Daikin BRC54A Operation manuals

Operation manual
Package
Components
Display (LCD)
Signal receiver
Before operation
Insert batteries
The batteries will last for about 1 year.
1 Remove the back cover. 2 Insert both batteries at once. 3 Put the cover back.
1
2
3
BRC54A
User interface BRC54A for heating only
Operation manual
User interface
English
BRC480A54
AAA.LR03
Batteries
About the user interface
Direct sunlight. Do NOT expose the user interface to direct sunlight.
Dust. Dust on the signal transmitter or receiver will reduce sensitivity. Wipe
off dust with a soft cloth.
Fluorescent lights. Signal communication might be disabled if uorescent lamps are in the room. In that case, contact your installer.
Other appliances. If the user interface signals operate other appliances, move the other appliances, or contact your installer.
Curtains. Make sure that the signal between the unit and the user interface is NOT blocked by curtains or other objects.
NOTICE
Do NOT drop the user interface.Do NOT let the user interface get wet.
1 2 3
Heating operation button
Powerful operation button
Temperature adjustment button
Comfort operation button
ON/OFF timer setting button
OFF button
Fan only button
Airow rate setting
Econo operation button
Vertical/horizontal swing setting
To operate the user interface
Aim the signal transmitter at the signal receiver on the indoor unit (maximum distance for communication is 7 m). When the indoor unit receives a signal from the user interface, you will hear a sound:
Sound Description
Beep-beep Operation starts. Beep Setting changes. Long beep Operation stops.
AAA.LR03
Fix the user interface to the wall
1 Choose a place where the signals reach
the unit. 2 Attach the holder with screws (delivered
with the unit) to the wall or a similar location.
3 Hang the user interface on the user interface holder (delivered with the unit).
User interface
Start/stop operation
1 Start operation by pressing one of the following buttons.
Mode Press
Heating operation
Fan only operation
Result: The operation lamp light up.
2 Press to stop operation. Result: The operation lamp goes off.
Symbol on the display
Holder
Screw
Temperature setting
1 Press or on the button one or more times to set the temperature
between 10~30°C. You CANNOT adjust the temperature in fan only operation mode.
: Shows the set temperature.
Airow rate setting
You can choose from following:
5 airow rate levels, from " " to " " Automatic operation
Indoor unit quiet operation. When the airow is set to " ", the noise from the unit will be reduced.
INFORMATION
If the unit reach the temperature setpoint in heating mode,
fan will stop operating.
1 Press to change the airow setting as follows:
To adjust vertical airow direction
1 Press . appears on the LCD. The aps (horizontal blades) will
begin to swing.
To use fixed position, press when the flaps reach the desired position. disappears from the LCD. The aps will stop moving.
To adjust horizontal airow direction
1 Press . appears on the LCD. The louvers (vertical blades
will begin to swing.
To use fixed position, press when the louvers reach the desired position. disappears from the LCD. The louvers will stop moving.
3-D airow direction
1 Press and . + appears on the LCD. The aps
(horizontal blades) and louvers (vertical blades) will begin to swing.
To use xed position, press and when the aps and the louvers reach the desired position. and disappears from the LCD. The aps and the louvers will stop moving.
INFORMATION
When the unit is installed in a corner of a room, the direction of the louvers should be facing away from the wall. Efciency will drop if a wall blocks the air.
To start/stop Comfort airow operation
1 Press to start. The ap position will change, is displayed on the
LCD, the airow rate is set to automatic, position of the ap is down.
Note: Comfort airow operation is NOT available in fan only mode.
1 To stop the operation press . Result: The ap will return to the position from before the Comfort airow
mode; disappears from the LCD.
INFORMATION
Powerful and Comfort airow operation CANNOT be used at the same time. The last selected function takes priority. If the vertical or horizontal automatic swing is selected, Comfort airow operation will be cancelled.
To start/stop Powerful operation
1 Press to start. is displayed on the LCD. Powerful operation
runs for 20 minutes; after that, operation returns to the previously set mode.
1 Press to stop the operation. disappears from the LCD. Note: Powerful operation can only be set when the unit is running. If you
press ; disappears from the LCD.
INFORMATION
Powerful operation CANNOT be used together with Econo and Comfort airow operation. The last selected function takes priority. Powerful operation will NOT increase the capacity of the unit if it already operates at maximum capacity.
To start/stop Econo operation
1 Press to start. is displayed on the LCD.
1 Press to stop the operation. disappears from the LCD.
INFORMATION
Powerful and Econo operation CANNOT be used at the same
time. The last selected function takes priority.
Econo operation reduces power consumption of the outdoor
unit by limiting the rotation speed of the compressor. If power consumption is already low, Econo operation will NOT further reduce power consumption.
Start/stop OFF timer operation
1 Press . is displayed on the LCD and the timer lamp lights up. 2 Press again to change the time setting (between 1 to 12 hours)
Example: If is set when the unit is operating, operation will stop
after 5 hours.
1 Press to cancel the setting. and the time setting disappear from the LCD and the timer lamp goes off.
Start/stop ON timer operation
1 Press . is displayed on the LCD and the timer lamp lights up. 2 Press again to change the time setting (between 1 to 12 hours)
Example: If is set when the unit is NOT operating, operation
will start in 2 hours.
1 Press to cancel the setting. and the time setting disappear from the LCD and the timer lamp goes off.
Combine OFF and ON timer operation
You can set both OFF timer and ON timer at once.
Example:
If set when the unit is operating, Operation stops in 1 hour and then starts 7 hours later.
If set when the unit is NOT operating. Operation start in 2 hours and then stops 3 hours later.
4
5 6 7
4P551307-1 2018.09
Loading...