Daikin EKRTR, EKRTETS Installation manuals

EKRTR EKRTETS
INSTALLATION MANUAL
Room thermostat
1.5 m
>0.2 m
>0.2 m
1
2
12
3
±1.5 m
±1.5 m
>0.2 m
>0.2 m
3
5
4
60
87
12534
28 50
4
5
EKRTR EKRTETS
Room thermostat Installation manual
Read this manual attentively before starting up the unit. Do not throw it away. Keep it in your files for future reference.
The English text is the original instruction. Other languages are translations of the original instructions.
Improper installation or attachment of equipment or accessories could result in electric shock, short-circuit, leaks, fire or other damage to the equipment. Be sure only to use accessories made by Daikin which are specifically designed for the use with the equipment and have them installed by a professional.
If unsure of installation procedures or use, always contact your dealer for advice and information.
Contents
1. Introduction ............................................................................2
2. Installation of EKRTETS as floor temperature sensor
(only for floor heating/cooling applications)............................ 3
3. Installation of the EKRTR....................................................... 6
4. Setting up codes in the installer menu .................................14
5. Technical characteristics ...................................................... 24
EKRTR + EKRTETS Room thermostat 4PW56105-1
Installation manual
1

1. Introduction

The room thermostat EKRTR can be used to control the Daikin system (radiator heating and floor heating/cooling applications).
It is typically connected to the Daikin unit. Refer to the "Typical application examples" in the Installation manual of the Daikin unit.
In case of floor heating-only applications the room thermostat can also be connected to the individual motorized valve of the floor heating loop.
If a floor heating-only application is used in combination with fan coil units each fan coil unit should have its dedicated fan coil thermostat.
Optionally, an external temperature sensor EKRTETS can be connected to the thermostat and used as:
external ambient temperature sensor to control the room temperature (instead of the temperature sensor inside the thermostat). In that case, install the temperature sensor where you want to control the ambient temperature.
floor temperature sensor (only for floor heating/cooling applications) to protect the floor temperature or to prevent dew on the floor (in case of floor cooling). In that case, install the temperature sensor in the floor (refer to "Installation of
EKRTETS as floor temperature sensor (only for floor heating/cooling applications)" on page 3).
In case of extreme or sudden changes in weather conditions, despite the dew prevention function, condensation on the floor could occur.
To avoid reoccurrence, we suggest changing the field settings (refer to "Set-up floor temperature
protection and dew prevention function (only for floor heating/cooling applications)" on page 15.
In case the conditions are so extreme that this countermeasure is not adequate, we suggest not to use floor cooling.
Installation manual
2
EKRTR + EKRTETS
Room thermostat
4PW56105-1
2. Installation of EKRTETS as floor
temperature sensor (only for floor heating/ cooling applications)
As it should be integrated into the floor, the installation of the temperature sensor EKRTETS should be planned and performed in advance.
If EKRTETS is installed as floor temperature sensor, the thermostat EKRTR should be wall-mounted. Refer to "Wall-
mounted installation" on page 6.
The below procedure only serves as an example.
NOTE
Your actual situation may differ from what is represented here.
1
Ta ke the installation suggestions for the thermostat into account when selecting the installation location.
Refer to figure 3.
EKRTR + EKRTETS Room thermostat 4PW56105-1
Installation manual
3
2
Integrate the EKRTETS temperature sensor in an electrical conduit (∅16 mm maximum) in the floor construction as shown below.
Make sure to seal the temperature sensor electrical conduit to protect the thermostat from hot air currents and to allow the replacement of the temperature sensor.
1 2 3 4
3
Pass the temperature sensor cable through the conduit until
figure1
2
413
Thermostat
Temperature sensor conduit (Ø16 mm maximum)
Temperature sensor EKRTETS (in conduit with seal)
Water pipes
it reaches the seal.
Installation manual
4
EKRTR + EKRTETS
Room thermostat
4PW56105-1
4
Connect the temperature sensor cable to the thermostat as described in "Wall-mounted installation" on page 6.
Install the temperature sensor as close as possible
NOTE
to the floor loop inlet and as close as possible to the floor surface as shown in the figure on page 4.
EKRTR + EKRTETS Room thermostat 4PW56105-1
Installation manual
5

3. Installation of the EKRTR

You can mount the EKRTR thermostat on the wall or use it as table-top model.

3.1. Wall-mounted installation

The EKRTR thermostat can be wall-mounted, with supplied screws and plugs. Refer to figure 1.
This is the case when you want to install the optional EKRTETS as external temperature sensor.
1
At the left of the thermostat, gently push the lid.
2
Remove the front cover by pulling it towards you.
3
Optionally for the EKRTETS, unscrew the screw of the cable holder in the bottom left corner of the back part of the thermostat and remove the transparent cable protection.
4
Remove the battery insulator.
4
1
5
Drill holes in the wall taking the dimensions of the thermostat into account and insert the supplied plugs in the holes.
Refer to figure 4 (unit of measurement: mm).
3
3
2
3
Installation manual
6
EKRTR + EKRTETS
Room thermostat
4PW56105-1
6
Optionally, pass the temperature sensor wiring (EKRTETS) through the back of the thermostat and wire it as shown below.
7
Fasten the thermostat with the supplied screws.
Be careful not to pinch the wiring when fastening.
8
Optionally for the EKRTETS, put the transparent cable protection back into place and fix the cable protection with the screw.
9
Close the thermostat cover.
10
Remove the protective film from the LCD.

3.2. Table-top installation of the thermostat

Only if the optional temperature sensor EKRTETS
is not installed as external temperature sensor, the EKRTR can be used as a table-top model.
In that case, no particular installation for the thermostat is needed. The thermostat functions as a complete wireless unit and can be put anywhere in the house into its table holder.
Remove the battery insulator and the protective film from the LCD, as described in "Wall-mounted installation" on page 6.
EKRTR + EKRTETS Room thermostat 4PW56105-1
Installation manual
7
Loading...