Daikin EBLA09~16DAV3, EBLA09~16DAW1, EBLA09~16DA3V3, EBLA09~16DA3W1, EDLA09~16DAV3 Installer reference guide [sl]

...
Vodnik za monterja
https://daikintechnicaldatahub.eu
Daikin Altherma 3 M
EBLA09~16DAV3 EBLA09~16DAW1 EBLA09~16DA3V3 EBLA09~16DA3W1
EDLA09~16DAV3 EDLA09~16DAW1 EDLA09~16DA3V3 EDLA09~16DA3W1

Kazalo

Kazalo
1 O dokumentaciji 5
1.1 O tem dokumentu........................................................................................................................................................... 5
1.2 Pomen opozoril in simbolov ........................................................................................................................................... 6
1.3 Kratek pregled referenčnega vodnika za monterja........................................................................................................ 7
2 Splošni varnostni ukrepi 9
2.1 Za monterja..................................................................................................................................................................... 9
2.1.1 Splošno ........................................................................................................................................................... 9
2.1.2 Mesto namestitve........................................................................................................................................... 10
2.1.3 Hladivo — v primeru R410A ali R32 ............................................................................................................... 10
2.1.4 Voda ................................................................................................................................................................ 12
2.1.5 Električna dela ................................................................................................................................................ 12
3 Specifična varnostna navodila za monterja 15
4 O škatli 20
4.1 Pregled: O škatli .............................................................................................................................................................. 20
4.2 Zunanja enota ................................................................................................................................................................. 20
4.2.1 Prenašanje zunanje enote .............................................................................................................................. 20
4.2.2 Razpakiranje zunanje enote ........................................................................................................................... 21
4.2.3 Odstranjevanje opreme iz zunanje enote...................................................................................................... 23
5 O enotah in opcijskih dodatkih 25
5.1 Oznaka............................................................................................................................................................................. 25
5.1.1 Nazivna ploščica: zunanja enota .................................................................................................................... 25
5.2 Kombiniranje enot in možnosti ...................................................................................................................................... 26
5.2.1 Možni opcijski dodatki za zunanjo enoto....................................................................................................... 26
5.2.2 Možne kombinacije zunanje enote in rezervoarja za toplo vodo za gospodinjstvo ..................................... 29
6 Napotki za uporabo 31
6.1 Pregled: napotki za uporabo........................................................................................................................................... 31
6.2 Nastavitev sistema za ogrevanje/hlajenje prostora....................................................................................................... 32
6.2.1 Posamezni prostor.......................................................................................................................................... 33
6.2.2 Več prostorov –eno območje temperature izhodne vode ........................................................................... 37
6.2.3 Več prostorov –dve območji temperature izhodne vode............................................................................. 43
6.3 Nastavitev pomožnega vira toplote za ogrevanje prostora........................................................................................... 46
6.4 Nastavitev rezervoarja za toplo vodo za gospodinjstvo................................................................................................. 49
6.4.1 Postavitev sistema –samostojni rezervoar za toplo vodo za gospodinjstvo ................................................ 49
6.4.2 Izbiranje prostornine in želene temperature za rezervoar za toplo vodo za gospodinjstvo ........................ 49
6.4.3 Nastavitev in konfiguracija –rezervoar za toplo vodo za gospodinjstvo ...................................................... 51
6.4.4 Črpalka za toplo vodo za gospodinjstvo za takojšnjo toplo vodo.................................................................. 52
6.4.5 Črpalka za toplo vodo za gospodinjstvo za dezinfekcijo ................................................................................ 53
6.4.6 Črpalka za DHW za predgrevanje rezervoarja ............................................................................................... 53
6.5 Nastavitev merjenja energije.......................................................................................................................................... 54
6.5.1 Proizvedena toplota ....................................................................................................................................... 55
6.5.2 Porabljena energija......................................................................................................................................... 55
6.5.3 Postavitve napajanja s števci električne energije .......................................................................................... 56
6.6 Nastavitev nadzora energijske porabe ........................................................................................................................... 61
6.6.1 Trajna omejitev električne energije ............................................................................................................... 61
6.6.2 Omejitev električne energije, ki se aktivira z digitalnimi vhodi ..................................................................... 62
6.6.3 Postopek omejitve električne energije .......................................................................................................... 63
6.6.4 Omejitev električne energije BBR16 .............................................................................................................. 64
6.7 Nastavitev zunanjega tipala temperature...................................................................................................................... 65
7 Montaža enote 67
7.1 Priprava mesta namestitve............................................................................................................................................. 67
7.1.1 Zahteve za namestitveno mesto za zunanjo enoto ....................................................................................... 67
7.1.2 Dodatne zahteve za namestitveno mesto za zunanjo enoto v hladnih predelih.......................................... 70
7.2 Nameščanje zunanje enote ............................................................................................................................................ 70
7.2.1 O nameščanju zunanje enote......................................................................................................................... 70
7.2.2 Varnostni ukrepi pri nameščanju zunanje enote ........................................................................................... 71
7.2.3 Priprava montažne konstrukcije .................................................................................................................... 71
7.2.4 Montaža zunanje enote ................................................................................................................................. 71
7.2.5 Priprava drenaže............................................................................................................................................. 72
7.2.6 Montaža izpustne rešetke .............................................................................................................................. 74
7.3 Odpiranje in zapiranje enote .......................................................................................................................................... 74
Vodnik za monterja
2
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Kazalo
7.3.1 Odpiranje enot................................................................................................................................................ 74
7.3.2 Odpiranje zunanje enote................................................................................................................................ 75
7.3.3 Zapiranje zunanje enote................................................................................................................................. 75
8 Montaža cevi 76
8.1 Priprava vodovodnih cevi................................................................................................................................................ 76
8.1.1 Zahteve za vodovodni krog ............................................................................................................................ 76
8.1.2 Formula za izračun predtlaka ekspanzijske posode....................................................................................... 79
8.1.3 Preverjanje količine vode in hitrosti pretoka ................................................................................................. 79
8.1.4 Spreminjanje predtlaka ekspanzijske posode ................................................................................................ 82
8.1.5 Preverjanje količine vode: primeri ................................................................................................................. 82
8.2 Priključevanje vodovodnih cevi ...................................................................................................................................... 83
8.2.1 Priključevanje cevi za vodo............................................................................................................................. 83
8.2.2 Napotki za varnost pri priključevanju vodovodnih cevi ................................................................................. 83
8.2.3 Priključevanje vodovodnih cevi ...................................................................................................................... 83
8.2.4 Zaščita vodovodnega kroga pred zmrzovanjem ............................................................................................ 85
8.2.5 Polnjenje vodovodnega kroga ........................................................................................................................ 88
8.2.6 Polnjenje rezervoarja za toplo vodo za gospodinjstvo .................................................................................. 88
8.2.7 Izoliranje vodovodnih cevi.............................................................................................................................. 88
9 Električna napeljava 90
9.1 O priključevanju električnega ožičenja........................................................................................................................... 90
9.1.1 Napotki za varnost pri priključevanju električnega ožičenja ......................................................................... 90
9.1.2 Napotki za priključevanje električnega ožičenja ............................................................................................ 91
9.1.3 O električni skladnosti .................................................................................................................................... 92
9.1.4 O napajanju po prednostni tarifi za kWh električne energije........................................................................ 92
9.1.5 Pregled električnih priključkov, razen za zunanje aktuatorje ........................................................................ 93
9.2 Povezave na zunanjo enoto............................................................................................................................................ 95
9.2.1 Da bi povezali električno ožičenje na zunanjo enoto .................................................................................... 99
9.2.2 Priključevanje omrežnega napajanja ............................................................................................................. 100
9.2.3 Priključevanje napajanja za rezervni grelnik .................................................................................................. 103
9.2.4 Komplet zunanjega rezervnega grelnika........................................................................................................ 104
9.2.5 Priključevanje uporabniškega vmesnika ........................................................................................................ 110
9.2.6 Priključevanje zapornega ventila.................................................................................................................... 114
9.2.7 Priključevanje števcev električne energije ..................................................................................................... 115
9.2.8 Priključevanje črpalke za toplo vodo za gospodinjstvo ................................................................................. 115
9.2.9 Priključevanje izhoda za alarm ....................................................................................................................... 116
9.2.10 Priključevanje izhoda za vklop/izklop ogrevanja/hlajenja prostora .............................................................. 117
9.2.11 Priključevanje preklopa na zunanji vir toplote............................................................................................... 118
9.2.12 Priključevanje digitalnih vhodov za porabo energije..................................................................................... 119
9.2.13 Priključitev varnostnega termostata (običajno zaprt kontakt)...................................................................... 120
9.2.14 Priključitev pametnega električnega omrežja................................................................................................ 121
10 Zaključevanje montaže zunanje enote 125
10.1 Da bi preverili upornost izolacije kompresorja............................................................................................................... 125
11 Konfiguracija 126
11.1 Pregled: konfiguracija ..................................................................................................................................................... 126
11.1.1 Dostopanje do najpogosteje uporabljanih ukazov ........................................................................................ 127
11.1.2 Priključitev računalniškega kabla v stikalno omarico..................................................................................... 129
11.2 Čarovnik za konfiguracijo................................................................................................................................................ 130
11.3 Možni zasloni .................................................................................................................................................................. 131
11.3.1 Možni zasloni: pregled.................................................................................................................................... 131
11.3.2 Začetni zaslon ................................................................................................................................................. 132
11.3.3 Zaslon glavnega menija .................................................................................................................................. 135
11.3.4 Zaslon menija.................................................................................................................................................. 136
11.3.5 Zaslon z nastavitveno točko ........................................................................................................................... 136
11.3.6 Zaslon s podrobnostmi vrednosti................................................................................................................... 137
11.4 Prednastavljene vrednosti in urniki................................................................................................................................ 138
11.4.1 Uporaba prednastavljenih vrednosti ............................................................................................................. 138
11.4.2 Uporaba in programiranje urnikov................................................................................................................. 138
11.4.3 Zaslon z urnikom: primer................................................................................................................................ 142
11.4.4 Nastavitev cen energije .................................................................................................................................. 146
11.5 Krivulja za vremensko vodeno upravljanje..................................................................................................................... 148
11.5.1 Kaj je krivulja za vremensko vodeno upravljanje? ......................................................................................... 148
11.5.2 2-točkovna krivulja ......................................................................................................................................... 149
11.5.3 Krivulja z naklonom in zamikom..................................................................................................................... 150
11.5.4 Uporaba krivulj za vremensko vodeno delovanje.......................................................................................... 151
11.6 Meni z nastavitvami........................................................................................................................................................ 153
11.6.1 Okvara............................................................................................................................................................. 153
11.6.2 Prostor ............................................................................................................................................................ 154
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Vodnik za monterja
3
Kazalo
11.6.3 Glavno območje.............................................................................................................................................. 159
11.6.4 Dodatno območje........................................................................................................................................... 168
11.6.5 Ogrevanje/hlajenje prostora .......................................................................................................................... 173
11.6.6 Rezervoar........................................................................................................................................................ 182
11.6.7 Uporabniške nastavitve.................................................................................................................................. 190
11.6.8 Informacije...................................................................................................................................................... 195
11.6.9 Nastavitve monterja ....................................................................................................................................... 196
11.6.10 Zagon .............................................................................................................................................................. 223
11.6.11 Delovanje........................................................................................................................................................ 223
11.6.12 Omrežje WLAN ............................................................................................................................................... 224
11.7 Struktura menija: pregled uporabniških nastavitev....................................................................................................... 226
11.8 Struktura menija: pregled nastavitev monterja............................................................................................................. 227
12 Zagon 228
12.1 Pregled: zagon................................................................................................................................................................. 228
12.2 Napotki za varnost pri zagonu........................................................................................................................................ 229
12.3 Seznam preverjanj pred zagonom.................................................................................................................................. 229
12.4 Seznam preverjanj med zagonom.................................................................................................................................. 230
12.4.1 Minimalna hitrost pretoka ............................................................................................................................. 230
12.4.2 Funkcija odzračevanja .................................................................................................................................... 231
12.4.3 Testni zagon delovanja................................................................................................................................... 233
12.4.4 Testni zagon aktuatorjev ................................................................................................................................ 234
12.4.5 Sušenje estriha s talnim ogrevanjem ............................................................................................................. 235
13 Izročitev uporabniku 238
14 Vzdrževanje in servisiranje 239
14.1 Varnostni ukrepi za vzdrževanje..................................................................................................................................... 239
14.2 Letno vzdrževanje........................................................................................................................................................... 239
14.2.1 Letno vzdrževanje zunanje enote: pregled.................................................................................................... 239
14.2.2 Letno vzdrževanje zunanje enote: navodila................................................................................................... 240
15 Odpravljanje težav 242
15.1 Pregled: Odpravljanje težav............................................................................................................................................ 242
15.2 Varnostni ukrepi pri odpravljanju težav ......................................................................................................................... 242
15.3 Reševanje težav na podlagi simptomov ......................................................................................................................... 243
15.3.1 Simptom: Enota NE ogreva oziroma ne hladi po pričakovanjih .................................................................... 243
15.3.2 Simptom: Topla voda NE doseže želene temperature .................................................................................. 243
15.3.3 Simptom: Kompresor se NE zažene (ogrevanje prostora ali ogrevanje vode za gospodinjstvo) ................. 244
15.3.4 Simptom: Po zagonu se v sistemu pojavlja klokotajoč zvok.......................................................................... 245
15.3.5 Simptom: Črpalka je blokirana ....................................................................................................................... 245
15.3.6 Simptom: Črpalka ropota (kavitacija)............................................................................................................. 246
15.3.7 Simptom: Odpre se ventil za sproščanje tlaka............................................................................................... 246
15.3.8 Simptom: Ventil za sproščanje vodnega tlaka pušča..................................................................................... 246
15.3.9 Simptom: Prostor se NE ogreje v zadostni meri pri nizkih zunanjih temperaturah...................................... 247
15.3.10 Simptom: Tlak na točilnem mestu je začasno nenavadno visok ................................................................... 248
15.3.11 Simptom: Funkcija dezinfekcije rezervoarja se NE izvede pravilno (napaka AH).......................................... 248
15.4 Odpravljanje težav na podlagi kod napake..................................................................................................................... 248
15.4.1 Prikaz besedila pomoči v primeru okvare ...................................................................................................... 249
15.4.2 Kode napake enote......................................................................................................................................... 249
16 Odstranjevanje 255
16.1 Zbiranje hladiva............................................................................................................................................................... 255
16.1.1 Odpiranje zapornih ventilov........................................................................................................................... 256
16.1.2 Ročno odpiranje elektronskih ekspanzijskih ventilov .................................................................................... 256
16.1.3 Način zbiranja – pri modelih 3N~ (7-segmentni prikazovalnik)..................................................................... 257
16.1.4 Način zbiranja – pri modelih 1N~ (prikazovalnik s 7 LED-indikatorji)............................................................ 260
17 Tehnični podatki 262
17.1 Prostor za vzdrževanje: Zunanja enota .......................................................................................................................... 263
17.2 Shema napeljave cevi: zunanja enota ............................................................................................................................ 265
17.3 Vezalna shema: zunanja enota....................................................................................................................................... 267
Vodnik za monterja
4
18 Slovar 276
19 Tabela z nastavitvami sistema 277
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06

1 O dokumentaciji

V tem poglavju

1.1 O tem dokumentu .................................................................................................................................................................. 5
1.2 Pomen opozoril in simbolov................................................................................................................................................... 6
1.3 Kratek pregled referenčnega vodnika za monterja ............................................................................................................... 7

1.1 O tem dokumentu

Ciljni prejemniki
Pooblaščeni monterji
Komplet dokumentacije
Ta dokument je del kompleta dokumentacije. Celotno dokumentacijo sestavljajo:
Splošni napotki za varnost:
- Varnostna navodila, ki jih morate prebrati pred montažo
- Format: Papirni izvod (v škatli zunanje enote)
1 | O dokumentaciji
Priročnik za uporabo:
- Kratka navodila za osnovno uporabo
- Format: Papirni izvod (v škatli zunanje enote)
Vodnik za uporabnika:
- Podrobna navodila po korakih in dopolnilne informacije za osnovno in
napredno uporabo
- Format: Digitalne datoteke so na voljo na naslovu http://
www.daikineurope.com/support-and-manuals/product-information/
Priročnik za montažo:
- Navodila za montažo
- Format: Papirni izvod (v škatli zunanje enote)
Vodnik za monterja:
- Priprava za montažo, dobre prakse, referenčni podatki…
- Format: Digitalne datoteke so na voljo na naslovu http://
www.daikineurope.com/support-and-manuals/product-information/
Dodatek za opcijsko opremo:
- Dodatne informacije za montažo opcijske opreme
- Format: Papirni izvod (v škatli zunanje enote) + Digitalne datoteke so na voljo
na naslovu http://www.daikineurope.com/support-and-manuals/product-
information/
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
V območnem spletnem mestu Daikin ali pri vašem prodajalcu so morda na voljo najnovejše posodobitve priložene dokumentacije.
Izvorna dokumentacija je pisana v angleščini. Dokumentacija v drugih jezikih je prevod.
Tehnično-inženirski podatki
Povzetek najnovejših tehničnih podatkov je na voljo na regionalni Daikin spletni
strani (javno dostopna).
Vodnik za monterja
5
1 | O dokumentaciji
Popolni tehnični podatki so na voljo na Daikin Business Portal (zahtevana
avtentikacija).
Spletna orodja
Poleg kompleta dokumentacije so za monterje na voljo nekatera spletna orodja:
Daikin Technical Data Hub
- Osrednje vozlišče za tehnične specifikacije enote, uporabna orodja, digitalne
vire in še mnogo več.
- Javno dostopno na spletnem mestu https://daikintechnicaldatahub.eu.
Heating Solutions Navigator
- Digitalna orodjarna, ki nudi različna orodja, ki omogočajo montažo in
konfiguracijo sistemov za ogrevanje.
- Za dostop do Heating Solutions Navigator je potrebna platforma Stand By Me.
Za več informacij glejte https://professional.standbyme.daikin.eu.
Daikin e-Care
- Mobilna aplikacija za monterje in servisne tehnike, ki vam omogoča
registriranje in konfiguriranje sistemov za ogrevanje ter odpravljanje težav.
- Z uporabo spodnje kode QR je mobilno aplikacijo mogoče prenesti za naprave s
sistemom iOS in Android. Za dostop do aplikacije je potrebna registracija na platformi Stand By Me.
App Store Google Play

1.2 Pomen opozoril in simbolov

NEVARNOST
Označuje situacijo, ki vodi v smrt in hude telesne poškodbe.
NEVARNOST: SMRTNA NEVARNOST ZARADI ELEKTRIČNEGA UDARA
Označuje situacijo, ki lahko povzroči smrt zaradi električnega udara.
NEVARNOST: TVEGANJE ZA OŽGANINE/OPEKLINE
Prikazuje situacijo, ki bi lahko povzročila ožganine/opekline zaradi izjemno visokih ali nizkih temperatur.
NEVARNOST: NEVARNOST EKSPLOZIJE
Označuje situacijo, ki lahko povzroči eksplozijo.
Vodnik za monterja
6
OPOZORILO
Označuje situacijo, ki lahko povzroči smrt in hude telesne poškodbe.
OPOZORILO: VNETLJIV MATERIAL
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
POZOR
Označuje situacijo, ki lahko povzroči manjše ali srednje nevarne telesne poškodbe.
OPOMBA
Označuje situacijo, ki lahko povzroči poškodbe opreme ali lastnine.
INFORMACIJE
Označuje uporabne nasvete ali dodatne informacije.
Simboli, uporabljeni na enoti:
Simbol Razlaga
Pred namestitvijo preberite navodila za montažo in uporabo ter shemo z navodili za ožičenje.
Preden začnete izvajati vzdrževalne in servisne postopke preberite priročnik za servisiranje.
Za več informacij glejte vodnik za monterja in uporabnika.
1 | O dokumentaciji
Enota vsebuje vrtljive dele. Pri servisiranju in pregledovanju bodite pazljivi.
Simboli, uporabljeni v dokumentaciji:
Simbol Razlaga
Pomeni naslov slike ali sklic nanjo. Primer: " 1–3 naslov slike" pomeni "3. slika v 1. poglavju".
Pomeni naslov tabele ali sklic nanjo. Primer: " 1–3 naslov tabele" pomeni "3. tabela v 1.
poglavju".

1.3 Kratek pregled referenčnega vodnika za monterja

Poglavje Opis
O dokumentaciji Dokumentacija za monterja
Splošni napotki za varnost Varnostna navodila, ki jih morate prebrati pred
Posebna navodila za varnost monterja
montažo
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
O škatli Ravnanje s škatlo, razpakiranje enot in
odstranjevanje njihove opreme
O enotah in opcijskih dodatkih Prepoznavanje enot
Možne kombinacije enot in opcijskih dodatkov
Napotki za uporabo Različne možnosti namestitve sistema
Montaža enote Kaj je treba narediti in vedeti za montažo
sistema, vključno z informacijami za priprave na montažo
Vodnik za monterja
7
1 | O dokumentaciji
Poglavje Opis
Montaža cevi Kaj je treba narediti in vedeti za montažo cevi
sistema, vključno z informacijami za priprave na montažo
Električna napeljava Kaj je treba narediti in vedeti za montažo
električnih komponent sistema, vključno z informacijami za priprave na montažo
Zaključevanje montaže zunanje enote
Kaj je treba narediti po montaži enote, cevi in električne napeljave
Konfiguracija Kaj morate narediti in kaj morate vedeti za
konfiguracijo sistema po montaži
Zagon Kaj morate narediti in kaj morate vedeti za
zagon sistema po konfiguraciji
Izročitev uporabniku Kaj morate izročiti in kaj razložiti uporabniku
Vzdrževanje in servisiranje Vzdrževanje in servisiranje enot
Odpravljanje težav Ukrepi v primeru težav
Odstranjevanje Odstranitev sistema
Tehnični podatki Specifikacije sistema
Slovar Opredelitev pojmov
Tabela z nastavitvami sistema Tabela, ki jo izpolni monter in jo mora uporabnik
hraniti za prihodnjo rabo Opomba: Tabela z nastavitvami monterja je tudi
v vodniku za monterja. Monter mora to tabelo izpolniti in jo izročiti uporabniku.
Vodnik za monterja
8
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06

2 Splošni varnostni ukrepi

V tem poglavju

2.1 Za monterja............................................................................................................................................................................. 9
2.1.1 Splošno ................................................................................................................................................................... 9
2.1.2 Mesto namestitve .................................................................................................................................................. 10
2.1.3 Hladivo — v primeru R410A ali R32....................................................................................................................... 10
2.1.4 Voda........................................................................................................................................................................ 12
2.1.5 Električna dela ........................................................................................................................................................ 12

2.1 Za monterja

2.1.1 Splošno

Če NISTE prepričani, kako montirati ali upravljati enoto, se obrnite na svojega prodajalca.
NEVARNOST: TVEGANJE ZA OŽGANINE/OPEKLINE
NE dotikajte se cevi za hladivo, cevi za vodo in notranjih delov med delovanjem ali
neposredno po delovanju. Lahko so prevroči ali premrzli. Počakajte, da se njihova temperatura normalizira. Če se jih morate dotikati, si nadenite zaščitne rokavice.
Z golo kožo se NE dotikajte ponesreči razlitega hladiva.
2 | Splošni varnostni ukrepi
OPOZORILO
Nestrokovna montaža ali priklop naprave in opreme lahko povzroči električni udar, kratek stik, uhajanje tekočin ali požar ali drugače poškoduje napravo ali opremo. Uporabljajte samo dodatke, opcijsko opremo in nadomestne dele, ki jih izdela ali odobri Daikin.
OPOZORILO
Montaža, preizkus in uporabljeni materiali morajo biti (razen z navodili, opisanimi v dokumentaciji Daikin) skladni tudi z veljavno zakonodajo.
POZOR
Pri nameščanju, vzdrževanju ali servisiranju sistema uporabljajte ustrezno osebno zaščitno opremo (zaščitne rokavice, varnostna očala…).
OPOZORILO
Raztrgajte in odvrzite plastične vreče, da se z njimi nihče ne bi mogel igrati, zlasti ne otroci. Možna nevarnost: zadušitev.
OPOZORILO
Z zagotavljanjem primernih ukrepov preprečite, da bi enota postala zavetišče za majhne živali. Majhne živali, ki se dotaknejo električnih delov, lahko povzročijo okvare, dim ali požar.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
POZOR
Ne dotikajte se odprtine za vstop zraka ali aluminijastih platic enote.
Vodnik za monterja
9
2 | Splošni varnostni ukrepi
V skladu z zadevno zakonodajo bo treba morda skupaj z izdelkom priskrbeti dnevnik, v katerem se beležijo najmanj: podatki o vzdrževanju, popravila, rezultati testov, obdobja pripravljenosti…
Najmanj naslednje informacije MORAJO biti zagotovljene na dostopnem mestu izdelka:
Navodila za izklop sistema v nujnem primeruNaziv in naslov gasilske službe, policije in bolnišniceIme, naslov ter dnevna in nočna telefonska številka za servis
Potrebne smernice za tak dnevnik za Evropo podaja standard EN378.
POZOR
Na vrh enote NE postavljajte predmetov ali opreme.NE sedite na napravi, ne plezajte nanjo in ne stojte na njej.
OPOMBA
Dela na zunanji enoti je najbolje opraviti v suhem vremenu, da bi se izognili vdoru vode.

2.1.2 Mesto namestitve

Zagotovite dovolj prostora okoli enote za servisiranje in kroženje zraka.Prepričajte se, da mesto namestitve prenese težo in vibracije enote.Prepričajte se, da je območje dobro prezračeno. NE blokirajte prezračevalnih
odprtin.
Pazite, da bo enota izravnana.
Enote NE nameščajte na naslednja mesta:
V potencialno eksplozivnem okolju.Na mestih, kjer so stroji, ki oddajajo elektromagnetne valove. Elektromagnetni
valovi lahko motijo krmilni sistem in lahko povzročijo okvare na opremi.
Na mestih, kjer obstaja nevarnost požara zaradi uhajanja vnetljivih plinov
(primer: razredčilo ali bencin), ogljikovih vlaken ali vnetljivega prahu.
Na mestih, kjer nastajajo korozivni plini (primer: kisli žvepleni plin). Zaradi
korozije bakrenih cevi ali zvarov bi lahko začelo puščati hladivo.

2.1.3 Hladivo — v primeru R410A ali R32

Če se uporablja. Za več informacij glejte priročnik za montažo ali referenčni vodnik za monterja za vašo uporabo.
Vodnik za monterja
10
OPOMBA
Napeljava cevi mora biti skladna z veljavno zakonodajo. Zadevni standard za Evropo je EN378.
OPOMBA
Poskrbite, da zunanje cevi in priključki NE bodo obremenjeni.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
2 | Splošni varnostni ukrepi
OPOZORILO
Med testiranjem v izdelku NIKOLI ne smete vzpostaviti tlaka, višjega od maksimalnega dovoljenega tlaka (ki je naveden na nazivni ploščici enote).
OPOZORILO
Poskrbite za ustrezne varnostne ukrepe za primer puščanja hladiva. Če med nameščanjem izteče hladilno sredstvo v plinastem stanju, takoj prezračite prostor. Možna tveganja:
Prevelika koncentracija hladiva v zaprtem prostoru lahko privede do pomanjkanja
kisika.
Če pride plinasto hladivo v stik z ognjem, lahko nastanejo strupeni plini.
NEVARNOST: NEVARNOST EKSPLOZIJE
Izčrpavanje – Puščanje hladiva. Če želite sistem izčrpati in nekje na tokokrogu
hladilnega sredstva pušča:
NE uporabljajte funkcije za samodejno izčrpavanje na enoti, s katero lahko
zberete vse hladivo iz sistema v zunanji enoti. Možna posledica: Samoizgorevanje in eksplozija kompresorja zaradi zraka, ki pride v delujoč kompresor.
Uporabite ločen sistem za izčrpavanje, tako da kompresorju enote NI treba
delovati.
OPOZORILO
Hladivo VEDNO zberite. NE izpuščajte jih neposredno v okolje. Uporabite vakuumsko črpalko, da boste izpraznili napeljavo.
OPOMBA
Ko so vse cevi priključene, se prepričajte, da plin ne uhaja. S pomočjo dušika preverite, ali plin uhaja.
OPOMBA
Preprečevanje okvare kompresorja, NE dolijte več hladiva, kot je navedeno v
specifikaciji.
Kadar je treba sistem hladiva odpreti, morate s hladivom ravnati v skladu z
zadevno zakonodajo.
OPOZORILO
Pazite, da v sistemu ni kisika. Hladivo lahko natočite šele, ko opravite preizkus tesnjenja in vakuumsko praznjenje.
Možna posledica: Samovžig in eksplozija kompresorja zaradi vstopa kisika v delujoči kompresor.
Če je to potrebno, preverite napisno ploščico na enoti. Na njej sta navedena tip
hladiva in potrebna količina.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Enota je tovarniško napolnjena s hladivom. Odvisno od velikosti in dolžine cevi je
treba v nekaterih sistemih dotočiti hladivo.
Da bi zagotovili upornost tlaka in preprečili vdor drugih snovi v sistem,
uporabljajte samo orodje, zasnovano posebej za vrsto hladiva, uporabljeno v sistemu.
Hladivo točite upoštevaje naslednje:
Vodnik za monterja
11
2 | Splošni varnostni ukrepi
Če Potem
Je prisotna sifonska cev (tj., na jeklenki je oznaka “Liquid filling
Pri polnjenju mora biti jeklenka postavljena pokonci.
siphon attached” (pritrjena sifonska cev za tekoče hladivo))
Sifonska cev NI prisotna Pri polnjenju mora biti jeklenka
obrnjena na glavo.
Počasi odprite vsebnike hladiva.Hladivo točite v tekočem stanju. Dodajanje hladiva v plinskem stanju lahko
onemogoči normalno delovanje.
POZOR
Ko je postopek dolivanja hladiva dokončan ali ga prekinete, takoj zaprite ventil rezervoarja za hladivo. Če se ventil NE zapre takoj, lahko preostanek tlaka napolni dodatno hladivo. Možna posledica: Nepravilna količina hladiva.

2.1.4 Voda

2.1.5 Električna dela

Če se uporablja. Za več informacij glejte priročnik za montažo ali referenčni vodnik za monterja za vašo uporabo.
OPOMBA
Kakovost vode mora ustrezati Direktivi EU 98/83ES.
NEVARNOST: SMRTNA NEVARNOST ZARADI ELEKTRIČNEGA UDARA
Izključite vse napajanje, preden snamete pokrov stikalne omarice, priključujete
električno napeljavo ali se dotikate električnih delov.
Odklopite napajanje za več kot 10 minut ter izmerite napetost na priključnih
sponkah kondenzatorjev glavnega tokokroga ali električnih sestavnih delih, preden začnete servisiranje. Napetost mora biti nižja od 50VDC, preden se lahko dotaknete električnih sestavnih delov. Za mesto priključnih sponk glejte vezalno shemo.
Električnih sestavnih delov se NE dotikajte z mokrimi rokami.Enote NE puščajte brez nadzora, če ste z nje odstranili servisni pokrov.
Vodnik za monterja
12
OPOZORILO
Če NI nameščeno, JE NUJNO v fiksno ožičenje namestiti glavno stikalo ali druge možnosti odklopa, ki imajo ločen stik na vseh polih in omogočajo popolni odklop v pogojih previsoke napetosti kategorijeIII.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
2 | Splošni varnostni ukrepi
OPOZORILO
Uporabljajte LE bakrene vodnike.Pazite, da bodo električne napeljave ustrezale veljavni zakonodaji.Vse lokalno ožičenje mora biti izvedeno skladno z vezalno shemo, priloženo
izdelku.
NIKOLI ne stiskajte šopov kablov in pazite, da NE pridejo v stik s cevmi ali z ostrimi
robovi. Prepričajte se, da na priključne sponke ne pritiska nič z zunanje strani.
Pazite, da boste zagotovo namestili ozemljitveni vodnik. Ne ozemljujte naprave s
pomočjo komunalne cevi, prenapetostnega odvodnika ali ozemljitve telefona. Nepopolna ozemljitev lahko povzroči električni šok.
Zagotovo uporabite ločeno električno vezje. NIKOLI ne delite vira napajanja z
drugo napravo.
Pazite, da boste zagotovo namestili zahtevane varovalke ali prekinjala vezij.Zagotovo namestite odklopnik z uhajanjem toka. Če tega ne storite, lahko pride
do električnega udara ali požara.
Ko nameščate zemljostično zaščito, pazite, da je združljiva z inverterjem (odporna
na visokofrekvenčne električne šume), da bi se izognili nepotrebnemu odpiranju zaščite.
POZOR
Ko priključujete napajanje: najprej povežite ozemljitev, nato pa izvedite povezave
za prenos električnega toka.
Ko izključujete napajanje: najprej odklopite povezave za prenos električnega toka,
nato pa še ozemljitev.
Dolžina vodnikov med oporo napajalnega kabla in samim prikjučnim blokom mora
biti taka, da so napajalni vodniki napeti pred ozemljitvenim vodnikom, za primer, da bi se napajalni kabel snel z opore kabla.
OPOMBA
Varnostni ukrepi pri napeljavi napajalnih vodnikov:
NE priključujte vodnikov različnih debelin na priključne sponke napajanja
(ohlapnost napajalnih vodnikov lahko povzroči neobičajno segrevanje).
Pri priključevanju vodnikov enake debeline naredite tako, kot je prikazano na sliki
zgoraj.
Za ožičenje uporabite predvideni napajalni vodnik in ga trdno priključite, nato pa
zavarujte, da bi preprečili, da se zunanja sila prenese na priključno ploščo.
Uporabite ustrezen izvijač za privijanje vijakov na priključku. Izvijač z malim
nastavkom lahko poškoduje glavo vijaka in onemogoči ustrezno zategovanje.
S premočnim zategovanjem lahko vijake na priključkih polomite.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Električne kable napeljite najmanj 1 m stran od televizije in radia, da bi preprečili motnje. Odvisno od radijskih valov, tudi 1m morda ne bo dovolj.
OPOZORILO
Ko zaključite napeljavo električnih kablov, se prepričajte, da so vsi električni
sestavni deli in vse priključne sponke v omarici z električnimi sestavnimi deli varno pritrjeni.
Obvezno zaprite vse pokrove, preden zaženete enoto.
Vodnik za monterja
13
2 | Splošni varnostni ukrepi
OPOMBA
Velja samo, če je napajanje trifazno in je način zagona kompresorja VKLOP/IZKLOP.
Če obstaja možnost, da bi do obrnjene faze prišlo po trenutnem izpadu in se napajanje vklaplja in izklaplja med delovanjem izdelka, priključite vezje za zaščito pred obrnjeno fazo lokalno. Delovanje izdelka z obrnjeno fazo lahko povzroči okvaro kompresorja in drugih delov.
Vodnik za monterja
14
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
3 | Specifična varnostna navodila za monterja

3 Specifična varnostna navodila za monterja

Vedno upoštevajte naslednje varnostne ukrepe in predpise.
Ravnanje z enoto (glejte
"Prenašanje zunanje enote"[420]
POZOR
Da se izognete telesnim poškodbam, se NE dotikajte dovoda zraka ali aluminijastih reber na enoti.
Napotki za uporabo (glejte
"6Napotki za uporabo"[431]
POZOR
Če se uporablja več kot eno območje izhodne vode, v glavno območje VEDNO vgradite postajo z mešalnim ventilom za zmanjšanje (pri ogrevanju)/povečanje (pri hlajenju) temperature izhodne vode, ko obstaja zahteva v dodatnem območju.
Mesto namestitve (glejte
"7.1Priprava mesta namestitve"[467]
OPOZORILO
Upoštevajte mere prostora za vzdrževanje v tem priročniku za pravilno nameščanje enote. Glejte "17.1Prostor za vzdrževanje: Zunanja enota"[4263].
Posebne zahteve za R32 (glejte
enoto"[467]
)
)
)
)
"Zahteve za namestitveno mesto za zunanjo
OPOZORILO
NE prebadajte in ne zažigajte.NE uporabite sredstev in načinov za pospeševanje odmrzovanja ali čiščenja
opreme, razen tistih, ki jih priporoča proizvajalec.
Bodite pozorni na to, da je R32 BREZ vonja.
OPOZORILO
Napravo je treba hraniti tako, da se preprečijo mehanske poškodbe, in v dobro prezračevanem prostoru, v katerem ni neprekinjeno delujočih virov vžiga (kot so odprti plameni, delujoča plinska naprava ali delujoči električni grelnik).
OPOZORILO
Prepričajte se, da so namestitev, servisiranje, vzdrževanje in popravila izvedeni v skladu z navodili Daikin in v skladu z veljavno zakonodajo (na primer predpisom o plinu) in da jih izvajajo pooblaščene osebe.
Nameščanje zunanje enote (glejte
OPOZORILO
Pritrjanje zunanje enote MORA biti izvedeno v skladu z navodili v tem priročniku. Glejte "7.2Nameščanje zunanje enote"[470].
"7.2Nameščanje zunanje enote"[470]
)
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Odpiranje in zapiranje enote (glejte
NEVARNOST: SMRTNA NEVARNOST ZARADI ELEKTRIČNEGA UDARA
Enote NE puščajte brez nadzora, če ste z nje odstranili servisni pokrov.
"7.3Odpiranje in zapiranje enote"[474]
Vodnik za monterja
)
15
3 | Specifična varnostna navodila za monterja
NEVARNOST: SMRTNA NEVARNOST ZARADI ELEKTRIČNEGA UDARA
NEVARNOST: TVEGANJE ZA OŽGANINE/OPEKLINE
Montaža cevi (glejte
"8Montaža cevi"[476]
)
OPOZORILO
Način montaže lokalnih cevi MORA biti skladen z navodili v tem priročniku. Glejte
"8Montaža cevi"[476].
V primeru zaščite pred zmrzovanjem z glikolom:
OPOZORILO
Etilenglikol je strupen.
OPOZORILO
Zaradi prisotnosti glikola lahko pride do korozije sistema. Glikol brez zaviralcev postane kisel pod vplivom kisika. Prisotnost bakra in visoke temperature dodatno pospešijo ta proces. Kisel glikol brez zaviralcev napada kovinske površine in tvori celice galvanske korozije, ki povzročajo hude poškodbe sistema. Torej je pomembno, da:
obdelavo vode pravilno izvede usposobljen strokovnjak za vodo,se uporabi glikol z zaviralci korozije, ki zavirajo nastajanje kisline zaradi oksidacije
glikola,
se ne uporablja glikol za avtomobile, ker je doba uporabnosti njegovih zaviralcev
korozije omejena in ker vsebuje silikate, ki lahko poškodujejo ali zamašijo sistem,
se v sistemih z glikolom NE uporabljajo galvanizirane cevi, ker je prisotnost glikola
lahko vzrok za obarjanje posameznih komponent iz zaviralca korozije glikola.
Električna napeljava (glejte
OPOZORILO
Način priključitve električnih kablov MORA biti skladen z navodili v:
tem priročniku. Glejte "9Električna napeljava"[490].vezalni shemi, ki je priložena enoti in jo najdete na notranji strani servisnega
pokrova. Za prevod legende sheme glejte "17.3 Vezalna shema: zunanja
enota"[4267].
NEVARNOST: SMRTNA NEVARNOST ZARADI ELEKTRIČNEGA UDARA
OPOZORILO
Za napajalne kable VEDNO uporabite večžilni kabel.
"9Električna napeljava"[490]
)
Vodnik za monterja
16
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
3 | Specifična varnostna navodila za monterja
OPOZORILO
Ožičenje MORA v celoti opraviti pooblaščen električar, izvedba pa MORA ustrezati
veljavni zakonodaji.
Izdelajte električne priključke na fiksno ožičenje.Vse komponente, ki se priskrbijo na mestu vgradnje, in vse električne napeljave
MORAJO biti skladne z veljavno zakonodajo.
OPOZORILO
Če N-faza ni priključena ali pa je napačno priključena, lahko to povzroči okvaro
opreme.
Vzpostavite primerno ozemljitev. Enote NE ozemljujte s pomočjo komunalne cevi,
prenapetostnega odvodnika ali telefonskega ozemljitvenega kabla. Nepopolna ozemljitev lahko povzroči električni udar.
Vgradite zahtevane varovalke ali odklopnike.Pritrdite električno ožičenje z vezicami za kable, tako da se kabli NE dotikajo ostrih
robov ali cevi, zlasti na strani visokega tlaka.
NE uporabljajte sestavljenih vodnikov, pletenih žičnih vodnikov, podaljševalnih
kablov ali povezav iz zvezdišča. To lahko povzroči pregrevanje, električni udar ali požar.
NE nameščajte kondenzatorja za fazni premik, saj je ta enota opremljena z
inverterjem. Kondenzator za fazni premik bo zmanjšal zmogljivost in lahko povzroči nesreče.
OPOZORILO
Vrteči se ventilator. Pred vklopom zunanje enote poskrbite, da izpustna rešetka
pokriva ventilator kot zaščita pred vrtečim se ventilatorjem. Glejte "Montaža izpustne
rešetke"[474].
POZOR
Odvečne dolžine kabla ne potiskajte oziroma NE postavljajte v enoto.
OPOZORILO
Rezervni grelnik MORA imeti posebno napajanje in MORA biti zaščiten z varnostnimi napravami v skladu z zahtevami veljavne zakonodaje.
POZOR
Da bi zagotovili popolno ozemljitev enote, vedno priključite napajanje rezervnega grelnika in ozemljitveni kabel.
OPOZORILO
Ogoljena žica. Prepričajte se, da ogoljena žica ne more priti v stik z morebitno vodo
na spodnji plošči.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Konfiguracija (glejte
POZOR
Nastavitve za funkcijo dezinfekcije MORA monter nastaviti v skladu z veljavno zakonodajo.
"11Konfiguracija"[4126]
)
Vodnik za monterja
17
3 | Specifična varnostna navodila za monterja
OPOZORILO
Pazite, da je temperatura tople vode za gospodinjstvo na pipi za toplo vodo po dezinfekcijski funkciji enaka vrednosti nastavitve [2-03].
Kadar pomeni visoka temperatura tople vode za gospodinjstvo tveganje za telesne poškodbe, je treba namestiti mešalni ventil (lokalna dobava) na izhodni priključek tople vode iz rezervoarja za toplo vodo za gospodinjstvo. Mešalni ventil mora zagotoviti, da temperatura tople vode na pipi za toplo vodo ne bo presegla maksimalne vrednosti. Maksimalna dovoljena temperatura tople vode mora biti izbrana v skladu z veljavno zakonodajo.
POZOR
Začetnega časa [5.7.3] funkcije dezinfekcije z določenim trajanjem [5.7.5] NE sme prekiniti zahteva za pripravo tople vode za gospodinjstvo.
POZOR
Urnik omogočanja pospeš. grel. [9.4.2] se uporablja za omejitev ali odobritev delovanja pospeševalnega grelnika na podlagi tedenskega programa. Nasvet: Da bi se izognili neuspešnemu izvajanju funkcije dezinfekcije, omogočite delovanje pospeševalnega grelnika (s tedenskim programom) najmanj 4 ure od trenutka zagona dezinfekcije po urniku. Če je delovanje pospeševalnega grelnika med dezinfekcijo omejeno, ta funkcija NE bo uspešna in sprožilo se bo ustrezno opozorilo AH.
Zagon (glejte
"12Zagon"[4228]
)
OPOZORILO
Način zagona MORA biti skladen z navodili v tem priročniku. Glejte
"12Zagon"[4228].
Vzdrževanje in servisiranje (glejte
POZOR
Voda, ki priteka iz ventila, je lahko zelo vroča.
OPOZORILO
Če je notranje ožičenje poškodovano, ga mora zamenjati proizvajalec, njegov servisni zastopnik ali druga kvalificirana oseba.
Odpravljanje težav (glejte
"15Odpravljanje težav"[4242]
OPOZORILO
Ko pregledujete stikalno omarico enote, VEDNO preverite, ali je enota
odklopljena iz omrežnega napajanja. Izklopite ustrezen odklopnik.
Če se je aktivirala varnostna naprava, zaustavite enoto in ugotovite vzrok za njeno
aktiviranje, preden jo ponastavite. NIKOLI ne zaobidite varnostnih naprav in ne spreminjajte njihovih vrednosti na vrednost, ki se razlikuje od tovarniške nastavitve. Če ne morete ugotoviti vzroka težave, pokličite svojega prodajalca.
"14Vzdrževanje in servisiranje"[4239]
)
)
Vodnik za monterja
18
NEVARNOST: SMRTNA NEVARNOST ZARADI ELEKTRIČNEGA UDARA
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
3 | Specifična varnostna navodila za monterja
OPOZORILO
Preprečite nevarnosti zaradi nehotene ponastavitve termičnega odklopa: napajanje te naprave NE SME biti izvedeno preko zunanjega preklopnika, denimo časovnika, in naprava ne sme biti priključena na tokokrog, ki ga vzdrževanje redno vklaplja in izklaplja.
NEVARNOST: TVEGANJE ZA OŽGANINE/OPEKLINE
OPOZORILO
Odzračevanje grelnih teles in kolektorjev. Pred odzračevanjem grelnih teles in
kolektorjev, preverite, ali se na začetnem zaslonu uporabniškega vmesnika prikaže ali .
Če se ne, lahko takoj odzračite.Če se, poskrbite za zadostno zračenje v prostoru, v katerem želite izvesti
odzračevanje. Razlog: Pri odzračevanju grelnih teles in kolektorjev lahko hladivo izteče v vodovodni krog in posledično v prostor.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Vodnik za monterja
19
4 | O škatli

4 O škatli

4.1 Pregled: O škatli

V tem poglavju

4.1 Pregled: O škatli...................................................................................................................................................................... 20
4.2 Zunanja enota......................................................................................................................................................................... 20
4.2.1 Prenašanje zunanje enote...................................................................................................................................... 20
4.2.2 Razpakiranje zunanje enote ................................................................................................................................... 21
4.2.3 Odstranjevanje opreme iz zunanje enote ............................................................................................................. 23
To poglavje opisuje, kaj morate storiti ob dobavi paketa z zunanjo enoto na mesto montaže.
Vedno imejte v mislih naslednje:
Ob dobavi je treba enoto NUJNO pregledati glede poškodb. Vsako poškodbo
MORATE takoj sporočiti prevoznikovemu agentu.
Enoto postavite še zapakirano čim bližje mestu montaže, da bi preprečili
morebitne poškodbe med premikanjem.
Vnaprej pripravite pot, po kateri nameravate vnesti enoto v prostor.

4.2 Zunanja enota

4.2.1 Prenašanje zunanje enote

Viličar ali ročni viličar
Dokler je enota še vedno na svoji paleti, za ravnanje z enoto uporabite viličar ali ročni viličar.
POZOR
Da se izognete telesnim poškodbam, se NE dotikajte dovoda zraka ali aluminijastih reber na enoti.
Vodnik za monterja
20
Ročno
Po razpakiranju prenašajte enoto s pomočjo zank, ki so dobavljene kot dodatna oprema.
Glejte tudi:
"Razpakiranje zunanje enote"[421]
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
"Odstranjevanje opreme iz zunanje enote"[423]
a1
a2
a1
a2
±150
kg
1 2
"Montaža zunanje enote"[471]
4 | O škatli

4.2.2 Razpakiranje zunanje enote

a1, a2 Zanke
OPOMBA
Razpakiranje – zgornja embalaža. Ko odstranite zgornjo embalažo, držite škatlo z
izpustno rešetko, da preprečite njen padec.
1 Odstranite plastično folijo in vrhnjo embalažo.
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Vodnik za monterja
21
4 | O škatli
2 Odstranite zunanje dodatke. Glejte "Odstranjevanje opreme iz zunanje
enote" [4 23]. (Tudi v notranjosti enote je en dodatek, ki ga je treba
odstraniti po odpiranju enote.)
3 Odstranite vrhnjo in vogalno kartonsko embalažo.
4 Odstranite plastično folijo.
Vodnik za monterja
22
5 Odstranite transportne vijake in podložke.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
M6

4.2.3 Odstranjevanje opreme iz zunanje enote

a
g
d
b c
e
f
ENERG
IJAY
IAIE
ENERG
IJAY
IAIE
h
i
j
1 Odstranite dodatno opremo z zgornje in sprednje plošče enote.
4 | O škatli
a Zanke za prenašanje enote b Splošni napotki za varnost
c Priročnik za uporabo d Priročnik za montažo e Dodatek za opcijsko opremo
f Energijska oznaka g Uporabniški vmesnik (sprednja plošča, zadnja plošča, vijaka in stenska vložka) h Izpustna rešetka
i Vijaki za izpustno rešetko
2 Ko odprete enoto (glejte "Odpiranje zunanje enote" [4 75]), odstranite
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
dodatek iz notranjosti enote.
Vodnik za monterja
23
4 | O škatli
j Zaporni ventil (z vgrajenim filtrom)
Vodnik za monterja
24
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
5 | O enotah in opcijskih dodatkih

5 O enotah in opcijskih dodatkih

V tem poglavju

5.1 Oznaka .................................................................................................................................................................................... 25
5.1.1 Nazivna ploščica: zunanja enota ............................................................................................................................ 25
5.2 Kombiniranje enot in možnosti .............................................................................................................................................. 26
5.2.1 Možni opcijski dodatki za zunanjo enoto .............................................................................................................. 26
5.2.2 Možne kombinacije zunanje enote in rezervoarja za toplo vodo za gospodinjstvo ............................................. 29

5.1 Oznaka

OPOMBA
Če sočasno nameščate ali servisirate več enot, NE smete zamenjati servisnih plošč med različnimi modeli.

5.1.1 Nazivna ploščica: zunanja enota

Mesto
Oznaka modela
Primer: EBLA16DA3V3
Koda Razlaga
E Toplotna črpalka zunanje enote monoblok
B B=reverzibilna enota (ogrevanje+hlajenje)
D=samo ogrevanje
L Nizka temperatura vode – območje okolja 2 (glejte območje
delovanja)
A Hladivo R32
16 Razred moči
DA Serija modela
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
3 3=model z vgrajenim rezervnim grelnikom
[—]=model brez vgrajenega rezervnega grelnika
V3 Napajanje:
V3=1N~, 230VAC, 50Hz W1=3N~, 400VAC, 50Hz
Vodnik za monterja
25
5 | O enotah in opcijskih dodatkih

5.2 Kombiniranje enot in možnosti

5.2.1 Možni opcijski dodatki za zunanjo enoto

Žični krmilniki za več območij
Priključite lahko naslednje žične krmilnike za več območij:
Osnovna enota z več območji 230V (EKWUFHTA1V3)Digitalni termostat 230V (EKWCTRDI1V3)Analogni termostat 230V (EKWCTRAN1V3)Aktuator 230V (EKWCVATR1V3)
Za navodila za montažo glejte priročnik za montažo krmilnika in dodatek za opcijsko opremo.
Sobni termostat (EKRTWA, EKRTR1)
INFORMACIJE
Nekatere možnosti morda v vaši državi niso na voljo.
Na zunanjo enoto lahko priključite opcijski sobni termostat. Termostat je lahko žični (EKRTWA) ali brezžični (EKRTR1).
Za navodila za montažo glejte priročnik za montažo sobnega termostata in dodatek za opcijsko opremo.
Oddaljeno tipalo za brezžični termostat (EKRTETS)
Oddaljeno tipalo notranje temperature (EKRTETS) lahko uporabljate samo v kombinaciji z brezžičnim termostatom (EKRTR1).
Za navodila za montažo glejte priročnik za montažo sobnega termostata in dodatek za opcijsko opremo.
Tiskano vezje za digitalne V/I (EKRP1HBAA)
Tiskano vezje za digitalne V/I je potrebno za zagotavljanje naslednjih signalov:
Izhod alarmaIzhod za vklop/izklop ogrevanja/hlajenja prostoraPreklop na zunanji vir toplote
Za navodila za montažo glejte priročnik za montažo tiskanega vezja za digitalne V/I in dodatek za opcijsko opremo.
Tiskano vezje za ukaze (EKRP1AHTA)
Da bi omogočili nadzor varčne energijske porabe z digitalnimi vhodi, morate namestiti tiskano vezje za ukaze.
Vodnik za monterja
26
Za navodila za montažo glejte priročnik za montažo tiskanega vezja za ukaze in dodatek za opcijsko opremo.
Oddaljeno notranje tipalo (KRCS01-1)
Privzeto se bo notranje tipalo dodeljenega vmesnika Human Comfort Interface (BRC1HHDA, ki se uporablja kot sobni termostat) uporabljalo kot tipalo temperature prostora.
Opcijsko je mogoče namestiti oddaljeno notranje tipalo za merjenje temperature prostora na drugem mestu.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
5 | O enotah in opcijskih dodatkih
Za navodila za montažo glejte priročnik za montažo oddaljenega notranjega tipala in dodatek za opcijsko opremo.
INFORMACIJE
Oddaljeno notranje tipalo se lahko uporablja samo, če je uporabniški vmesnik
konfiguriran za funkcije sobnega termostata.
Priključite lahko samo bodisi oddaljeno notranje tipalo bodisi oddaljeno zunanje
tipalo.
Oddaljeno zunanje tipalo (EKRSCA1)
Za merjenje zunanje temperature se privzeto uporablja tipalo v notranji enoti. Opcijsko je mogoče namestiti oddaljeno zunanje tipalo za merjenje zunanje
temperature na drugem mestu (npr. stran od neposrednih sončnih žarkov), da bi izboljšali obnašanje sistema.
Za navodila za montažo glejte priročnik za montažo oddaljenega zunanjega tipala in dodatek za opcijsko opremo.
INFORMACIJE
Priključite lahko samo bodisi oddaljeno notranje tipalo bodisi oddaljeno zunanje tipalo.
Kabel PC (EKPCCAB4)
Računalniški kabel omogoča povezavo tiskanim vezjem hidravlike (A1P) zunanje enote in računalnikom. Omogoča posodabljanje programske opreme hidravlike in EEPROM-a.
Za navodila za montažo glejte:
Priročnik za namestitev računalniškega kabla"Priključitev računalniškega kabla v stikalno omarico"[4129]
Konvektor toplotne črpalke (FWXV, FWXT, FWXM)
Za ogrevanje/hlajenje prostora je mogoče uporabiti naslednje konvektorje toplotne črpalke:
FWXV: talni modelFWXT: stenski modelFWXM: skriti model
Za navodila za montažo glejte:
Priročnik za montažo konvektorjev toplotne črpalkePriročnik za montažo opcij konvektorjev toplotne črpalkeDodatek za opcijsko opremo
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Zunanji komplet rezervnega grelnika (EKLBUHCB6W1) + komplet obvodnega ventila (EKMBHBP1)
Pri modelih brez vgrajenega rezervnega grelnika lahko namestite komplet zunanjega rezervnega grelnika (EKLBUHCB6W1).
Za navodila za montažo glejte:
Priročnik za montažo kompleta zunanjega rezervnega grelnika"Priključitev kompleta rezervnega grelnika" [4 105] (ta tema delno nadomesti
priročnik za montažo rezervnega grelnika)
Vodnik za monterja
27
5 | O enotah in opcijskih dodatkih
Če montirate komplet zunanjega rezervnega grelnika, morate v določenih okoliščinah montirati tudi komplet obvodnih ventilov (EKMBHBP1). Glejte:
"Potreba po uporabi kompleta obvodnih ventilov"[4108]"Priključevanje kompleta obvodnih ventilov" [4109] (ta tema delno nadomesti
list z navodili, ki je priložen kompletu obvodnih ventilov)
Kartica WLAN (BRP069A78)
Za upravljanje sistema z aplikacijo za pametni telefon lahko vgradite kartico za brezžično omrežje LAN.
Za navodila za montažo glejte priročnik za montažo kartice za WLAN.
Univerzalni centralizirani krmilnik (EKCC8-W)
Krmilnik za kaskadno upravljanje.
Komplet za dve območji (BZKA7V3)
Vgradite lahko izbirni komplet za dve območji. Za navodila za montažo glejte priročnik za montažo kompleta za dve območji.
Priključni komplet za rezervoar drugega proizvajalca (EKHY3PART)
Potrebno pri povezovanju rezervoarja drugega proizvajalca v sistem. Vsebuje termistor in 3-potni ventil. Za navodila za montažo glejte priročnik za montažo priključnega kompleta.
Priključni komplet za rezervoar drugega proizvajalca z vgrajenim termostatom (EKHY3PART2)
Komplet omogoča priključitev rezervoarja drugega proizvajalca z vgrajenim termostatom na sistem. Komplet pretvarja zahtevo termostata z rezervoarja v zahtevo po sanitarni topli vodi za zunanjo enoto.
Rezervoar za sanitarno toplo vodo
Za pripravo sanitarne tople vode je na zunanjo enoto mogoče priključiti dodaten rezervoar za sanitarno toplo vodo.
Na voljo so naslednji rezervoarji za sanitarno toplo vodo:
Rezervoar Opomba
Rezervoar iz nerjavnega jekla
Vključuje pospeševalni grelnik
(standardno):
EKHWS150D3V3EKHWS180D3V3EKHWS200D3V3
Vodnik za monterja
28
EKHWS250D3V3EKHWS300D3V3
Rezervoar iz nerjavnega jekla (+ komponente):
EKHWSU150D3V3EKHWSU180D3V3EKHWSU200D3V3EKHWSU250D3V3EKHWSU300D3V3
Vključuje:
Pospeševalni grelnikKomponente za zagotavljanje
skladnosti s predpisi Združenega kraljestva G3 za gradnjo.
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
5 | O enotah in opcijskih dodatkih
Rezervoar Opomba
Rezervoar iz polipropilena:
EKHWP300BEKHWP500B
Rezervoar z izpraznitvenim solarnim sistemom.
Za te rezervoarje je treba montirati opcijski pospeševalni grelnik (EKBH3S).
Rezervoar iz polipropilena:
EKHWP300PBEKHWP500PB
Rezervoar s solarnim sistemom pod tlakom.
Za te rezervoarje je treba montirati opcijski pospeševalni grelnik (EKBH3S).
Za navodila za montažo glejte priročnik za montažo rezervoarja za sanitarno toplo vodo in dodatek za opcijsko opremo.
Human Comfort Interface (BRC1HHDA), ki se uporablja kot sobni termostat
Vmesnik Human Comfort Interface (HCI), ki se uporablja kot sobni termostat, se
lahko uporablja samo v kombinaciji z uporabniškim vmesnikom, priključenim na zunanjo enoto.
Vmesnik Human Comfort Interface (HCI), ki se uporablja kot sobni termostat, je
treba namestiti v prostoru, ki ga želite nadzorovati.
Za navodila za montažo glejte priročnik za montažo in uporabo vmesnika Human Comfort Interface (HCI) kot sobnega termostata in dodatek za opcijsko opremo.
Stikalo pretoka (EKFLSW1)
Če vodi dodate glikol, morate namestiti tudi stikalo pretoka (in nastaviti [E-0D]=1). Za navodila za montažo glejte priročnik za montažo stikala pretoka.
Komplet relejev za pametno električno omrežje (EKRELSG)
V primeru kontaktov za visokonapetostno pametno električno omrežje je potrebna namestitev opcijskega kompleta relejev za pametno električno omrežje (EKRELSG).
Za navodila za montažo glejte "Priključitev pametnega električnega
omrežja"[4121].

5.2.2 Možne kombinacije zunanje enote in rezervoarja za toplo vodo za gospodinjstvo

Tabela kombinacij
Zunanja enota Rezervoar za sanitarno toplo vodo
EKHWS*D* EKHWSU*D* EKHWP* Rezervoar
proizvajalca
EBLA09~16 O O O O
EDLA09~16 O O O O
(a)
Če uporabljate rezervoar drugega proizvajalca, poskrbite, da bo skladen z minimalnimi zahtevami (glejte "Zahteve za rezervoar drugega proizvajalca"[429]).
drugega
(a)
(a)
EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620241-1 – 2020.06
Zahteve za rezervoar drugega proizvajalca
Če se uporablja rezervoar drugega proizvajalca, mora rezervoar izpolnjevati naslednje zahteve:
Tuljava izmenjevalnika toplote rezervoarja je ≥1,05m² in ≤3,7m².Termistor rezervoarja mora biti nad tuljavo izmenjevalnika toplote.
Vodnik za monterja
29
5 | O enotah in opcijskih dodatkih
aba
b
Pospeševalni grelnik mora biti nad tuljavo izmenjevalnika toplote.
Lahko vstavite termistor. NE MORETE vstaviti termistorja.
Za podrobnejša navodila za montažo glejte priročnik za montažo povezovalnega kompleta in dodatek za opcijsko opremo.
OPOMBA
Učinkovitost. Podatkov o učinkovitosti za rezervoarje drugih proizvajalcev NI mogoče
predložiti, zato učinkovitosti delovanja NI mogoče zagotoviti.
Če imate rezervoar, v katerem…
Uporabite EKHY3PART. Uporabite EKHY3PART2.
a Zunanja enota b Rezervoar
Vodnik za monterja
30
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06