CAREFULLY READ THIS OPERATION MANUAL
BEFORE USING THE UNIT. IT WILL TELL YOU HOW TO
USE THE UNIT PROPERLY AND HELP YOU IF ANY
TROUBLE OCCURS. AFTER READING THE MANUAL,
FILE IT AWAY FOR FUTURE REFERENCE.
The English text is the original instruction. Other languages are
translations of the original instructions.
This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.
This unit contains electrical and hot parts.
Before operating the unit, make sure the installation
has been carried out correctly by a professional
dealer.
If you feel unsure about operation, contact your dealer
for advice and information.
I
NTRODUCTION
General information
Thank you for purchasing this Daikin indoor unit.
The unit is the indoor part of the air to water ERSQ or ERRQ heat
pump. The unit is designed for floor standing indoor installation and
used for heating applications. The unit can be combined with space
heating radiators (field supply) and with an EKHTS* domestic hot
water tank (option).
A remote controller with room thermostat functionality is standard
supplied with this unit to control your installation.
NOTE
An EKHBRD indoor unit can only be connected to an
outdoor ERSQ or ERRQ-series.
Refer to the installation manual for the list of options.
Scope of this manual
Operation manual
1
This manual describes how to start up and switch off the unit, set
parameters and configure the schedule timer by means of the
controller, maintain the unit and solve operational problems.
Refer to the installation manual of the indoor unit for
installation procedures.
Indoor unit for air to water heat pump system and options
EKHBRD011~016AAV1+Y1
4PW54466-1A
Page 3
■
■
■
■
■
■
Q
UICK
START
In this chapter the step-by-step procedure is explained for starting up
both space heating and domestic water heating.
The more detailed information of how the unit must be operated is
explained in the chapter "Operation of the unit" on page 2.
The quick start-up offers the user the possibility to start up the
system before reading the entire manual.
-
UP
OF
THE
UNIT
Space heating operation
Push the bi or bj button
Display:
Set desired room
temperature (e.g. 22°C)
You have "room
temperature based"
control of your system
(remote controller
room thermostat is
installed)
88
88888888....88
starts
blinking
Push the ébi or ébj
Set desired leaving water
temperature (e.g. 65°C)
If the display is blank,
automatic leaving water
temperature is enabled
Push the y button
The 0 LED will light up and the
unit will start
For further details and advised
settings, see "Space heating
operation (hh
Display: "n"
button
hh
)" on page 4.
The remote controller
room thermostat
function is not installed
You have "leaving water
temperature based" control
of your system
Domestic water heating operation
Domestic water heating (only if domestic hot water tank option is installed)
Automatic storage (daily water heat-up, once during night and/or once during
day)
Tu rn on field setting [1-00]
and or [1-02] and then push
the rp button.
See "Automatic storage" on
page 7.
Manual storage (one time water heat-up)(refer to scheme below)
Push and hold the w button
for 5 seconds.
See "Manual storage" on
page 7.
Reheat (continuous, keeping the minimum water temperature)
Push the w button 1 time.
See "Reheat" on page 8.
The p icon will display.
Hot water will be produced at next scheduled
action.
When water heat-up starts, the w icon will
be blinking (1 second interval).
The w icon will start blinking (1 second
interval).
Hot water will be produced.
Hot water will be produced if the domestic hot
water tank temperature is below the selected
value.
Water will be heated up until the selected
value is reached.
Manual storage
Push and hold the w button for
Display: w icon starts blinkingDisplay: "n"
Your water will be heated till
storage set point (one time action)
For further details and advised
settings, see "Domestic water
heating operation (ww
PERATION
O
The remote controller offers full control over your installation. It can
control all heating applications which vary in capacity, electrical
supply and installed equipment (options). Operating the EKHBRD
unit comes down to operating the remote controller.
NOTE
page 6
OF
It is advised to use the remote controller, which
includes room thermostat function, delivered with the
unit.
This will prevent excessive space heating and will stop
the outdoor and indoor unit when the room
temperature is above the thermostat set point. Based
on the request from the user there is an immediate
feedback to the compressor control which optimizes
the performance.
Refer to the typical application examples in the indoor
installation manual for more details.
Never let the remote controller get wet. This may
cause an electric shock or fire.
Never press the buttons of the remote controller with a
hard, pointed object. This may damage the remote
controller.
Never inspect or service the remote controller
yourself, ask a qualified service person to do this.
Do not rinse the indoor unit. This may cause electric
shock or fire.
Do not climb, sit or stand on top of the unit.
Do not place any objects or equipment on the unit top
plate.
ww
)" on
THE
5 seconds
UNIT
The domestic hot water tank is not
installed
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system and options
4PW54466-1A
Operation manual
2
Page 4
1.
y
2.
0
3.
h, w, s
h
w
s
w
4.
e
6.
8
7.
p
8.
q
9.
x
k
l
ç
u
a
b
t
;
:
y
Remote controller buttons and icons
1356 228
21615
7
9
12
10
21
20
31
26
24
27
25
ON/OFF BUTTON
The ON/OFF button starts or stops the space heating.
Pressing the ON/OFF button consecutively too many times may
cause malfunction of the system (maximum 20 times per hour).
NOTE
OPERATION LED
The operation LED is lit during space heating operation. The
LED blinks if a malfunction occurs. When the LED is OFF, space
heating is inactive while the other operation modes can still be
active.
OPERATION MODE ICONS
These icons indicate the current operation mode(s): space
heating (
Within limits, different modes can be combined, e.g. space
heating and domestic water heating. The corresponding mode
icons will be displayed simultaneously.
If the domestic hot water tank is not installed, the
never be displayed.
EXTERNAL CONTROL ICON
This icon indicates that the outdoor unit is working in a forced
operation. As long as this icon is displayed, the remote controller
cannot be operated.
5.
DAY OF THE WEEK INDICATOR
This indicator shows the current day of the week.
When reading or programming the schedule timer, the indicator
shows the set day.
CLOCK DISPLAY
The clock display shows the current time.
When reading or programming the schedule timer, the clock
display shows the action time.
SCHEDULE TIMER ICON
This icon indicates that the schedule timer is enabled.
ACTION ICONS
These icons indicate the programming actions for each day of
the schedule timer.
OFF ICON
This icon indicates that the OFF action is selected when
programming the schedule timer.
10.INSPECTION REQUIRED
These icons indicate that inspection is required on the
installation. Consult your dealer.
Remark that pushing the
button has no
influence on the domestic water heating.
Domestic water heating is only switched on or off
by means of the
w button and/or disabling the
storage schedule timer.
), domestic water heating (
) or quiet mode (
1234567
and
4
14
19
17
11
18
13
32
23
30
29
28
icon will
11.TEMPERATURE DISPLAY
The display shows the current temperature of the installation
either leaving water temperature or actual room temperature.
When changing the room temperature set point, the set point will
be flashing for 5 seconds and then return to the actual room
temperature.
12.SETTING
$
Not used. For installation purposes only.
13.NOT AVAILABLE
n
This icon is displayed whenever a non-installed option is
addressed or a function is not available. A function not available
can mean insufficient permission level or can mean that a slave
remote controller is used (see installation manual).
Operation ON/OFF✔✔✔✔
Domestic water heating operation
ON/OFF
Setting the leaving water temperature✔✔✔—
Setting the room temperature✔✔✔✔
Quiet mode ON/OFF✔✔——
Weather dependent set point operation
ON/OFF
Setting the clock✔✔——
Programming the schedule timer✔———
Schedule timer operation ON/OFF✔—✔✔
Field settings✔———
Error code display✔✔✔✔
Test operation✔✔——
✔ = operable
14.DEFROST/START UP MODE ICON
This icon indicates that the defrost/start up mode is active.
15.COMPRESSOR ICON
This icon indicates that the compressor in the outdoor unit of the
).
installation is active.
16.PUMP ICON
é
This icon indicates that the circulation pump is active.
17.OUTDOOR TEMPERATURE DISPLAY
When this icon is flashing, the outdoor ambient temperature is
displayed. Refer to "Temperature read-out mode" on page 9 for
more information.
18.WEATHER DEPENDENT SET POINT ICON
This icon indicates that the controller will adapt the leaving water
temperature set point automatically, based on the outdoor
ambient temperature.
19.TEMPERATURE ICON
This icon is displayed when the actual room temperature or
room temperature set point are shown.
The icon is also displayed when the temperature set point is set
in schedule timer programming mode. Refer to "Temperature
read-out mode" on page 9 for more information.
20.TEST OPERATION ICON
This icon indicates that the unit runs in test mode.
21.FIELD SET CODE
This code represents the code from the field set list. Refer to the
"Field settings table" on page 15.
22.ERROR CODE
This code refers to the error code list and is for service purposes
only. Refer to the error code list in the installation manual.
9
Permission
MasterSlave
✔✔✔✔
✔✔✔—
d
level 2level 3
Operation manual
3
Indoor unit for air to water heat pump system and options
EKHBRD011~016AAV1+Y1
4PW54466-1A
Page 5
23. DOMESTIC WATER HEATING BUTTON w
This button enables or disables the different domestic hot water
modes in combination with the schedule timer button.
This button is not used when the domestic hot water tank is not
installed.
NOTE
Remark that pushing the y button has no
influence on the domestic water heating.
Domestic water heating is only switched on or off
by means of the w button and/or disabling the
storage schedule timer.
24. WEATHER DEPENDENT SET POINT BUTTON ba
This button enables or disables the weather dependent set point
function which is available in space heating operation.
If the controller is set to permission level 3 (refer to "Field
settings" in the installation manual), the weather dependent set
point button will not be operable.
25. INSPECTION/TEST OPERATION BUTTON z
This button is used for installation purposes and changing field
settings. Refer to "Field settings" on page 14.
26. PROGRAMMING BUTTON <
This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.
27. SCHEDULE TIMER BUTTON r/p
The main function of this multi-purpose button is to
enable/disable the schedule timer.
The button is also used to set the clock and to program the
controller. The function of the button depends on the actual
status of the controller or on previous actions carried out by the
operator.
28. TIME ADJUST BUTTONS pi and pj
These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (water inlet/outlet temperature of
the indoor unit, outdoor ambient temperature, actual room
temperature and domestic hot water temperature) and in
schedule timer programming mode.
29. LEAVING WATER TEMPERATURE ADJUST BUTTONS
ébi and ébj
These buttons are used to adjust the leaving water temperature
set point in normal operation mode or in schedule timer
programming mode.
If the controller is set to permission level 3 (refer to "Field
settings" in the installation manual), the leaving water
temperature adjust button will not be operable.
In case the weather dependent set point operation is selected,
the unit has a floating set point. In this case, the a icon as well
as the shift value (in case not zero) will display.
30. ROOM TEMPERATURE ADJUST BUTTONS bi and bj
These multi-purpose buttons are used to adjust the current room
temperature set point in normal operation mode or in schedule
timer programming mode.
When changing the room temperature set point, the set point
value on the display will be flashing. After 5 seconds the display
will show to the actual room temperature.
31. QUIET MODE BUTTON
s
This button enables or disables quiet mode.
If the controller is set to permission level 2 or 3 (refer to "Field
settings" in the installation manual), the quiet mode button will
not be operable.
32. The
= button has no function.
Setting the clock
After initial installation, the user can set the clock and day of the week.
The remote controller is equipped with a schedule timer that enables
the user to schedule operations. Setting the clock and day of the
week is required to be able to use the schedule timer.
1Hold down the pr button for 5 seconds.
The clock read-out and the day of week indicator start flashing.
2Use the pi and pj buttons to adjust the clock.
Each time the pi or pj button is pressed, the time will
increase/decrease by 1 minute. Keeping the pi or pj
button pressed will increase/decrease the time by 10 minutes.
3Use the ébi or ébj button to adjust the day of the week.
Each time the ébi or ébj button is pressed the next or
previous day is displayed.
4Press the < button to confirm the current set time and day of the
week.
To leave this procedure without saving, press the pr button.
If no button is pressed for 5 minutes the clock and day of the
week will return to their previous setting.
NOTE
■The clock needs to be set manually. Adjust the
setting when switching from summertime to
wintertime and vice versa.
■If the controller is set to permission level 2 or 3
(refer to "Field settings" in the installation
manual), setting the clock will not be possible.
■A power failure exceeding 1 hour will reset the
clock and the day of the week. The schedule timer
will continue operation, but with a disordered
clock. Therefor it will be needed to correct the
clock and the day of the week.
Space heating operation (h)
Space heating operation can be controlled on two different ways:
- based on room temperature,
- based on leaving water temperature.
The purpose of each operation and how the configuration is done, is
explained below.
Room temperature control
In this mode, heating will be activated as required by the room
temperature set point. The set point can be set manually or through
the schedule timer.
NOTE
When using room temperature control, space heating
operation based on room temperature will have priority
over leaving water control.
Note that it is possible that the leaving water
temperature becomes higher than the set point if the
unit is controlled by room temperature.
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system and options
4PW54466-1A
Operation manual
4
Page 6
Selecting space heating operation
1Use the y button to switch ON/OFF space heating (h).
Icon h appears on the display as well as the corresponding
water temperature set point.
The operation LED 0 lights up.
2Use the bi and bj buttons to set the desired room
temperature.
Temperature range for heating: 16°C~32°C (room temperature)
In order to avoid overheating, space heating is not operable
when the outdoor ambient temperature rises above a certain
temperature (see operation range).
Refer to "Programming and consulting the schedule timer" on
page 11 for setup of the schedule timer function.
3Use the ébi and ébj buttons to select the leaving
water temperature which you want to be used to heat up your
system (for detailed information see "Leaving water temperature
control" on page 5).
Automatic setback function
Setback function provides the possibility to lower the room
temperature. The setback function can for instance be activated
during the night because the temperature demands during night and
day are not the same.
NOTE
■Remark that the b icon will be flashing during
setback operation.
■By default the setback function is enabled.
■The setback function can be combined with the
automatic weather dependent set point operation.
■Setback function is an automatic daily scheduled
function.
The setback function is configured through field settings. Refer to the
chapter "Field settings" on page 14 for a detailed description how to
set one or more field settings.
■[2-00] Status: defines whether the setback function is turned ON
(1) or OFF (0)
■[2-01] Start time: time at which setback is started
■[2-02] Stop time: time at which setback is stopped
■[5-03] Room setback temperature
T
A
21°C
[5-03] 18°C
t
[2-01][2-02]
ANormal room temperature set point
tTime
TTemperature
NOTE
While room temperature setback function is active,
leaving water setback operation is also performed (see
"Leaving water temperature control" on page 5).
Pay attention not to set the setback value too low,
especially during colder periods (e.g. winter time). It is
possible that the room temperature can not be reached (or
it will take a much longer time) because of the big
temperature difference.
Leaving water temperature control
In this mode, heating will be activated as required by the water
temperature set point. The set point can be set manually, through the
schedule timer or weather dependent (automatic).
Selecting space heating operation
1Use the y button to switch ON/OFF space heating (h).
Icon h appears on the display as well as the corresponding
water temperature set point.
The operation LED 0 lights up.
2Use the ébi and ébj buttons to set the desired leaving
water temperature.
Temperature range for heating: 25°C~80°C (leaving water
temperature)
In order to avoid overheating, space heating is not operable
when the outdoor ambient temperature rises above a certain
temperature (see operation range).
Refer to "Remote controller schedule timer" for setup of the schedule
timer function.
NOTE
Selecting weather dependent set point operation
When weather dependent operation is active, the leaving water
temperature is determined automatically depending on the outdoor
temperature: colder outdoor temperatures will result in warmer water
and vice versa. The unit has a floating set point. Activating this
operation will result in a lower power consumption than use with a
manually fixed leaving water set point.
During weather dependent operation, the user has the possibility to
shift up or down the target water temperature by a maximum of 5°C.
This shift value is the temperature difference between the
temperature set point calculated by the controller and the real set
point. E.g. a positive shift value means that the real temperature set
point will be higher than the calculated set point.
It is advised to use the weather dependent set point because it
adjusts the water temperature to the actual needs for space heating.
It will prevent the unit from switching too much between thermo ON
operation and thermo OFF operation when using the remote
controller room thermostat or external room thermostat.
NOTE
1Press the ba button 1 time to select weather dependent set
2Use the ébi and ébj buttons to set the shift value.
3Press the ba button to deactivate weather dependent set point
■When an external room thermostat is installed,
the thermo ON/OFF is determined by the external
room thermostat. The remote controller is than
operated in the leaving control mode and is not
functioning as a room thermostat.
■The remote controller ON/OFF status always has
priority over the external room thermostat!
During this operation, instead of showing the water
temperature set point, the controller shows the shift
value which can be set by the user.
point operation (or 2 times when the remote controller room
thermostat function is used).
Icon a appears on the display as well as the shift value. The
shift value is not shown in case it is 0.
Range for the shift value: –5°C to +5°C
Icon a will be displayed as long as the weather dependent set
point operation is enabled.
operation.
The ébi and ébj buttons are used to set the leaving
water temperature.
Operation manual
5
Indoor unit for air to water heat pump system and options
EKHBRD011~016AAV1+Y1
4PW54466-1A
Page 7
Field settings define the parameters for the weather dependent
operation of the unit. Refer to the chapter "Field settings" on page 14
for a detailed description how to set one or more field settings.
T
t
Lo_Ti
+ 05
Shift value
Hi_Ti
Lo_AHi_AT
T
Target water temperature
t
T
Ambient (outdoor) temperature
A
= Shift value
00
– 05
A
■[3-00] Low ambient temperature (Lo_A): low outdoor
temperature.
■[3-01] High ambient temperature (Hi_A): high outdoor
temperature.
■[3-02] Set point at low ambient temperature (Lo_Ti): the target
outgoing water temperature when the outdoor temperature
equals or drops below the low ambient temperature (Lo_A).
Note that the Lo_Ti value should be higher than Hi_Ti, as for
colder outdoor temperatures (i.e. Lo_A) warmer water is required.
■[3-03] Set point at high ambient temperature (Hi_Ti): the target
outgoing water temperature when the outdoor temperature
equals or rises above the high ambient temperature (Hi_A).
Note that the Hi_Ti value should be lower than Lo_Ti, as for
warmer outdoor temperatures (i.e. Hi_A) less warm water
suffices.
NOTE
If by mistake the value of [3-03] is set higher than the
value of [3-02], the value of [3-03] will always be used.
Automatic setback function
Setback function provides the possibility to lower the room
temperature. The setback function can for instance be activated
during the night because the temperature demands during night and
day are not the same.
NOTE
■Remark that the b icon will be flashing during
setback operation.
■By default the setback function is enabled.
■The setback function can be combined with the
automatic weather dependent set point operation.
■Setback function is an automatic daily scheduled
function.
The setback function is configured through field settings. Refer to the
chapter "Field settings" on page 14 for a detailed description how to
set one or more field settings.
■[2-00] Status: defines whether the setback function is turned ON
(1) or OFF (0)
■[2-01] Start time: time at which setback is started
■[2-02] Stop time: time at which setback is stopped
■[5-02] Leaving water setback temperature (temperature drop)
T
65°C
A
5°C [5-02]
60°C
B
t
[2-01][2-02]
ANormal leaving water temperature set point
BLeaving water temperature, including the leaving water setback
temperature
tTime
TTemperature
Domestic water heating operation (w)
NOTE
For the domestic water heating mode, several operations are
possible:
The purpose of each operation, and how the configuration is done, is
explained below.
Domestic water heating modes
T
D
E
F
G
Any domestic water heating operation is impossible
when the domestic hot water tank is not installed.
• storage operation (either automatic or manually set)
DDisinfection operation temperature [5-00] (e.g. 70°C)
EHot water storage temperature [b-03] (e.g. 60°C)
FReheat maximum water temperature [b-01] (e.g. 45°C)
GReheat minimum water temperature [b-00] (e.g. 35°C)
tTime
TDomestic hot water tank temperature
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system and options
4PW54466-1A
Operation manual
6
Page 8
Automatic storage
In this mode, the indoor unit will deliver hot water to the domestic hot
water tank based on the daily fixed pattern. This mode will continue
until the storage temperature set point is reached. During operation
of this mode, the w icon will be blinking with 1 second intervals.
Automatic storage is the recommended domestic hot water mode. In
this mode, water heats up during the night (when space heating
requirements are lower) until the storage temperature set point is
reached. The heated water is stored in the domestic hot water tank at
a higher temperature so it can fulfil the domestic hot water
requirements throughout the day.
NOTE
Remark that the w icon will only be blinking during
effective automatic storage operation. Presence of the
permanently lit w icon does not mean that automatic
storage is enabled, but only means that reheat is
enabled.
During operation it is always possible to cancel the
operation by pushing the w button once.
Be aware that after pushing the w button, it is possible
that the permanently lit w icon still displays.
The storage temperature set point and the timing are field settings.
Refer to the chapter "Field settings" on page 14 for a detailed
description how to set one or more field settings.
■[1-00] Status: defines whether the domestic water heating
(storage mode) during night is enabled (1) or not (0).
■[1-01] Start time: time of the night at which the domestic water
should be heated.
■[1-02] Status: defines whether the domestic water heating
(storage mode) during daytime is enabled (1) or not (0).
■[1-03] Start time: time of the day at which the domestic water
should be heated.
Be aware that despite the automatic storage is a
pre-programmed schedule timer, it is only active when the
schedule timer is enabled. This means that you have to
push the rp button and confirm that the p is displayed to
make sure that the automatic storage will operate.
■[b-03] set point: storage temperature (see figure "Domestic
water heating modes" on page 6).
■[b-02] Status: defines whether the weather dependent domestic
water heating is turned ON (1) or OFF (0).
If enabled, the storage set point will be set weather dependent.
In case of a higher ambient temperature (e.g. during summertime), temperature of supply water to the domestic hot water
tank will be higher too, so that storage temperature set point can
be set lower in order to keep the overall equivalent hot water
amount the same during the whole year. Therefor it is
recommended to use this function.
T
70°C
55°C
NOTE
■Make sure the domestic hot water is only heated
up to the domestic hot water temperature you
require.
Start with a low domestic hot water storage
temperature set point, and only increase if you
feel that the domestic hot water supply
temperature is not sufficient for your needs (this
depends on your water using pattern).
■Make sure the domestic hot water is not heated
unnecessary. Start with activating automatic
storage during night (default setting). If it seems
that the domestic hot water night storage
operation is not sufficient for your needs, an
additional storage during daytime can be set.
■For energy-saving purposes, it is advised to
enable the weather dependent domestic water
heating.
Manual storage
This mode is to be selected manually and will make the indoor unit
immediately deliver hot water to the domestic hot water tank. This
mode will continue until the storage temperature set point is reached.
It is a one-time hot water making feature.
Selecting manual storage operation for domestic water heating
1Push and hold the w button for 5 seconds to activate manual
storage operation.
The w icon will start blinking with 1 second intervals.
NOTE
Remark that the w icon will only be blinking
during effective operation.
During the operation it is always possible to
cancel the operation by pushing the w button
once.
Be aware that after pushing the w button, it is
possible that the permanently lit w icon still
displays, meaning that the reheat function is
enabled.
The storage temperature set point is a field setting. Refer to the
chapter "Field settings" on page 14 for a detailed description how to
set one or more field settings.
■[b-03] Set point: storage temperature (see figure "Domestic
water heating modes" on page 6).
■[b-02] Status: defines whether the weather dependent domestic
water heating is turned ON (1) or OFF (0).
If enabled, the storage set point will be set weather dependent.
In case of a higher ambient temperature (e.g. during summertime), temperature of supply water to the domestic hot water
tank will be higher too, so that storage temperature set point can
be set lower in order to keep the overall equivalent hot water
amount the same during the whole year. Therefor it is
recommended to use this function.
T
70°C
15°C25°C
AAmbient temperature
TDomestic hot water storage temperature
NOTE
The temperatures for weather dependent domestic
water heating (see figure) are fixed and can not be
changed.
Operation manual
7
A
55°C
A
15°C25°C
AAmbient temperature
TDomestic hot water storage temperature
NOTE
The temperatures for weather dependent domestic
water heating (see figure) are fixed and can not be
changed.
Indoor unit for air to water heat pump system and options
EKHBRD011~016AAV1+Y1
4PW54466-1A
Page 9
Manual storage is deactivated automatically when the set point for
the domestic hot water storage temperature is reached. It can also be
stopped at any time by pushing the w button.
Reheat
This mode will prevent the domestic hot water from cooling down
lower than a certain temperature. When enabled the indoor unit will
deliver hot water to the domestic hot water tank when the reheat
minimum value is reached. The domestic water heating will continue
until the reheat maximum temperature is reached.
Selecting reheat operation for domestic water heating
1Use the w button to enable reheat operation.
The w icon will display.
NOTE
Remark that the w icon will be continuously lit as
long as the reheat function is enabled. It is not
possible to see when the indoor unit is reheating
the domestic hot water tank.
2Press the w button again to disable reheat operation.
The w icon disappears.
The reheat minimum and reheat maximum temperature set points
are field settings. Refer to the chapter "Field settings" on page 14 for
a detailed description how to set one or more field settings.
■[b-00] Set point: reheat minimum temperature (see figure
"Domestic water heating modes" on page 6).
■[b-01] Set point: reheat maximum temperature (see figure
"Domestic water heating modes" on page 6).
NOTE
Remark that pushing the y button has no influence
on the domestic water heating. Domestic water
heating is only switched on or off by means of the w
button and/or disabling the storage schedule timer.
Disinfection operation
This mode will disinfect the domestic hot water tank by periodically
heating the domestic water to a specific temperature. During the
operation of this mode the w icon will be blinking rapidly with 0.5
second intervals.
Other operation modes
Start up operation (d)
During start up, the d icon displays, indicating that the heat
pump is starting up and is not working in a steady state condition.
Defrost operation (d)
In space heating operation or domestic water heating operation,
freezing of the outdoor heat exchanger may occur due to low outdoor
temperature. If this risk occurs, the system goes into defrost
operation. It reverses the cycle and takes heat from the indoor
system to prevent freezing of the outdoor system. After a maximum
of 12 minutes of defrost operation, the system returns to space
heating operation.
Quiet mode operation (s)
Quiet mode operation means that the indoor unit works at reduced
compressor speed so that the noise produced by the indoor unit
drops. This implies that it will take longer till the required temperature
set point is reached. Beware of this when a certain level of heating is
required indoors.
Selecting quiet mode operation
1Use the s button to activate quiet mode operation.
The s icon displays.
If the controller is set to permission level 2 or 3 (refer to "Field
settings" in the installation manual), the s button is not
operable.
2Press the s button again to deactivate quiet mode operation.
The s icon disappears.
There are 3 different levels of quiet mode operation. The desired
quiet mode is set through a field setting. Refer to the chapter "Field
settings" on page 14 for a detailed description how to set one or more
field settings.
■[8-03] Status: defines the level of low noise operation (quiet
mode).
NOTE
Remark that the w icon will only be blinking during
effective operation.
During the operation it is always possible to cancel the
disinfection function by pushing the w button once.
Be aware that after pushing the w button, it is possible
that the permanently lit w icon still displays, meaning
that the reheat function is enabled.
NOTE
If a domestic hot water tank is installed, the disinfection
function is enabled by default.
The disinfection temperature set point is a field setting as are the
retention time, day and hour. Refer to the chapter "Field settings" on
page 14 for a detailed description how to set one or more field
settings.
■[4-00] Status: defines whether the disinfection function is turned
ON (1) or OFF (0).
■[4-01] Operation interval: day of the week at which the domestic
water should be heated.
■[4-02] Start time: time at which the disinfection operation is
started.
■[5-00] Set point: Disinfection water temperature to be reached
(see figure "Domestic water heating modes" on page 6).
■[5-01] Duration: time period defining how long the disinfection
set point temperature should be maintained.
Even if all schedule timers are de-activated and there is no reheat
function active, the disinfection function will operate if a domestic hot
water tank is installed and field setting [4-00] is set to ON.
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system and options
4PW54466-1A
Operation manual
8
Page 10
Simultaneous demand of space heating and domestic
water heating
The unit can not perform domestic water heating and space heating
at the same time. If both modes are requested at the same time, the
unit will heat up till the reheat maximum temperature in 1 time. During
this period, space heating is not possible.
■If you are using the remote controller room temperature control:
When the reheat temperature is reached, the further heat up of
the domestic hot water tank will be decided by the remote
controller room thermostat in order to prevent the room
temperature to drop too much.
■If you are using the external room thermostat:
When the reheat temperature is reached, the further heat up of
the domestic hot water tank will be decided by the external room
thermostat thermo conditions and running timers which are
programmed by your installer.
■If you are using the remote controller leaving water temperature
control:
When the reheat temperature is reached, the further heating up
of the domestic hot water tank will be decided by the running
timers which are programmed by your installer.
T
A
B
t
AStorage temperature
BReheat maximum temperature
tTime
TDomestic hot water storage temperature
Temperature read-out mode
On the remote controller, the actual temperatures can be displayed.
1Push and hold the ba button for 5 seconds.
The leaving water temperature is displayed (icons l and =
and é are blinking).
2Use the pi and pj buttons to display:
• The entering water temperature (icons l and = are
blinking and the é icon is flashing slowly).
• The indoor temperature (icons l and = are blinking).
• The outdoor temperature (icons l and u are blinking).
• The hot water supply tank temperature (icons l and w are
blinking).
3Push the ba button again to leave this mode. If no button is
pressed, the remote controller leaves the display mode after 10
seconds.
Schedule timer operation
In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.
The schedule timer is enabled (p icon displayed) or disabled (p icon
not displayed) by pressing the pr button.
Space heating
Refer to "Programming space heating" on page 12.
Five actions per day of the week can be programmed, totalling 35
actions.
The space heating schedule timer can be programmed in 2 different
ways: based on the temperature set point (both leaving water
temperature and room temperature) and based on the ON/OFF
instruction.
The desired method is set through field setting. Refer to the chapter
"Field settings" on page 14 for a detailed description how to set one
or more field settings.
■[0-03] Status: defines whether ON/OFF instruction can be used
in the schedule timer for space heating.
NOTE
In the following tables both methods on how to interpret the schedule
timer are shown.
Method 1Space heating based on temperature set point
During operation During schedule timer operation the operation LED is lit
When pushing
the y button
When pushing
the r/p button
By default space heating based on temperature set
point (method 1) is enabled, so only temperature shifts
are possible (no ON/OFF instruction).
Advantage of this method is that you can simply switch
off the space heating operation by pushing the y
button without disabling the automatic domestic hot
water storage operation (e.g. during summertime
when no space heating is required).
(a)
continuously.
The schedule timer for space heating will stop and will
not start again.
The controller will be switched off (operation LED will
stop working).
However, the schedule timer icon will stay displayed
which means that the domestic water heating stays
enabled.
The schedule timer for space heating and domestic
water heating along with the quiet mode will be stopped
and will not start again.
The schedule timer icon will not be displayed anymore.
(a) For leaving water temperature and/or room temperature
Operation manual
9
Indoor unit for air to water heat pump system and options
EKHBRD011~016AAV1+Y1
4PW54466-1A
Page 11
Operation example: Schedule timer based on temperature set
19
21
62
64
57
5:00
23:00
19
21
62
60
62
65
64
19
62
19
62
19
62
60
60
5:00
23:00
19
22
21
62
65
64
19
21
62
60
points.
When setback function is enabled, the setback operation will have
priority over the scheduled action in the schedule timer.
T
2222°C
22°C
6565°C
1
19
°C1919°C1919°C
19°C19°C19°C
°C6262°C6262°C
62°C62°C
62
65°C
62°C
21
21°C
64
64°C
°C
°C
t
16:00
0:30
6:309:00
T
2
18°C
1818°C
60
°C60°C
°C57°C
23:00
57
5:00
5:0023:00
A
t
T
2222°C
22°C
°C
65
3
19
19°C
62°C62°C
62
1Schedule timer
2Setback function
3When both setback function and schedule timer are enabled
ASetback function
tTime
TTemperature set point
65°C
°C
°C
16:00
Room temperature
Leaving water temperature
60
60°C
23:00
°C
0:30
1818°C
18°C
5757°C57°C
21
21°C
°C
°C
64
64°C
°C
°C
19
19°C
19
19°C
62
62
°C
62°C
°C
62°C
5:009:00
6:30
1919°C
19°C
19
19°C
62
62°C
62
°C
°C
°C
t
Operation example: Schedule timer based on ON/OFF instruction.
When setback function is enabled, the setback operation will have
priority over the scheduled action in the schedule timer if ON
instruction is active. If OFF instruction is active this will have priority
over the setback function. At any time the OFF instruction will have
the highest priority.
B
°C
22
22°C
°C
65
1
19°C19°C
19
62
62°C62°C
65°C
°C1919°C
°C6262°C
OFFONON
21
°C
21°C
64
°C
64°C
t
9:00
16:00
1818°C
23:00
18°C
60
A
2
B
2222°C
22°C
6565°C
65°C
°C1919°C
19°C19°C
19
°C6262°C
62
62°C62°C
3
16:00
1Schedule timer
2Setback function
3When both setback function and schedule timer are enabled
ASetback function
BON/OFF instruction
tTime
TTemperature set point
Room temperature
Leaving water temperature
23:00
18°C
1818°C
60
°C60°C
6:300:30
°C60°C
5:00
5:0023:00
t
OFFONON
°C
21
21°C
6464°C
64°C
t
6:309:00
Method 2Space heating based on ON/OFF instruction
During operation When the schedule timer switches space heating OFF,
When pushing
the y button
When pushing
the r/p button
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system and options
4PW54466-1A
the controller will be switched off (operation LED will stop
working). Note that this has no influence on the domestic
water heating.
The schedule timer for space heating will stop (when
active at that moment) and will start again at the next
scheduled ON function.
The "last" programmed command overrules the
"preceding" programmed command and will remain
active until the "next" programmed command occurs.
So in order to know the actual setting, one should consult
the last programmed command. It is clear that the "last"
programmed command may date from the day before.
Refer to "Consulting programmed actions" on page 13.
The controller will be switched off (operation LED will
stop working).
However the schedule timer icon will stay displayed
which means that the domestic heating stays enabled.
The schedule timer for space heating and domestic
water heating along with the quiet mode will be stopped
and will not start again.
The schedule timer icon will not be displayed anymore.
Example: imagine the actual time is 17:30 and actions
are programmed at 13:00, 16:00 and 19:00. The "last"
programmed command (16:00) overruled the
"previous" programmed command (13:00) and will
remain active until the "next" programmed command
(19:00) occurs.
Operation manual
10
Page 12
Domestic water heating
Domestic water heating can be done through several standard
operation modes:
•Automatic storage: by field setting, once during night and/or
once during the afternoon the water is heated till storage set
point.
• Manual storage: if due to special circumstances, production
of hot water (till storage set point) is needed immediately
(1 time), this function can be used.
• Reheat: the reheat function can be activated next to or
separate from the automatic storage operation if the user
wants to keep the domestic hot water tank at the minimum
reheat temperature.
Next to the standard domestic water heating operation modes, it is
also possible to freely program the domestic water heating operation
through the schedule timer (refer to "Programming quiet mode or
domestic water heating" on page 13). Then the mode is switched on
or off at a scheduled time. Five actions can be programmed per
mode. These actions are repeated daily (additional schedule of
storage on top of the automatic day and night storage functionality).
NOTE
■Remark that only the time when domestic water
heating must start and stop can be programmed
in the schedule timer. When domestic water
heating is enabled, the water will be heated till
storage set point. The storage set point is set
through field setting.
■For energy-saving reasons, keep hours with low
electricity cost tariffs in mind when programming
the schedule timer for domestic water heating.
Quiet mode
Refer to "Programming quiet mode or domestic water heating" on
page 13.
Switch the mode on or off at a scheduled time. Five actions can be
programmed per mode. These actions are repeated daily.
Programming and consulting the schedule timer
Programming the schedule timer is flexible (you can add, remove or
alter programmed actions whenever required) and straightforward
(programming steps are limited to a minimum). However, before
programming the schedule timer, remind:
■Familiarize yourself with the icons and the buttons. You will need
them when programming. Refer to "Remote controller buttons
and icons" on page 3.
■Fill out the form at the very end of this manual. This form can
help you define the required actions for each day. Keep in mind
that:
- In the space heating program, 5 actions can be programmed
per weekday. The same actions are repeated on a weekly
basis.
- In the domestic water heating and quiet mode program, 5
actions can be programmed per mode. The same actions are
repeated on a daily basis.
■Ta ke your time to enter all data accurately.
■Tr y to program the actions in a chronological way: start with
action 1 for the first action and end with the highest number for
the last action. This is not a requirement but will simplify the
interpretation of the program later.
■If 2 or more actions are programmed for the same day and at the
same time, only the action with the highest action number will be
executed.
■If the auto restart function is disabled, the
schedule timer will not be activated when power
returns to the unit after a power supply failure.
Press the pr button to enable the schedule timer
again.
■When power returns after a power supply failure,
the auto restart function reapplies the user
interface settings at the time of the power supply
failure (if time is shorter than 2 hours). It is
therefore recommended to leave the auto restart
function enabled.
■The programmed schedule is time driven.
Therefore, it is essential to set the clock and the
day of the week correctly.
Refer to "Setting the clock" on page 4.
■When the schedule timer is not enabled (p icon
not displayed), schedule timer actions will not be
executed!
■The programmed actions are not stored according
to their timing but according to the time of
programming. This means that the action that was
programmed first gets action number 1, even
though it is executed after other programmed
action numbers.
■You can always alter, add or remove the programmed actions
later.
Operation manual
11
Indoor unit for air to water heat pump system and options
EKHBRD011~016AAV1+Y1
4PW54466-1A
Page 13
Programming space heating
5 sec
5 sec
Programming space heating is carried out as follows:
NOTE
Returning to previous steps in the programming
procedure without saving modified settings is done by
pressing the pr button.
1Press the < button to enter the programming/consulting mode.
2Select the operation mode you would like to program by means
of the pi and pj buttons.
The actual mode is blinking.
3Press the < button to confirm the selected mode.
The actual day is blinking.
4Select the day you would like to consult or to program by means
of the pi and pj buttons.
The selected day is blinking.
5Press the < button to confirm the selected day.
6Hold down the < button for 5 seconds to program the detailed
actions.
The first programmed action of the selected day appears.
7Use the < button to select the action number you would like to
program or to modify.
8Use the pi and pj buttons to set the correct action time.
9Use the ébi and ébj buttons to set the leaving water
temperature.
10 Use the bi and bj buttons to set the room temperature.
11 Use the ba button to select:
- x: to switch heating and the remote controller off.
- a: to select automatic temperature calculation for leaving
water temperature
Use the ébi and ébj buttons to set the appropriate
shift value (refer to "Space heating operation (h)" on page 4 for
more information about weather dependent set point).
12 Repeat steps 7 to 10 to program the other actions of the
selected day.
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
13 Press the < button for 5 seconds to store the programmed
actions.
If the < button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 and 5 are deleted.
You automatically return to step 6.
By pressing the pr button several times, you return to previous
steps in this procedure and finally return to normal operation.
14 You automatically return to step 6, start again to program the
following day.
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system and options
4PW54466-1A
Operation manual
12
Page 14
Programming quiet mode or domestic water heating
11 Press the < button for 5 seconds to store the programmed
actions.
If the < button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 and 5 are deleted.
By pressing the pr button several times, you return to previous
steps in this procedure and finally return to normal operation.
12 You automatically return to step 6, start again to program the
following day.
Consulting programmed actions
Consulting space heating, domestic water heating or quiet mode is
carried out as follows:
Programming domestic water heating or quiet mode is carried out as
follows:
NOTE
Returning to previous steps in the programming
procedure without saving modified settings is done by
pressing the pr button.
1Press the < button to enter the programming/consulting mode.
2Select the operation mode you would like to program by means
of the pi and pj buttons.
The actual mode is blinking.
3Press the < button to confirm the selected mode.
4Select the day you would like to program by means of the pi
and pj buttons.
The actual day is blinking.
5Press the < button to confirm the selected day.
6Hold down the < button for 5 seconds to the program the
detailed actions
The first programmed action of the selected day appears.
7Use the < button to select the action number you would like to
program or to modify.
8Use the pi and pj buttons to set the correct action time.
9Use the ba button to select or deselect x as action.
10 Repeat steps 7 to 10 to program the other actions of the
selected mode.
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
NOTE
Returning to previous steps in this procedure is done
by pressing the pr button.
1Press the < button to enter the programming/consulting mode.
2Select the operation mode you would like to consult by means of
the pi and pj buttons.
The actual mode is blinking.
3Press the < button to confirm the selected mode.
The actual day is blinking.
4Select the day you would like to consult by means of the pi
and pj buttons.
The selected day is blinking.
5Press the < button to confirm the selected day.
The first programmed action of the selected day appears.
6Use the pi and pj buttons to consult the other
programmed actions of that day.
This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.
By pressing the pr button several times, you return to previous
steps in this procedure and finally return to normal operation.
Tips and tricks
Programming the next day(s)
After confirming the programmed actions of a specific day (i.e. after
pressing the < button for 5 seconds), press the pr button once. You
can now select another day by using the pi and pj buttons
and restart consulting and programming.
Copying programmed actions to next day
In space heating program it is possible to copy all programmed
actions of a specific day to the next day (e.g. copy all programmed
actions from "1" to "2").
To copy programmed actions to the next day, proceed as follows:
1Press the < button to enter the programming/consulting mode.
The actual mode is blinking.
2Select the operation mode you would like to program by means
of the pi and pj buttons.
The actual mode is blinking.
You can leave programming by pressing the pr button.
3Press the < button to confirm the selected mode.
The actual day is blinking.
4Select the day you would like to copy to the next day by means
of the pi and pj buttons.
The selected day is blinking.
You can return to step 2 by pressing the pr button.
5Press the < and pr buttons simultaneously for 5 seconds.
After 5 seconds the display will show the next day (e.g. "2" if "1"
was selected first). This indicates that the day has been copied.
You can return to step 2 by pressing the pr button.
Operation manual
13
Indoor unit for air to water heat pump system and options
EKHBRD011~016AAV1+Y1
4PW54466-1A
Page 15
Deleting one or more programmed actions
Deleting one or more programmed actions is done at the same time
as storing the programmed actions.
When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the < button for 5 seconds, you store all actions except
those with a higher action number than the one that is displayed.
E.g. when the < button is pressed when action number 3 is
displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.
Deleting a mode
1Press the < button to enter the programming/consulting mode.
2Select the operation mode you would like to delete by means of
the pi and pj buttons.
The actual mode is blinking.
3Press the < and ba button simultaneously for 5 seconds to
delete the selected mode.
Deleting a day of the week
<
1Press the
button to enter the programming/consulting mode.
2Select the operation mode you would like to delete by means of
the pi and pj buttons.
The actual mode is blinking.
3Press the < button to confirm the selected mode.
The actual day is blinking.
4Select the day you would like to delete by means of the pi
and pj buttons.
The selected day is blinking.
5Press the < and ba button simultaneously for 5 seconds to
delete the selected day.
Field settings
The configuration of the Daikin system is done through field settings.
In this operation manual all field settings related to the operation of
the unit and user demand are explained. A list of all those field
settings and default values is given under "Field settings table" on
page 15. In this same list, we provided for 2 columns to register the
date and value of altered field settings at variance with the default
value.
For a total list of field settings, refer to the installation manual.
All field settings are accessible and programmable through the user
interface on the indoor unit.
Each field setting is assigned a 3-digit number or code, for example
[5-03], which is indicated on the user interface display. The first digit
[5] indicates the 'first code' or field setting group. The second and
third digit [03] together indicate the 'second code'.
Procedure
To change one or more field settings, proceed as follows.
3
2
1
Operating the remote alarm option
An optional EKRP1HBA digital I/O PCB can be connected to the
indoor unit and be used to remotely monitor your system. This
address card offers 3 voltage free outputs:
■Output 1 = THERMO ON/OFF
this output will be enabled when your unit is in space heating
operation.
■Output 2 = ALARM OUTPUT
this output will be enabled when your unit is in error condition.
■Output 3 = DOMESTIC HOT WATER MODE ON/OFF
this output will be enabled when your unit is in domestic water
heating operation.
For more details about the wiring connections of this option, refer to
the wiring diagram of the unit.
Operating the optional remote controller
If besides the main remote controller the optional remote controller is
installed as well, the main remote controller (master) can access all
settings while the second remote controller (slave) can not access
schedule settings and parameter settings.
Refer to the installation manual for more details.
1Press the z button for a minimum of 5 seconds to enter FIELD
SET MODE.
The $ icon (3) will be displayed. The current selected field
setting code is indicated ; (2), with the set value displayed to
the right - (1).
2Press the ébi button to select the appropriate field setting
first code.
3Press the ébj button to select the appropriate field setting
second code.
4Press the pfi button and pfj button to change
the set value of the select field setting.
5Save the new value by pressing the pr button.
6Repeat step 2 through 4 to change other field settings as
required.
7When finished, press the z button to exit FIELD SET MODE
NOTE
Changes made to a specific field setting are only
.
stored when the pr button is pressed. Navigating to a
new field setting code or pressing the z button will
discard the change made.
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system and options
4PW54466-1A
NOTE
■Before shipping, the set values have been set as
shown under "Field settings table" on page 15.
■When exiting FIELD SET MODE, "88" may be
displayed on the remote controller LCD while the
unit initializes itself.
Operation manual
14
Page 16
NOTE
When running through the field settings you may
notice that there are some more field settings as there
are mentioned in the "Field settings table" on page 15.
These field settings are not applicable and may not
be changed!
Field settings table
First
Second
code
code
Setting name
0Remote control setup
03Status : space heating schedule timer mode1 (ON)0/1——
1Automatic storage timing for domestic water heating
00Status: night time storage1 (ON)0/1——
01Night time storage start time1:000:00~23:001:00hour
02Status: day time storage0 (OFF)0/1——
03Day time storage start time15:000:00~23:001:00hour
Indoor unit for air to water heat pump system and options
EKHBRD011~016AAV1+Y1
4PW54466-1A
Page 17
MAINTENANCE
Maintenance activities
In order to ensure optimal availability of the unit, a number of checks
and inspections on the unit and the field wiring have to be carried out
at regular intervals, preferably yearly. This maintenance should be
carried out by your local Daikin technician (see installation manual).
The only maintenance which may be required by the operator is:
■keeping the remote controller clean by means of a soft damp
cloth,
■checking if the water pressure indicated on the manometer is
above 1 bar.
If the supply cord is damaged, it must be replaced by the
manufacturer, its agent or similar qualified persons in order
to avoid hazards.
During longer periods of standstill, e.g. during summer with
a heating only application, it is very important NOT TO
SWITCH OFF THE POWER SUPPLY towards the unit.
Switching off the power supply stops the automatic
repetitive movement of the pump in order to prevent it from
getting jammed.
Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.
Refrigerant type:R134a
(1)
value:1300
GWP
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.
TROUBLESHOOTING
The guidelines below might help to solve your problem. If you cannot
solve the problem, consult your installer.
POSSIBLECAUSESCORRECTIVEACTIONS
No readings on the remote controller
(blank display)
One of the error codes appearsConsult your local dealer.
The schedule timer does work but
the programmed actions are
executed at the wrong time
(e.g. 1 hour too late or too early)
The domestic hot water schedule
timer is programmed but does not
work.
Capacity shortageConsult your local dealer.
• Check if the mains power is still
connected to your installation.
• The benefit kWh rate power supply is
active (see installation manual).
Refer to the installation manual for a
detailed list of error codes.
Check if the clock and the day of the
week are set correctly, correct if
necessary.
In case the pr icon is not displayed,
push the pr button to enable the
schedule timer.
DISPOSALREQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.
Your product is marked with this symbol. This means that
electrical and electronic products shall not be mixed with
unsorted household waste.
Do not try to dismantle the system yourself: the dismantling of the
system, treatment of the refrigerant, of oil and other parts must be
done by a qualified installer in accordance with relevant local and
national legislation.
Units must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring this product is disposed off
correctly, you will help to prevent potential negative consequences for
the environment and human health. Please contact the installer or
local authority for more information.
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system and options