Daikin FWT02BATNMV1, FWT03BATNMV1, FWT04BATNMV1, FWT05BATNMV1, FWT06BATNMV1 Installation manual

INSTALLATION MANUAL
Models FWT02BATNMV1 FWT03BATNMV1 FWT04BATNMV1
Installation manual
Chilled Water Fan Coil Units
English
FWT05BATNMV1 FWT06BATNMV1
IM-WMGW-1205(1)-DAIKIN PART NO.: R08019029236A
Indoor Unit
OUTLINE AND DIMENSIONS
A
TOP VIEW
C
B
FRONT VIEW SIDE VIEW
English
Original Instruction
I
INSTALLATION PLATE
FDG
H
E
K
L
SEE DETAIL A
I
MJ
WATER OUTLET
WATER INLET
ON
DETAIL A
All dimensions are in mm/(in)
Dimension A B C D E F G H I J K L M N O FWT02BATNMV1 799 260 198 379 246 185 124 8 56 50 350 379 50 128 132
(31.5) (10.2) (7.8) (15.0) (9.7) (7.3) (4.9) (0.3) (2.2) (2.0) (13.8) (15.0) (2.0) (5.1) (5.2)
FWT03BATNMV1/ 899 260 198 590 246 185 124 8 56 50 435 495 50 128 132 FWT04BATNMV1 (35.4) (10.2) (7.8) (23.2) (9.7) (7.3) (4.9) (0.3) (2.2) (2.0) (17.1) (19.5) (2.0) (5.1) (5.2)
1
Indoor Unit
A
TOP VIEW
B
FRONT VIEW
CENTER LINE
I
J
INSTALLATION PLATE
A
F
H
DG
M
I
C
SIDE VIEW
WATER OUTLET
WATER INLET
ON
E
B
INSTALLATION PLATE
K
L
SEE DETAIL A
All dimensions are in mm/(in)
DETAIL A
Dimension A B C D E F G H I J K L M N O FWT05BATNMV1/ 1060 310 220 912 294 99 51 8 48 43 369 453 160 138 160
FWT06BATNMV1 (41.7) (12.2) (8.6) (35.9) (11.6) (3.9) (2.0) (0.3) (1.9) (1.7) (14.5) (17.8) (6.3) (5.4) (6.3)
2
INSTALLATION MANUAL
This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit. Special adjustment may be necessary to suit local requirements. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
SAFETY PRECAUTIONS
English
! WARNING
• Installation and maintenance should be performed by qualified persons who are familiar with local code and regulation, and experienced with this type of appliance.
• All field wiring must be installed in accordance with the national wiring regulation.
• Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.
• The unit must be GROUNDED to prevent possible hazard due to insulation failure.
• All electrical wiring must not touch the water piping or any moving parts of the fan motors.
• Confirm that the unit has been switched OFF before installing or servicing the unit.
• Risk of electric shock, can cause injury or death. Disconnect all remain electric power supplies before servicing.
• DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result in the fire hazards.
• Keep the indoor and outdoor units, power cable and transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static. (Depending on the type and source of the electrical waves, static may be heard even when more than 1m away).
! CAUTION
Please take note of the following important points when installing.
• Ensure that the drainage piping is connected properly.
If the drainage piping is not connected properly, it may cause water leakage which will dampen the furniture.
• Ensure that the unit’s panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
• Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places.
• Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF” position to prevent the nuisance tripping of the unit. If this is
not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user.
• Do not operate any heating apparatus too close to the air conditioner unit. This may cause the plastic
panel to melt or deform as a result of the excessive heat.
• Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively.
• IMPORTANT: DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM.
• Avoid direct contact of any coil treatment cleaners on plastic part. This may cause plastic part to deform as a result of chemical reaction.
NOTICE
Disposal requirements
Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste.
Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation.
Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information.
Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.
3
Loading...
+ 9 hidden pages