SAFETY CHECK AFTER SERVING
Examine the area surrounding the repaired location for damage or deterioration. Observe that screw, parts and wires
have been returned to original positions. Afterwards, perform the following tests and conform the specified values in order
to verify compliance whit safety standards.
1. Insulation resistance test
Confirm the specified insulation resistance between power cord plug prong and externally exposed parts of the set
(RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks, etc.)
isgreater than values given in table 1 below.
2. Dielectric strengthen test
Confirm specified dielectric strengthen between power cord
plug prongs and exposed accessible parts of the set
(RF terminals, antenna terminals, video and audio input output
terminals, microphone jack, ear phone jacks, etc.)
is greater than values given table 1.
3. Clearance distance
When replacing primary circuit component, confirm specified clearance distance (d), (d’) between soldered terminals,
and between terminals and surrounding metallic parts. See table below.
Rating for selected areas
AC Line VoltageRegion
100VJapan
110 to 130V
* 110 to 130V
200 to 240V
* : Class model only
USA & Canada
Latin America
Europe
Australia
Insulation
Resistance
>1MΩ
/500V DC
-900V AC 1min.
>10MΩ
/500V DC4kV AC 1min.
Dielectric
Strength
1
kV
AC 1min.
Clearance
Distance(d),(d’)
>
3
>
3.2
>
6(d)
>
8(d’)
(a :Power cord)
NOTE
This table is unofficial and for reference only. Be sure to confirm the precise values for your
particular country and locality
2
SAFETY&PRECAUTIONS
4. Leakage current test
Confirm specified or lower leakage current between B(earth
ground, power cord plug prongs) and externally exposed accessible parts (RF terminals, antenna terminals, video and audio input
output terminals, microphone jacks, earphone jacks, etc.)
Measuring method:(Power ON) Insert load Z between B(earth
ground, power cord plug prongs) and exposed accessible parts.
Use on AC voltmeter to measure across both terminals of load Z.
See figure2 and following table.
Leakage current ratings for selected are as
AC Line VoltageRegionLoad ZLeakage Current(i) Clearance Distance(d),(d’)
100VJapan
1
KΩ
50
1
2
15kmF
KΩ
KΩ
KΩ
110 to 130VUSA &Canada
110 to 130V
200 to 240V
Europe
Australia
NOTE
This table is unofficial and for reference only. Be sure to confirm the precise values
for your particular country and locality.
i <1mA
i <
0.5mArms
i <
0.7mApeak
i <2mA
i <
0.7mA peak
i <1mA
rms
dc
dc
Exposed accessible parts
Exposed accessible parts
Antenna earth terminals
Other terminals
3
EXTERNAL VIEWS
1. FRONT VIEWS FUNCTION
DV-K813S FRONT VIEW
DV-K823S FRONT VIEW
DV-K833S FRONT VIEW
DV-K843S FRONT VIEW
4
DV-K863S FRONT VIEW
DV-K873S FRONT VIEW
+
-
EXTERNAL VIEW
DV-K893S FRONT VIEW
LR
DV-K9A3S FRONT VIEW
POWER REWIND / REVIEW
STOP / EJECTFAST FORWARD / CUE
RECORDPLAY BACK
FRONT VIDEO/AUDIO INPUT JACKCHANNEL UP / DOWN
5
EXTERNAL VIEWS
2. REAR VIEWS FUNCTION
MONO 2 SCART TYPE REAR VIEW
HI-FI 2 SCART TYPE REAR VIEW
6
ELECTRICAL ADJUSTMENT
1. PLAYBACK PHASE
ITEMMODE
6.5H
ADJUSTMENT
PCB : MAIN - TOP VIEW
PLAY[REC] BUTTON
TMI
BLOC
P50
ADJUSTMENT
POINT
CHECK POINT
PIN 4 & PIN 5
OF P504
TEST
EQUIPMENT
OSCILLOSCOPEDP-2NO SIGNAL
TEST
TAPE
ADJUSTMENT PARTSMEASURING POINT
OSCILLOSCOPE
PREAMP
TO PATH JIG
CH1 CH2
INPUT
SIGNAL
PATH JIG
ADJUSTMENT PROCEDURE
1. Play back the test tape. (DP-2)
2. Set the oscilloscope to the CHOP mode. Connect CH1 to the SW PULSE (PIN 4 of P504)
3. Connect CH2 to the ENVE signal (PIN5 of P504)
4. Insert PATH JIG and press "REC" button on the remote control.
5. Check the position of the V-sync from the rising edge of the SW pulse.
(Standard : 6.5H ± 0.5H)
7
SPECIFICATIONS
GENERAL
Power Requirement
Power Consumption
Temperature
Operating position
Dimensions (W x H x D)
Weight
Format
Tape Width
Tape Speed
Maximum Recording Time with full-size cassette
VIDEO
Signal system
Recording system
Input
Output
Signal-to-Noise ratio
Horizontal resolution
AUDIO
Recording system
Input
Output
Frequency Range
Signal to Noise Ratio
Audio Distortion
TUNER
Tuning system
RF Output
TIMER
Memory programmable
Back up time
Clock exactness
ACCESSORIES
Provided AccessoriesRemote control unit, RF Cable, Battery
AC 230V, 50Hz
Max. 17W (in REC mode)
5×C ~ 35×C (Operating)
-20×C ~ 60×C
Horizontal only
360 x 90 x 288 (mm)
Approx. 3.85 Kg
VHS standard
12.65mm
(SP) : 23.39mm/sec
(LP) : 11.70mm/sec
(SP) :240min, with E-240 video cassette
(LP) :480min, with E-240 video cassette
PAL colour and CCIR monochrome signals, 625 lines/50 fields
Rotary two-head helical scan with a slant double-azimuth combination video
head
1.0Vp-p, 75ohms, unbalanced
1.0Vp-p, 75ohms, unbalanced
45dB (Rhode & Schwarz noise meter) with NETTETE IMAGE control at center position
240 lines with NETTETE IMAGE control at center position
Longitudinal track
-8dBm, (CENELEC standard),more than 47 k-ohms, unbalanced
-6dBm, (CENELEC standard), less than 1k-ohms, unbalanced(100k-ohms,
load)
100Hz to 8,000Hz
More than 38dB