Dacor RNIVS2 Planning Guide

IVS1, IVS2, IVSR1, IVSR2
10 inch round
6 1/2"
6 1/2"
Renaissance
Integrated Ventilation System
WARNING
• Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.
8" (20,3 cm) round exhaust
with back draft damper
Electrical
access
holes
6” (15.2 cm)
21 1/4"
22 1/2"
(57.2 cm)
(54.0 cm)
11 1/16"
(28.1 cm)
12 1/4"
(31.1 cm)
®
8" (20,3 cm) round exhausts
33 1/4"
(84.5 cm)
34 1/2"
(87.6 cm)
IVS2/IVSR2 OVERALL DIMENSIONS
(16.5 cm)
C
L
PLANNING
with back draft damper
(16.5 cm)
C
L
Revised 07/03/14 Page 1/1
GUIDE
Electrical
access
holes
6” (15.2 cm)
11 1/16"
(28.1 cm)
12 1/4"
(31.1 cm)
C
L
C
L
IVS1/IVSR1 OVERALL DIMENSIONS
8" exhaust
C
L
C
L
8" exhaust
IVS1/IVSR1 EXHAUST DIMENSIONS - TOP VIEW
The Dacor IHL series integrated hood liner is designed for use with all Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be built into a custom hood structure to provide the required ventilation and heat resistant, easy to clean surfaces.
IMPORTANT: Local building codes may require the use of makeup air systems with ventilation systems that move air greater than the specified movement rate (CFM). The specified rate varies based on locale. Consult a qualified HVAC specialist when designing the system for the requirements in your area and to assure optimal performance.
Model No.
IVS1
IVSR1 0.2 kW (1.5 Amp.)* Remote** See REMP specications 21 lbs.
IVS2 0.4 kW (3 Amp.) Internal 1200 CFM Nom. 38 lbs.
IVSR2 0.2 kW (1.5 Amp.)* Remote** See REMP specications 29 lbs.
Does not include remote blower.
* ** Remote blower required. Use only Dacor REMP series remote blower *** At zero inches static pressure
Dedicated Circuit
Required
120 Vac, 60 Hz.,
15 Amp. Min.
grounded,
dedicated circuit
Maximum
Duct Length
Maximum 60
equivalent
straight feet
Total
Connected Load
0.2 kW (2 Amp.) Internal 600 CFM Nom. 25 lbs.
IVS2/IVSR2 EXHAUST DIMENSIONS - TOP VIEW
2" (5.1 cm)
13" (33.0 cm)
21" (53.3 cm)
8" (20.3 cm)
ATD10 DIMENSIONS - FOR USE WITH IVS2 AND IVSR2
Blower
Configuration
(SOLD SEPARATELY)
Blower Rating
Shipping Weight
Approximate
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com