All tolerances: ±¹/₁₆” (±1.6 mm) unless otherwise stated.
RMND24 Cutout Dimensions
Heritage 24”, 30” Wide
Microwave In A Drawer
A. 6” B. Power outlet location C. Anti-tip block D. 5” E. 3 ” F. 4” G. 22 ” opening H. 14 ¹³/₁₆” to bottom of anti-tip block I. Allow ” minimum overlap J. 23 ” minimum depth K. Allow ³/₁₆” minimum overlap L. 36” nominal countertop height M. Allow ” minimum overlap N. Floor must support 100 lbs minimum O. 24” cabinet minimum P. 15 ⁹/₁₆” opening
NOTE: Open-top cabinet shown
PLANNING
GUIDE
WARNING
• Observe all local ordinances during planning and installation. Contact your local building department for details.
• This unit must be installed according to its installation instructions.
NOTE: Spacing between
appliances and doors/drawers
is minimum required to allow
for ventilation and to prevent
scraping. More space may be
needed for appearance.
A. 21 ” B. 4 ¹¹/₁₆” C. 1 ” D. 21 ” E. 23 ” F. 15 ” G. 14 ¹⁹/₃₂” H. 1 ⁹/₆₄” door thickness I. 15” auto drawer
opening
J. 4"
Utility Location Anti-tip Block Location
Electrical outlet
location
Electrical Specifications
Dedicated Circuit
Required
120 Vac, 60 Hz, 15 Amp. 3-wire
grounded, electri-
cal outlet
(6")
Total Connected
Load
13 Amp. @ 120 Vac,
60 Hz.
Anti-tip
block
5"
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
Anti-tip
block
(6")
RNMDxx
Doc #: PGH-RNMD.01 Revised 18 Sept 2018 Page 2 of 2
All tolerances: ±¹/₁₆” (±1.6 mm) unless otherwise stated.
RMND30 Cutout Dimensions
Heritage 24”, 30” Wide
Microwave In A Drawer
A. 6” B. Power outlet location C. Anti-tip block D. 5” E. 3 ” F. 4” G. 28 ⁷/₁₆” opening H. 14 ¹³/₁₆”to bottom of anti-tip block I. Allow ²³/₃₂” minimum overlap J. 23 ” minimum depth K. Allow ³/₁₆” minimum overlap L. 36” nominal countertop height M. Allow ” minimum overlap N. Floor must support 100 lbs minimum O. 30”cabinet minimum P. 15 ⁹/₁₆” opening
NOTE: Open-top cabinet shown
PLANNING
GUIDE
NOTE: Spacing between appliances and doors/
drawers is minimum required to allow for
ventilation and to prevent scraping. More
space may be needed for appearance.
A. 21 ” B. 4 ¹¹/₁₆” C. 1 ” D. 21 ” E. 30” F. 15 ” G. 14 ¹⁹/₃₂” H. 1 ⁹/₆₄” door thickness I. 15 ” auto drawer
opening
J. 4"
Utility Location Anti-tip Block Location
Electrical outlet
location
Electrical Specifications
Dedicated Circuit
Required
120 Vac, 60 Hz,
15 Amp. 3-wire
grounded, electri-
cal outlet
(6")
Total Connected
Load
13 Amp. @ 120 Vac,
60 Hz.