Daikin ERQ100A7V1B, ERQ125A7V1B, ERQ140A7V1B Operation manuals

OPERATION MANUAL
Inverter condensing unit
ERQ100A7V1B ERQ125A7V1B ERQ140A7V1B
ERQ125A7W1B ERQ200A7W1B ERQ250A7W1B
1 2
1563
2
7
12
9
4
8
1 2
3 4
13
1563
2
7
10
9
5
1411
8
12 34
1
2
1
2
3
6 7 8
1
1
6
4
1
1
7
UNIT NO.
5
1
8
NOTES
ERQ100A7V1B ERQ125A7W1B ERQ125A7V1B ERQ200A7W1B ERQ140A7V1B ERQ250A7W1B
Inverter condensing unit
Operation manual
ONTENTS
C
1. Safety cautions ..........................................................................1
2. Important information regarding the refrigerant used ................2
3. What to do before operation ......................................................2
4. Remote controller.......................................................................3
5. Changeover switch: Name and function of each switch............. 3
6. Operation range.........................................................................3
7. Operation procedure..................................................................3
7.1. Cooling, heating, and fan only operation...................................... 3
8. Energy saving and optimum operation ......................................4
9. Maintenance ..............................................................................4
9.1. Maintenance after a long stop period........................................... 4
9.2. Maintenance before a long stop period........................................ 4
10. Following symptoms are not air conditioner troubles................. 4
11. Troubleshooting..........................................................................5
12. After-sales service and warranty................................................6
12.1. After-sales service ....................................................................... 6
12.2. Shortening of "maintenance cycle" and "replacement cycle"
needs to be considered in following situations............................. 6
Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file it away for future reference.
The English text is the original instruction. Other languages are translations of the original instructions.
1. S
Read the following cautions carefully and use your equipment properly.
Keep these warning sheets handy so that you can refer to them if needed.
Also, if this equipment is transferred to a new user, make sure to hand over this user’s manual to the new user.
AFETY
WARNING
Improper handling can lead to such serious consequences as death, severe injury or damage to the equipment.
NOTE
CAUTIONS
These instructions will ensure proper use of the equipment.
Be sure to follow these important safety cautions.
age
P
Warnings
It is not good for your health to expose your body to the air flow for a long time.
In order to avoid electric shock, fire or injury, or if you detect any abnormality such as smell of fire, turn off the power supply and call your dealer for instructions.
Ask your dealer for installation of the air conditioner. Incomplete installation performed by yourself may result in a water leakage, electric shock, and fire.
Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunctions, smoke or fire when making contact with electrical parts.
Ask your dealer for improvement, repair, and maintenance. Incomplete improvement, repair, and maintenance may result in a water leakage, electric shock and fire.
Do not insert fingers, rods or other objects into the air inlet or outlet. When the fan is rotating at high speed, it will cause injury.
Never let the air handling unit or the remote controller get wet. It may cause an electric shock or a fire.
Never use a flammable spray such as hair spray, lacquer or paint near the unit. It may cause a fire.
Never replace a fuse with that of wrong ampere ratings or other wires when a fuse blows out. Use of wire or copper wire may cause the unit to break down or cause a fire.
Never put any objects into the air inlet or outlet. Objects touching the fan at high operating speed can be dangerous.
Never press the button of the remote controller with a hard, pointed object. The remote controller may be damaged.
Never pull or twist the electric wire of the remote controller. It may cause the unit to malfunction.
Never inspect or service the unit by yourself. Ask a qualified service person to perform this work.
To prevent refrigerant leak, contact your dealer. When the system is installed and runs in a small room, it is required to keep the concentration of the refrigerant, if by any chance coming out, below the limit. Otherwise, oxygen in the room may be affected, resulting in a serious accident.
The refrigerant in the air conditioner is safe and normally does not leak. If the refrigerant leaks in the room, contact with a fire of a burner, a heater or a cooker may result in a harmful gas. Tu rn off any combustible heating devices, ventilate the room and contact the dealer where you purchased the unit. Do not use the air conditioner until a service person confirms that the portion where the refrigerant leaks is repaired.
Improper installation or attachment of equipment or accessories could result in electric shock, short-circuit, leaks, fire or other damage to the equipment. Be sure to use only accessories made by Daikin which are specifically designed for use with the equipment and have them installed by a professional.
Ask your dealer to move and reinstall the air conditioner. Incomplete installation may result in a water leakage, electric shock, and fire.
ERQ100~140A7V1B + ERQ125~250A7W1B Inverter condensing unit 4PW51322-1
Operation manual
1
Loading...