à 43°CBS.

3.2 Configuration du système

REMARQUE
La conception du système ne doit pas se faire à des températures inférieures à –15°C.
i Kit EKEXV j AHU
k Interface utilisateur
l Interface utilisateur sans fil
4 Préparation

4.1 Préparation du lieu d'installation

4.1.1 Exigences du site d'installation pour l'unité extérieure

Prenez en compte les directives en matière d'espacement. Reportez-vous au chapitre "Caractéristiques techniques".
ATTENTION
Appareil non accessible au public: installez-le dans un endroit sûr, protégé d'un accès aisé.
Cette unité, intérieure et extérieure, peut être installée dans un environnement commercial et en industrie légère.
REMARQUE
Il s'agit d'un produit de classe A. Dans un environnement domestique, ce produit peut provoquer des interférences radio. Dans ce cas, l'utilisateur sera invité à prendre les mesures adéquates.

4.1.2 Exigences supplémentaires du site d'installation pour l'unité extérieure dans les climats froids

a Unité extérieure b Tuyauterie de réfrigérant c Unité BS d Unité BS multiple e Unité intérieure VRV DX
REYQ8~20+REMQ5U7Y1B Récupération de chaleur VRV IV+ 4P546222-1 – 2018.09
f Bloc hydrothermique LT g Unité intérieure VRV à refroidissement uniquement h Bloc hydrothermique HT
REMARQUE
Lors de l'utilisation de l'unité à une température extérieure basse et dans des conditions d'humidité élevées, veillez à prendre les précautions pour maintenir les trous de purge de l'unité libres à l'aide de l'équipement approprié.
En chauffage:
a Plage de fonctionnement en chauffage b Plage de fonctionnement
TAI Température intérieure ambiante TAO Température extérieure ambiante
Si l'unité doit fonctionner 5 jours dans cette région à forte humidité (>90%), Daikin recommande l'installation du kit de bande de chauffage en option (EKBPH012TA ou EKBPH020TA) pour garder les trous de purge libres.
Manuel d'installation et d'utilisation
7
4 Préparation
C
A
B
D E
C C
E
a
b
x
y
43
1 2

4.2 Préparation de la tuyauterie de réfrigérant

4.2.1 Exigences de la tuyauterie de réfrigérant

REMARQUE
Le réfrigérant R410A exige des précautions particulières pour conserver le système propre et sec. Les corps étrangers (notamment les huiles minérales ou l'humidité) ne doivent pas être mélangés dans le système.
REMARQUE
La tuyauterie et les autres pièces sous pression devront être conçues pour le réfrigérant. Utilisez du cuivre sans couture désoxydé à l'acide phosphorique pour le fluide de refroidissement.
▪ N'utiliser que du cuivre sans soudure désoxydé à l'acide
phosphorique.
▪ La quantité de matériaux étrangers à l'intérieur des tuyaux (y
compris les huiles de fabrication) doit être ≤ 30mg/10m.
▪ Degré de trempe: utilisez une tuyauterie avec un degré de trempe
en fonction du diamètre du tuyau indiqué dans le tableau ci­dessous.
Diamètre du tuyau Degré de trempe du matériau de la
tuyauterie
≤15,9mm O (recuit) ≥19,1mm 1/2H (demi-durci)
▪ Toutes les longueurs et distances des tuyaux ont été prises en
considération (voir A propos de la longueur de tuyau dans le guide de référence de l'installateur).

4.2.2 Pour sélectionner la taille de la tuyauterie

Déterminez la taille adéquate en vous reportant aux tableaux suivants et à la figure de référence (uniquement à titre indicatif).
Type de capacité de
l'unité extérieure
(HP)
5~8 9,5 19,1 15,9
10 9,5 22,2 19,1 12 12,7 28,6 19,1
14~16 12,7 28,6 22,2
18 15,9 28,6 22,2
20~22 15,9 28,6 28,6
24 15,9 34,9 28,6
26~34 19,1 34,9 28,6
36 19,1 41,3 28,6
38~54 19,1 41,3 34,9
Taille du diamètre extérieur de la
canalisation (mm)
Tuyauterie
de liquide
Tuyau de gaz
d'aspiration
Tuyau de gaz
haute/basse
pression
D: Canalisation entre kits de branchement de réfrigérant ou kit de branchement de réfrigérant et unité BS
Choisir dans le tableau suivant en fonction du type de capacité totale de l'unité intérieure connecté en aval. Ne pas laisser la tuyauterie de connexion dépasser la taille de la canalisation de réfrigérant choisie par le nom du modèle du système général.
Coefficient de débit de l'unité intérieure
<150 9,5 15,9 12,7 150≤x<200 19,1 15,9 200≤x<290 22,2 19,1 290≤x<420 12,7 28,6 420≤x<640 15,9 28,6 640≤x<920 19,1 34,9
≥920 41,3
Taille du diamètre extérieur de la
canalisation (mm)
Tuyauterie
de liquide
Tuyau de gaz
d'aspiration
Tuyau de gaz
haute/basse
pression
1,2 Unité intérieure VRVDX
3 Unité BS 4 Unité intérieure VRV à refroidissement uniquement
A~E Tuyauterie
a,b Kit d'embranchement intérieur x,y kit raccordement extérieur multiple
A, B, C: Canalisation entre l'unité extérieure et le (premier) kit de branchement de réfrigérant
Choisir dans le tableau suivant en fonction du type de capacité totale de l'unité extérieure connecté en aval.
Manuel d'installation et d'utilisation
8
Exemple:
▪ Capacité en aval pour E=[indice de capacité de l'unité 1] ▪ Capacité en aval pour D=[indice de capacité de l'unité 1]+[indice
de capacité de l'unité 2]
E: Canalisation entre kit d'embranchement de réfrigérant ou unité BS et unité intérieure
La taille du tuyau pour une connexion directe à une unité intérieure doit être la même que la taille de connexion de l'unité intérieure (au cas où une unité intérieure est une VRV DX intérieure ou un bloc hydrothermique).
Coefficient de débit de l'unité intérieure
15~50 12,7 6,4
63~140 15,9 9,5
200 19,1 250 22,2
▪ Si une augmentation de la tuyauterie est requise, reportez-vous
au tableau ci-dessous.
Taille du diamètre extérieur de la
canalisation (mm)
Tuyauterie de gaz Tuyauterie de
liquide
REYQ8~20+REMQ5U7Y1B
Récupération de chaleur VRV IV+
4P546222-1 – 2018.09
4 Préparation
a
e
b
c
d
a b
b
a b
a
a
b
a b
b
a
a
▪ Pour les raccords refnet autres que le premier embranchement
(raccord refnet b en exemple), sélectionnez le modèle de kit d'embranchement approprié en fonction du coefficient de capacité total de toutes les unités intérieures raccordées après l'embranchement de réfrigérant.
a Unité extérieure b Tuyaux principaux c Augmentation d Premier kit d'embranchement de réfrigérant e Unité intérieure
Taille augmentée
Classe HP Taille du diamètre extérieur de la
tuyauterie de liquide (mm)
5~8 9,5 12,7
10
12+14 12,7 15,9
16
18~22 15,9 19,1
24
26~34 19,1 22,2 36~54
▪ L'épaisseur du tuyau de réfrigérant doit être conforme à la
législation en vigueur. L'épaisseur minimale du tuyau R410A doit être conforme au tableau ci-dessous.
Ø des tuyaux (mm) Epaisseur minimale t (mm)
6,4/9,5/12,7 0,80
15,9 0,99
19,1/22,2 0,80
28,6 0,99 34,9 1,21 41,3 1,43
▪ Si les tailles de tuyaux requises (en pouces) ne sont pas
disponibles, il est également possible d'utiliser d'autres diamètres (en millimètres) en prenant soin:
▪ Sélectionnez la taille de tuyau la plus proche de la taille
requise.
▪ Utilisez les adaptateurs appropriés pour passer d'une unité de
mesure à l'autre (non fournis).
▪ Le calcul du réfrigérant supplémentaire doit être ajusté comme
mentionné dans "5.6.3 Détermination de la quantité de
réfrigérant complémentaire"à la page17.

4.2.3 Pour sélectionner les kits d'embranchement de réfrigérant

Réfrigérant refnets
Pour l'exemple de tuyau, se reporter à "4.2.2Pour sélectionner la
taille de la tuyauterie"à la page8.
▪ Lors de l'utilisation des raccords refnet au premier
embranchement compté à partir du côté unité extérieure, choisir dans le tableau suivant en fonction de la capacité de l'unité extérieure (exemple: raccord refnet a).
Coefficient de débit de l'unité
3 tuyaux
intérieure
<200 KHRQ23M20T 200≤x<290 KHRQ23M29T9 290≤x<640 KHRQ23M64T
≥640 KHRQ23M75T
▪ En ce qui concerne les collecteurs refnet, choisissez dans le
tableau suivant en fonction de la capacité totale de toutes les unités intérieures raccordées sous le collecteur refnet.
Coefficient de débit de l'unité
3 tuyaux
intérieure
<200 KHRQ23M29H 200≤x<290 290≤x<640 KHRQ23M64H
(a)
≥640 KHRQ23M75H
(a) Si la taille du tuyau au-dessus du collecteur refnet fait
Ø34,9 ou plus, le KHRQ23M75H est nécessaire.
INFORMATIONS
Un maximum de 8 embranchements peut être raccordé à un collecteur.
▪ Comment choisir un kit de raccordement multiple extérieur?
Choisissez dans le tableau suivant en fonction du nombre d'unités extérieures.
Nombre d'unités extérieures Nom du kit d'embranchement
2 BHFQ23P907 3 BHFQ23P1357
INFORMATIONS
Les réducteurs ou raccords en T sont fournis en option.
REMARQUE
Les kits d'embranchement de réfrigérant peuvent uniquement être utilisés avec le R410A.

4.2.4 Unités extérieures multiples: Configurations possibles

▪ La conduite entre les unités extérieures doit être acheminée de
niveau ou légèrement vers le haut pour éviter tout risque de rétention d'huile dans la tuyauterie.
Schéma 1
Schéma 2
Type de capacité de l'unité
3 tuyaux
extérieure (HP)
8+10 KHRQ23M29T9 12~22 KHRQ23M64T 24~54 KHRQ23M75T
a Vers l'unité intérieure b Canalisation entre unités extérieures
X Non permis (huile restant dans la tuyauterie)
REYQ8~20+REMQ5U7Y1B Récupération de chaleur VRV IV+ 4P546222-1 – 2018.09
Manuel d'installation et d'utilisation
9
4 Préparation
a
b b b
a
b b b
a
b
a
b
a
b
a
a
a
≥200 mm
a
b
≤2 m
a
≤2 m ≤2 m
≥200 mm
≥200 mm
b
>2 m >2 m
A B C
a b c
O Autorisé
▪ Pour éviter tout risque de rétention d'huile au niveau de la
dernière unité extérieure, toujours raccorder la vanne d'arrêt et la canalisation entre les unités extérieures comme le montrent les 4 possibilités correctes de l'illustration ci-dessous.
a Vers l'unité intérieure
b L'huile s'accumule dans la dernière unité extérieure lorsque
le système s'arrête
X Non permis O Autorisé
▪ Si la longueur du tuyau entre les unités extérieures dépasse 2m,
créer une pente de 200 mm minimum dans la conduite de gaz d’aspiration et la conduite de gaz basse/haute pression sur une longueur de 2m à partir du kit.
Si Alors
≤2m
>2m
REMARQUE
Il y a des limitations dans l'ordre des connexions des tuyaux de réfrigérant entre les unités extérieures pendant l'installation en cas de système à plusieurs unités extérieures. Effectuez l'installation en tenant compte des restrictions suivantes. Les capacités des unités extérieures A, B et C doivent répondre aux conditions de restriction suivantes: A≥B≥C.
a Vers les unités intérieures b Kit de tuyauterie à connexion multiple d'unité extérieure
(premier branchement) c Kit de tuyauterie à connexion multiple d'unité extérieure
(second branchement)

4.3 Préparation du câblage électrique

4.3.1 A propos de la conformité électrique

Cet équipement est conforme à: ▪ EN/IEC 61000‑3‑11 pour autant que l’impédance du système Z
soit inférieure ou égale à Z l’alimentation de l’utilisateur et le réseau public.
▪ EN/IEC 61000‑3‑11 = Norme technique européenne/
internationale fixant les limites de variation de tension, de fluctuation de tension et d’oscillation dans les systèmes d’alimentation basse tension publics pour équipements avec courant nominal de ≤75A.
▪ L’installateur ou l’utilisateur de l’équipement a la responsabilité
– éventuellement en consultant l’opérateur du réseau de distribution – de veiller à ce que l’équipement soit uniquement raccordé à l’alimentation avec une impédance du système Z inférieure ou égale à Z
max
EN/IEC 61000‑3‑12 pour autant que l’impédance de court-circuit
Ssc soit supérieure ou égale à la valeur Ssc minimale au point d’interface entre l’alimentation de l’utilisateur et le réseau public.
▪ EN/IEC 61000‑3‑12 = Norme technique européenne/
internationale fixant les limites des courants harmoniques produits par l’équipement raccordé aux systèmes basse tension publics avec une entrée de courant de >16 A et ≤75 A par phase.
▪ L’installateur ou l’utilisateur de l’équipement a la responsabilité
– éventuellement en consultant l’opérateur du réseau de distribution – de veiller à ce que l’équipement soit uniquement raccordé à l’alimentation avec un courant de court-circuit S supérieur ou égal à la valeur minimale Ssc.
au point d’interface entre
max
.
sys
sys
sc
Manuel d'installation et d'utilisation
10
a Vers l'unité intérieure
b Canalisation entre unités extérieures
Unité extérieure simple
Modèle Z
(Ω) Valeur S
max
minimale (kVA)
REMQ5 2893 REYQ8 2893 REYQ10 3954 REYQ12 4313 REYQ14 4852 REYQ16 5391 REYQ18 6289 REYQ20 7009
REYQ8~20+REMQ5U7Y1B
Récupération de chaleur VRV IV+
4P546222-1 – 2018.09
sc

5 Installation

14×14×
5~12 HP 14~20 HP
Unités extérieures multiples
Modèle Z
REYQ10 5786 REYQ13 5786 REYQ16 5786 REYQ18 6846 REYQ20 7206 REYQ22 8266 REYQ24 8284 REYQ26 9165 REYQ28 9704 REYQ30 10602 REYQ32 10781 REYQ34 11680 REYQ36 12399 REYQ38 13495 REYQ40 14556 REYQ42 14735 REYQ44 15094 REYQ46 15634 REYQ48 16172 REYQ50 17071 REYQ52 17969 REYQ54 18868
INFORMATIONS
Les unités multiples sont des combinaisons standard.
(Ω) Valeur S
max
minimale (kVA)
sc

4.3.2 Exigences du dispositif de sécurité

L'alimentation électrique doit être protégée avec les dispositifs de sécurité requis, c'est-à-dire un commutateur principal, un fusible à fusion lente sur chaque phase et un disjoncteur de fuite à la terre conformément à la législation en vigueur.
Pour les combinaisons standard
La sélection et le dimensionnement du câblage doit se faire conformément à la législation en vigueur sur la base des informations mentionnées dans le tableau ci-dessous.
Pour les combinaisons non standard
Calculez la capacité de fusible recommandée.
Formule Effectuez le calcul en ajoutant l'ampérage de circuit
minimum de chaque unité utilisée (en fonction du tableau ci-dessus), multipliez le résultat par 1.1 et sélectionnez la capacité de fusible recommandée directement supérieure.
Exemple Combinaison le REYQ30 avec les REYQ8, REYQ10 et
REYQ12. ▪ Ampérage minimum du circuit de REYQ8=16,1A ▪ Ampérage minimum du circuit de REYQ10=22,0A ▪ Ampérage minimum du circuit de REYQ12=24,0A En conséquence, l'ampérage minimum du circuit du
REYQ30=16,1+22,0+24,0=62,1A En multipliant le résultat ci-dessus par 1,1
(62,1A×1,1)=68,3A; par conséquent, la capacité de fusible recommandée serait de 80A.
REMARQUE
Lors de l'utilisation d'un disjoncteur actionné par courant résiduel, veillez à utiliser un courant résiduel nominal de 300 mA de type haute vitesse.
5 Installation

5.1 Ouverture des unités

5.1.1 Pour ouvrir l'unité extérieure

DANGER: RISQUE D'ÉLECTROCUTION
DANGER: RISQUE DE BRÛLURE
Pour accéder à l'unité, les plaques avant doit être ouvertes comme suit:
Modèle Ampérage
REMQ5 16,1A 20A REYQ8 16,1A 20A REYQ10 22,0A 25A REYQ12 24,0A 32A REYQ14 27,0A 32A REYQ16 31,0A 40A REYQ18 35,0A 40A REYQ20 39,0A 50A
Pour tous les modèles: ▪ Phase et fréquence: 3N~50Hz ▪ Tension: 380~415V ▪ Section de câble de transmission: 0,75~1,25 mm2, la longueur
maximale est de 1000 m. Si le câblage de transmission total dépasse ces limites, il peut entraîner une erreur de communication.
REYQ8~20+REMQ5U7Y1B Récupération de chaleur VRV IV+ 4P546222-1 – 2018.09
Unité extérieure simple
de circuit
minimal
Fusibles
recommandés
Une fois que les plaques avant sont ouvertes, il est possible d'accéder à la boîte des composants électriques. Reportez-vous à
"5.1.2 Pour ouvrir la boîte des composants électrique de l'unité extérieure"à la page12.
Les boutons poussoirs sur la carte de circuits imprimés principale doit être accessible à des fins d'entretien. Pour accéder à ces boutons poussoirs, le couvercle du boîtier des composants électriques ne doit pas être ouvert. Reportez-vous à "6.1.3 Accès
aux composants du réglage sur place"à la page26.
Manuel d'installation et d'utilisation
11
5 Installation
5~12 HP
SW8
14~20 HP
SW8
a b
c d
e
≥100 mm
≥100 mm
*
729
≤613
≥929
AB
AA
a
(mm)
20 mm
a

5.1.2 Pour ouvrir la boîte des composants électrique de l'unité extérieure

REMARQUE
N'exercez PAS de force excessive lors de l'ouverture du couvercle du boîtier des composants électroniques. Une force excessive peut déformer le couvercle, ce qui peut entraîner la pénétration d'eau et la dégradation de l'équipement.
X Non permis
O Permis (* = installation préférée)
▪ La hauteur des fondations doit être au moins de 150mm du sol.
Dans les régions exposées à de fortes chutes de neige, cette hauteur doit être augmentée en fonction du lieu d'installation et des conditions.
▪ L'installation préférée est sur des fondations longitudinales solides
(cadre avec poutres d'acier ou béton). Les fondations doivent être plus grandes que la zone marquée en gris.
REMARQUE
Lors de la fermeture du couvercle du boîtier des composants électriques, assurez-vous que le matériau d'étanchéité du côté inférieur arrière du couvercle n'est pas coincé et plié vers l'intérieur.
a Couvercle de la boîte des composants électriques b Côté avant c Bornier d'alimentation d Matériau d'étanchéité e De l'humidité et de la saleté pourraient entrer X Non permis O Permis

5.2 Montage de l'unité extérieure

Fondations minimales
a Point d'ancrage (4×)
HP AA AB
5~12 766 992
14~20 1076 1302
▪ Fixez l'unité en place au moyen de quatre boulons pour fondation
M12. Il vaut mieux visser les boulons de fondation jusqu'à ce que leur longueur reste à 20mm de la surface de la fondation.
REMARQUE
▪ Préparez un canal pour l'écoulement de l'eau autour de
la fondation afin d'évacuer les eaux usées du pourtour de l'appareil. Pendant le fonctionnement du chauffage et lorsque les températures extérieures sont négatives, l'eau évacuée de l'unité extérieure gèlera. Si l'évacuation d'eau n'est pas surveillée, la zone autour de l'unité pourrait être très glissante.
▪ Lorsque l'unité est installée dans un environnement
corrosif, utilisez un écrou avec une rondelle plastique (a) pour protéger la partie serrante de l'écrou de la rouille.

5.2.1 Prévoir la structure d'installation

Assurez-vous que l'unité est installée de niveau sur une base suffisamment forte pour empêcher des vibrations et des bruits.
REMARQUE
▪ Lorsque la hauteur d'installation de l'unité doit être
augmentée, n'utilisez PAS de supports pour soutenir uniquement les coins.
▪ Les pieds sous l'appareil doivent avoir une largeur
minimale de 100mm.
Manuel d'installation et d'utilisation
12
REYQ8~20+REMQ5U7Y1B
Récupération de chaleur VRV IV+
4P546222-1 – 2018.09
5 Installation
a b
c
c
b
a
a
a
A B
7.5°
7.5°
>120 mm
>500 mm

5.3 Raccordement de la tuyauterie de réfrigérant

5.3.1 Acheminement de la tuyauterie de réfrigérant

L'installation du tuyau de réfrigérant est possible comme connexion avant ou connexion latérale (vue du bas) comme le montre l'illustration ci-dessous.
a Connexion côté gauche b Connexion frontale c Connexion côté droit
Pour les connexions latérales, le trou à défoncer sur la plaque inférieure doit être ôté:

5.3.3 Raccordement du kit de tuyauterie à connexions multiples

REMARQUE
Une mauvaise installation peut entraîner un dysfonctionnement de l'unité extérieure.
▪ Installez les joints horizontalement de sorte que l'étiquette de mise
en garde (a) fixée au joint soit sur le dessus. ▪ N'inclinez pas le joint de plus de 7,5° (voir vue A). ▪ N'installez pas le joint verticalement (voir vue B).
a Etiquette de mise en garde X Non permis O Autorisé
▪ Assurez-vous que la longueur totale du tuyau connecté au joint
est absolument droite sur plus de 500 mm. Il n'y a que si une tuyauterie locale droite de plus de 120mm est raccordée qu'une section droite de plus de 500mm pourra être garantie.
5.3.2 Raccordement du tuyau de réfrigérant à
Branchez les vannes d'arrêt à la tuyauterie non fournie à l'aide de tuyaux accessoires fournis avec l'unité.
Les connexions vers les kits de branchement relèvent de la responsabilité de l'installateur (tuyauterie sur place).
REYQ8~20+REMQ5U7Y1B Récupération de chaleur VRV IV+ 4P546222-1 – 2018.09
a Gros trou à enfoncer b Forer c Points de forage
REMARQUE
Précautions lors de la réalisation des trous à défoncer:
▪ Evitez d'endommager le boîtier. ▪ Après avoir réalisé les trous à défoncer, nous vous
recommandons d'éliminer les bavures et de peindre les bords et les zones autour des bords à l'aide de la peinture de réparation pour éviter la formation de rouille.
▪ Lors du passage du câblage électrique à travers les
trous à enfoncer, entourer le câble de bande de protection pour éviter tout dégât.
l'unité extérieure
REMARQUE
▪ Veillez à utiliser les tuyaux accessoires fournis lorsque
vous effectuez des travaux de tuyauterie sur place.
▪ Veillez à ce que la canalisation installée sur place ne
touche pas d'autres canalisations, le panneau inférieur ou le panneau latéral. Veillez, tout particulièrement pour la connexion inférieure et latérale, à protéger la canalisation au moyen d'une isolation adéquate pour éviter qu'elle entre en contact avec le boîtier.

5.3.4 Unités extérieures multiples: Trous à enfoncer

Connexion Description
Connexion frontale Retirer les trous à défoncer de la plaque
avant pour connecter.
Connexion inférieure Retirer les trous à enfoncer sur le bâti du bas
et acheminer la tuyauterie sous le bas.

5.3.5 Pour protéger de tout encrassement

Obturez les tuyaux et trous de passage des fils à l'aide de matériau d'étanchéité (non fourni), sinon la capacité de l'unité baissera et de petits animaux pourraient entrer dans la machine.
Manuel d'installation et d'utilisation
13
5 Installation
p<p
>
R410AN2
b c e
a
f
g h
d
A
C D
B

5.3.6 Utilisation de la vanne d'arrêt et de l'orifice de service

Manipulation de la vanne d'arrêt
▪ Veillez à maintenir les vannes d'arrêt ouvertes pendant le
fonctionnement.
▪ Les vannes d'arrêt de gaz et de liquide sont fermées d'usine.
Ouverture/fermeture de la vanne d'arrêt
1 Retirez le capuchon pare-poussière. 2 Insérez une clé hexagonale (côté liquide: 4 mm, côté gaz:
8mm) dans la vanne d’arrêt et tournez la vanne d’arrêt:
Dans le sens inverse des aiguilles d'une montre pour ouvrir.
Dans le sens des aiguilles d'une montre pour fermer.
3 Serrez fermement la vanne d'arrêt lors de l'ouverture ou de la
fermeture de la vanne d'arrêt. Pour connaître le couple de serrage correct, reportez-vous au tableau ci-dessous.
REMARQUE
Un couple inadéquat peut provoquer une fuite de réfrigérant et une rupture de la vanne d'arrêt.
4 Remettez le capuchon pare-poussière.
Résultat: La vanne est alors ouverte/fermée.
Manipulation de l'orifice de service
▪ Utilisez toujours un tuyau de charge équipé d'une broche
d'enfoncement de vanne étant donné que l'orifice de service est une vanne de type Schrader.
▪ Après avoir manipulé l'orifice de service, veiller à serrer le
couvercle d'orifice de service fermement. Pour connaître le couple de serrage, reportez-vous au tableau ci-dessous.
▪ Une fois le couvercle d’orifice de service resserré, s’assurer qu'il
n'existe aucune fuite de réfrigérant.
1 Assurez-vous que les vannes d'arrêt sont entièrement fermées.
2 Raccordez l'unité de dépression/récupération à l'orifice de
service de toutes les vannes d'arrêt via un collecteur.
a Vanne de réduction de pression
b Azote
c Bascule
d Réservoir de réfrigérant R410A (système à siphon)
e Pompe à vide
f Vanne d'arrêt de la conduite de liquide g Vanne d'arrêt de la conduite de gaz h Vanne d'arrêt du conduite de gaz haute/basse pression
A Vanne A B Vanne B C Vanne C D Vanne D
3 Récupérer le gaz et l'huile de la tuyauterie écrasée à l'aide de
l'unité de récupération.
ATTENTION
Ne laissez pas les gaz s'échapper dans l'atmosphère.
4 Lorsque le gaz et l'huile sont complètement collectés de la
tuyauterie écrasée, débrancher le flexible de charge et fermer les orifices de service.
5 Coupez la partie inférieure des tuyaux de la vanne d'arrêt de
liquide, de gaz et de gaz haute/basse pression le long de la ligne noire. Utilisez un outil approprié (par ex. un coupe-tube).
Couples de serrage
Dimension
de la vanne
d'arrêt (mm)
Ø12,7 8~10N•m Ø15,9 14~16N•m 6mm Ø19,1 19~21N•m 8mm Ø25,4

5.3.7 Retirer les tuyaux écrasés

Utilisez la procédure suivante pour retirer le tuyau écrasé:
Manuel d'installation et d'utilisation
14
Couple de serrage (à l'ouverture ou à la
fermeture)
Corps de vanne Clé hexagonale Orifice de
service
Ø9,5 5~7N•m 4mm 10,7~14,7
AVERTISSEMENT
Tout gaz ou huile restant à l'intérieur de la vanne d'arrêt peut faire exploser la tuyauterie écrasée.
Le non-respect des instructions de la procédure ci-dessous peut entraîner des dommages aux biens ou des blessures qui peuvent être graves en fonction des circonstances.
AVERTISSEMENT
N'enlevez jamais le tuyau écrasé par brasage. Tout gaz ou huile restant à l'intérieur de la vanne d'arrêt
peut faire exploser la tuyauterie écrasée.
6 Attendez que toute l'huile se soit écoulée avant de poursuivre la
connexion de la tuyauterie sur place au cas où la récupération n'était pas achevée.
REYQ8~20+REMQ5U7Y1B
Récupération de chaleur VRV IV+
4P546222-1 – 2018.09
5 Installation
Les tuyauteries de réfrigérant sont terminées?
Les unités intérieures et/ou extérieures étaient déjà sous tension?
Utilisez la procédure: "Méthode 2: après la mise
sous tension".
Achevez la tuyauterie.
Utilisez la procédure: "Méthode 1: avant la mise
sous tension (méthode normale)".
Oui
Non
Non
Oui
p<p
>
R410AN2
C D
b c e
a
g
h
f
d
A B

5.4 Vérification de la tuyauterie de réfrigérant

5.4.1 A propos du contrôle de la tuyauterie de réfrigérant

Il est très important que toute la tuyauterie de réfrigérant soit réalisée avant que les unités (extérieure ou intérieure) soient mises en service.
Lorsque les unités seront mises sous tension, les vannes d'expansion s'activeront. Cela veut dire qu'elles se fermeront. Le test de fuite et le séchage à dépression du tuyau non fourni et des unités intérieures sont impossibles lorsque cela se produit.
Par conséquent, 2 méthodes seront expliquées pour l'installation initiale, le test de fuite et le séchage à dépression.
Méthode 1: Avant la mise sous tension
Si le système n'a pas encore été mis sous tension, aucune action spéciale n'est requise pour effectuer le test de fuite et le séchage par le vide.
Méthode 2: Après la mise sous tension
Si le système a déjà été mis sous tension, activer le réglage [2‑21] (se reporter à "6.1.4 Accès au mode 1 ou 2" à la page 26). Ce réglage ouvrira les vannes d'expansion non fournies pour garantir une voie à la tuyauterie de R410A et permettre d'effectuer le test de fuite et le séchage par le vide.
Seule la tuyauterie de réfrigérant installée en option doit être vérifiée. Par conséquent, assurez-vous que les vannes d’arrêt des unités extérieures sont bien fermées avant d’effectuer le test de fuite ou le séchage à vide.
REMARQUE
Assurez-vous que toutes les vannes de tuyaux (non fournies) installées sont OUVERTES (pas les vannes d'arrêt des unités extérieures) avant de commencer le test de fuite et le séchage à vide.
Pour plus d'informations sur l'état des vannes, se reporter à
"5.4.3Contrôle du tuyau de réfrigérant: Configuration"à la page15.

5.4.2 Contrôle du tuyau de réfrigérant: Directives générales

Branchez la pompe à vide via un collecteur à l'orifice d'entretien de toutes les vannes d'arrêt pour augmenter l'efficacité (se reporter à
"5.4.3 Contrôle du tuyau de réfrigérant: Configuration" à la page15).
REMARQUE
Utilisez une pompe à vide à 2 étages munie d'un clapet de non-retour ou d'une électrovanne dont le débit d'évacuation est de –⁠100,7 kPa (−⁠1,007 bar)(5 Torr absolus).
REMARQUE
Assurez-vous que l'huile de la pompe n'est pas refoulée vers le système lorsque la pompe est à l'arrêt.
REMARQUE
Ne purgez pas l'air avec les réfrigérants. Utilisez une pompe à vide pour purger l'installation.

5.4.3 Contrôle du tuyau de réfrigérant: Configuration

REMARQUE
Assurez-vous que toutes les unités intérieures raccordées à l'unité extérieure sont sous tension.
REMARQUE
Attendez que l'unité extérieure ait terminé l'initialisation pour appliquer le réglage [2‑21].
Test d'étanchéité et séchage à vide
Le contrôle de la tuyauterie de réfrigérant implique de: ▪ Vérifier s'il y a des fuites dans la tuyauterie de réfrigérant. ▪ Effectuer le séchage par le vide pour éliminer toute humidité, l'air
ou l'azote dans le tuyau de réfrigérant.
S’il y a un risque de présence d’humidité dans la tuyauterie de réfrigérant (par exemple, de l’eau peut avoir pénétré dans le tuyau), appliquez d’abord la procédure de séchage à vide ci-dessous jusqu’à ce que toute l’humidité ait disparu.
Tous les tuyaux à l’intérieur de l’unité ont été testés en usine pour s’assurer qu’il n’y a pas de fuite.
REYQ8~20+REMQ5U7Y1B Récupération de chaleur VRV IV+ 4P546222-1 – 2018.09
a Vanne de réduction de pression b Azote c Bascule d Réservoir de réfrigérant R410A (système à siphon) e Pompe à vide
f Vanne d'arrêt de la conduite de liquide g Vanne d'arrêt de la conduite de gaz h Vanne d'arrêt du conduite de gaz haute/basse pression
A Vanne A B Vanne B C Vanne C D Vanne D
Vanne Etat de la vanne
Vanne A Ouvert Vanne B Ouvert Vanne C Ouvert Vanne D Ouvert Vanne d'arrêt de la conduite de
Fermer
liquide Vanne d'arrêt de la conduite de
Fermer
gaz Vanne d'arrêt du conduite de gaz
Fermer
haute/basse pression
Manuel d'installation et d'utilisation
15
5 Installation
a
b
REMARQUE
Les connexions aux unités intérieures et à toutes les unités intérieures doivent également être testées (fuite et vide). Laissez les éventuelles vannes de tuyau (non fournies) installées ouvertes également.
Reportez-vous au manuel d'installation de l'unité intérieure pour plus de détails. Le test de fuite et le séchage à vide doivent se faire avant de mettre l'unité sous tension. Sinon, reportez-vous aussi à l'organigramme décrit plus haut dans ce chapitre (voir "5.4.1 A propos du contrôle de la
tuyauterie de réfrigérant"à la page15).

5.4.4 Réalisation d'un essai de fuite

Le test de fuite doit satisfaire aux spécifications EN378‑2.
Recherche de fuites: Test de fuite de dépression
1 Vidangez le système par le tuyau de liquide et de gaz à –⁠100,7
kPa (–⁠1,007bar) (5Torr absolus) pendant plus de 2 heures.
2 Une fois atteint, arrêtez la pompe à vide et vérifiez que la
pression ne monte pas pendant au moins 1 minute.
3 Si la pression monte, le système peut soit contenir de l'humidité
(voir séchage à vide ci-dessous) ou présenter des fuites.
Recherche de fuites: Test de fuite de pression
1 Rompez la dépression en pressurisant à l’azote jusqu’à une
pression minimale de 0,2 MPa (2bars). Ne réglez jamais la pression de jauge au-delà de la pression de fonctionnement maximale de l’unité, c.-à-d. 4,0MPa (40bar).
2 Testez la présence de fuites en appliquant une solution de
détection de bulles sur tous les raccords de tuyauterie.
3 Éliminez tout l'azote.

5.5 Isolation de la tuyauterie de réfrigérant

Après avoir terminé le test de fuite et le séchage par le vide, la tuyauterie doit être isolée. Tenez compte des points suivants:
▪ Veillez à isoler entièrement le tuyau de raccordement et les kits de
branchement de réfrigérant.
▪ Veillez à isoler les tuyaux de liquide et de gaz (de toutes les
unités).
▪ Utilisez de la mousse de polyéthylène résistant à une température
de 70°C pour les canalisations de liquide et de la mousse de polyéthylène résistant à une température de 120°C pour les canalisations de gaz.
▪ Renforcer l'isolation du tuyau de réfrigérant en fonction de
l'environnement d'installation.
Température
ambiante
≤30°C 75% à 80% de HR 15mm >30°C ≥80% de HR 20mm
De la condensation peut se former sur la surface de l'isolation. ▪ S'il y a une possibilité que de la condensation de la vanne d'arrêt
pourrait s'écouler dans l'unité intérieure par les interstices dans l'isolation et les tuyauteries parce que l'unité extérieure est située plus haut que l'unité intérieure, il convient de prévenir ce problème en étanchéifiant les connexions. Voir la figure ci-dessous.
Humidité Epaisseur minimum
REMARQUE
Veillez à utiliser une solution de détection de bulles recommandée par le revendeur. N'utilisez pas d'eau savonneuse qui risque de provoquer des fissures des écrous évasés (l'eau savonneuse peut contenir du sel qui absorbe l'humidité qui se mettra à geler lorsque le tuyau refroidit) et/ou d'entraîner la corrosion des raccords évasés (l'eau savonneuse peut contenir de l'ammoniaque qui provoque un effet corrosif entre l'écrou évasé en laiton et l'évasement en cuivre).

5.4.5 Réalisation du séchage par le vide

Pour éliminer toute l’humidité du système, procédez comme suit:
1 Vidangez le système pendant au moins 2 heures jusqu'à
l'obtention d'une dépression cible de –⁠100,7kPa (–⁠1,007bar) (5Torr absolus).
2 Vérifiez que la dépression cible est maintenue pendant au
moins 1 heure lorsque la pompe à dépression est éteinte.
3 Si la dépression cible n'est pas atteinte dans les 2 heures ou
maintenue pendant 1 heure, le système peut contenir trop d'humidité. Dans ce cas, rompez la dépression en pressurisant à l'azote jusqu'à une pression de 0,05MPa (0,5bar) et répéter les étapes 1 à 3 jusqu'à ce que l'humidité ait été éliminée.
4 Selon qu'il faut charger le réfrigérant directement par l'orifice de
charge de réfrigérant ou d'abord précharger une partie du réfrigérant par la conduite liquide, ouvrir les vannes d'arrêt de l'unité extérieure ou les maintenir fermées. Voir "5.6.2A propos
de la recharge du réfrigérant" à la page 17 pour de plus
amples informations.
a Matériau d'isolation
b Matage, etc.

5.6 Charge du réfrigérant

5.6.1 Précautions lors de la recharge de réfrigérant

AVERTISSEMENT
▪ Utilisez uniquement du réfrigérant R410A. D'autres
substances peuvent entraîner des explosions et des accidents.
▪ Le R410A contient des gaz à effet de serre fluorés.
Son potentiel de réchauffement global (GWP) est de 2087,5. NE laissez PAS ces gaz s'échapper dans l'atmosphère.
▪ Lorsque vous chargez du réfrigérant, utilisez toujours
des gants de protection et des lunettes de sécurité.
REMARQUE
Si l'alimentation de certaines unités est coupée, la procédure de recharge ne peut pas s'achever correctement.
REMARQUE
Dans le cas d'un système extérieur multiple, mettre toutes les unités extérieures sous tension.
Manuel d'installation et d'utilisation
16
REYQ8~20+REMQ5U7Y1B
Récupération de chaleur VRV IV+
4P546222-1 – 2018.09
Loading...
+ 36 hidden pages