RNMDxx
Doc #: PGH-RNMD.01 Revised 18 Sept 2018 Page 1 of 2
All tolerances: ±¹/₁₆” (±1.6 mm) unless otherwise stated.
RMND24 Cutout Dimensions
Heritage 24”, 30” Wide
Microwave In A Drawer
A. 6”
B. Power outlet location
C. Anti-tip block
D. 5”
E. 3 ”
F. 4”
G. 22 ” opening
H. 14 ¹³/₁₆” to bottom of anti-tip block
I. Allow ” minimum overlap
J. 23 ” minimum depth
K. Allow ³/₁₆” minimum overlap
L. 36” nominal countertop height
M. Allow ” minimum overlap
N. Floor must support 100 lbs minimum
O. 24” cabinet minimum
P. 15 ⁹/₁₆” opening
NOTE: Open-top cabinet shown
PLANNING
GUIDE
WARNING
• Observe all local ordinances during planning
and installation. Contact your local building
department for details.
• This unit must be installed according to its
installation instructions.
NOTE: Spacing between
appliances and doors/drawers
is minimum required to allow
for ventilation and to prevent
scraping. More space may be
needed for appearance.
A. 21 ”
B. 4 ¹¹/₁₆”
C. 1 ”
D. 21 ”
E. 23 ”
F. 15 ”
G. 14 ¹⁹/₃₂”
H. 1 ⁹/₆₄” door thickness
I. 15” auto drawer
opening
J. 4"
Utility Location Anti-tip Block Location
Electrical outlet
location
Electrical Specifications
Dedicated Circuit
Required
120 Vac, 60 Hz,
15 Amp. 3-wire
grounded, electri-
cal outlet
(6")
Total Connected
Load
13 Amp. @ 120 Vac,
60 Hz.
Anti-tip
block
5"
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
RNMDxx
Doc #: PGH-RNMD.01 Revised 18 Sept 2018 Page 2 of 2
All tolerances: ±¹/₁₆” (±1.6 mm) unless otherwise stated.
RMND30 Cutout Dimensions
Heritage 24”, 30” Wide
Microwave In A Drawer
A. 6”
B. Power outlet location
C. Anti-tip block
D. 5”
E. 3 ”
F. 4”
G. 28 ⁷/₁₆” opening
H. 14 ¹³/₁₆”to bottom of anti-tip block
I. Allow ²³/₃₂” minimum overlap
J. 23 ” minimum depth
K. Allow ³/₁₆” minimum overlap
L. 36” nominal countertop height
M. Allow ” minimum overlap
N. Floor must support 100 lbs minimum
O. 30”cabinet minimum
P. 15 ⁹/₁₆” opening
NOTE: Open-top cabinet shown
PLANNING
GUIDE
NOTE: Spacing between appliances and doors/
drawers is minimum required to allow for
ventilation and to prevent scraping. More
space may be needed for appearance.
A. 21 ”
B. 4 ¹¹/₁₆”
C. 1 ”
D. 21 ”
E. 30”
F. 15 ”
G. 14 ¹⁹/₃₂”
H. 1 ⁹/₆₄” door thickness
I. 15 ” auto drawer
opening
J. 4"
Utility Location Anti-tip Block Location
Electrical outlet
location
Electrical Specifications
Dedicated Circuit
Required
120 Vac, 60 Hz,
15 Amp. 3-wire
grounded, electri-
cal outlet
(6")
Total Connected
Load
13 Amp. @ 120 Vac,
60 Hz.
Anti-tip
block
5"
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093