We would first of all like to thank you for having chosen one of our products.
U
I
S
We are sure you will be happy with it because it represents the state of the art in the technology of
home air conditioning.
By following the suggestions contained in this manual, the product you have purchased will operate
without problems, giving you optimum room temperatures with minimum energy costs.
DAIKIN EUROPE N.V.
Compliance
This unit complies with the following European Directives:
• Low voltage 2014/35/EU;• Electro-magnetic compatibility 2014/30/EU;
Symbols
The pictograms in the next chapter provide the necessary
information for correct, safe use of the appliance in a rapid,
Editorial pictograms
User
- Refers to pages containing instructions or information
for the user.
Installer
- Refers to pages containing instructions or information
for the installer.
Safety pictograms
Warning
- The operation described may cause physical harm if
not carried out in accordance with safety regulations.
unmistakable way.
Service
- Refers to pages containing instructions or information
for the CUSTOMER TECHNICAL ASSISTANCE
SERVICE installer.
High temperature danger
- Of safety regulations, the risk of burns caused by
contact with components with high temperatures.
Dangerous electrical current
- Make personnel aware that the operation described
may lead to electrical shocks if not carried out in
accordance with safety regulations.
Prohibition
- Refers to prohibited actions.
2
1 GENERAL
1.1 General warnings ...................................................................5
1.2 Fundamental safety rules ............................................................. 5
2 EKRTCTRL1
2.1 SMART TOUCH electronic control panel with device side continuous modulation ....................6
This instruction is an integral part of the booklet of the
This manual is designed only for the qualified and
All operations must be carried out with care and
After unpacking, check that the contents are intact and
1.2
Remember that some fundamental safety rules should
General waenings
appliance on which the kit is installed. Please consult
this booklet for general warnings and fundamental safety
rules.
authorised installation technician, who must be
sufficiently trained and in possession of all psychophysical requirements as per the law.
according to best practices, and in compliance with
workplace safety regulations.
that all parts are included. If not, contact the agent who
sold the appliance to you.
Fundamental safety rules
be followed when using a product that uses electricity
and water, such as:
It is forbidden to modify the safety or adjustment
devices without authorisation from and indications of the
manufacturer.
It is forbidden to dispose of, or leave in the reach of
children, the packaging materials which could become
a source of danger.
Repairs or maintenance must be performed by the
Technical Assistance Service or by qualified personnel
in accordance with this manual. Do not modify or tamper
with the appliance as this could create dangerous
situations and the manufacturer will not be liable for any
damage caused.
It is forbidden to pull, cut or knot the electrical cables
coming out of the appliance, even if it is disconnected
from the mains supply.
The unit can be used by children over the age of
8, and by people with reduced physical, sensory or
mental capabilities, or with no experience or necessary
knowledge, as long as they are monitored or after they
have received instructions on the safe use of the unit
and have understood the dangers involved.
Children must not play with the appliance.
The cleaning and maintenance that must be
performed by the user should not be carried out by
children without supervision.
It is forbidden to touch the appliance with wet hands
or body when barefoot.
It is forbidden to carry out any cleaning before having
disconnected the appliance from the electricity mains
supply by turning the system master switch to "OFF".
It is forbidden to modify the safety or adjustment
devices or adjust without authorisation and indications
of the manufacturer.
It is forbidden to poke objects or anything else through
the inlet or outlet grills.
It is forbidden to open the doors which access the
internal parts of the appliance without first turning the
system master switch to "OFF".
It is forbidden to dispose of or leave in the reach of
children the packaging materials which could become
a source of danger.
It is forbidden to climb onto the appliance or rest any
object on it.
The external parts of the appliance can reach
temperatures of more than 70°C.
5
SUI
A
B
EKRTCTRL1
2.1
These controls make room temperature adjustment (with
offset settable from the keyboard) completely autonomous
through the AUTO, SILENT, NIGHT and MAX programmes
by means of a probe located in the lower part of the device,
ensuring anti-freeze safety even when set to stand-by.
The control panel has a memory, so settings will not be
lost if the appliance is switched off or in the power supply
is cut.
2.2
Any statuses and alarms are also shown on the display by
using 8 specific symbols:
SMART TOUCH electronic control panel with device side continuous modulation
Controls cannot be installed on the FWXM-series.
ADisplay
BKeys
Display
After 20 seconds from the last action the panel
brightness will be reduced for improved night-time
comfort, and the room temperature will appear on the
display. Press any key to restore maximum brightness.
The 10 kΩ water temperature probe positioned in the
device battery regulations the minimum level when heating
(30°C) and the maximum level when cooling (20°C).
Automatic operation
Silent operation
Maximum ventilation speed
Night-time operation
Heating on
2.3
The various functions are set using 8 backlit keys:
Key function
Temp + is for increasing the set temperature
Temp - is for decreasing the set temperature
Heating / Cooling: for changing the operation
mode between heating and cooling
Cooling on
Supervision on Flashing with presence switch CP
closed.
Alarm indicator (solid light)
Panel off indicator
Resistance active indicator
Night-time operation: limits ventilation speed
to a contained level and the set temperature
is adjusted automatically.
Maximum speed operation: Allows for the
maximum ventilation speed to be set
ON/Stand-By: for activating the device or for
putting it in stand-by.
Sets the regulation ventilation speed between
a minimum and maximum value to an entirely
automatic mode
Silent: limits ventilation speed to a more
contained value
6
SUI
2.4
General On Switch
In order to manage the device via the control panel, this
must be connected to the mains electricity.
If a general switch is installed on the power line, this must
2.5
To activate the device
KeyOperationDisplay
2.6
KeyOperationDisplay
Activation
Press the ON Stand-by keyFrom off to on
Select one of the 4 operating modes by pressing the relative key.
Heating/cooling operation modes setting
Keep the Heating / Cooling key pressed for approx. 2 seconds to change the mode
between heating and cooling, which is indicated by the 2 symbols that appear if heating
or cooling is active.
also be switched on.
- Turn the device on by activating the general switch
When heating, the symbol displays when the set point is higher than ambient
temperature, both are off when the set point is lower.
When cooling, the symbol displays when the set point is lower than ambient temperature,
both are off when the set point is higher.
One of the two symbols flashing means that the water
temperature (hot or cold) is not sufficient, and stops
the fan until the temperature reaches a level suitable for
reaching the required temperature.
2.7
KeyOperationDisplay
When the control is in this operating mode, anti freezing is
in any case guaranteed. If the ambient temperature drops
2.8
KeyOperationDisplay
Stand By
Press and hold the ON Stand-By key for approx. 2 seconds. No illuminated signals on
the display at all means that the system is in stand-by (no operation).
Temperature selection
If after switching the power on the board detects the
H2 probe, start-up occurs in normal conditions with the
minimum and maximum thresholds.
The board also has a function when there is no H2 probe,
in such cases the fan stop thresholds are ignored.
Off
below 5°C, the solenoid valves on the hot water output
and the boiler are opened.
Set the required room temperature using the two increase/decrease keys to set the
temperature value on the 3-digit display.
The adjustment range is from 16 to 28°C in intervals of
0.5°C, but out-of-range values are also accepted, from
5°C to 40°C (unless in auto mode).
Only set these values for brief periods, and then set a
intermediate value.
The controller is very precise - set it to the required value
and wait for the controller to regulate itself according to the
actual room temperature detected.
20.5
7
SUI
2.9
KeyOperationDisplay
Automatic operation
Press and hold the AUTO key. The function being activated is indicated by the relevant
symbol appearing on the display.
Ventilation speed adjustment is carried out automatically
between the minimum and maximum values, according to
2.10
KeyOperationDisplay
Ventilation speed is limited to a contained maximum value.
2.11
KeyOperationDisplay
By selecting this mode, ventilation speed is limited to a
very contained level and the set temperature is adjusted
automatically, as follows:
2.12
Silent operation
Press and hold the Silent key. The function being activated is indicated by the relevant
symbol appearing on the display.
Night-time operation
Press and hold the Night-time operation key. The function being activated is indicated
by the relevant symbol appearing on the display.
Operation at maximum ventilation speed
the distance of the actual room temperature from the set
point, according to a PI-type algorithm.
- decreases by 1°C after one hour and by another degree
after two hours in heating mode;
- increases by 1°C after one hour and by another degree
after two hours in cooling mode;
KeyOperationDisplay
Press and hold the Max Operation key. The function being activated is indicated by the
relevant symbol appearing on the display.
In this operation mode, the maximum possible power level
is activated whether heating or cooling.
2.13
KeyOperationDisplay
2.14
After 20 seconds from the last action, the panel brightness
will be reduced for improved night-time comfort, and the
room temperature will appear on the display.
KeyOperationDisplay
Key lock
By pressing both the + and - keys for 3 seconds, all keys are locked locally, and this is
indicated by "bL" appearing on the display.
All actions are disabled to the user and whenever any key is pressed, "LOC" will appear.
To unlock the keys, repeat the sequence.
Reduce brightness to minimum
With the display off, press and hold the + key for 5 seconds until "01" is displayed.
Use the - key to change the value to 00 and wait 20 seconds to check the setting has
been accepted.
Once the desired room temperature is reached, we
recommend selecting one of the other 3 operation modes
for increased comfort and sound levels.
bL
If this brightness is still disturbing, the display can be
switched off completely.
00
8
SUI
2.15
KeyOperationDisplay
Deactivation
Press and hold the ON Stand-By key for approx. 2 seconds. No illuminated signals on
the display at all means that the system is in stand-by (no operation).
The controller also ensures anti freezing when in stand-by.
2.16
As the detection probe is towards the bottom of the
device, the temperature detected may at times differ from
the actual room temperature.
By using this function, the value displayed can be adjusted
in a range from -9/+12 K in intervals of 0.1°C.
KeyOperationDisplay
2.17
When switching off for a season or for holidays, proceed
as follows:
- Deactivate the device
Room temperature probe regulation offset
Use this adjustment with care, and only after having
actually detected a discrepancy compared with the actual
room temperature using a reliable device!
With the display off, press and hold the - key for 5 seconds to access the menu which
allows adjustment (using the + and - keys) of the AIR probe offset displayed, from -9
to +12 K in 0.1 K intervals.
After 20 seconds from the last action, the panel switches off and the setting is stored.
Switching off for long periods
- Turn the general unit switch to off.
The antifreeze function is not active.
Off
00.0
2.18
ErrorDisplay
Faulty room temperature (AIR) probe
Problem with fan motor (e.g. blockage caused by foreign objects, faulty rotation sensor).
Water temperature probe fault
In this case, ensure that the probe installed is 10 kΩ.
Engaging of grille microswitch S1 due to filter cleaning operation
The flashing of one of the 2 symbols indicates that the water temperature (hot or cold) is not
and causes the fan to Stop.
Error signals
E1
E2
E3
Gr
9
SUI
EKWHCTRL1
3.1
The remote wall-mounted control EKWHCTRL1 is an
electronic thermostat with a room temperature probe for
controlling one or more (up to a maximum of 30) fan coils
/ cooler-radiators in broadcast mode (with simultaneous
control transmission) equipped with electronic control for
EKWHCTRL0 remote operation .
The control panel has a memory, so settings will not be lost
if the appliance is switched off or in the power supply is cut.
3.2
Any statuses and alarms are also shown on the display by
using 8 specific symbols:
Wall-mounted SMART TOUCH electronic control panel with room probe
Any anomalies on individual connected terminal are
not indicated on the wall panel.
Display
Anti-freeze protection is guaranteed via the
temperature probe when in stand-by.
After 20 seconds from the last action, the panel
brightness will be reduced and the room temperature
will appear on the display. Press any key to restore
maximum brightness.
Automatic operation
Silent operation
Maximum ventilation speed
Night-time operation
Heating on
3.3
The various functions are set using 8 backlit keys:
Key function
Temp + is for increasing the set temperature
Temp - is for decreasing the set temperature
Heating / Cooling: for changing the operation
mode between heating and cooling
Cooling on
Supervision on Flashing with presence switch CP
closed.
Alarm indicator (solid light)
Panel off indicator
Resistance active indicator
Night-time operation: limits ventilation speed
to a contained level and the set temperature
is adjusted automatically.
Maximum speed operation: Allows for the
maximum ventilation speed to be set
ON/Stand-By: for activating the device or for
putting it in stand-by.
Sets the regulation ventilation speed between
a minimum and maximum value to an entirely
automatic mode
Silent: limits ventilation speed to a more
contained value
10
SUI
3.4
General On Switch
In order to manage the device via the control panel, this
must be connected to the mains electricity.
If a general switch is installed on the power line, this must
3.5
To activate the device
KeyOperationDisplay
3.6
KeyOperationDisplay
Activation
Press the ON Stand-by keyFrom off to on
Select one of the 4 operating modes by pressing the relative key.
Heating/cooling operation modes setting
Keep the Heating / Cooling key pressed for approx. 2 seconds to change the mode
between heating and cooling, which is indicated by the 2 symbols that appear if heating
or cooling is active.
also be switched on.
- Turn the device on by activating the general switch
When heating, the symbol displays when the set point is higher than ambient
temperature, both are off when the set point is lower.
When cooling, the symbol displays when the set point is lower than ambient temperature,
both are off when the set point is higher.
3.7
KeyOperationDisplay
When the control is in this operating mode, anti freezing is
in any case guaranteed. If the ambient temperature drops
3.8
KeyOperationDisplay
Stand By
Press and hold the ON Stand-By key for approx. 2 seconds. No illuminated signals on
the display at all means that the system is in stand-by (no operation).
below 5°C, the solenoid valves on the hot water output
and the boiler are opened.
Temperature selection
Set the required room temperature using the two increase/decrease keys to set the
temperature value on the 3-digit display.
Off
20.5
The adjustment range is from 16 to 28°C in intervals of
0.5°C, but out-of-range values are also accepted, from
5°C to 40°C (unless in auto mode).
Only set these values for brief periods, and then set a
intermediate value.
The controller is very precise - set it to the required value
and wait for the controller to regulate itself according to the
actual room temperature detected.
11
SUI
3.9
KeyOperationDisplay
Automatic operation
Press and hold the AUTO key. The function being activated is indicated by the relevant
symbol appearing on the display.
Ventilation speed adjustment is carried out automatically
between the minimum and maximum values, according to
3.10
KeyOperationDisplay
Ventilation speed is limited to a contained maximum value.
3.11
KeyOperationDisplay
By selecting this mode, ventilation speed is limited to a
very contained level and the set temperature is adjusted
automatically, as follows:
3.12
Silent operation
Press and hold the Silent key. The function being activated is indicated by the relevant
symbol appearing on the display.
Night-time operation
Press and hold the Night-time operation key. The function being activated is indicated
by the relevant symbol appearing on the display.
Operation at maximum ventilation speed
the distance of the actual room temperature from the set
point, according to a PI-type algorithm.
- decreases by 1°C after one hour and by another degree
after two hours in heating mode;
- increases by 1°C after one hour and by another degree
after two hours in cooling mode;
KeyOperationDisplay
Press and hold the Max Operation key. The function being activated is indicated by the
relevant symbol appearing on the display.
In this operation mode, the maximum possible power level
is activated whether heating or cooling.
3.13
KeyOperationDisplay
3.14
After 20 seconds from the last action, the panel brightness
will be reduced for improved night-time comfort, and the
room temperature will appear on the display.
KeyOperationDisplay
Key lock
By pressing both the + and - keys for 3 seconds, all keys are locked locally, and this is
indicated by "bL" appearing on the display.
All actions are disabled to the user and whenever any key is pressed, "LOC" will appear.
To unlock the keys, repeat the sequence.
Reduce brightness to minimum
With the display off, press and hold the + key for 5 seconds until "01" is displayed.
Use the - key to change the value to 00 and wait 20 seconds to check the setting has
been accepted.
Once the desired room temperature is reached, we
recommend selecting one of the other 3 operation modes
for increased comfort and sound levels.
bL
If this brightness is still disturbing, the display can be
switched off completely.
00
12
SUI
3.15
KeyOperationDisplay
Deactivation
Press and hold the ON Stand-By key for approx. 2 seconds. No illuminated signals on
the display at all means that the system is in stand-by (no operation).
The controller also ensures anti freezing when in stand-by.
3.16
As the detection probe is towards the bottom of the
device, the temperature detected may at times differ from
the actual room temperature.
By using this function, the value displayed can be adjusted
in a range from -9 to +12 K in intervals of 0.1°C.
KeyOperationDisplay
3.17
Room temperature probe regulation offset
Use this adjustment with care, and only after having
actually detected a discrepancy compared with the actual
room temperature using a reliable device!
With the display off, press and hold the - key for 5 seconds to access the menu which
allows adjustment (using the + and - keys) of the AIR probe offset displayed, from -9
to +12 K in 0.1 K intervals.
After 20 seconds from the last action, the panel switches off and the setting is stored.
Switching off for long periods
Off
00.0
When switching off for a season or for holidays, proceed
as follows:
- Deactivate the device
3.18
ErrorDisplay
Room temperature probe fault (on the thermostat).
Fault or connection of a double remote room probe on board one of the fan coil units connected.
Error signals
- Turn the general unit switch to off.
The antifreeze function is not active.
E1
E2
13
SUI
A
B
EKRTCTRL2
4.1
These controls make room temperature adjustment (with
offset settable from the keyboard) completely autonomous
through the four speeds by means of a probe located in
the lower part of the device, ensuring anti-freeze safety
even when set to stand-by.
The control panel has a memory, so settings will not be
lost if the appliance is switched off or in the power supply
is cut.
ADisplay
BKeys
4.2
Any statuses and alarms are also shown on the display by
using 8 specific symbols:
SMART TOUCH electronic control panel with fixed speed modulation
Controls cannot be installed on the FWXM-series.
Display
After 20 seconds from the last action the panel
brightness will be reduced for improved night-time
comfort, and the room temperature will appear on the
display. Press any key to restore maximum brightness.
The 10 kΩ water temperature probe positioned in the
device battery regulations the minimum level when heating
(30°C) and the maximum level when cooling (20°C).
Automatic operation in steps
Minimum operation
Maximum ventilation speed
Super silent operation
Heating on
4.3
The various functions are set using 8 backlit keys:
Key function
Temp + is for increasing the set temperature
by 1 K
Temp - is for decreasing the set temperature
by 1 K
Heating / Cooling: for changing the operation
mode between heating and cooling
Cooling on
Supervision active (flashing light)
Alarm indicator (solid light)
Panel off indicator
Resistance active indicator
The super silent setting activates powerful
dehumidifying when cooling and only radiation
when heating.
Maximum speed operation: Allows for the
maximum ventilation speed to be set
ON/Stand-By: for activating the device or for
putting it in stand-by.
In automatic mode, the fan carries out a
"stepped" adjustment to move the room
temperature closer to the set point.
Minimum: limits ventilation speed to a very
contained value
14
SUI
4.4
General On Switch
In order to manage the device via the control panel, this
must be connected to the mains electricity.
If a general switch is installed on the power line, this must
4.5
To activate the device
KeyOperationDisplay
4.6
KeyOperationDisplay
Activation
Press the ON Stand-by keyFrom off to on
Select one of the four speeds by pressing the relevant key.
Heating/cooling operation modes setting
Keep the Heating / Cooling key pressed for approx. 2 seconds to change the mode
between heating and cooling, which is indicated by the 2 symbols that appear if heating
or cooling is active.
also be switched on.
- Turn the device on by activating the general switch
When heating, the symbol displays when the set point is higher than ambient
temperature, both are off when the set point is lower.
When cooling, the symbol displays when the set point is lower than ambient temperature,
both are off when the set point is higher.
One of the two symbols flashing means that the water
temperature (hot or cold) is not sufficient, and stops
the fan until the temperature reaches a level suitable for
reaching the required temperature.
If after switching the power on the board detects the
4.7
KeyOperationDisplay
When the control is in this operating mode, anti freezing is
in any case guaranteed. If the ambient temperature drops
4.8
KeyOperationDisplay
Stand By
Press and hold the ON Stand-By key for approx. 2 seconds. No illuminated signals on
the display at all means that the system is in stand-by (no operation).
Temperature selection
H2 probe, start-up occurs in normal conditions with the
minimum and maximum thresholds.
The board also has a function when there is no H2 probe,
in such cases the fan stop thresholds are ignored.
From on to off
below 5°C, the solinoid output is opened.
Set the required room temperature using the two increase/decrease keys to set the
temperature value on the 3-digit display.
The adjustment range is from 16 to 28°C in intervals of 1
°C, but out-of-range values are also accepted, from 5°C
to 40°C (unless in auto mode).
Only set these values for brief periods, and then set a
intermediate value.
20
15
SUI
4.9
KeyOperationDisplay
Ventilation speed regulation
The fan speed is selected by using one of the 4 keys (automatic, minimum, super silent
and maximum). The activation of the function is indicated by
the relevant symbol on the display.
In automatic mode, the fan carries out a "stepped"
adjustment to move the room temperature closer to the
set point.
The super silent setting activates powerful dehumidifying
when cooling and only radiation (with the fan off, solenoid
valve, and in the RS version, microfans activated) when
heating.
4.10
KeyOperationDisplay
4.11
After 20 seconds from the last action, the panel brightness
will be reduced for improved night-time comfort, and the
room temperature will appear on the display.
If this brightness is still disturbing, the display can be
Key lock
By pressing both the + and - keys for 3 seconds, all keys are locked locally, and this is
indicated by "bL" appearing on the display.
All actions are disabled to the user and whenever any key is pressed, "LOC" will appear.
To unlock the keys, repeat the sequence.
Reduce brightness to minimum
By setting the highest speed, the maximum possible
power level is activated immediately whether heating or
cooling.
Once the desired room temperature is reached, we
recommend selecting one of the other 3 operation modes
for increased comfort and sound levels.
In "minimum" mode, the number of fan revolutions is
limited both when heating and cooling.
bL
switched off completely.
16
KeyOperationDisplay
With the display off, press and hold the + key for 5 seconds until "01" is displayed.
Use the - key to change the value to 00 and wait 20 seconds to check the setting has
been accepted.
4.12
KeyOperationDisplay
The controller also ensures anti freezing when in stand-by.
Deactivation
Press and hold the ON Stand-By key for approx. 2 seconds. No illuminated signals on
the display at all means that the system is in stand-by (no operation).
00
From on to off
SUI
4.13
Room temperature probe regulation offset
As the detection probe is towards the bottom of the
device, the temperature detected may at times differ from
the actual room temperature.
By using this function, the value displayed can be adjusted
in a range from -9 to +12 K in intervals of 1°C.
KeyOperationDisplay
With the display off, press and hold the - key for 5 seconds to access the menu which
allows adjustment (using the + and - keys) of the AIR probe offset displayed, from -9
to +12 K in 1 K intervals.
After 20 seconds from the last action, the panel switches off and the setting is stored.
4.14
When switching off for a season or for holidays, proceed
as follows:
- Deactivate the device
4.15
ErrorDisplay
Switching off for long periods
Error signals
Use this adjustment with care, and only after having
actually detected a discrepancy compared with the actual
room temperature using a reliable device!
00
- Turn the general unit switch to off.
The antifreeze function is not active.
Faulty room temperature (AIR) probe
Problem with fan motor (e.g. blockage caused by foreign objects, faulty rotation sensor).
Water temperature probe fault.
In this case, ensure that the probe installed is 10 kΩ.
Engaging of grille microswitch S1 due to filter cleaning operation
E1
E2
E3
Gr
17
SUI
A
EKPCBO
5.1
The command is for switching on and off and selecting the
4 speeds directly from the fan coil.
Switching on and off takes place via closing of the external
thermostat contact.
The control panel has a memory, so settings will not be lost
if the appliance is switched off or in the power supply is cut.
On-board speed selector for connecting to standard thermostat
Controls cannot be installed on the FWXM-series.
After 20 seconds from the last action, the LED brightness
will be reduced for improved night-time comfort. Press
any key to restore maximum brightness.
A
B
mode
A
Warning Led
speed selection key
o
B
5.2
The 5 LEDs display the operational states:
5.3
To manage the fan coil via the selector, it must be
connected to the mains and to a room thermostat with a
single 230V AC contact.
LED indications
Minimum speed selected
Medium speed selected
Maximum speed selected
General On Switch
Supersilent function selected
Fan coil off or TA contact open (flashing)
If a general switch is installed on the power line, this must
also be switched on.
- Turn the device on by activating the general switch
18
SUI
5.4
To activate the device
KeyOperationDisplay
Activation
Press the mode/off keyOff → On
Select one of the 4 operating speeds by pressing the relative mode/off key. If the red
symbol is flashing, it means that the room thermostat is not connected; it therefore
needs to be activated.
5.5
KeyOperationDisplay
5.6
KeyOperationDisplay
By setting the highest speed, the maximum possible
power level is activated immediately whether heating or
cooling.
5.7
KeyOperationDisplay
Stand By
Press and hold the mode/off key for approx. 2 seconds. No illuminated signals on the
display at all means that the system is in stand-by (no operation).
Ventilation speed regulation
Each time the mode/off button is pressed the fan speed moves between supersilent,
minimum, medium and maximum.
The function being activated is indicated by the relevant symbol appearing on the
display.
Once the desired room temperature is reached, we
recommend selecting one of the other 3 operation modes
for increased comfort and sound levels.
Deactivation
Press and hold the mode/off key for approx. 2 seconds. No illuminated signals on the
display at all means that the system is in stand-by (no operation).
Off → On
Off
5.8
When switching off for a season or for holidays, proceed
as follows:
5.9
The board provides diagnostics in the event of anomalies,
which can be interpreted from combinations of LEDs.
The following table summarises the warnings.
• Flashing LED : TERM contact open
• Flashing LED : TERM contact closed;
• 4 flashing LEDs: GRID contact open;
Switching off for long periods
- Deactivate the device
- Turn the general unit switch to off.
Error status warnings
• LED on: supersilent speed active (400 rpm).
• LED on: minimum speed active (680 rpm).
• LED on: medium speed active (1,100 rpm).
• LED on: maximum speed active (1,500 rpm).
19
SUI
MAINTENANCE
6.1
Before every cleaning and maintenance intervention,
Wait until the parts have cooled down to avoid the risk
External cleaning
disconnect the appliance from the mains by switching
off the master switch.
of burns.
Do not use abrasive sponges or abrasive or corrosive
detergents to avoid damaging the painted surfaces.
When necessary, clean the outer surfaces of the heat
pump convector with a soft damp cloth.
6.2
After a period of continuous operation and in consideration
of the concentration of impurities in the air, or when he
Cleaning air suction filter
Extraction of filter cells
To remove the grill:
- lift the grill until it is completely released from the seat
intends to restart the plant after a period of inactivity,
proceed as described.
- lit the grill and slide it outwards
- then remove the filter by pulling it outwards
20
SUI
A
B
Front grill
Grill hook
Filter
C
C
A
B
A
C
Cleaning filtering seats
- suck up the powder with a vacuum cleaner
- wash the filter with running water without using
detergents or solvents, and leave to dry.
It is forbidden to use the unit without the net filters.
The appliance is fitted with a safety switch that
prevents the operation of the cooler with the mobile
panel missing or out of position.
After finishing the cleaning of the filter, check that the
panel is mounted correctly.
21
SUI
C
B
A
A
C
B
A
A
Ending Cleaning Operations
- For the versions with a grill with flaps, insert the two
lugs into the special slots, turn it and hook it up with a
slight tap on the upper part.
Filter
A
Grill hook
B
AD
Front grill
C
The filter housing
D
6.3
- Always keep the filters clean;
- when far possible, keep the doors and windows
Energy saving tips
closed in the room being conditioned;
- limit where possible the effect of direct sun rays in the
rooms being conditioned (use curtains, shutters etc.)
22
SIU
TROUBLESHOOTING
7.4
In the event of water leaks or anomalous operation,
If one of the following anomalies should
7.5
Maintenance must be carried out by a qualified installer or
by a specialised service centre.
EffectCauseSolution
Ventilation takes a long time to start
when new temperature settings or
anew mode is activated.
The device doesn't start ventilating.No hot or cold water in the system.
Ventilation does not start even if there is
hot or cold water in the hydraulic circuit.
The device leaks water when heating.
Rust is forming on the front panel.Thermal isolators detached.
Water droplets are forming on the grill
and the air outlet.
The device leaks water only when
cooling.
The device makes excessive noise.
Troubleshooting
disconnect mains power immediately and close all
water taps.
occur, contact an authorised service centre
or qualified personnel, do not try to repair yourself.
Troubleshooting table
The circuit valve needs time to open
and to let cold or hot water circulate.
The hydraulic valve stays closed.
The fan motor is blocked or burned out.
The microswitch that stops ventilation
when opening the filter grill doesn't
close properly.
Electrical connections are incorrect.Check the electrical connections.
Water leakage from the system
plumbing.
Leaks from the valve group.Check the seals.
In high relative ambient humidity (>60%),
condensation may occur, especially
when the fan is at its minimum speed.
The condensation tank is blocked.
The condensation drain does not have
sufficient incline to drain.
The connection pipes and valve group
are not well isolated.
The fan is touching the structure.
The fan is unbalanced.
Check for dirt in filters and if necessary,
clean them.
- Ventilation does not start even if there is hot or cold
water in the hydraulic circuit.
- The device leaks water when heating.
- The device leaks water only when cooling.
- The device makes excessive noise.
- Rust is forming on the front panel.
Wait 2 or 3 minutes for the circuit valve
to open.
Check that the boiler or the water cooler
are working.
Disassemble the valve body and check
and restore water circulation.
Check that the valve is working by
powering it up separately from a 230V
supply. If it starts working, the problem
may be with the electronic controller.
Check the motor windings and that the
fan can turn freely.
Check that closing the grill closes the
contact on the microswitch.
Check for leaks and tighten all
connections.
Check that the thermal sound isolators
are positioned correctly, paying
particular attention to the one positioned
at the front above the winged battery.
As soon as relative humidity decreases,
the problem will disappear. In any case,
should some water droplets fall inside
the units, it does not mean that there is
a malfunction.
Slowly pour a bottle of water in the lower
part of the battery to check drainage; if
required, clean the tank and/or improve
the incline of the drain tube.
Check pipe insulation.
Check for dirt in filters and if necessary,
clean them.
An unbalanced fan causes excessive
vibrations in the machine: replace the
fan.
Clean the filters.
23
Copyright 2019 Daikin