Addendum to installation manual
EKHBRD011ABV1X
EKHBRD014ABV1X
EKHBRD016ABV1X
EKHBRD011ABY1X
EKHBRD014ABY1X
EKHBRD016ABY1X
Addendum to installation manual
CONTENTS Page
General information........................................................................... 1
Combination ...................................................................................... 1
Connecting to a benefit kWh rate power supply................................ 1
Connecting to an EMRQ outdoor unit ...............................................1
Field settings ............................................................................................ 1
Field piping............................................................................................... 1
Capacity index to be allocated to EKHBRD*X unit................................... 1
Field settings table ............................................................................2
The original instructions are written in English. All other languages
are translations of the original instructions.
General information
Thank you for purchasing this unit.
This unit is a special unit of the EKBRD series: EKHBRD*X. This unit
can also be connected to an EMRQ outdoor unit. For general
installation and operation, the supplied installation and operation
manuals must be used.
Some additional attention points are explained in this addendum.
They are specific for the EKHBRD*X series in combination with an
EMRQ outdoor unit. Please read this information carefully. It
overrules the standard information foreseen in the installation and
operation manual.
Combination
Connecting to an EMRQ outdoor unit
For connection and installation of an EKHBRD*X to an EMRQ
outdoor unit, follow the instructions as described in the installation
manual of the EMRQ outdoor unit. Special attention points are
mentioned below.
Field settings
Field setting [7-01] bottom plate heater cannot be used.
Field piping
Piping between refrigerant branch kit and indoor unit
Pipe size for direct connection to indoor unit must be the same size
as the connection size of the indoor unit.
EKHBRD*X
Discharge gas pipe Liquid pipe
Ø15.9 mm Ø9.5 mm
Capacity index to be allocated to EKHBRD*X unit
The index as described in the table below, can be used to check the
connection ratios and to select the refrigerant branch kits.
Indoor unit Capacity index
EKHBRD011*X 100
EKHBRD014*X 125
EKHBRD016*X 140
The unit is the indoor part of the air to water heat pump system. The
unit can only be combined with an ERSQ, ERRQ or EMRQ outdoor
unit.
Connecting to a benefit kWh rate power supply
The EKHBRD*X indoor unit and ERSQ and ERRQ outdoor unit can
be connected to a benefit kWh rate power supply.
Due to compressor reliability reasons, the EMRQ outdoor unit
cannot be connected to a benefit kWh rate power supply.
Addendum to installation manual
1
EKHBRD011~016AB*X
4PW62640-1 – 03.2011
Field settings table
First
Second
code
code
0 Remote control setup
1 Automatic storage timing for domestic water heating
2 Automatic set back function
3 Weather dependent set point
4 Disinfection function
5 Automatic set back and disinfection set point
6 Option setup
7 Option setup
8 Option setup
Setting name
00 User permission level 2 2~3 1 —
01 Room temperature compensation value 0 –5~5 0.5 °C
02 Not applicable. Do not change the default value. 1 — — —
03 Status: space heating schedule timer mode
Method 1=1 / Method 2=0
04 Not applicable. Do not change the default value. 1 — — —
00 Status: night time storage 1 (ON) 0/1 — —
01 Night time storage start time 1:00 0:00~23:00 1:00 hour
02 Status: day time storage 0 (OFF) 0/1 — —
03 Day time storage start time 15:00 0:00~23:00 1:00 hour
00 Status: set back operation 1 (ON) 0/1 — —
01 Set back operation start time 23:00 0:00~23:00 1:00 hour
02 Set back operation stop time 5:00 0:00~23:00 1:00 hour
00 Low ambient temperature (Lo_A) –10 –20~5 1 °C
01 High ambient temperature (Hi_A) 15 10~20 1 °C
02 Set point at low ambient temperature (Lo_Ti) 70 25~80 1 °C
03 Set point at high ambient temperature (Hi_Ti) 45 25~80 1 °C
00 Status: disinfection operation 1 (ON) 0/1 — —
01 Disinfection operation day selection Fri Mon~Sun — —
02 Disinfection operation start time 23:00 0:00~23:00 1:00 hour
00 Set point: disinfection operation temperature 70 60~75 5 °C
01 Disinfection operation time duration 10 5~60 5 min
02 Leaving water set back temperature 5 0~10 1 °C
03 Room set back temperature 18 17~23 1 °C
04 Not applicable. Do not change the default value. 0 — — —
00 Domestic hot water tank installed 0 (OFF) 0/1 — —
01 Optional room thermostat installed 0 (OFF) 0/1 — —
02 Optional backup heater installed 0 (OFF) 0/1 — —
03 Optional solar kit installed 0 (OFF) 0/1 — —
04 Benefit kWh power supply mode 0 0/2 1 —
00 Optional bottom plate heater installed 1 (ON) 0/1 — —
01 Not applicable. Do not change the default value. 0 — — —
02 Multiple set point pattern 0 (A) 0/1 — —
03 Multiple set point 1 0 (OFF) 0/1 — —
04 Multiple set point 2 0 (OFF) 0/1 — —
00 Remote controller temperature control 1 (ON) 0/1 — —
01 Backup heater kit optional setting 1 (ON) 0/1 — —
02 Emergency mode 0 (OFF) 0/1 — —
03 Status: low noise level 1 1~3 1 —
04 Status: freeze-up prevention 0 0~2 1 —
Installer setting at variance with default value
Default
value
1 (ON) 0/1 — —
Range Step UnitDate Val ue Date Val ue
EKHBRD011~016AB*X
4PW62640-1 – 03.2011