Daewoo DSB-F0983ELH-V user guide manual

DSB-F0983ELH-V DSB-F1283ELH-V DSB-F1883ELH-V DSB-F2483ELH-V
Contents
safety instructions
Preparation before use
Preset
Safety Precautions
Identification of parts
Indoor unit
Outdoor unit
Display introduction
Maintenance
Protection
Troubleshooting
Installation instructions
Installation diagram
1
2
2
2
3
4
4
4
5
6
7
8
9
9
Select the installation locations
Indoor unit installation
Wiring diagram
Outdoor unit installation
Air purging
Remote controller operating instructions.See" remote controller instructions".
10
11
14
15
15
Safety instructions
To guarantee the unit work normally, please read the manual carefully before installation,
and try to install strictly according to this manual.
Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner.
Properly ground the air conditioner into the earth.
Check the connecting cables and pipes carefully, make sure they are correct and firm
before connecting the power of the air conditioner.
There must be an air-break switch.
After installing, the consumer must operate the air conditioner correctly according to this manual,keep a suitable storage for maintenance and moving of the air conditioner in the future.
Fuse of indoor unit: T 3.15A 250V.
For models f T 15A 250V or T 20A 250V . 7k~12k use of outdoor unit: For models f T 20A 250V . 14k~18K use of outdoor unit: For models f T 30A 250V . 21K~30k use of outdoor unit:
A residual current device(RCD)with the rating of above 10mA shall be incorporated
in the fixed wiring according to the national rule Warning: Risk of electric shock can cause injury or death: Disconnect all remote electric power supplies before servicing . The maximum length of the connecting pipe between the indoor unit and outdoor unit should be less than 5 meters. It will affect the efficiency of the air conditioner if the distance longer than that length. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
The batteries in remote controller must be recycled or disposed of properly.
Disposal of Scrap Batteries --- Please discard the batteries as sorted municipal
waste at the accessible collection point.
If the appliance is fixed wiring, the appliance must be fitted with means for
disconnection from the supply mains having a contact separation in all poles that
provide full disconnection under overvoltage category III conditions, and these
means must be incorporated in the fixed wiring in accordance with the wiring rules. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
The appliance shall be installed in accordance with national wiring regulations.
The air conditioner must be installed by professional or qualified persons. The appliance shall not be installed in the laundry.
1
Preparation before use
Note
When charging refrigerant into the system, make sure to charge in liquid state,if the refrigerant of the appliance is R410A.Otherwise, chemical composition of refrigerant (R410A) inside the system may change and thus affect performance of
the air conditioner. According to the character of pressure of the tube is very high, so be sure to be careful when you install and repair the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
The air conditioner must be installed by a professional engineer.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
Preset
Before using the air conditioner, be sure to check and preset the following.
Remote Control presetting
Each time after the remote control is replaced with new batteries or is energized, auto presetting heat pump.If the air conditioner you purchased is a Cooling Only one, heat pump remote controller can also be used.
Back-light function (optional) of Remote Control
refrigerant (R410A,the value of GWP is 1975), the
remote control
Hold down any button on remote control to activate the back light. It automatically shuts off 10 seconds later.
Note: Back-light is an optional function.
Auto Restart Presetting
The air conditio ner has an Auto-Restart function.
Safeguarding the environment
This appliance i s made of recyclable or re-usable m aterial. Scrapping must be carr ied out in compliance wit h local waste disposal regulati ons. Before scrapping it, make su re to cut off the mains cord so that the appliance cannot be re-used. For more detaile d information on handling and rec ycling this product, contact yo ur local authorities who deal with the se parate collection of rubbish or t he shop where you bought the applia nce.
SCRAPPING OF APPLIAN CE
This appliance i s marked according to the Europea n Directive 2002/96/EC, Waste Elect rical and Electronic Equ ipment (WEEE).
This marking ind icates that this product should n ot be disposed with other house hold wastes throughout the EU. To preve nt possible harm to t he environment or human health fr om uncontrolled w aste disposal,recycle it resp onsibly to promote the sustainabl e reuse of material resources. To retur n your used device, ple ase use the return and collection s ystems or contact the retailer where the product was purcha sed. They can take this product for environmental safe recycl ing.
2
Safety precautions
Symbols in this Use and Care Manual are interpreted as shown below.
Be sure not to do.
Pay attention to such a situation.
Use correct power supply in accordance with the rating plate requirement. Otherwise, serious faults or hazard may occur or a fire maybe break out.
Keep the power supply circuit breaker or plug from dirt. Connect the power supply cord to it firmly and correctly, lest an electric shock or a fire break out due to insufficient contact.
ON
OFF
Grounding is essential.
Warning: Incorrect handling could cause a serious hazard, such as death, serious injury, etc.
ON
OFF
Do not use the power supply circuit breaker or pull off the plug to turn it off during operation. This may cause a fire due to spark, etc.
Do not knit, pull or press the power supply cord, lest the power supply cord be broken. An electric shock or fire is probably caused by a broken power supply cord.
ON
OFFON OFF
ON/OFF
MODE FAN
SLEEP
SWING
SUPER
SMART
IFEEL DIMMER
TIMER ON TI MER OFF CLOCK
Turn off the appliance by remote control firstly before cutting off power supply if malfunction occurs.
Do not touch the operation buttons when your hands are wet.
Never insert a stick or similar obstacle to the unit. Since the fan rotates at high speed, this may cause an injury.
Do not repair the appliance by yourself. If this is done incorrectly, it may cause an electric shock, etc.
Do not put any objects on the outdoor unit.
It is harmful to your health if the cool air reaches you for a long time. It is advisable to let the air flow be deflected to all the room.
Prevent the air flow from reaching the gas burners and stove.
It is the user's responsibility to make the appliance be grounded according to local codes or ordinances by a licenced technician.
3
Identification of parts
Indoor unit
Front Panel
Air Intake
Display Panel
Emergency Panel
Air Outlet
Vertical Adjustment
Louver
ON
ON
O
O
F
F F
F
O
N
/ O
F
F
MO
D E
FA
SW
N I N
G
SL
SMA
E
E
P
RT
SUP
I
T
F
ER
I
E
M
E
E
L
R O
N
DI T I
M
M
MER
ER O
F F
CL
O C
K
Outdoor unit
Horizontal Adjustment
Louver
Air Filter
Remote Controller
Air Intake
Pipes and Power
Connection Cord
Drain Hose
Note: Condensate water drains at COOLING or DRY operation.
Air Outlet
The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have selected.
4
Loading...
+ 13 hidden pages