1.1About the documentation .............................................................................................................................................. 6
1.1.1Meaning of warnings and symbols ................................................................................................................6
1.2For the installer............................................................................................................................................................... 7
1.2.2Installation site ............................................................................................................................................... 8
2.1About this document ...................................................................................................................................................... 14
2.2Installer reference guide at a glance .............................................................................................................................. 15
3 About the box17
3.1Overview: About the box ................................................................................................................................................ 17
3.2Outdoor unit ................................................................................................................................................................... 17
3.2.1To unpack the outdoor unit ........................................................................................................................... 17
3.2.2To handle the outdoor unit ............................................................................................................................ 18
3.2.3To remove the accessories from the outdoor unit........................................................................................ 18
3.3Indoor unit ...................................................................................................................................................................... 18
3.3.1To unpack the indoor unit .............................................................................................................................. 18
3.3.2To remove the accessories from the indoor unit .......................................................................................... 19
3.3.3To handle the indoor unit............................................................................................................................... 19
4 About the units and options20
4.1Overview: About the units and options.......................................................................................................................... 20
4.2.1Identification label: Outdoor unit .................................................................................................................. 20
4.2.2Identification label: Indoor unit ..................................................................................................................... 21
4.3Combining units and options.......................................................................................................................................... 21
4.3.1Possible combinations of indoor unit and outdoor unit................................................................................ 21
4.3.2Possible options for the outdoor unit ............................................................................................................ 21
4.3.3Possible options for the indoor unit............................................................................................................... 22
5.2Setting up the space heating/cooling system ................................................................................................................ 24
5.3Setting up an auxiliary heat source for space heating ................................................................................................... 35
5.4Setting up the domestic hot water tank......................................................................................................................... 38
5.4.2Selecting the desired temperature for the DHW tank .................................................................................. 38
5.4.3Setup and configuration – DHW tank ............................................................................................................ 39
5.4.4DHW pump for instant hot water .................................................................................................................. 40
5.4.5DHW pump for disinfection ........................................................................................................................... 40
5.5Setting up the energy metering...................................................................................................................................... 41
5.5.3Normal kWh rate power supply ..................................................................................................................... 42
5.5.4Preferential kWh rate power supply .............................................................................................................. 43
5.6Setting up the power consumption control ................................................................................................................... 44
5.6.1Permanent power limitation .......................................................................................................................... 44
5.6.2Power limitation activated by digital inputs .................................................................................................. 45
5.7Setting up an external temperature sensor ................................................................................................................... 46
Installer reference guide
2
6 Unit installation48
6.1Preparing the installation site......................................................................................................................................... 48
6.1.1Installation site requirements of the outdoor unit........................................................................................ 48
6.1.2Additional installation site requirements of the outdoor unit in cold climates............................................ 51
6.1.3Installation site requirements of the indoor unit .......................................................................................... 52
6.2Opening and closing the units ........................................................................................................................................ 53
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Table of contents
6.2.1About opening the units................................................................................................................................. 53
6.2.2To open the outdoor unit ............................................................................................................................... 53
6.2.3To close the outdoor unit ............................................................................................................................... 54
6.2.4To open the indoor unit ................................................................................................................................. 54
6.2.5To lower the switch box on the indoor unit .................................................................................................. 56
6.2.6To close the indoor unit ................................................................................................................................. 57
6.3Mounting the outdoor unit............................................................................................................................................. 57
6.3.1About mounting the outdoor unit ................................................................................................................. 57
6.3.2Precautions when mounting the outdoor unit .............................................................................................. 58
6.3.3To provide the installation structure ............................................................................................................. 58
6.3.4To install the outdoor unit ............................................................................................................................. 59
6.3.5To provide drainage........................................................................................................................................ 59
6.3.6To prevent the outdoor unit from falling over .............................................................................................. 60
6.4Mounting the indoor unit ............................................................................................................................................... 60
6.4.1About mounting the indoor unit .................................................................................................................... 60
6.4.2Precautions when mounting the indoor unit................................................................................................. 60
6.4.3To install the indoor unit ................................................................................................................................ 60
6.4.4To connect the drain hose to the drain ......................................................................................................... 61
6.5Finishing the outdoor unit installation ........................................................................................................................... 62
6.5.1To finish the outdoor unit installation ........................................................................................................... 62
7.2Preparing water piping ................................................................................................................................................... 65
7.3.5To flare the pipe end ...................................................................................................................................... 73
7.3.6To braze the pipe end..................................................................................................................................... 74
7.3.7Using the stop valve and service port ............................................................................................................ 75
7.3.8To connect the refrigerant piping to the outdoor unit ................................................................................. 76
7.3.9To connect the refrigerant piping to the indoor unit .................................................................................... 77
7.4Checking the refrigerant piping...................................................................................................................................... 77
7.4.1About checking the refrigerant piping ........................................................................................................... 77
7.4.2Precautions when checking the refrigerant piping........................................................................................ 78
7.4.3To check for leaks ........................................................................................................................................... 78
7.5.2About the refrigerant ..................................................................................................................................... 80
7.5.3Precautions when charging refrigerant ......................................................................................................... 81
7.5.4To determine the complete recharge amount .............................................................................................. 81
7.5.5To fix the fluorinated greenhouse gases label ............................................................................................... 81
7.6Connecting water piping................................................................................................................................................. 82
7.6.1About connecting the water piping ............................................................................................................... 82
7.6.2Precautions when connecting the water piping ............................................................................................ 82
7.6.3To connect the water piping .......................................................................................................................... 82
7.6.4To connect the recirculation piping ............................................................................................................... 84
7.6.5To fill the water circuit ................................................................................................................................... 84
7.6.6To fill the domestic hot water tank ................................................................................................................ 84
7.6.7To insulate the water piping .......................................................................................................................... 85
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
8 Electrical installation86
8.1About connecting the electrical wiring .......................................................................................................................... 86
8.1.1Precautions when connecting the electrical wiring....................................................................................... 86
8.1.2Guidelines when connecting the electrical wiring......................................................................................... 87
8.1.3Specifications of standard wiring components.............................................................................................. 88
8.1.5About preferential kWh rate power supply ................................................................................................... 89
8.1.6Overview of electrical connections except external actuators ..................................................................... 90
8.2Connections to the outdoor unit.................................................................................................................................... 90
Installer reference guide
3
Table of contents
8.2.1To connect the electrical wiring to the outdoor unit .................................................................................... 90
8.3Connections to the indoor unit ...................................................................................................................................... 91
8.3.1To connect the main power supply................................................................................................................ 93
8.3.2To connect the backup heater power supply ................................................................................................ 95
8.3.3To connect the user interface ........................................................................................................................ 97
8.3.4To connect the shut-off valve ........................................................................................................................ 99
8.3.5To connect the electricity meters .................................................................................................................. 100
8.3.6To connect the domestic hot water pump .................................................................................................... 101
8.3.7To connect the alarm output ......................................................................................................................... 101
8.3.8To connect the space cooling/heating ON/OFF output................................................................................. 102
8.3.9To connect the changeover to external heat source..................................................................................... 104
8.3.10To connect the power consumption digital inputs........................................................................................ 104
8.3.11To connect the safety thermostat (normally closed contact)....................................................................... 105
8.4After connecting the electrical wiring to the indoor unit .............................................................................................. 107
9.1.1To change the user permission level ............................................................................................................. 109
9.1.2To access the most used commands ............................................................................................................. 110
9.1.3To copy the system settings from the first to the second user interface ..................................................... 111
9.1.4Quick wizard: Set the system layout after first power ON ............................................................................ 112
9.2.1Quick wizard: Language / time and date ....................................................................................................... 113
9.2.2Quick wizard: Standard .................................................................................................................................. 113
9.2.4Space heating/cooling control ....................................................................................................................... 120
9.2.5Domestic hot water control ........................................................................................................................... 123
9.2.6Contact/helpdesk number ............................................................................................................................. 124
9.3.1What is a weather-dependent curve? ........................................................................................................... 124
9.4.2Domestic hot water control: advanced ......................................................................................................... 136
10.4.3To perform a test run ..................................................................................................................................... 158
10.4.4To perform an actuator test run .................................................................................................................... 158
12.1 Overview: Maintenance and service .............................................................................................................................. 163
12.3 Checklist for yearly maintenance of the outdoor unit ................................................................................................... 164
12.4 Checklist for yearly maintenance of the indoor unit ..................................................................................................... 164
12.4.1To drain the domestic hot water tank ........................................................................................................... 166
12.5 About cleaning the water filter in case of trouble ......................................................................................................... 167
12.5.1To remove the water filter ............................................................................................................................. 167
12.5.2To clean the water filter in case of trouble.................................................................................................... 168
12.5.3To install the water filter................................................................................................................................ 169
13.2 Precautions when troubleshooting ................................................................................................................................ 170
13.3 Solving problems based on symptoms ........................................................................................................................... 171
13.3.1Symptom: The unit is NOT heating or cooling as expected........................................................................... 171
13.3.2Symptom: The compressor does NOT start (space heating or domestic water heating) ............................ 172
13.3.3Symptom: The system is making gurgling noises after commissioning ........................................................ 172
Installer reference guide
4
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Table of contents
13.3.4Symptom: The pump is blocked..................................................................................................................... 173
13.3.5Symptom: The pump is making noise (cavitation)......................................................................................... 173
13.3.6Symptom: The pressure relief valve opens.................................................................................................... 173
13.3.7Symptom: The water pressure relief valve leaks........................................................................................... 174
13.3.8Symptom: The space is NOT sufficiently heated at low outdoor temperatures........................................... 175
13.3.9Symptom: The pressure at the tapping point is temporarily unusually high................................................ 176
13.3.10 Symptom: Decoration panels are pushed away due to a swollen tank ........................................................ 176
13.3.11 Symptom: Tank disinfection function is NOT completed correctly (AH-error) ............................................. 176
13.4 Solving problems based on error codes ......................................................................................................................... 176
14.2 To pump down ................................................................................................................................................................ 184
15 Technical data186
15.1 Piping diagram: Outdoor unit ......................................................................................................................................... 186
15.2 Piping diagram: Indoor unit ............................................................................................................................................ 187
15.3 Wiring diagram: Outdoor unit ........................................................................................................................................ 188
15.4 Wiring diagram: Indoor unit ........................................................................................................................................... 190
16 Glossary196
17 Field settings table197
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Installer reference guide
5
1 | General safety precautions
1 General safety precautions
In this chapter
1.1About the documentation......................................................................................................................................................6
1.2For the installer.......................................................................................................................................................................7
1.1 About the documentation
▪ The original documentation is written in English. All other languages are
translations.
▪ The precautions described in this document cover very important topics, follow
them carefully.
1.1.1Meaning of warnings and symbols ........................................................................................................................6
1.2.2Installation site .......................................................................................................................................................8
▪ The installation of the system, and all activities described in the installation
manual and in the installer reference guide MUST be performed by an authorised
installer.
1.1.1 Meaning of warnings and symbols
DANGER
Indicates a situation that results in death or serious injury.
DANGER: RISK OF ELECTROCUTION
Indicates a situation that could result in electrocution.
DANGER: RISK OF BURNING
Indicates a situation that could result in burning because of extreme hot or cold
temperatures.
DANGER: RISK OF EXPLOSION
Indicates a situation that could result in explosion.
Installer reference guide
6
WARNING
Indicates a situation that could result in death or serious injury.
WARNING: FLAMMABLE MATERIAL
CAUTION
Indicates a situation that could result in minor or moderate injury.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
NOTICE
Indicates a situation that could result in equipment or property damage.
INFORMATION
Indicates useful tips or additional information.
Symbols used on the unit:
SymbolExplanation
Before installation, read the installation and operation
manual, and the wiring instruction sheet.
Before performing maintenance and service tasks, read the
service manual.
For more information, see the installer and user reference
guide.
The unit contains rotating parts. Be careful when servicing or
inspecting the unit.
1 | General safety precautions
Symbols used in the documentation:
1.2 For the installer
1.2.1 General
If you are NOT sure how to install or operate the unit, contact your dealer.
SymbolExplanation
Indicates a figure title or a reference to it.
Example: " 1–3 Figure title" means "Figure 3 in chapter 1".
Indicates a table title or a reference to it.
Example: " 1–3 Table title" means "Table 3 in chapter 1".
DANGER: RISK OF BURNING
▪ Do NOT touch the refrigerant piping, water piping or internal parts during and
immediately after operation. It could be too hot or too cold. Give it time to return
to normal temperature. If you must touch it, wear protective gloves.
▪ Do NOT touch any accidental leaking refrigerant.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
WARNING
Improper installation or attachment of equipment or accessories could result in
electric shock, short-circuit, leaks, fire or other damage to the equipment. Only use
accessories, optional equipment and spare parts made or approved by Daikin.
WARNING
Make sure installation, testing and applied materials comply with applicable
legislation (on top of the instructions described in the Daikin documentation).
Installer reference guide
7
1 | General safety precautions
CAUTION
Wear adequate personal protective equipment (protective gloves, safety glasses,…)
when installing, maintaining or servicing the system.
WARNING
Tear apart and throw away plastic packaging bags so that nobody, especially
children, can play with them. Possible risk: suffocation.
WARNING
Provide adequate measures to prevent that the unit can be used as a shelter by small
animals. Small animals that make contact with electrical parts can cause
malfunctions, smoke or fire.
CAUTION
Do NOT touch the air inlet or aluminium fins of the unit.
CAUTION
▪ Do NOT place any objects or equipment on top of the unit.
▪ Do NOT sit, climb or stand on the unit.
1.2.2 Installation site
NOTICE
Works executed on the outdoor unit are best done under dry weather conditions to
avoid water ingress.
In accordance with the applicable legislation, it might be necessary to provide a
logbook with the product containing at least: information on maintenance, repair
work, results of tests, stand-by periods,…
Also, at least, following information MUST be provided at an accessible place at the
product:
▪ Instructions for shutting down the system in case of an emergency
▪ Name and address of fire department, police and hospital
▪ Name, address and day and night telephone numbers for obtaining service
In Europe, EN378 provides the necessary guidance for this logbook.
▪ Provide sufficient space around the unit for servicing and air circulation.
▪ Make sure the installation site withstands the weight and vibration of the unit.
▪ Make sure the area is well ventilated. Do NOT block any ventilation openings.
▪ Make sure the unit is level.
Installer reference guide
8
Do NOT install the unit in the following places:
▪ In potentially explosive atmospheres.
▪ In places where there is machinery that emits electromagnetic waves.
Electromagnetic waves may disturb the control system, and cause malfunction of
the equipment.
▪ In places where there is a risk of fire due to the leakage of flammable gases
(example: thinner or gasoline), carbon fibre, ignitable dust.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
1.2.3 Refrigerant
1 | General safety precautions
▪ In places where corrosive gas (example: sulphurous acid gas) is produced.
Corrosion of copper pipes or soldered parts may cause the refrigerant to leak.
If applicable. See the installation manual or installer reference guide of your
application for more information.
NOTICE
Make sure refrigerant piping installation complies with applicable legislation. In
Europe, EN378 is the applicable standard.
NOTICE
Make sure the field piping and connections are NOT subjected to stress.
WARNING
During tests, NEVER pressurize the product with a pressure higher than the
maximum allowable pressure (as indicated on the nameplate of the unit).
WARNING
Take sufficient precautions in case of refrigerant leakage. If refrigerant gas leaks,
ventilate the area immediately. Possible risks:
▪ Excessive refrigerant concentrations in a closed room can lead to oxygen
deficiency.
▪ In case of R410A or R32 refrigerant: Toxic gas might be produced if refrigerant
gas comes into contact with fire.
▪ In case of CO
refrigerant: Refrigerant gas is toxic in high concentrations.
2
DANGER: RISK OF EXPLOSION
Pump down – Refrigerant leakage. If you want to pump down the system, and there
is a leak in the refrigerant circuit:
▪ Do NOT use the unit's automatic pump down function, with which you can collect
all refrigerant from the system into the outdoor unit. Possible consequence: Selfcombustion and explosion of the compressor because of air going into the
operating compressor.
▪ Use a separate recovery system so that the unit's compressor does NOT have to
operate.
WARNING
ALWAYS recover the refrigerant. Do NOT release them directly into the environment.
Use a vacuum pump to evacuate the installation.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
NOTICE
After all the piping has been connected, make sure there is no gas leak. Use nitrogen
to perform a gas leak detection.
Installer reference guide
9
1 | General safety precautions
▪ In case recharge is required, see the nameplate of the unit. It states the type of
refrigerant and necessary amount.
▪ The unit is factory charged with refrigerant and depending on pipe sizes and pipe
lengths some systems require additional charging of refrigerant.
▪ Only use tools exclusively for the refrigerant type used in the system, this to
ensure pressure resistance and prevent foreign materials from entering into the
system.
NOTICE
▪ To avoid compressor breakdown, do NOT charge more than the specified amount
of refrigerant.
▪ When the refrigerant system is to be opened, refrigerant MUST be treated
according to the applicable legislation.
WARNING
Make sure there is no oxygen in the system. Refrigerant may only be charged after
performing the leak test and the vacuum drying.
Possible consequence: Self-combustion and explosion of the compressor because of
oxygen going into the operating compressor.
▪ Charge the liquid refrigerant as follows:
IfThen
A siphon tube is present
Charge with the cylinder upright.
(i.e., the cylinder is marked with "Liquid
filling siphon attached")
A siphon tube is NOT presentCharge with the cylinder upside down.
▪ Open refrigerant cylinders slowly.
▪ Charge the refrigerant in liquid form. Adding it in gas form may prevent normal
operation.
CAUTION
When the refrigerant charging procedure is done or when pausing, close the valve of
the refrigerant tank immediately. If the valve is NOT closed immediately, remaining
pressure might charge additional refrigerant. Possible consequence: Incorrect
refrigerant amount.
1.2.4 Brine
Installer reference guide
10
If applicable. See the installation manual or installer reference guide of your
application for more information.
WARNING
The selection of the brine MUST be in accordance with the applicable legislation.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
1.2.5 Water
1 | General safety precautions
WARNING
Take sufficient precautions in case of brine leakage. If brine leaks, ventilate the area
immediately and contact your local dealer.
WARNING
The ambient temperature inside the unit can get much higher than that of the room,
e.g. 70°C. In case of a brine leak, hot parts inside the unit can create a hazardous
situation.
WARNING
The use and installation of the application MUST comply with the safety and
environmental precautions specified in the applicable legislation.
If applicable. See the installation manual or installer reference guide of your
application for more information.
NOTICE
Make sure water quality complies with EU directive 98/83EC.
1.2.6 Electrical
DANGER: RISK OF ELECTROCUTION
▪ Turn OFF all power supply before removing the switch box cover, connecting
electrical wiring or touching electrical parts.
▪ Disconnect the power supply for more than 1minute, and measure the voltage at
the terminals of main circuit capacitors or electrical components before servicing.
The voltage MUST be less than 50 V DC before you can touch electrical
components. For the location of the terminals, see the wiring diagram.
▪ Do NOT touch electrical components with wet hands.
▪ Do NOT leave the unit unattended when the service cover is removed.
WARNING
If NOT factory installed, a main switch or other means for disconnection, having a
contact separation in all poles providing full disconnection under overvoltage
categoryIII condition, MUST be installed in the fixed wiring.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Installer reference guide
11
1 | General safety precautions
WARNING
▪ ONLY use copper wires.
▪ Make sure the field wiring complies with the applicable legislation.
▪ All field wiring MUST be performed in accordance with the wiring diagram
supplied with the product.
▪ NEVER squeeze bundled cables and make sure they do NOT come in contact with
the piping and sharp edges. Make sure no external pressure is applied to the
terminal connections.
▪ Make sure to install earth wiring. Do NOT earth the unit to a utility pipe, surge
absorber, or telephone earth. Incomplete earth may cause electrical shock.
▪ Make sure to use a dedicated power circuit. NEVER use a power supply shared by
another appliance.
▪ Make sure to install the required fuses or circuit breakers.
▪ Make sure to install an earth leakage protector. Failure to do so may cause
electric shock or fire.
▪ When installing the earth leakage protector, make sure it is compatible with the
inverter (resistant to high frequency electric noise) to avoid unnecessary opening
of the earth leakage protector.
CAUTION
▪ When connecting the power supply: connect the earth cable first, before making
the current-carrying connections.
▪ When disconnecting the power supply: disconnect the current-carrying cables
first, before separating the earth connection.
▪ The length of the conductors between the power supply stress relief and the
terminal block itself must be as such that the current-carrying wires are tautened
before the earth wire is in case the power supply is pulled loose from the stress
relief.
NOTICE
Precautions when laying power wiring:
▪ Do NOT connect wiring of different thicknesses to the power terminal block (slack
in the power wiring may cause abnormal heat).
▪ When connecting wiring which is the same thickness, do as shown in the figure
above.
▪ For wiring, use the designated power wire and connect firmly, then secure to
prevent outside pressure being exerted on the terminal board.
▪ Use an appropriate screwdriver for tightening the terminal screws. A screwdriver
with a small head will damage the head and make proper tightening impossible.
▪ Over-tightening the terminal screws may break them.
Installer reference guide
12
Install power cables at least 1 m away from televisions or radios to prevent
interference. Depending on the radio waves, a distance of 1 m may not be
sufficient.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
1 | General safety precautions
WARNING
▪ After finishing the electrical work, confirm that each electrical component and
terminal inside the electrical components box is connected securely.
▪ Make sure all covers are closed before starting up the unit.
NOTICE
Only applicable if the power supply is three‑phase, and the compressor has an ON/
OFF starting method.
If there exists the possibility of reversed phase after a momentary black out and the
power goes on and off while the product is operating, attach a reversed phase
protection circuit locally. Running the product in reversed phase can break the
compressor and other parts.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Installer reference guide
13
2 | About the documentation
2 About the documentation
In this chapter
2.1About this document.............................................................................................................................................................. 14
2.2Installer reference guide at a glance...................................................................................................................................... 15
2.1 About this document
Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set consists of:
▪ General safety precautions:
- Safety instructions that you must read before installing
- Format: Paper (in the box of the indoor unit)
▪ Operation manual:
- Quick guide for basic usage
- Format: Paper (in the box of the indoor unit)
▪ User reference guide:
- Detailed step-by-step instructions and background information for basic and
advanced usage
- Format: Digital files on http://www.daikineurope.com/support-and-manuals/
product-information/
▪ Installation manual – Outdoor unit:
- Installation instructions
- Format: Paper (in the box of the outdoor unit)
▪ Installation manual – Indoor unit:
- Installation instructions
- Format: Paper (in the box of the indoor unit)
▪ Installer reference guide:
- Preparation of the installation, good practices, reference data,…
- Format: Digital files on http://www.daikineurope.com/support-and-manuals/
product-information/
▪ Addendum book for optional equipment:
Installer reference guide
14
- Additional info about how to install optional equipment
- Format: Paper (in the box of the indoor unit) + Digital files on http://
Latest revisions of the supplied documentation may be available on the regional
Daikin website or via your dealer.
The original documentation is written in English. All other languages are
translations.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
2 | About the documentation
Technical engineering data
▪ A subset of the latest technical data is available on the regional Daikin website
(publicly accessible).
▪ The full set of latest technical data is available on the Daikin Business Portal
(authentication required).
Online tools
In addition to the documentation set, some online tools are available for installers:
▪ Heating Solutions Navigator
- Digital toolbox that offers a variety of tools to facilitate the installation and
configuration of heating systems.
- To access Heating Solutions Navigator, registration to the Stand By Me
platform is required. For more information, see https://
professional.standbyme.daikin.eu.
▪ Daikin e-Care
- Mobile app for installers and service technicians that allows you to register,
configure and troubleshoot heating systems.
- The mobile app can be downloaded for iOS and Android devices using the QR
codes below. Registration to the Stand By Me platform is required to access
the app.
App StoreGoogle Play
2.2 Installer reference guide at a glance
ChapterDescription
General safety precautionsSafety instructions that you must read before
installing
About the documentationWhat documentation exists for the installer
About the boxHow to unpack the units and remove their
accessories
About the units and options▪ How to identify the units
▪ Possible combinations of units and options
Application guidelinesVarious installation setups of the system
Unit installationWhat to do and know to install the system,
including information on how to prepare for an
installation
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Piping installationWhat to do and know to install the piping of the
system, including information on how to
prepare for an installation
Electrical installationWhat to do and know to install the electrical
components of the system, including
information on how to prepare for an
installation
Installer reference guide
15
2 | About the documentation
ConfigurationWhat to do and know to configure the system
CommissioningWhat to do and know to commission the system
Hand‑over to the userWhat to give and explain to the user
Maintenance and serviceHow to maintain and service the units
TroubleshootingWhat to do in case of problems
DisposalHow to dispose of the system
Technical dataSpecifications of the system
GlossaryDefinition of terms
Field settings tableTable to be filled in by the installer, and kept for
ChapterDescription
after it is installed
after it is configured
future reference
Note: There is also an installer settings table in
the user reference guide. This table has to be
filled in by the installer and handed over to the
user.
Installer reference guide
16
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
3 About the box
2
3
1
In this chapter
3.1Overview: About the box........................................................................................................................................................ 17
3.2Outdoor unit ........................................................................................................................................................................... 17
3.2.1To unpack the outdoor unit ................................................................................................................................... 17
3.2.2To handle the outdoor unit.................................................................................................................................... 18
3.2.3To remove the accessories from the outdoor unit ............................................................................................... 18
3.3Indoor unit .............................................................................................................................................................................. 18
3.3.1To unpack the indoor unit...................................................................................................................................... 18
3.3.2To remove the accessories from the indoor unit .................................................................................................. 19
3.3.3To handle the indoor unit ...................................................................................................................................... 19
3.1 Overview: About the box
This chapter describes what you have to do after the boxes with the outdoor and
indoor unit are delivered on-site.
Keep the following in mind:
▪ At delivery, the unit MUST be checked for damage. Any damage MUST be
reported immediately to the claims agent of the carrier.
3 | About the box
▪ Bring the packed unit as close as possible to its final installation position to
prevent damage during transport.
▪ When handling the unit, take into account the following:
▪ Prepare the path along which you want to bring the unit inside in advance.
3.2 Outdoor unit
3.2.1 To unpack the outdoor unit
Fragile, handle the unit with care.
Keep the unit upright in order to avoid damage.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Installer reference guide
17
3 | About the box
abcde
12
8×
3.2.2 To handle the outdoor unit
CAUTION
To avoid injury, do NOT touch the air inlet or aluminium fins of the unit.
3.2.3 To remove the accessories from the outdoor unit
a Outdoor unit installation manual
b Multilingual fluorinated greenhouse gases label
c Drain plug (located on the bottom of the packing case)
d Energy label
e Fluorinated greenhouse gases label
3.3 Indoor unit
3.3.1 To unpack the indoor unit
Installer reference guide
18
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
3.3.2 To remove the accessories from the indoor unit
2×
4×1×4×1×
1×1×1×1×
ab
ghicdef
1×
j
b
aa
b
a Shut-off valves for water circuit
b Overpressure bypass valve
c General safety precautions
d Addendum book for optional equipment
e Indoor unit installation manual
f Operation manual
g Sealing rings for shut-off valves (space heating water circuit)
h Sealing rings for field-supplied shut-off valves (domestic hot water circuit)
i Sealing tape for low voltage wiring intake
j Remote user interface
3 | About the box
3.3.3 To handle the indoor unit
Use the handles at the back and at the bottom to carry the unit.
a Handles at the back of the unit
b Handles at the bottom of the unit. Carefully tilt the unit to the back so that the handles become visible.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Installer reference guide
19
4 | About the units and options
4 About the units and options
In this chapter
4.1Overview: About the units and options ................................................................................................................................. 20
4.2.1Identification label: Outdoor unit .......................................................................................................................... 20
4.2.2Identification label: Indoor unit ............................................................................................................................. 21
4.3Combining units and options.................................................................................................................................................. 21
4.3.1Possible combinations of indoor unit and outdoor unit ....................................................................................... 21
4.3.2Possible options for the outdoor unit.................................................................................................................... 21
4.3.3Possible options for the indoor unit ...................................................................................................................... 22
4.1 Overview: About the units and options
This chapter contains information about:
▪ Identifying the outdoor unit
▪ Identifying the indoor unit
▪ Combining the outdoor unit with options
▪ Combining the indoor unit with options
4.2 Identification
NOTICE
When installing or servicing several units at the same time, make sure NOT to switch
the service panels between different models.
4.2.1 Identification label: Outdoor unit
Location
Model identification
Example: ERLA03DAV3
Installer reference guide
20
CodeExplanation
EREuropean split outdoor pair heat pump
LLow water temperature – ambient zone: −10~−20°C
ARefrigerant R32
03Capacity class
DAModel series
V3Power supply
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
4.2.2 Identification label: Indoor unit
Location
Model identification
Example: EHFH03S18DJ3V
CodeDescription
EEuropean model
HFFloor-standing indoor unit with integrated tank
HH=Heating only
03Capacity class
SIntegrated tank material: Stainless steel
18Integrated tank volume
4 | About the units and options
DJModel series
3VBackup heater model
4.3 Combining units and options
INFORMATION
Certain options might not be available in your country.
4.3.1 Possible combinations of indoor unit and outdoor unit
Outdoor unitIndoor unit
ERLA03DAV3O
4.3.2 Possible options for the outdoor unit
Bottom plate heater (EKBPHT03D)
▪ Prevents freeze-up of the bottom plate.
EHFH03S18DJ3V
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
▪ Recommended in areas with low ambient temperature and high humidity.
▪ Required in areas with ambient temperatures between –7°C and –15°C when the
outdoor unit is installed between 1000 m and 2000 m altitude. See
"6.1.2 Additional installation site requirements of the outdoor unit in cold
climates"[451] for more information.
▪ For installation instructions, see the installation manual of the bottom plate
heater.
Installer reference guide
21
4 | About the units and options
4.3.3 Possible options for the indoor unit
User interface used as room thermostat (BRC1HHDA)
▪ The user interface used as room thermostat can only be used in combination
with the user interface connected to the indoor unit.
▪ The user interface used as room thermostat needs to be installed in the room
that you want to control.
For installation instructions, see the installation and operation manual of the user
interface used as room thermostat.
Room thermostat (EKRTWA, EKRTR1)
You can connect an optional room thermostat to the indoor unit. This thermostat
can either be wired (EKRTWA) or wireless (EKRTR1).
For installation instructions, see the installation manual of the room thermostat
and addendum book for optional equipment.
Remote sensor for wireless thermostat (EKRTETS)
You can use a wireless indoor temperature sensor (EKRTETS) only in combination
with the wireless thermostat (EKRTR1).
For installation instructions, see the installation manual of the room thermostat
and addendum book for optional equipment.
Digital I/O PCB (EKRP1HBAA)
The digital I/O PCB is required to provide following signals:
▪ Alarm output
▪ Space heating/cooling On/OFF output
▪ Changeover to external heat source
For installation instructions, see the installation manual of the digital I/O PCB and
addendum book for optional equipment.
Demand PCB (EKRP1AHTA)
To enable the power saving consumption control by digital inputs you must install
the demand PCB.
For installation instructions, see the installation manual of the demand PCB and
addendum book for optional equipment.
Remote indoor sensor (KRCS01-1)
By default the internal user interface sensor will be used as room temperature
sensor.
As an option the remote indoor sensor can be installed to measure the room
temperature on another location.
Installer reference guide
22
For installation instructions, see the installation manual of the remote indoor
sensor and addendum book for optional equipment.
INFORMATION
▪ The remote indoor sensor can only be used in case the user interface is
configured with room thermostat functionality.
▪ You can only connect either the remote indoor sensor or the remote outdoor
sensor.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
4 | About the units and options
Remote outdoor sensor (EKRSCA1)
By default the sensor inside the outdoor unit will be used to measure the outdoor
temperature.
As an option the remote outdoor sensor can be installed to measure the outdoor
temperature on another location (e.g. to avoid direct sunlight) to have an
improved system behaviour.
For installation instructions, see the installation manual of the remote outdoor
sensor and the addendum book for optional equipment.
INFORMATION
You can only connect either the remote indoor sensor or the remote outdoor sensor.
PC cable (EKPCCAB4)
The PC cable makes a connection between the switch box of the indoor unit and a
PC. It gives the possibility to update the software of the indoor unit.
For installation instructions, see the installation manual of the PC cable.
Pipe bend kit (EKHVTC)
When the indoor unit is installed in a place with limited space, a pipe bend kit can
be installed to facilitate the connection to the refrigerant liquid and gas
connections of the indoor unit.
For installation instructions, see the instruction sheet of the pipe bend kit.
Heat pump convector (FWXV)
For providing space heating/cooling, it is possible to use heat pump convectors
(FWXV).
For installation instructions, see the installation manual of the heat pump
convectors, and the addendum book for optional equipment.
LAN adapter for smartphone control + Smart Grid applications (BRP069A61)
You can install this LAN adapter to:
▪ Control the system via a smartphone app.
▪ Use the system in various Smart Grid applications.
For installation instructions, see the installation manual of the LAN adapter.
LAN adapter for smartphone control (BRP069A62)
You can install this LAN adapter to control the system via a smartphone app.
For installation instructions, see the installation manual of the LAN adapter.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
5.2Setting up the space heating/cooling system ........................................................................................................................ 24
5.2.2Multiple rooms – OneLWT zone ........................................................................................................................... 29
5.2.3Multiple rooms – TwoLWT zones ......................................................................................................................... 33
5.3Setting up an auxiliary heat source for space heating........................................................................................................... 35
5.4Setting up the domestic hot water tank ................................................................................................................................ 38
5.4.1System layout – Integrated DHW tank .................................................................................................................. 38
5.4.2Selecting the desired temperature for the DHW tank .......................................................................................... 38
5.4.3Setup and configuration – DHW tank .................................................................................................................... 39
5.4.4DHW pump for instant hot water .......................................................................................................................... 40
5.4.5DHW pump for disinfection ................................................................................................................................... 40
5.5Setting up the energy metering ............................................................................................................................................. 41
5.5.2Consumed energy .................................................................................................................................................. 41
5.5.3Normal kWh rate power supply............................................................................................................................. 42
5.5.4Preferential kWh rate power supply...................................................................................................................... 43
5.6Setting up the power consumption control........................................................................................................................... 44
5.6.1Permanent power limitation.................................................................................................................................. 44
5.6.2Power limitation activated by digital inputs .......................................................................................................... 45
5.6.3Power limitation process ....................................................................................................................................... 46
5.7Setting up an external temperature sensor........................................................................................................................... 46
5.1 Overview: Application guidelines
The purpose of the application guidelines is to give a glance of the possibilities of
the heatpump system.
NOTICE
▪ The illustrations in the application guidelines are meant for reference only, and
are NOT to be used as detailed hydraulic diagrams. The detailed hydraulic
dimensioning and balancing are NOT shown, and are the responsibility of the
installer.
▪ For more information about the configuration settings to optimize heat pump
operation, see "9Configuration"[4108].
This chapter contains application guidelines for:
▪ Setting up the space heating/cooling system
▪ Setting up an auxiliary heat source for space heating
▪ Setting up the domestic hot water tank
▪ Setting up the energy metering
▪ Setting up the power consumption control
▪ Setting up an external temperature sensor
5.2 Setting up the space heating/cooling system
Installer reference guide
24
The heat pump system supplies leaving water to heat emitters in one or more
rooms.
Because the system offers a wide flexibility to control the temperature in each
room, you need to answer the following questions first:
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
5 | Application guidelines
A
B
a
▪ How many rooms are heated or cooled by the heatpump system?
▪ Which heat emitter types are used in each room and what is their design leaving
water temperature?
Once the space heating/cooling requirements are clear, we recommend to follow
the setup guidelines below.
NOTICE
If an external room thermostat is used, the external room thermostat will control the
room frost protection. However, the room frost protection is only possible if the
leaving water temperature control on user interface of the unit is turned ON.
INFORMATION
In case an external room thermostat is used and room frost protection needs to be
guaranteed in all conditions, then you have to set auto emergency [A.6.C] to 1.
NOTICE
An overpressure bypass valve can be integrated in the system. Keep in mind that this
valve might not be shown on the illustrations.
5.2.1 Single room
Underfloor heating or radiators – Wired room thermostat
Setup
A Main leaving water temperature zone
B One single room
a User interface used as room thermostat
▪ For more information about connecting the electrical wiring to the unit, see:
- "8.2Connections to the outdoor unit"[490]
- "8.3Connections to the indoor unit"[491]
▪ The underfloor heating or radiators are directly connected to the indoor unit.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
▪ The room temperature is controlled by the user interface used as room
thermostat (EKRUDAL1).
Configuration
SettingValue
Unit temperature control:
▪ #: [A.2.1.7]
2 (RT control): Unit operation is
decided based on the ambient
temperature of the user interface.
▪ Code: [C-07]
Installer reference guide
25
5 | Application guidelines
A
B
b
a
Underfloor heating or radiators – Wireless room thermostat
Benefits
▪ Highest comfort and efficiency. The smart room thermostat functionality can
decrease or increase the desired leaving water temperature based on the actual
room temperature (modulation). This results in:
- Stable room temperature matching the desired temperature (higher comfort)
- Less ON/OFF cycles (more quiet, higher comfort and higher efficiency)
- Lowest possible leaving water temperature (higher efficiency)
▪ Easy. You can easily set the desired room temperature via the user interface:
- For your daily needs, you can use preset values and schedules.
- To deviate from your daily needs, you can temporarily overrule the preset
values and schedules, or use the holiday mode.
Setup
A Main leaving water temperature zone
B One single room
a Receiver for wireless external room thermostat
b Wireless external room thermostat
▪ For more information about connecting the electrical wiring to the unit, see:
- "8.2Connections to the outdoor unit"[490]
- "8.3Connections to the indoor unit"[491]
▪ The underfloor heating or radiators are directly connected to the indoor unit.
▪ The room temperature is controlled by the wireless external room thermostat
(optional equipment EKRTR1).
Configuration
SettingValue
Unit temperature control:
▪ #: [A.2.1.7]
1 (Ext RT control): Unit operation
is decided by the external thermostat.
▪ Code: [C-07]
External room thermostat for the main
zone:
▪ #: [A.2.2.4]
1 (Thermo ON/OFF): When the used
external room thermostat or heatpump
convector can only send a thermo ON/
OFF condition.
▪ Code: [C-05]
Installer reference guide
26
Benefits
▪ Wireless. The Daikin external room thermostat is available in a wireless version.
▪ Efficiency. Although the external room thermostat only sends ON/OFF signals, it
is specifically designed for the heatpump system.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
▪ Comfort. In case of underfloor heating, the wireless external room thermostat
a
A
B
prevents condensation on the floor during cooling operation by measuring the
room humidity.
Heatpump convectors
Setup
▪ For more information about connecting the electrical wiring to the unit, see:
5 | Application guidelines
A Main leaving water temperature zone
B One single room
a Remote controller of the heat pump convectors
- "8.2Connections to the outdoor unit"[490]
- "8.3Connections to the indoor unit"[491]
▪ The heatpump convectors are directly connected to the indoor unit.
▪ The desired room temperature is set via the controller of the heat pump
convectors. There are different controllers and setups possible for the heat pump
convectors. For more information, see:
- The installation manual of the heat pump convectors
- The installation manual of the heat pump convector options
- The addendum book for optional equipment
▪ The space heating/cooling demand signal is sent to one digital input on the
indoor unit (X2M/35 and X2M/30).
▪ The space operation mode is sent to the heat pump convectors by one digital
output on the indoor unit (X2M/4 and X2M/3).
Configuration
SettingValue
Unit temperature control:
▪ #: [A.2.1.7]
1 (Ext RT control): Unit operation
is decided by the external thermostat.
▪ Code: [C-07]
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
External room thermostat for the main
zone:
▪ #: [A.2.2.4]
1 (Thermo ON/OFF): When the used
external room thermostat or heatpump
convector can only send a thermo ON/
OFF condition.
▪ Code: [C-05]
Benefits
▪ Cooling. The heat pump convector offers, besides heating capacity, also excellent
cooling capacity.
▪ Efficiency. Optimal energy efficiency because of the interlink function.
▪ Efficiency. Underfloor heating has the best performance with the heat pump
system.
▪ Comfort. The combination of the two heat emitter types provides:
- The excellent heating comfort of the underfloor heating
- The excellent cooling comfort of the heatpump convectors
5.2.2 Multiple rooms – OneLWT zone
If only one leaving water temperature zone is needed because the design leaving
water temperature of all heat emitters is the same, you do NOT need a mixing
valve station (cost effective).
Example: If the heatpump system is used to heat up one floor where all the rooms
have the same heat emitters.
1 (Thermo ON/OFF): When the used
external room thermostat or heatpump
convector can only send a thermo ON/
OFF condition.
Underfloor heating or radiators – Thermostatic valves
If you are heating up rooms with underfloor heating or radiators, a very common
way is to control the temperature of the main room by using a thermostat (this can
either be the user interface or an external room thermostat), while the other
rooms are controlled by so-called thermostatic valves, which open or close
depending on the room temperature.
Setup
A Main leaving water temperature zone
B Room 1
C Room 2
a User interface used as room thermostat
▪ For more information about connecting the electrical wiring to the unit, see:
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
- "8.2Connections to the outdoor unit"[490]
- "8.3Connections to the indoor unit"[491]
▪ The underfloor heating of the main room is directly connected to the indoor unit.
▪ The room temperature is controlled by the user interface used as room
thermostat (EKRUDAL1).
Installer reference guide
29
5 | Application guidelines
A
BC
b
a
M1
a
M2
▪ A thermostatic valve is installed before the underfloor heating in each of the
other rooms.
INFORMATION
Mind situations where the main room can be heated by another heating source.
Example: Fireplaces.
Configuration
SettingValue
Unit temperature control:
▪ #: [A.2.1.7]
2 (RT control): Unit operation is
decided based on the ambient
temperature of the user interface.
▪ Code: [C-07]
Benefits
▪ Easy. Same installation as for one room, but with thermostatic valves.
Underfloor heating or radiators – Multiple external room thermostats
Setup
A Main leaving water temperature zone
B Room 1
C Room 2
a External room thermostat
b Bypass valve
▪ For more information about connecting the electrical wiring to the unit, see:
- "8.2Connections to the outdoor unit"[490]
- "8.3Connections to the indoor unit"[491]
▪ For each room, a shut-off valve (field supplied) is installed to avoid leaving water
supply when there is no heating or cooling demand.
▪ A bypass valve must be installed to make water recirculation possible when all
shut-off valves are closed. To guarantee reliable operation, provide a minimum
water flow as described in table "To check the water volume and flow rate" in
"7.2Preparing water piping"[465].
▪ The user interface connected to the indoor unit decides the space operation
mode. Mind that the operation mode on each room thermostat must be set to
match the indoor unit.
▪ The room thermostats are connected to the shut-off valves, but do NOT have to
be connected to the indoor unit. The indoor unit will supply leaving water all the
time, with the possibility to program a leaving water schedule.
Installer reference guide
30
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10