Daikin EBLA09~16DAV3, EBLA09~16DAW1, EBLA09~16DA3V3, EBLA09~16DA3W1, EDLA09~16DAV3 Installer reference guide [sv]

...
Installatörens referenshandbok
https://daikintechnicaldatahub.eu
Daikin Altherma 3 M
EBLA09~16DAV3 EBLA09~16DAW1 EBLA09~16DA3V3 EBLA09~16DA3W1
EDLA09~16DAV3 EDLA09~16DAW1 EDLA09~16DA3V3 EDLA09~16DA3W1

Innehåll

Innehåll
1 Om dokumentationen 5
1.1 Om detta dokument ....................................................................................................................................................... 5
1.2 Betydelse av varningstexter och symboler..................................................................................................................... 6
1.3 Kort om installatörens referensguide............................................................................................................................. 7
2 Allmänna säkerhetsföreskrifter 9
2.1 För installatören.............................................................................................................................................................. 9
2.1.1 Allmänt............................................................................................................................................................ 9
2.1.2 Installationsplats............................................................................................................................................. 10
2.1.3 Köldmedium – R410A eller R32 ..................................................................................................................... 10
2.1.4 Vatten ............................................................................................................................................................. 12
2.1.5 Elektricitet....................................................................................................................................................... 12
3 Specifika säkerhetsinstruktioner för installatören 15
4 Om lådan 20
4.1 Översikt: Om lådan ......................................................................................................................................................... 20
4.2 Utomhusenheten............................................................................................................................................................ 20
4.2.1 Hur du hanterar utomhusenheten................................................................................................................. 20
4.2.2 Hur du packar upp utomhusenheten............................................................................................................. 21
4.2.3 Hur du avlägsnar alla tillbehör från utomhusenheten .................................................................................. 23
5 Om enheterna och alternativ 25
5.1 Identifikation................................................................................................................................................................... 25
5.1.1 Identifikationsetikett: Utomhusenhet ........................................................................................................... 25
5.2 Kombinera enheter och alternativ ................................................................................................................................. 26
5.2.1 Möjliga tillval för utomhusenheten................................................................................................................ 26
5.2.2 Möjliga kombinationer för utomhusenheten och varmvattenberedaren .................................................... 29
6 Tillämpningsriktlinjer 31
6.1 Översikt: tillämpningsriktlinjer........................................................................................................................................ 31
6.2 Inställning av systemet för rumsuppvärmning/-kylning ................................................................................................ 32
6.2.1 Ett rum ............................................................................................................................................................ 33
6.2.2 Flera rum –Ettområde för framledningstemperaturen ............................................................................... 37
6.2.3 Flera rum –Tvåområden för framledningstemperaturen ............................................................................ 43
6.3 Inställning av en extra värmekälla för rumsuppvärmning ............................................................................................. 46
6.4 Inställning av varmvattenberedaren tank ...................................................................................................................... 49
6.4.1 Systemets layout –Fristående VVB-tank ....................................................................................................... 49
6.4.2 Välja volym och önskad temperatur för VVB-tanken .................................................................................... 49
6.4.3 Inställning och konfiguration –VVB-tank....................................................................................................... 51
6.4.4 VVB-pump för omedelbart varmvatten ......................................................................................................... 51
6.4.5 VVB-pump för desinfektion ............................................................................................................................ 52
6.4.6 Varmvattenpump för förvärmning av tank.................................................................................................... 53
6.5 Inställning av energimätaren.......................................................................................................................................... 54
6.5.1 Producerad värme .......................................................................................................................................... 54
6.5.2 Förbrukad energi ............................................................................................................................................ 54
6.5.3 Layouter för strömförsörjning med energimätare ........................................................................................ 55
6.6 Inställning av energiförbrukningskontrollen .................................................................................................................. 60
6.6.1 Permanent energibegränsning....................................................................................................................... 60
6.6.2 Energibegränsning aktivera av digitala ingångar ........................................................................................... 61
6.6.3 Energibegränsningsprocedur ......................................................................................................................... 62
6.6.4 BBR16 effektbegränsning ............................................................................................................................... 63
6.7 Inställning av en extern temperatursensor.................................................................................................................... 64
7 Installation av enheten 66
7.1 Förberedelse av installationsplatsen.............................................................................................................................. 66
7.1.1 Installationsplatskrav för utomhusenheten................................................................................................... 66
7.1.2 Ytterligare krav för installationsplatsen för utomhusenheten i kalla klimat................................................. 69
7.2 Montering av utomhusenheten ..................................................................................................................................... 69
7.2.1 Om montering av utomhusenheten .............................................................................................................. 69
7.2.2 Försiktighetsåtgärder vid montering av utomhusenheten ........................................................................... 70
7.2.3 Så här förbereder du installationsstrukturen ................................................................................................ 70
7.2.4 Så här installerar du utomhusenheten .......................................................................................................... 71
7.2.5 Så här gör du dräneringen.............................................................................................................................. 71
7.2.6 Installera utloppsgaller ................................................................................................................................... 73
7.3 Öppna och stänga enheten ............................................................................................................................................ 73
Installatörens referenshandbok
2
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Innehåll
7.3.1 Om att öppna enheterna................................................................................................................................ 73
7.3.2 Hur du öppnar utomhusenheten ................................................................................................................... 74
7.3.3 Stänga utomhusenheten ................................................................................................................................ 74
8 Installation av rör 75
8.1 Förbereda vattenrören ................................................................................................................................................... 75
8.1.1 Krav för vattenkretsen.................................................................................................................................... 75
8.1.2 Formel för att räkna ut expansionskärlets förtryck ....................................................................................... 78
8.1.3 Hur du kontrollerar vattenvolymen och flödeshastigheten .......................................................................... 78
8.1.4 Ändra förtrycket för expansionskärlet ........................................................................................................... 81
8.1.5 Hur du kontrollerar vattenvolymen: exempel ............................................................................................... 81
8.2 Ansluta vattenledningar.................................................................................................................................................. 82
8.2.1 Om att ansluta vattenrören ........................................................................................................................... 82
8.2.2 Försiktighetsåtgärder vid anslutning av vattenrör......................................................................................... 82
8.2.3 Hur du ansluter vattenledningarna................................................................................................................ 83
8.2.4 För att skydda vattenkretsen mot frysning.................................................................................................... 84
8.2.5 Så här fyller du på vattenkretsen ................................................................................................................... 87
8.2.6 Hur du fyller varmvattenberedaren ............................................................................................................... 87
8.2.7 Hur du isolerar vattenledningarna ................................................................................................................. 87
9 Elinstallation 89
9.1 Om att ansluta elledningarna ......................................................................................................................................... 89
9.1.1 Försiktighetsåtgärder vid anslutning av elledningarna.................................................................................. 89
9.1.2 Riktlinjer vid anslutning av elledningarna ...................................................................................................... 90
9.1.3 Om elektrisk överensstämmelse .................................................................................................................... 91
9.1.4 Om strömförsörjning med önskad kWh-grad ................................................................................................ 91
9.1.5 Översikt över elektriska anslutningar (exklusive externa ställdon) ............................................................... 92
9.2 Anslutningar till utomhusenheten.................................................................................................................................. 93
9.2.1 Så här ansluter du elkablar till utomhusenheten .......................................................................................... 98
9.2.2 Hur du ansluter nätströmmen ....................................................................................................................... 99
9.2.3 Hur du ansluter reservvärmarens strömkälla ................................................................................................ 102
9.2.4 Extern reservvärmarsats ................................................................................................................................ 103
9.2.5 Hur du ansluter användargränssnittet ........................................................................................................... 110
9.2.6 Hur du ansluter avstängningsventilen ........................................................................................................... 113
9.2.7 Ansluta elmätare ............................................................................................................................................ 114
9.2.8 Hur du ansluter varmvattenpumpen ............................................................................................................. 115
9.2.9 Hur du ansluter larmutsignalen ..................................................................................................................... 115
9.2.10 Hur du ansluter PÅ/AV-utgången för rumsuppvärmning/-kylning................................................................ 116
9.2.11 Hur du ansluter växling till extern värmekälla ............................................................................................... 117
9.2.12 Hur du ansluter de digitala ingångarna för strömförbrukning ...................................................................... 118
9.2.13 Ansluta säkerhetstermostaten (normalt stängd kontakt) ............................................................................. 119
9.2.14 Ansluta en Smart Grid .................................................................................................................................... 120
10 Avsluta installationen av utomhusenheten 124
10.1 Kontroll av isoleringsresistans för kompressorn ............................................................................................................ 124
11 Konfiguration 125
11.1 Översikt: konfiguration ................................................................................................................................................... 125
11.1.1 Få åtkomst till de vanligaste kommandon ..................................................................................................... 126
11.1.2 Ansluta datorkabeln till kopplingsboxen........................................................................................................ 128
11.2 Konfigurationsguiden...................................................................................................................................................... 129
11.3 Möjliga skärmar .............................................................................................................................................................. 130
11.3.1 Möjliga skärmar: Översikt .............................................................................................................................. 130
11.3.2 Startskärmen .................................................................................................................................................. 131
11.3.3 Huvudmenyn .................................................................................................................................................. 134
11.3.4 Menyskärmen ................................................................................................................................................. 135
11.3.5 Inställningsskärm ............................................................................................................................................ 135
11.3.6 Detaljerad skärm med värden........................................................................................................................ 136
11.4 Förinställda värden och scheman................................................................................................................................... 137
11.4.1 Hur du använder förinställda värden ............................................................................................................. 137
11.4.2 Hur du använder och ställer in scheman ....................................................................................................... 137
11.4.3 Schemaskärm: Exempel ................................................................................................................................. 141
11.4.4 Ställa in energipriser....................................................................................................................................... 145
11.5 Väderberoende kurva ..................................................................................................................................................... 147
11.5.1 Vad är en väderberoende kurva?................................................................................................................... 147
11.5.2 2-punktskurva ................................................................................................................................................. 147
11.5.3 Lutningskalibrerad kurva ................................................................................................................................ 148
11.5.4 Använda väderberoende kurvor .................................................................................................................... 150
11.6 Inställningsmeny ............................................................................................................................................................. 152
11.6.1 Felfunktion...................................................................................................................................................... 152
11.6.2 Rum ................................................................................................................................................................. 152
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Installatörens referenshandbok
3
Innehåll
11.6.3 Huvudområde ................................................................................................................................................. 157
11.6.4 Extrazon .......................................................................................................................................................... 166
11.6.5 Uppvärmning/kylning av rum......................................................................................................................... 171
11.6.6 Beredare ......................................................................................................................................................... 179
11.6.7 Användarinställningar..................................................................................................................................... 187
11.6.8 Information ..................................................................................................................................................... 192
11.6.9 Installatörsinställningar .................................................................................................................................. 193
11.6.10 Driftsättning.................................................................................................................................................... 218
11.6.11 Drift ................................................................................................................................................................. 219
11.6.12 WLAN .............................................................................................................................................................. 219
11.7 Menystruktur: översikt över användarinställningarna................................................................................................... 222
11.8 Menystruktur: översikt över installationsinställningarna .............................................................................................. 224
12 Driftsättning 225
12.1 Översikt: driftsättning..................................................................................................................................................... 225
12.2 Försiktighetsåtgärder vid driftsättning........................................................................................................................... 226
12.3 Checklista före driftsättning ........................................................................................................................................... 226
12.4 Checklista under driftsättning ........................................................................................................................................ 227
12.4.1 Minsta flödeshastighet ................................................................................................................................... 227
12.4.2 Luftning ........................................................................................................................................................... 228
12.4.3 Testkörning ..................................................................................................................................................... 230
12.4.4 Testköra ställdon ............................................................................................................................................ 231
12.4.5 Torkning av golvärmens flytspackel ............................................................................................................... 232
13 Överlämna till användaren 235
14 Underhåll och service 236
14.1 Säkerhetsföreskrifter vid underhåll................................................................................................................................ 236
14.2 Årligt underhåll ............................................................................................................................................................... 236
14.2.1 Årligt underhåll av utomhusenheten: översikt .............................................................................................. 236
14.2.2 Årligt underhåll av utomhusenheten: instruktioner...................................................................................... 237
15 Felsökning 239
15.1 Översikt: Felsökning........................................................................................................................................................ 239
15.2 Försiktighetsåtgärder vid felsökning .............................................................................................................................. 239
15.3 Lösa problem med hjälp av symptom ............................................................................................................................ 240
15.3.1 Symptom: enheten värmer INTE upp eller kyler som förväntat ................................................................... 240
15.3.2 Symptom: Varmvattnet når INTE önskad temperatur................................................................................... 240
15.3.3 Symptom: kompressorn startar INTE (rumsuppvärmning eller uppvärmning av varmvattnet) .................. 241
15.3.4 Symptom: Det hörs gurglande ljud från systemet efter driftsättning........................................................... 241
15.3.5 Symptom: pumpen är blockerad.................................................................................................................... 242
15.3.6 Symptom: Pumpen för oväsen (kavitering) ................................................................................................... 242
15.3.7 Symptom: övertrycksventilen öppnas ........................................................................................................... 243
15.3.8 Symptom: Vattenövertrycksventilen läcker................................................................................................... 243
15.3.9 Symptom: rummet värms INTE upp tillräckligt vid låga utomhustemperaturer .......................................... 244
15.3.10 Symptom: trycket vid tappunkten är tillfälligt ovanligt högt......................................................................... 245
15.3.11 Symptom: Tankens desinfektionsfunktion har INTE slutförts korrekt (AH-fel)............................................. 245
15.4 Lösa problem baserade på felkoder............................................................................................................................... 245
15.4.1 För att visa hjälptexten i händelse av en felfunktion..................................................................................... 246
15.4.2 Felkoder för enheten...................................................................................................................................... 246
16 Kassering 251
16.1 Hur du återvinner köldmediet........................................................................................................................................ 251
16.1.1 Så här öppnar du stoppventilerna ................................................................................................................. 252
16.1.2 Så här öppnar du de elektroniska expansionsventilerna............................................................................... 252
16.1.3 Återvinningsläge — I händelse av 3N~-modeller (7-segmentsdisplay)......................................................... 253
16.1.4 Återvinningsläge — I händelse av 1N~-modeller (7-LED-display) ................................................................. 256
17 Tekniska data 258
17.1 Serviceutrymme: Utomhusenhet ................................................................................................................................... 259
17.2 Rördragningsschema: Utomhusenhet............................................................................................................................ 261
17.3 Kopplingsschema: Utomhusenhet.................................................................................................................................. 263
Installatörens referenshandbok
4
18 Ordlista 271
19 Lokala inställningar, tabell 272
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06

1 Om dokumentationen

I detta kapitel

1.1 Om detta dokument ............................................................................................................................................................... 5
1.2 Betydelse av varningstexter och symboler ............................................................................................................................ 6
1.3 Kort om installatörens referensguide .................................................................................................................................... 7

1.1 Om detta dokument

Målgrupp
Behöriga installatörer
Dokumentuppsättning
Detta dokument är en del av en dokumentuppsättning. Den kompletta dokumentuppsättningen består av:
Allmänna säkerhetsföreskrifter:
- Säkerhetsanvisningar som du måste läsa före installationen
1 | Om dokumentationen
- Format: Papper (i lådan för utomhusenheten)
Bruksanvisning:
- Snabbstartguide för grundläggande användning
- Format: Papper (i lådan för utomhusenheten)
Användarhandbok:
- Utförliga instruktioner i steg-för-steg och bakgrundsinformation för
grundläggande och avancerad användning
- Format: Digitala filer på http://www.daikineurope.com/support-and-manuals/
product-information/
Installationshandbok:
- Installationsanvisningar
- Format: Papper (i lådan för utomhusenheten)
Installatörens referenshandbok:
- Förberedelser inför installationen, goda råd, referensuppgifter,…
- Format: Digitala filer på http://www.daikineurope.com/support-and-manuals/
product-information/
Tilläggsbok för extrautrustning:
- Ytterligare information om hur extrautrustningen ska installeras
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
- Format: Papper (i lådan för utomhusenheten) + Digitala filer på http://
www.daikineurope.com/support-and-manuals/product-information/
De senaste versionerna av den medföljande dokumentationen kan finnas på Daikins lokala webbplats eller genom din återförsäljare.
Den ursprungliga dokumentationen har skrivits på engelska. Alla andra språk är översättningar.
Tekniska data ▪ Delar av de senaste tekniska data är tillgängliga på den regionala Daikin-
webbplatsen (allmänt tillgänglig).
Installatörens referenshandbok
5
1 | Om dokumentationen
Alla de senaste tekniska data finns på Daikin Business Portal (inloggning krävs).
Online-verktyg
Som tillägg till dokumentuppsättningen finns vissa online-verktyg tillgängliga för installatörer:
Daikin Technical Data Hub
- Central hubb för enhetens tekniska specifikationer, användbara verktyg,
digitala resurser m.m.
- Tillgänglig för allmänheten via https://daikintechnicaldatahub.eu.
Heating Solutions Navigator
- Digital verktygslåda som erbjuder en mängd olika verktyg för installation och
konfiguration av värmesystemet.
- För åtkomst av Heating Solutions Navigator krävs registrering i Stand By Me-
plattformen. Mer information finns i https://
professional.standbyme.daikin.eu/.
Daikin e-Care
- Mobilapp för installatörer och servicetekniker där du kan registrera,
konfigurera och felsöka värmesystem.
- Du kan hämta mobilappen för iOS- och Android-enheter genom att använda
QR-koderna nedan. Registrering i Stand By Me-plattformen krävs för åtkomst av appen.
App Store Google Play

1.2 Betydelse av varningstexter och symboler

FARA
Anger en situation som leder till död eller allvarlig skada.
FARA: RISK FÖR ELCHOCK
Anger en situation som kan leda till att du får en elchock.
FARA: RISK FÖR BRÄNNSKADA/SKÅLLNING
Indikerar en situation som kan orsaka brännskada/skållning på grund av extremt höga eller låga temperaturer.
Installatörens referenshandbok
6
FARA: RISK FÖR EXPLOSION
Anger en situation som kan leda till en explosion.
VARNING
Anger en situation som kan leda till död eller allvarlig skada.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
VARNING: BRANDFARLIGT MATERIAL
FÖRSIKTIGT
Anger en situation som kan leda till mindre eller måttliga skador.
NOTERING
Anger en situation som kan leda till skador på utrustningen eller lokalen.
INFORMATION
Anger användbara råd eller ytterligare information.
Symboler som används på enheten:
Symbol Förklaring
Läs igenom installations- och bruksanvisningen samt kopplingsinstruktionerna inför installation.
Läs servicehandboken inför underhålls- och serviceuppgifter.
1 | Om dokumentationen
Mer information finns i installations- och användarhandboken.
Enheten innehåller roterande komponenter. Var försiktig vid service eller inspektion av enheten.
Symboler som används i dokumentationen:
Symbol Förklaring
Indikerar en bildrubrik eller en referens till den. Exempel: " 1–3 Bildrubrik" betyder "Bild 3 i kapitel 1".
Indikerar en tabellrubrik eller referens till den. Exempel: " 1–3 Tabellrubrik" betyder "Tabell 3 i kapitel 1".

1.3 Kort om installatörens referensguide

Kapitel Beskrivning
Om dokumentationen Vilken dokumentation finns för installatören
Allmänna säkerhetsföreskrifter Säkerhetsanvisningar som du måste läsa före
Specifika säkerhetsanvisningar för installation
installationen
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Om lådan Så här hanterar du lådan, packar upp enheterna
och avlägsnar deras tillbehör
Om enheterna och alternativ Så här identifieras enheterna
Möjliga enhetskombinationer och alternativ
Tillämpningsriktlinjer Olika installationsinställningar för systemet
Installatörens referenshandbok
7
1 | Om dokumentationen
Kapitel Beskrivning
Installation av enheten Vad du behöver göra och känna till för att
installera systemet, inklusive information om hur du förbereder för en installation
Installation av rör Vad du behöver göra och känna till för att
installera systemets rördragning, inklusive information om hur du förbereder för en installation
Elinstallation Vad du behöver göra och känna till för att
installera systemets elkomponenter, inklusive information om hur du förbereder för en installation
Avsluta installationen av utomhusenheten
Vad ska göras när enheten, rören och elen har installerats
Konfiguration Vad ska göras och vad bör jag veta för att
konfigurera systemet när det är installerat
Driftsättning Vad ska göras och vad bör jag veta för att
driftsätta systemet när det är konfigurerat
Överlämna till användaren Vad ska ges till och vad ska förklaras till
användaren
Underhåll och service Så här underhåller du och utför service på
enheterna
Felsökning Vad ska göras om ett problem skulle uppstå
Kassering Så här kasseras systemet
Tekniska data Systemets specifikationer
Ordlista Definition på termer
Lokala inställningar, tabell Tabell som ska fyllas i av installatören, samt
behållas för framtida referens Obs: Det finns också en tabell för
installatörsinställningar i användarens referenshandbok. Denna tabell ska fyllas i av installatören och överlämnas till användaren.
Installatörens referenshandbok
8
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
2 | Allmänna säkerhetsföreskrifter

2 Allmänna säkerhetsföreskrifter

I detta kapitel

2.1 För installatören...................................................................................................................................................................... 9
2.1.1 Allmänt ................................................................................................................................................................... 9
2.1.2 Installationsplats .................................................................................................................................................... 10
2.1.3 Köldmedium – R410A eller R32 ............................................................................................................................. 10
2.1.4 Vatten ..................................................................................................................................................................... 12
2.1.5 Elektricitet .............................................................................................................................................................. 12

2.1 För installatören

2.1.1 Allmänt

Kontakta din installatör om du INTE är säker på hur du installerar eller använder enheten.
FARA: RISK FÖR BRÄNNSKADA/SKÅLLNING
Vidrör INTE köldmedierör, vattenledningar eller interna delar under eller
omedelbart efter drift. De kan vara för varma eller för kalla. Vänta tills de återgår till normal temperatur. Använd skyddshandskar om du måste röra vid dem.
Vidrör ALDRIG oavsiktligt läckage av köldmediet.
VARNING
Felaktig installation eller anslutning av utrustning eller tillbehör kan orsaka elchock, kortslutning, läckage, brand eller annan skada på utrustningen. Använd endast tillbehör, extrautrustning och reservdelar som tillverkats eller godkänts av Daikin.
VARNING
Se till att installationen, kontroller och använda material överensstämmer med gällande lagstiftning (utöver instruktionerna i dokumentationen Daikin).
FÖRSIKTIGT
Bär lämplig personlig skyddsutrustning (skyddshandskar, säkerhetsglasögon, etc.) under installationen, underhållet eller reparationen av systemet.
VARNING
Riv isär och kasta plastförpackningsmaterialet så att ingen, speciellt barn, inte kan leka med det. Möjlig risk: kvävning.
VARNING
Vidta nödvändiga åtgärder för att förebygga att smådjur söker skydd i enheten. Smådjur som kommer i kontakt med strömförande delar kan orsaka fel, rökutveckling eller eldsvåda.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
FÖRSIKTIGT
Vidrör INTE enhetens luftintag eller aluminiumspjäll eftersom det finns risk för att du skadas.
Installatörens referenshandbok
9
2 | Allmänna säkerhetsföreskrifter
I enlighet med gällande lagstiftning kan det vara nödvändigt att föra en loggbok över utrustningen. Denna ska alltid innehålla: information om underhåll, reparationsarbete, kontrollresultat, passningstider, etc.
Dessutom SKA minst följande information om systemet vara tillgänglig på lätt åtkomlig plats:
Nedstängningsinstruktioner i händelse av nödfallNamn och adress till brandkår, polis och sjukhusNamn, adress och jourtelefonnummer till serviceavdelningar
I Europa ger EN378 nödvändig ledning för den här loggboken.
FÖRSIKTIGT
Placera INTE föremål eller utrustning ovanpå enheten.Sitt INTE, klättra eller stå på enheten.
NOTERING
Arbeten som utförs på utomhusenheten ska helst göras under torra väderförhållanden för att förhindra vatteninträngning.

2.1.2 Installationsplats

Se till att det finns tillräckligt med utrymme runt enheten för tillräcklig
luftcirkulation.
Kontrollera att golvet är tillräckligt starkt för att bära inomhusenhetens vikt och
vibrationer.
Se till att området är väl ventilerat. Blockera ALDRIG några ventilationsöppningar.Se till att enheten står på en jämn yta.
Installera INTE enheten på någon av följande platser:
I miljöer med explosionsrisk.I närheten av maskiner som avger elektromagnetiska vågor. Elektromagnetiska
vågor kan störa styrsystemet och göra att utrustningen inte fungerar som den ska.
På platser med risk för brand på grund av läckage av brandfarliga gaser (t.ex.
lösningsmedel eller bensin), kolfiber eller lättantändligt damm.
På platser där frätande gas (t.ex. svavelsyrliga gaser) produceras. Korrosion av
kopparledningar eller lödda delar kan orsaka att köldmediet läcker ut.

2.1.3 Köldmedium – R410A eller R32

Installatörens referenshandbok
10
Om tillämpligt. Se installationshandboken eller installatörens referenshandbok för mer information.
NOTERING
Se till att köldmedierören överensstämmer med gällande lagstiftning. I Europa är EN378 den gällande standarden.
NOTERING
Se till att utomhusledningar och -anslutningar INTE utsätts för belastning.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
2 | Allmänna säkerhetsföreskrifter
VARNING
Under kontroller får du ALDRIG trycksätta apparaterna med ett tryck som överstiger det högsta tillåtna trycket (anges på enhetens märkplåt).
VARNING
Vidta tillräckliga försiktighetsåtgärder i händelse av eldsvåda som orsakas av läckande köldmedium. Om köldmediumångor läcker ut ska området omedelbart ventileras. Möjliga risker:
För hög koncentration av köldmedium i slutna miljöer kan leda till syrebrist.Giftig gas kan produceras om köldmediumångor kommer i kontakt med eld.
FARA: RISK FÖR EXPLOSION
Nedpumpning – läckage av köldmedium. Om du vill tömma systemet och det finns
en läcka i köldmediumkretsen:
Använd INTE enhetens automatiska tömningsfunktion som samlar allt
köldmedium från systemet i utomhusenheten. Trolig konsekvens: Självantändning och explosion i kompressorn på grund av luft som kommer in i driftkompressorn.
Använd ett separat återvinningssystem så att enhetens kompressor INTE behöver
köras.
VARNING
Återvinn ALLTID köldmedium. Släpp ALDRIG ut dem direkt i miljön. Använd en vakuumpump för att evakuera installationen.
NOTERING
När alla rör anslutits ska man kontrollera att inte gas läcker ut. Använd kvävgas för att utföra gasläckagekontroll.
NOTERING
Fyll INTE på mer än den angivna mängden köldmedel eftersom det kan skada
kompressorn.
När köldmediumsystemet ska öppnas MÅSTE köldmedium hanteras enligt
tillämplig lagstiftning.
VARNING
Se till att det inte finns något syre i systemet. Köldmedium får endast fyllas på efter utförd läckagetest och vakuumtorkning.
Trolig konsekvens: Självförbränning och explosion av kompressorn på grund av att syre som kommer in i kompressorn som är i drift.
Om påfyllning blir nödvändig finns information på enhetens namnplåt. Här anges
typ av köldmedium och nödvändig mängd.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Utomhusenheten har fyllts på med köldmedium från fabrik och beroende på
rörtjocklek och rörlängder kan vissa system behöva ytterligare påfyllning av köldmedium.
Använd endast verktyg den kylmediumtyp som används i systemet för att
upprätthålla nödvändigt tryck och förhindra att främmande föremål kommer in i systemet.
Fyll på kylmediumvätska som följer:
Installatörens referenshandbok
11
2 | Allmänna säkerhetsföreskrifter
Om
Ett hävertrör finns
Påfyllning med cylindern upprätt.
(d.v.s. cylindern är markerad med "Liquid filling siphon attached" – hävert för vätskepåfyllning ansluten)
Ett hävertrör finns INTE Påfyllning med cylindern upp och ned.
Öppna kylmediumcylindrar långsamt.Fyll på kylmediet i vätskeform. Om du fyller på det i gasform är normal drift inte
möjlig.
FÖRSIKTIGT
När köldmediumpåfyllningen är slutförd eller när du tar en paus ska du omedelbart stänga ventilen på köldmediumtanken. Om ventilen INTE omedelbart stängs kan det återstående trycket ge ytterligare påfyllning av köldmedium. Trolig konsekvens: Felaktig mängd köldmedium.

2.1.4 Vatten

2.1.5 Elektricitet

Om tillämpligt. Se installationshandboken eller installatörens referenshandbok för mer information.
NOTERING
Se till att vattenkvaliteten uppfyller EU-direktivet 98/83 EG.
FARA: RISK FÖR ELCHOCK
Stäng AV all strömförsörjning innan du tar bort kopplingsboxens lock, ansluter
elkablar eller vidrör elektriska komponenter.
Koppla från strömförsörjningen i mer än 10 minuter, och mät spänningen över
kontakterna för huvudkretsens kondensatorer eller elektriska komponenter innan något servicearbete inleds. Spänningen MÅSTE vara mindre än 50 V likspänning innan du kan röra vid elektriska komponenter. Du kan se var kontakterna finns i kopplingsschemat.
Vidrör INTE elektriska komponenter med fuktiga fingrar.Lämna ALDRIG enheten obevakad när serviceluckan är borttagen.
Installatörens referenshandbok
12
VARNING
Om enheten INTE är fabriksinstallerad MÅSTE en huvudbrytare eller andra medel för att kunna koppla ifrån enheten installeras, med en kontaktseparation i alla poler som resulterar i fullständig bortkoppling enligt villkoren i överspänningsklassIII, i den fasta kabeldragningen.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
2 | Allmänna säkerhetsföreskrifter
VARNING
Använd ENDAST kopparledningar.Se till att lokal kabeldragning görs i enlighet med gällande lagstiftning.All lokal kabeldragning MÅSTE utföras i enlighet med kopplingsschemat som
medföljer produkten.
Kläm ALDRIG kabelbuntar och se till att de INTE kommer i kontakt med icke-
isolerade ledningar eller vassa kanter. Kontrollera att ingen extern belastning påfrestar kabelanslutningarna.
Se till att installera jordledare. Jorda INTE enheten till en vattenledning, ett
vågfrontskydd eller en jordledning för telefon. Ofullständig jordning kan leda till elektriska stötar.
Se till att använda en dedikerad strömkrets. Dela ALDRIG strömförsörjning med
någon annan apparat.
Se till att nödvändiga säkringar eller kretsbrytare installeras.Se till att installera en jordfelsbrytare. Om inte detta följs kan det resultera i
elektriska stötar eller eldsvåda.
Vid installation av jordfelsbrytaren ska du kontrollera att den är kompatibel med
invertern (som klarar högfrekvent elektriskt brus) för undvika att jordfelsbrytaren löser ut i onödan.
FÖRSIKTIGT
Vid anslutning av strömkabeln ska jordkabeln anslutas innan någon strömförande
anslutning görs.
Vid frånkoppling av strömkabeln ska strömförande anslutningar kopplas från
innan jordkabeln kopplas från.
Kabellängden mellan strömkabelns anslutning och terminalblocket måste vara
sådan att de strömförande kablarna sträcks före jordkabeln om strömkabeln dras loss från kabelfästet.
NOTERING
Säkerhetsåtgärder vid dragning av elledningar:
Anslut INTE kablar med olika tjocklek till strömförsörjningsplinten (för mycket
spelrum kan orsaka onormal värme).
När du ansluter kablar av samma tjocklek gör du enligt anvisningarna ovan.Vid ledningsdragning använder du angiven strömkabel och ansluter den
ordentligt. Fäst den sedan så att inte plinten utsätts för belastning utifrån.
Använd en lämplig skruvmejsel för att dra åt terminalskruvarna. En skruvmejsel
med för litet huvud förstör skruven och gör det omöjligt att dra åt den.
Om du drar åt terminalskruvarna för hårt kan de gå sönder.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Installera strömkablar på minst 1 meters avstånd från tv- eller radioapparater för att förebygga störningar. Beroende på radiovågorna kan ett avstånd på 1 meter vara otillräckligt.
Installatörens referenshandbok
13
2 | Allmänna säkerhetsföreskrifter
VARNING
När du är färdig med elanslutningarna kontrollerar du att alla elektriska
komponenter och kontakter i eldosan är ordentligt anslutna.
Se till att alla skyddskåpor är stängda innan du sätter igång enheten.
NOTERING
Gäller endast om strömförsörjningen har tre faser och kompressorn har en PÅ/AV startmetod.
Om det föreligger risk för omvänd faskoppling efter tillfälligt strömavbrott och/eller om strömmen kommer och går när produkten är i drift, då kan man montera ett externt fasskydd. Om produkten körs med fasfel kan kompressorn och andra komponenter skadas.
Installatörens referenshandbok
14
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06

3 | Specifika säkerhetsinstruktioner för installatören

3 Specifika säkerhetsinstruktioner för
installatören
Följ alltid följande säkerhetsinstruktioner och föreskrifter.
Hantera enheten (se
"Hur du hanterar utomhusenheten"[420]
FÖRSIKTIGT
För att undvika skador ska du INTE vidröra enhetens luftintag eller aluminiumflänsar.
Tillämpningsriktlinjer (se
FÖRSIKTIGT
Om det finns mer än en avlämningszon för vatten ska du ALLTID installera en blandventil i huvudrummet för att sänka (vid uppvärmning)/höja (vid kylning) framledningstemperaturen när extrazonen har behov.
Monteringsplats (se
"7.1Förberedelse av installationsplatsen"[466]
VARNING
Observera måtten för serviceutrymmet i den här handboken för korrekt installation av enheten. Se "17.1Serviceutrymme: Utomhusenhet"[4259].
Specialkrav för R32 (se
"Installationsplatskrav för utomhusenheten"[466]
VARNING
Punktera EJ och bränn EJ.Använd INGA andra metoder för att påskynda avfrostningsprocessen eller
rengöring av utrustningen än de som rekommenderas av tillverkaren.
Var medveten om att köldmedium R32 är luktfritt.
"6Tillämpningsriktlinjer"[431]
)
)
)
)
VARNING
Apparaten ska förvaras så att mekaniska skada förhindras och i ett välventilerat rum utan kontinuerliga antändningskällor (till exempel: öppen eld, en gasolvärmare eller ett elektriskt element som är på).
VARNING
Kontrollera att installation, service, underhåll och reparation följer instruktionerna från Daikin och tillämplig lagstiftning (till exempel nationella regler för gashantering) samt endast utförs av behöriga personer.
Montering av utomhusenheten (se
VARNING
Fästmetoden för utomhusenheten MÅSTE följa instruktionerna i denna handbok. Se
"7.2Montering av utomhusenheten"[469].
Öppna och stänga enheten (se
"7.3Öppna och stänga enheten"[473]
FARA: RISK FÖR ELCHOCK
Lämna INTE enheten obevakad när serviceluckan har avlägsnats.
"7.2Montering av utomhusenheten"[469]
)
)
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Installatörens referenshandbok
15
3 | Specifika säkerhetsinstruktioner för installatören
FARA: RISK FÖR ELCHOCK
FARA: RISK FÖR BRÄNNSKADA/SKÅLLNING
Installation av rör (se
"8Installation av rör"[475]
VARNING
Externa rör MÅSTE monteras i enlighet med anvisningarna i denna handbok. Se
"8Installation av rör"[475].
Om frysskydd med glykol används:
VARNING
Etylenglykol är giftigt.
VARNING
På grund av att glykol används kan korrosion uppkomma i systemet. Glykol utan inhibitor omvandlas till en syra genom oxidering. Denna process påskyndas när koppar används och vid höga temperaturer. Den syrliga glykolen utan inhibitor attackerar metallytor och bildar galvaniska korrosionsceller som orsakar allvarliga skador på systemet. Därför är det viktigt att:
vattenreningen har utförts korrekt av en kvalificerad vattenspecialist;glykol med korrosionsinhibitorer väljs för att motverka syrabildning genom
oxidering av glykol;
ingen bilglykol används eftersom deras korrosionsinhibitorer har en begränsad
livslängd och innehåller silikater som kan förorena eller plugga igen systemet;
galvaniserade rör INTE används i glykolsystem eftersom de kan leda till utfällning
av vissa komponenter i glykolens korrosionsinhibitor;
)
Elinstallation (se
VARNING
Metoden för elanslutningar MÅSTE vara i enlighet med anvisningarna i
denna handbok. Se "9Elinstallation"[489].Elschemat medföljer enheten och finns placerat på insidan av serviceluckan. För
förklaringar, se "17.3Kopplingsschema: Utomhusenhet"[4263].
FARA: RISK FÖR ELCHOCK
VARNING
Använd ALLTID flerkärniga kablar till strömförsörjningsledningar.
"9Elinstallation"[489]
)
Installatörens referenshandbok
16
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
3 | Specifika säkerhetsinstruktioner för installatören
VARNING
All kabeldragning FÅR ENDAST utföras av en auktoriserad elektriker och MÅSTE
följa gällande bestämmelser.
Gör alla elektriska anslutningar till den fasta kabeldragningen.Alla komponenter som anskaffats lokalt och alla elektriska konstruktioner SKALL
följa gällande bestämmelser.
VARNING
Om strömmatningen saknar eller har fel N-fas kan utrustningen förstöras.Upprätta korrekt jordning. Jorda INTE enheten till en vattenledning, ett
vågfrontskydd eller en jordledning för telefon. Ofullständig jordning kan leda till elektriska stötar.
Installera nödvändiga säkringar eller kretsbrytare.Säkra elkablarna med buntband så att de INTE kommer i kontakt med vassa
kanter eller rör, särskilt på högtryckssidan.
Använd INTE skarvade kablar, fåtrådiga ledare, förlängningssladdar eller
fasfördelade anslutningar. De kan orsaka överhettning, elektrisk chock eller eldsvåda.
Installera INTE en fasförskjutande kondensator, eftersom enheten är försedd med
en inverter. En fasförskjutande kondensator försämrar prestandan och kan orsaka olyckor.
VARNING
Roterande fläkt. Innan du slår PÅ utomhusenheten bör du se till att utloppsgallret
täcker över fläkten som skydd mot fläktens rotation. Se "Installera
utloppsgaller"[473].
FÖRSIKTIGT
Tryck INTE eller placera överskottskabel i enheten.
VARNING
Reservvärmaren MÅSTE ha en tilldelad strömförsörjning och MÅSTE skyddas av de skyddsenheter som krävs av gällande lagstiftning.
FÖRSIKTIGT
För att säkerställa att enheten är helt jordad, se alltid till att ansluta reservvärmaren till ett jordat uttag.
VARNING
Avskalad ledning. Verifiera att ingen avskalad ledning får komma i kontakt med
eventuell vattenansamling på bottenplåten.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Konfiguration (se
FÖRSIKTIGT
Den lokala inställningen av desinfektionsfunktionen MÅSTE göras av installatören, enligt gällande lagstiftning.
"11Konfiguration"[4125]
)
Installatörens referenshandbok
17
3 | Specifika säkerhetsinstruktioner för installatören
VARNING
Var medveten om att hushållsvarmvattentemperaturen vid varmvattenkranen kommer att motsvara det värde som anges i lokal inställning [2-03] efter en desinfektionsoperation.
Om den höga hushållsvarmvattentemperaturen kan innebära en potentiell risk för skador på människor ska en blandningsventil (anskaffas lokalt) installeras vid hushållsvarmvattenberedarens utloppsanslutning. Blandningsventilen ska säkerställa att varmvattentemperaturen vid varmvattenkranen aldrig överstiger ett angivet maxvärde. Den maximalt tillåtna varmvattentemperaturen ska anges enligt gällande lagstiftning.
FÖRSIKTIGT
Se till att desinfektionsfunktionens starttid [5.7.3] med definierad varaktighet på [5.7.5] INTE avbryts av ett eventuellt varmvattenbehov.
FÖRSIKTIGT
Schema tillåten elpatron [9.4.2] används för att begränsa eller tillåta elpatrondrift baserat på veckoprogram. Råd: för att undvika att desinfektionsfunktionen misslyckas ska du låta elpatronen (i veckoprogrammet) vila i minst 4 timmar för den schemalagda starten av desinfektionen. Om elpatronen är begränsad under desinfektionen kommer desinfektionsfunktionen INTE att fungera och den tillämpliga felkoden AH genereras.
Driftsättning (se
"12Driftsättning"[4225]
VARNING
Driftsättningen MÅSTE göras i enlighet med anvisningarna i denna handbok. Se
"12Driftsättning"[4225].
Underhåll och service (se
FÖRSIKTIGT
Vattnet som kommer ut ur ventilen kan vara kokhett.
VARNING
Om de interna ledningarna är skadade måste de bytas ut av tillverkaren, en serviceagent eller andra kvalificerade personer.
Felsökning (se
"15Felsökning"[4239]
VARNING
Innan en inspektion görs av enhetens kopplingsbox måste enheten ALLTID vara
frånkopplad från nätspänningen. Stäng av respektive strömbrytare.
När ett skydd slagit till, stäng av enheten och ta reda på varför skyddet slog till,
innan du återställer det. Du får ALDRIG koppla förbi skydd eller ändra dem till ett annat värde än det fabriksinställda. Kontakta din installatör om du inte kan hitta orsaken till problemet.
)
"14Underhåll och service"[4236]
)
)
Installatörens referenshandbok
18
FARA: RISK FÖR ELCHOCK
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
3 | Specifika säkerhetsinstruktioner för installatören
VARNING
Förhindra faror till följd av oavsiktlig återställning av det termiska skyddet: strömförsörjning till den här anläggningen FÅR INTE göras via en extern enhet, till exempel en timer. Den får heller inte anslutas till en krets där strömmen regelbundet sätts på och stängs av från elleverantörens sida.
FARA: RISK FÖR BRÄNNSKADA/SKÅLLNING
VARNING
Lufta värmegivare eller uppsamlare. Innan du luftar värmegivare eller uppsamlare
bör du kontrollera om eller visas på användargränssnittets startskärm.
Om inte kan luftningen påbörjas omedelbart.Om det gör det bör du se till att det rum där luftningen ska sker är tillräckligt
ventilerat. Anledning: Köldmedie kan läcka i vattenkretsen och vidare in i rummet när luftning sker från värmegivare och uppsamlare.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Installatörens referenshandbok
19
4 | Om lådan

4 Om lådan

4.1 Översikt: Om lådan

I detta kapitel

4.1 Översikt: Om lådan ................................................................................................................................................................. 20
4.2 Utomhusenheten.................................................................................................................................................................... 20
4.2.1 Hur du hanterar utomhusenheten ........................................................................................................................ 20
4.2.2 Hur du packar upp utomhusenheten .................................................................................................................... 21
4.2.3 Hur du avlägsnar alla tillbehör från utomhusenheten .......................................................................................... 23
Detta kapitel beskriver vad som måste göras när lådan med utomhusenheten levererats till platsen.
Tänk på följande:
Enheten MÅSTE kontrolleras för skador vid leveransen. Eventuella skador SKA
omedelbart anmälas till transportbolagets skaderepresentant.
Placera den förpackade enheten så nära installationsplatsen som möjligt för att
skydda den från transportskador.
Förbered den väg där enheten ska transporteras in.

4.2 Utomhusenheten

4.2.1 Hur du hanterar utomhusenheten

FÖRSIKTIGT
För att undvika skador ska du INTE vidröra enhetens luftintag eller aluminiumflänsar.
Gaffeltruck eller gaffelvagn
När enheten fortfarande befinner sig på pallen ska enheten hanteras med en gaffeltruck eller gaffelvagn.
Installatörens referenshandbok
20
Manuell
Efter uppackningen bärs enheten med lyftremmarna som levereras som tillbehör. Se även:
"Hur du packar upp utomhusenheten"[421]"Hur du avlägsnar alla tillbehör från utomhusenheten"[423]
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
"Så här installerar du utomhusenheten"[471]
a1
a2
a1
a2
±150
kg
1 2
4 | Om lådan

4.2.2 Hur du packar upp utomhusenheten

a1, a2 Lyftremmar
NOTERING
Uppackning – övre förpackning. När du tar bort dem övre förpackningen håller du i
lådan med utloppsgallret för att förhindra att den ramlar i golvet.
1 Ta bort plastfolien och den övre förpackningen.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Installatörens referenshandbok
21
4 | Om lådan
2 Ta ur de utvändiga tillbehören. Se "Hur du avlägsnar alla tillbehör från
utomhusenheten" [4 23]. (Det finns också ett tillbehör inuti enheten som
måste tas bort efter att enheten har öppnats.)
3 Ta bort den övre kartongen och hörnen.
4 Ta bort plastfolien.
Installatörens referenshandbok
22
5 Ta bort transportskruvarna och brickorna.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
M6

4.2.3 Hur du avlägsnar alla tillbehör från utomhusenheten

a
g
d
b c
e
f
ENERG
IJAY
IAIE
ENERG
IJAY
IAIE
h
i
j
1 Ta bort tillbehören ovanpå enheten och på dess framsida.
4 | Om lådan
a Remmar för att bära enheten b Allmänna försiktighetsåtgärder
c Bruksanvisning d Installationshandbok e Tilläggsbok för extrautrustning
f Energietikett g Användargränssnittspaket (frontplåt, bakre plåt, skruvar och väggpluggar) h Utloppsgaller
i Skruvar för utloppsgaller
2 Efter att ha öppnat enheten (se "Hur du öppnar utomhusenheten"[474]) för
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
att ta bort tillbehöret inuti enheten.
Installatörens referenshandbok
23
4 | Om lådan
j Avstängningsventil (med integrerat filter)
Installatörens referenshandbok
24
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06

5 Om enheterna och alternativ

I detta kapitel

5.1 Identifikation........................................................................................................................................................................... 25
5.1.1 Identifikationsetikett: Utomhusenhet ................................................................................................................... 25
5.2 Kombinera enheter och alternativ ......................................................................................................................................... 26
5.2.1 Möjliga tillval för utomhusenheten ....................................................................................................................... 26
5.2.2 Möjliga kombinationer för utomhusenheten och varmvattenberedaren............................................................ 29

5.1 Identifikation

NOTERING
Vid installation eller underhåll av flera enheter samtidigt ska du se till att INTE blanda ihop servicepanelerna för de olika modellerna.

5.1.1 Identifikationsetikett: Utomhusenhet

5 | Om enheterna och alternativ
Plats
Modellidentifiering
Exempel: EBLA16DA3V3
Kod Förklaring
E Monobloc utomhus värmepump
B B=Reversibel (värme+kylning)
D=Endast värme
L Låg vattentemperatur – omgivningszon 2 (se driftintervallet)
A Köldmedium R32
16 Kapacitetsklass
DA Modellserier
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
3 3=Modeller med integrerad reservvärmare
[—]=Modeller utan integrerad reservvärmare
V3 Energitillförsel:
V3=1N~, 230VAC, 50Hz W1=3N~, 400VAC, 50Hz
Installatörens referenshandbok
25
5 | Om enheterna och alternativ

5.2 Kombinera enheter och alternativ

5.2.1 Möjliga tillval för utomhusenheten

Kabelanslutna styrenheter för flera zoner
Du kan ansluta följande kabelanslutna styrenheter för flera zoner:
Basenhet för flera zoner 230V (EKWUFHTA1V3)Digital termostat 230V (EKWCTRDI1V3)Analog termostat 230V (EKWCTRAN1V3)Ställdon 230V (EKWCVATR1V3)
För installationsanvisningar, se installationshandboken till styrenheten och tilläggsboken för extrautrustning.
Rumstermostat (EKRTWA, EKRTR1)
INFORMATION
Vissa alternativ är eventuellt inte tillgängliga i ditt land.
Du kan ansluta en extra rumstermostat till utomhusenheten. Termostaten kan antingen vara fast ansluten (EKRTWA) eller trådlös (EKRTR1).
Se installationshandboken för rumstermostaten för installationsanvisningar och tilläggsboken för extrautrustning.
Fjärrsensor för trådlös termostat (EKRTETS)
Du kan endast använda en trådlös givare för inomhustemperaturen (EKRTETS) i kombination med den trådlösa termostaten (EKRTR1).
Se installationshandboken för rumstermostaten för installationsanvisningar och tilläggsboken för extrautrustning.
Digital I/O-pcb (EKRP1HBAA)
Den digitala I/O pcb:n behövs för följande signaler:
LarmutsignalRumsuppvärmning/-kylning PÅ/AV-utsignalOmställning till extern värmekälla
För installationsanvisningar, se installationshandboken för den digitala I/O pcb:n och tilläggsboken för extrautrustning.
Kretskort för behovsstyrning (EKRP1AHTA)
För att aktivera kontrollen för reducerad strömförbrukning via digitala ingångar måste du installera pcb för behovsstyrning.
Installatörens referenshandbok
26
Installationsanvisningar, se installationshandboken för pcb för behovsstyrning för och tilläggsboken för extrautrustning.
Fjärrsensor för inomhustemperaturen (KRCS01-1)
Som standard kommer den interna sensorn för det dedikerade komfortgränssnittet (BRC1HHDA som används som rumstermostat) användas som rumstemperaturgivare.
Som ett tillval kan fjärrsensorn installeras för att mäta rumstemperaturen på en annan plats.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
5 | Om enheterna och alternativ
För installationsanvisningar, se installationshandboken till fjärrsensorn för inomhustemperaturen och tilläggsboken för extrautrustning.
INFORMATION
Fjärrsensorn för inomhustemperaturen kan endast användas om
användargränssnittet har konfigurerats med rumstermostatfunktionen.
Du kan endast ansluta antingen en fjärrsensor för inomhustemperaturen eller en
fjärrsensor för utomhustemperaturen.
Utomhusfjärrgivare (EKRSCA1)
Som standard används utomhusenhetens givare för att mäta utomhustemperaturen.
Som tillval kan utomhusfjärrgivare installeras för att mäta utomhustemperaturen på en annan plats (t.ex. för att skydda mot direkt solljus) för en bättre systemprestanda.
För installationsanvisningar, se installationshandboken till utomhusfjärrgivaren och tilläggsboken för extrautrustning.
INFORMATION
Du kan endast ansluta antingen en fjärrsensor för inomhustemperaturen eller en fjärrsensor för utomhustemperaturen.
Datorkabel (EKPCCAB4)
PC-kabeln ansluter utomhusenhetens hydrokretskort (A1P) till en dator. Det gör det möjligt att uppdatera hydroprogrammet och EEPROM.
För installationsanvisningar, se:
Installationshandbok för PC-kabeln"Ansluta datorkabeln till kopplingsboxen"[4128]
Värmepumpskonvektor (FWXV, FWXT, FWXM)
För att erhålla rumsuppvärmning/-kyla är det möjligt att använda följande värmepumpskonvektorer:
FWXV: golvplacerad modellFWXT: väggmonterad modellFWXM: dold modell
För installationsanvisningar, se:
Installationshandboken för värmepumpskonvektorernaInstallationshandboken för alternativa värmepumpskonvektorerTilläggsboken för extrautrustning
Extern reservvärmarsats (EKLBUHCB6W1) + shuntventilsats (EKMBHBP1)
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
För modeller utan integrerad reservvärmare går det att installera en extern reservvärmarsats (EKLBUHCB6W1).
För installationsanvisningar, se:
Installationshandbok till den externa reservvärmarsatsen"Ansluta reservvärmarsatsen"[4104] (informationen i detta ämne ersätter delvis
informationen i installationshandboken till reservvärmaren)
Installatörens referenshandbok
27
5 | Om enheterna och alternativ
Om du installerar den externa reservvärmarsatsen måste du också under vissa förhållanden installera en shuntventilsats (EKMBHBP1). Se:
"Krav på shuntventilsats"[4108]"Hur du ansluter shuntventilsatsen"[4109] (informationen i detta ämne ersätter
informationen i det instruktionsark som medföljde shuntventilen)
WLAN-kassett (BRP069A78)
Du kan installera den trådlösa LAN-kassetten för att styra systemet via en smartphone-app.
För installationsanvisningar, se WLAN-kassettens installationshandbok.
Universell central styrenhet (EKCC8-W)
Styrenhet för kaskadstyrning.
Bizonesats (BZKA7V3)
Du kan installera en tillvalsbar sats för dubbelzon. För installationsanvisningar, se installationshandboken för satsen för dubbelzon.
Anslutningssats för tank från tredje part (EKHY3PART)
Krävs vid anslutning av en tank från tredje part till systemet. Innehåller en termistor och en trevägsventil. För installationsanvisningar, se installationshandboken för anslutningssatsen.
Anslutningssats för tank från tredje part med inbyggd termostat (EKHY3PART2)
Sats för anslutning av tank från tredje part med inbyggd termostat till systemet. Satsen konverterar ett termostatbehov från tanken till en begäran om varmvatten för utomhusenheten.
Varmvattenberedare
För att erhålla varmvatten kan en varmvattenberedare anslutas till utomhusenheten.
Följande varmvattenberedare finns tillgängliga:
Tank Remark
Tank av rostfritt stål (standard):
Inklusive elpatronen
EKHWS150D3V3EKHWS180D3V3EKHWS200D3V3EKHWS250D3V3
Installatörens referenshandbok
28
EKHWS300D3V3
Tank av rostfritt stål (+ komponenter):
EKHWSU150D3V3EKHWSU180D3V3EKHWSU200D3V3EKHWSU250D3V3EKHWSU300D3V3
Inklusive:
ElpatronKomponenter som överensstämmer
med de brittiska byggnadsföreskrifterna G3.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
5 | Om enheterna och alternativ
Tank Remark
Polypropentank:
EKHWP300BEKHWP500B
Polypropentank:
EKHWP300PBEKHWP500PB
Tank med drain‑back‑solvärmesystem. För dessa tankar måste tillvalet elpatron
(EKBH3S) vara installerad.
Tank med trycksatt drain‑back‑solvärmesystem.
För dessa tankar måste tillvalet elpatron (EKBH3S) vara installerad.
Se installationshandboken för varmvattenberedaren och tilläggsboken för extrautrustning för installationsanvisningar.
Komfortgränssnitt (BRC1HHDA används som rumstermostat) ▪ Komfortgränssnittet (HCI) som används som rumstermostat kan bara användas i
kombination med andra användargränssnitt som är anslutna till utomhusenheten.
Komfortgränssnittet används som rumstermostat och måste installeras i det rum
du vill reglera.
Se installations- och driftshandboken för komfortgränssnittet (HCI) som rumstermostat för installationsanvisningar och tilläggsboken för extrautrustning.
Flödesbrytare (EKFLSW1)
Om du tillsätter glykol i vattnet måste du även installera en flödesbrytare (och ställa in [E-0D]=1).
För installationsanvisningar, se flödesbrytarens installationshandbok.
Smart Grid-reläsats (EKRELSG)
Installation av Smart grid-reläsatsen (tillval) krävs om Smart Grid-kontakter med högspänning används (EKRELSG).
Se "Ansluta en Smart Grid"[4120] för installationsanvisningar.

5.2.2 Möjliga kombinationer för utomhusenheten och varmvattenberedaren

Kombinationstabell
Utomhusenhet Varmvattenberedare
EKHWS*D* EKHWSU*D* EKHWP* Tank från
EBLA09~16 O O O O
EDLA09~16 O O O O
(a)
Vid användning av en tank från tredje part måste den överensstämma med minimikraven (se "Krav för tank från tredje part"[429]).
tredje part
(a)
(a)
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Krav för tank från tredje part
Om en tank från tredje part används ska tanken uppfylla följande krav:
Tankens värmeväxlarspole är ≥1,05m² och ≥3,7m².Tankens termistor måste vara placerad ovanför värmeväxlarspolen.Elpatronen måste vara placerad ovanför värmeväxlarspolen.
Installatörens referenshandbok
29
5 | Om enheterna och alternativ
aba
b
För mer detaljerade installationsanvisningar, se installationshandboken för anslutningssatsen och tilläggsboken för extrautrustning.
NOTERING
Prestanda. Vi KAN INTE tillhandahålla prestandadata eller garantera prestandan för
tankar från tredje part.
Om du har en tank där du...
kan föra in en termistor. INTE KAN föra in en termistor.
Använd EKHY3PART. Använd EKHY3PART2.
a Utomhusenhet
b Tank
Installatörens referenshandbok
30
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Loading...