• Installer: In the interest of safety and to minimize problems, read these Installation Instructions completely and care-
fully before you begin the installation process. Leave these installation instructions with the user.
Write the data plate information in the User Manual before installing the unit.
• User: Keep these Installation Instructions for future reference and for the local electrical inspector’s use.
If You Need Help...
If you have questions or installation/operation/warranty issues, contact Dacor Customer
Assurance. Have availabe the cooktop model and serial numbers, which are on the
product data label on the chassis bottom (see right).
Dacor Customer Assurance
Phone: 833-35-ELITE (833-353-5483) USA, Canada
Mon – Fri 5:00
Website: www.dacor.com/customer-care/contact-us
Appliance Data Plate
The appliance data plate is a label that:
• has the model and serial number information and electrical requirements.
• is located inside the RNIVS, above the filters on the back wall of the chassis. Remove
the filters to locate the plate.
a.m. to 5:00 p.m. Pacific Time
All specifications subject to change without notice. Dacor assumes no liability for changes to specifications.
• The Important Safety Instructions and warnings in
these instructions are not meant to cover all possible
problems and conditions that can occur. Use common
sense and caution when installing, maintaining, or operating this or any other appliance.
• Always contact Dacor Customer Assurance about issues
you cannot resolve.
Safety Alerts
When you see these alerts in the manual, read the
message carefully before continuing.
DANGER
Immediate hazards that WILL result in severe personal injury or
death.
WARNING
Hazards or unsafe practices that COULD result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that MIGHT result in minor
personal injury or property damage.
General Safety Precautions
To reduce the risk of fire, electric shock, serious injury or
death when using your appliance, follow basic safety precautions, including the following:
CAUTION
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
WARNING
To reduce risk of fire, electric shock, and personal injury:
• Installation work and electrical wiring must be done by
qualified personnel according to applicable codes and
standards, including fire-rated construction.
• Sufficient air is needed for proper combustion and exhaust of
gases out the chimney of fuel-burning equipment to prevent
backdraft. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
• Know the location of utilities before cutting/drilling into a wall or
ceiling.
• Ducted fans must always be vented to the outdoors.
WARNING
To reduce risk of fire, electric shock, and personal injury:
• Use this unit only as intended by the manufacturer. If you have
questions, contact the manufacturer.
• Before servicing/cleaning unit, turn off power at the service
panel, and lock the panel to prevent power from being turned
on. If locking the panel is not an option, securely fasten a
prominent warning device, such as a tag, to the panel.
DANGER
To avoid risk of explosion or fire, do not store/use combustible,
flammable substances (ex: gasoline) in/on/near this appliance.
Keep items that could explode (ex: aerosol cans) away from
cooking units and hoods.
WARNING
• To avoid property damage, personal injury, or death from fire
or explosion, follow the directions in this manual precisely.
• Do not install the unit if it dropped, was damaged in some
way, or malfunctions. If the product is damaged when
received, immediately contact the dealer or builder.
• The unit must be installed and grounded by a qualified installer as instructed in this manual.
• Install the unit only per the instructions and requirements
specified by the manufacturer of the cooking unit. Not doing
so can cause serious personal injury and property damage.
• The user should install/repair/replace components only as
specifically recommended in the provided manuals. A qualified technician should perform all other service. Contact the
nearest Dacor authorized service representative at (800)
793-0093, or at www.dacor.com for examination, repair, or
adjustment.
• Keep all packaging materials away from children.
• Do not use an extension cord or adapter plug.
• The installer must show the user the fuse box or circuitbreaker panel so power can be turned on/off as needed.
• Do not tamper with the controls.
• If the cooktop and hood are near a window, do not hang window coverings that could blow over the cooktop and hood.
• Always run the fan(s) whenever the cooktop is operating.
• Never leave the range or cooktop unattended when a burner
(or element) is in use. Boil-overs and greasy spills may
smoke and/or ignite.
• Do not leave children unattended near the active cooktop
and hood. Never let children sit/stand on an appliance or play
with the cooking unit or hood. Do not store items of interest to
children above/on/near the appliances.
• The minimum distance between cooking surface and hood
bottom must be at least 30” (76.2 cm).
• USE ONLY METAL DUCTWORK.
• Do not try to use this appliance during a power outage.
1
Page 4
Product Specifications
General Specifications
Dacor’s Heritage Integrated Ventilation System (RNIVS) is designed to be installed inside custom hood canopies. Correct
installation requires that the custom canopy be constructed with precision design, manufacturing, and materials.
Follow all instructions and warnings concerning the installation of the RNIVS within a combustible or non-combustible
hood canopy.
Make sure that all construction meets applicable local codes and regulations.
All Models
FeaturesDescription
FiltersBaffle style, Dishwasher safe
Dimmable LED 7.5 Watt, 60 Hz.
Lights
Total Circuit
Requirements*
Total
Connected
Load*
Fan Rating**
* Electrical specifications are provided for reference only.
Consult the product data label on the unit for exact specifications.
** Rated at zero-inches static pressure.
Compatible with Halogen or any
dimmable, 75W max bulb
Amp.) Plus the power requirements
of the in-line blower or the remote
blower
RNIVS1: 600 CFM
RNIVS2: 1200 CFM
RNIVSR1 and RNIVSR2: Depends
on the in-line blower or remote
blower specifications
Individual Models
Features
Lights22
Filters23
Fans
(not including
“R” Models)
Exhaust Vents12
RNIVS1
RNIVSR1
12
Dacor Blower Models Used in RNIVSR Series:
RNIVSR models do not have blowers. Blowers must be
purchased separately.
Duct Size
8 inchILHSF8REMP3
10 inchILHSF10REMP16
In-Line Style
Blower Model
RNIVS2
RNIVSR2
Remote Style
Blower Model
Model NumberWeight
RNIVS128 lb. (13 kg)
RNIVS244 lb. (20 kg)
RNIVSR124 lb. (11 kg)
RNIVSR235 lb. (16 kg)
Liner Kit#Description (W x H x D)
For a 30” Canopy
RNIHL30
RNIHL36
RNIHL48
(27” x 2” x 21”)
5 lb. (2.3 kg)
For a 36” Canopy
(33” x 2” x 21”)
5.5 lb. (2.5 kg)
For a 48” Canopy
(45” x 2” x 21”)
7 lb. (3.18 kg)
2
Page 5
Product Specifications
C
L
Product Dimensions
All tolerances are ±1/16” (±0.16 cm)
RNIVS1 &
RNIVSR1
3/
8”
(1.0 cm)
8 7/8”
(22.5 cm)
3/8” Rear Flange
Extension
7/
21
(54.45 cm)
Top View
20 1/4”
(54.43 cm)
16”
RNIVS1 & RNIVSR1 Dimensions
10
(27.69 cm)
23/
32”
18 1/2”
(46.92 cm)
10
(27.69 cm)
C
L
23/
32”
19 5/8”
(49.82 cm)
5 3/4”
(14.54 cm)
6 3/16”
(15.72 cm)
Top Centerline Dimensions
3
Page 6
Product Specifications
.40
Product Dimensions
All tolerances are ±1/16” (±0.16 cm)
RNIVS1 &
Rear View
Side View
3/
8”
(1.0 cm)
Channel Dimensions
channel depth
back panel
RNIVSR1
channel height
2 1/
8”
(5.04 cm)
3/
(1.0 cm)
flange
3/
3/8” Rear Flange Extension
8”
(1.0 cm)
Detail
flange
Rear Flange and Channel Dimensions
(Side View)
(1.0 cm)
8”
channel depth
channel height
2 1/
8”
(5.04 cm)
3/
flange extension length
8”
4
Page 7
C
L
Product Specifications
Product Dimensions
All tolerances are ±1/16” (±0.16 cm)
30 1/4”
(76.84 cm)
RNIVS2 &
RNIVSR2
8 7/8”
(22.5 cm)
3/
(1.0 cm)
8”
3/8” Rear Flange
Extension
Top View
31
(79.83 cm)
7/16
”
RNIVS2 & RNIVSR2 Dimensions
”
6
(15.24 cm)
C
L
18 1/2”
(46.92 cm)
6
”
(15.24 cm)
19 5/8”
(49.82 cm)
5 3/4”
(14.54 cm)
6 3/16”
(15.72 cm)
Top Centerline Dimensions
5
Page 8
Product Specifications
.40
Product Dimensions
All tolerances are ±1/16” (±0.16 cm)
Rear View
3/
8”
(1.0 cm)
channel depth
back panel
RNIVS2 &
RNIVSR2
channel height
2 1/
8”
(5.04 cm)
Side View
3/8” Rear Flange Extension
Channel Dimensions
flange
3/
8”
(1.0 cm)
Detail
3/
(1.0 cm)
8”
channel depth
channel height
2 1/
8”
(5.04 cm)
flange
3/
8”
(1.0 cm)
flange extension length
Rear Flange and Channel Dimensions
(Side View)
6
Page 9
Preparation and Setup
STAINLESS
STEEL
CLEANER
Parts List
A
RNIVS
B
Grease channel (1)
C
Baffle filter and hardware (2)
E
Dimmable LED light bulbs (2)
F
Light replacement tool (1)
G
Literature (2)
Dacor Stainless Cleaning Creme (1)
H
E
A
FeaturesRNIVS1RNIVS2
C
E
Filters23
LED Lights22
pictures vary by model
C
B
H
Necessary Tools and Hardware
Please make sure these tools and hardware are within
reach before beginning the installation.
RNIVS Installation
Phillips screwdriverDrill + bitsJigsaw
Flathead
screwdriver
Pencil or
marking tool
Wire connector capsLevel
Wire stripperJunction box
Tape measure8” Ducting
Stud finderFoil tape
Sheet metal
18 AWG Wire
or 3-prong
power cord
screws
F
G
Optional Accessories
The items below are optional accessories that can be
added to your RNIVS.
Hood Liner Kit
Dacor Liner Kit #
RNIHL30/36/48
Dual to Single Vent
Transition Kit
Dacor Transition Kit #
ATD10
10” Ducts and
ducting materials
Sheet metal
screws
DrillFoil tape
Sheet metal
screws
--
--
7
Page 10
Preparation and Setup
E
F *
(hood/canopy materials
* From cooking surface
E
determine distance)
Meeting Installation Requirements
WARNING
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information. Use only ductwork
deemed acceptable by state, municipal and local codes.
WARNING
To reduce the risk of personal injury caused by reaching
over a hot appliance, cabinet storage space located
directly above the range should be avoided.
IMPORTANT
See the diagram for minimum installed distance from
the hood to the cooktop surface. The minimum specified
distance may be higher for the particular range or
cooktop in use. Check the manufacturers specifications
for the cooktop or range.
• The hood canopy must be as wide as the cooktop surface or wider.
• Plan the installation so that all minimum dimensions
are met or exceeded.
• Dimensions given are minimum clearances, unless otherwise noted.
• All contact surfaces between the RNIVS and any cabinetry or walls must be sturdy, solid, and at right angles.
• Install the RNIVS and cooking appliance(s) so that they
can be removed if service is required.
• Local building codes may require the use of makeup air
systems with ventilation systems that move air greater
than the specified movement rate (CFM). The specified
rate varies based on locale. Consult a qualified HVAC
specialist when designing the system for the requirements in your area and to assure optimal performance.
• An RNIVS installed inside a custom hood canopy made
of combustible materials must be a minimum of 36”
(91.4 cm) above the countertop cooking surface.
• An RNIVS installed inside a custom hood canopy made
of non-combustible materials must be a minimum of 30”
(76.2 cm) above the countertop cooking surface.
• An RNIVS installed inside any custom hood canopy
using a Dacor RNIHL Series Stainless Steel Hood
Liner must be a minimum of 30” (76.2 cm) above the
countertop cooking surface.
All tolerances are +1/16”, -0” (+.16, -0 cm)
ModelsE
RNIVS1, RNIVSR130 inches (76.2 cm)
RNIVS2, RNIVSR236 inches (91.5 cm)
MaterialsF
Combustible Materials (wood)36 inches (91.5 cm)
Non-Combustible (tile, metal)30 inches (76.2 cm)
Dacor RNIHL Hood Liners30 inches (76.2 cm)
Metal Hood Linerssee mfg. specs
Cabinet Layout Dimensions
Minimum Width of E:
Upper Cabinet Cutout & Appliance Width
Minimum Height of F:
From Cooking Surface to Bottom of Hood
8
Page 11
Preparation and Setup
C
L
Meeting Electrical Codes
WARNING
Make sure electrical service to the RNIVS is installed by a licensed electrician.
It is the owner’s responsibility to confirm that all electrical
requirements are met by a qualified electrician who is
servicing this appliance.
The electrical installation, including the minimum supplywire size and grounding, must be in accordance with the
National Electric code ANSI/NFPA* (or latest revision), local
codes, and ordinances.
*A copy of this standard can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
• The ground terminal inside the RNIVS must be connected to a grounded, metallic, permanent wiring system, or to a grounding conductor installed by a licensed
electrician.
• Do not ground the appliance or appliance wiring to a
gas pipeline or to the neutral (white) power supply wire.
• Do not install a fuse in the neutral or ground circuit.
• Connect the RNIVS directly to an electrical junction box. Hard-wire the RNIVS according to local code
directly to a dedicated three-wire grounded, single
phase circuit: rated at 120 Vac 60 Hz, 15 Amp.
• See the diagram: Electrical Access Holes for wire
hole locations inside the RNIVS.
• See Wiring Diagrams at the end of this document.
HORIZONTAL
DIMENSIONS
RNIVS1 & RNIVS2
AB
A B
3 3/8”
3 15/16”
(8.57 cm)
VERTICAL DIMENSIONS
RNIVS1 & RNIVS2
C D
CD
2 3/4”
(7 cm)
EDiameter
E
1 1/2”
(3.81 cm)
(10.07 cm)
C D
E
3 3/16”
(8.16 cm)
7
/8”
(5.1 cm)
A
B
Electrical Access Holes
All tolerances are ±1/16” (±0.16 cm)
Electrical access hole dimensions are the same on all
RNIVS models.
9
Page 12
Preparation and Setup
Planning the Ductwork
WARNING
• To prevent combustion by-products, smoke or odors
from entering the home and to improve efficiency, tape
all duct joints securely.
• Range hoods may interrupt the proper flow of smoke
and combustion gases from furnaces, gas water heaters, and fireplaces. To avoid drawing lethal gases into
the home, follow the manufacturer’s recommendation
for these devices and consult NFPA and ASHRAE recommendations.
• Failure to install a remote blower or proper ductwork
may result in a backdraft and/or insufficient venting of
smoke and fumes.
• DO NOT install an additional in-line or external blower
to increase the length of the duct run. Even small differences between blower air flow rates can greatly
reduce the air draw by the hood.
CAUTION
To reduce the risk of fire and to properly exhaust air, be
sure to duct air outside the house or building. Do not vent
exhaust air into spaces within walls or ceilings or into
attics, crawl spaces or garages.
WARNING
During duct installation, make sure there are no
obstructions that keep the damper flaps on the top of the
hood from opening.
• Local building codes may require the use of makeup air
systems with ventilation systems that move air greater
than the specified movement rate (CFM). The specified
rate varies based on locale. Consult a qualified HVAC
specialist when designing the system for the requirements in your area and to assure optimal performance.
• All ductwork materials (including screws and foil tape)
must be purchased separately by the customer.
• Make sure ductwork does not interfere with floor joists
or wall studs.
• On dual exhaust models, the two 8-inch exhausts may
be merged into one 10-inch duct using Dacor transition
kit ATD10. See page 12 for details.
• Fasten all joints with sheet metal screws and seal with
certified duct tape or foil tape.
• When planning new ductwork, always look for the
shortest, most direct route to the outside.
• To prevent a backdraft, never decrease the duct size
over the run. If existing ductwork is smaller than 8
inches in diameter, remove it and replace it with 8-inch
ductwork.
Duct Length Calculation Table
The maximum straight duct length for the hood is determined by the type of duct used. See the chart below.
Duct SizeMaximum Duct Run
8-inch Round60 feet
10-inch Round50 feet
3 1/4-in x 10-in Rectangular50 feet
For each elbow and transition added, a certain length must
be subtracted from the maximum duct run to compensate
for wind resistance.
Use the chart below to determine the maximum length of
your duct run:
1. Write the total length of your duct run, then
2. Subtract all of the ductwork equivalent lengths in the
chart below.
Ductwork Equivalent Lengths
PieceSubtractPieceSubtract
8-inch
90° Elbow
8-inch
45° Elbow
3¼ in x 10 in
to Round 90°
Transition
Roof Cap*
* The equivalent lengths of roof and wall caps vary with
model and configuration.
7 feet10-inch 90° Elbow5 feet
3 feet10-inch 45° Elbow2 feet
3¼ in x 10 in to 8
25 feet
in / 10 in Round
Transition
Wall Cap with
Damper
4 feet
*
Ductwork Tips
Wherever possible, reduce the number of transitions, turns,
and sharp angles. Two staggered 45° angles are better
than one sharp 90° angle.
Keep turns as far away from the RNIVS exhaust as possible, and keep as much space between any bends as possible.
For best performance: use round duct instead of rectangular, especially when elbows are required.
If multiple elbows are used, try to keep at least 24 inches of
straight duct between each elbow.
Avoid using “S” or back-to-back adjacent elbows.
In extremely cold weather regions, use thermal breaks, i.e.,
short sections of non-metallic duct, to avoid indoor heat
loss. Locate the break as close as possible to the outside
pass-through point.
Do not use flexible metal duct. Do not use ductwork that is
smaller than what is advised in the tables.
To prevent backdrafts, a damper at the duct outlet may
also be required.
10
Page 13
Installation Instructions
Assembling the Filters
Filters are boxed separately and must be assembled during installation. All knobs and hardware are included with the
filters.
To ensure the correct orientation, make sure the top of the filter lays face-up.
The face of the filter has:
• plastic peel-away coating
• a beveled lip on the inside frame
• screw holes up on the ridge (not down in the trough)
Instructions
1. Remove the plastic coating and confirm that the inside lip is beveled. If this is true, proceed. If not, flip the frame.
2. Align the screw, lock washer, and knob with the filter.
• Make sure the knob is on the ridge, and the
• screw and lock washer are in the trough.
3. Twist and secure until tight.
4. Proceed with the Installation Instructions and install the filters after hanging the RNIVS.
Baffle-Style Filter
RNIVS Filter Kit Number Description
702579Baffle-Style Filter Kit (1 pc + hardware)
702580Baffle-Style Filter Kit (2 pc + hardware)
beveled lip
3
Filter Parts
Filter (baffle style)
1
Knob
2
Screw M8
3
Lock washer #10
4
2
1
4
11
Page 14
Installation Instructions
Installing the Hood Liner Kit #RNIHL
The Heritage Integrated Hood Liner (RNIHL) is available
separately and must be installed before the RNIVS.
The RNIHL liners are made from of durable, noncombustible stainless steel. The latest Renaissance®
design make it an excellent component for any custom
hood.
Compatibility
Liner Kit # Renaissance® RNIVS Model
RNIHL30RNIVS1RNIVSR1
RNIHL36RNIVS1RNIVSR1
RNIHL48RNIVS2RNIVSR2
See the RNIHL Installation Instructions booklet for
complete details and specifications.
If you are not using a hood liner, skip this page.
• Read and follow the complete RNIVS Installation
Instructions manual to correctly install your custom
hood ventilation system.
• Follow all electrical requirements specified in the RNIVS
Installation Instructions.
• The Renaissance® RNIHL Series Hood Liner has no
electrical parts.
• Plan the installation so that all minimum clearances are
met or exceeded.
• The RNIVS is attached using the lock washers and
bolts provided with the RNIHL liner. Quantity varies
according to the RNIHL liner model.
• The RNIHL liner is designed for vertical exhaust duct
(VED) configurations only.
Hood Canopy
RNIHL Hood Liner
RNIVS2
Installing the RNIHL Hood Liner
into the Hood Canopy
lock washers
bolts
Hardware to Attach the
RNIVS to the RNIHL Hood Liner
RNIVS2
RNIHL48
RNIVS2 Installed to the
RNIHL48 Hood Liner
12
Page 15
Installation Instructions
21" (53.3 cm)
8" (20.3 cm)
13" (33.0 cm)
10 inch round
2" (5.1 cm)
C
L
C
Attaching the Dual-to-Single
Marking the Centerlines
All tolerances are
±1/16” (±0.16 cm)
Transition Kit #ATD10
Two 8” ducts can be transitioned into one 10” duct.
• Attach the kit # ATD10 before installing the RNIVS.
• The kit fits over the top ventilation exits.
Preparing the ATD10
Bend the flanges outward at right angles around the base.
This procedure is for centering the RNIVS and marking the
duct cutouts. Have a marking tool and tape measure ready.
1. Using the appropriate model below, mark the cooking
unit centerline (see image at right).
10 23/32”
(27.7 cm)
6”
(15.2 cm)
C
L
C
L
C
L
L
(14.5 cm)
6”
(15.2 cm)
10 23/32”
(27.7 cm)
5 3/4”
6 3/16”
(15.7 cm)
6 3/16”
(15.7 cm)
5 3/4”
(14.5 cm)
Four corners are
bent backward 90
degrees.
Attaching the ATD10
1. Center the ATD10 transition kit over the duct collars.
2. Drill holes for screws in the flanges. Make sure the holes
pierce the top of the RNIVS (see right).
3. Fasten the ATD10 into place using sheet metal screws
(not included).
4. Seal the base of the ATD10 with foil or duct tape.
13
2. Measure the top exhaust CL dimensions overhead.
3. Cut a hole 1” larger than the duct size you are using.
(Dual exhaust models require two holes.)
Page 16
Installation Instructions
Installing the RNIVS
WARNING
Installing the RNIVS requires two people.
Do not attempt to lift and hold the RNIVS without assistance.
Wear protective gloves while holding the unit. Sharp edges can cause injury to hands and fingers.
NOTE: If using a liner kit with the RNIVS, please
follow the instructions on page 13.
When hanging the RNIVS, be careful not to scratch or
damage the unit.
1. Remove the plastic film from the RNIVS.
2. Install a 3/8” spacer on the back of the RNIVS, or
install a spacer on the canopy or wall.
Refer to the figures on the facing page.
3. Choose and measure the top and rear mounting holes
that will mount the RNIVS to the canopy or wall. See
figure, Mounting Holes at right.
Mark the measurements on the canopy or wall.
This is where screws will hold the RNIVS to the wall
studs or anchors.
4. Drill pilot or anchor holes. If using anchors, insert them
into the anchor holes.
5. Raise and adjust the RNIVS into its final position, and
fasten it into place using appropriate mounting screws
or fastening hardware.
NOTE: If using the RNIVS without a liner kit, use
a 3/8” spacer.
See the next page.
T
T
R
R
14
Top mounting holes
T
R
Rear mounting holes
Mounting Holes
Page 17
Installation Instructions
.40
Adding a Spacer
If using the RNIVS without a liner kit, use a
3/8” spacer:
The flange circling the bottom of the unit will not
allow the unit to lay flat against a wall.
Therefore, use a 3/8” spacer behind the rear
mounting holes to ensure that the unit lays flush
against the wall or canopy.
See images below that illustrate the 3/8” flange extension that prevents the unit from being flush against a
wall.
3/
8”
(1.0 cm)
depth
back channel
2 1/
8”
height
(5.04 cm)
The image Channel Dimensions is for added
information only. These dimensions are not critical
for standard installation.
flange
Flange Creating Gap Between
Rear of Unit and Wall
Detail
3/
8”
(1.0 cm)
wall
Channel Dimensions
3/
(1.0 cm)
8”
channel depth
channel height
2 1/
8”
(5.04 cm)
flange
3/
flange extension length
8”
Details of Flange and Channel Dimensions
(1.0 cm)
15
Page 18
Installation Instructions
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
Hardwiring the Hood
WARNING
• To avoid electric shock or fire hazard, make sure that
power to the RNIVS power supply line is turned OFF
at the fuse box or circuit breaker before connecting
the electrical wiring.
• Miswiring the RNIVS electrical wiring can create an
electric shock or fire hazard and could damage the
RNIVS’ electrical system. See page 25-26.
• Do not ground the wires to the neutral (white) wire.
Connect the ground wire to a separate, properly
grounded ground-wire installed by a licensed electrician.
• Make sure that all wire used is the correct gauge and
capable of handling the total connected loads and
meeting all codes.
The above right diagram shows how to wire the blower(s)
to the RNIVS control panel.
The lower right diagram shows how to hardwire the unit to
the home’s circuit breaker (main power source).
remote blower series: REMP or ILHSF
wiring terminal inside unit
GREEN
WHITE
BLACK
wires from in-line/remote
blower
wires connected to hood
wiring harness, do not remove
Control Panel Wire Diagram
To Circuit Breaker
or Fuse Box
Not used
Gnd
N1
L1
GREEN
WHITE
BLACK
To Hardwire the RNIVS to the Main Power Source:
1. Follow the illustration at right called Junction Box
Wire Diagram.
Junction Box
To RNIVS
16
Junction Box Wire Diagram
Page 19
Installation Instructions
Grounding to a Cold-Water Pipe
WARNING
• Do not ground the circuit to a gas line.
• Do not ground the circuit to a hot water pipe.
• Water lines that are insulated must be jumped to
assure continuity to ground. See below.
To ground the RNIVS to a cold water pipe, refer to the
images on this page.
To house circuit breaker
or fuse box
Meter
No. 4 copper
wire
Clamps
Bare metal
Metal Cold Water Pipe
(detail)
Separate No. 10 (minimum)
copper ground wire
Wire nut,
3 places
GREEN
GREEN
UL/CSA approved
NEMA strain relief
WHITE
WHITE
BLACK
BLACK
To RNIVS
Grounding Using an External Cold Water Pipe
Fasten clamp tightly
on metal pipe
Junction box
17
Page 20
Installation Instructions
Inserting Dimmable Light Bulbs
Size: PAR16, E26/27
75 Watt max., 60 Amp
Make sure dimmable bulbs are used. The electronic board
is designed for dimmable light bulbs and using non-dimmable types will cause damage and faulty performance.
Shut the main circuit breaker OFF while inserting new
bulbs or while changing bulbs. If an electrical short occurs
while the main power circuit is ON, significant damage can
occur.
Follow the diagram to the right.
1. Insert a bulb into one of the light sockets.
2. Attach the suction cup to the lens of a dimmable light
bulb. (Both are supplied parts.)
Make sure the bulbs are clean and dry so the suction cup will stick.
3. Screw it into place and remove the suction cup.
4. Repeat for the remaining light fixtures.
5. Switch the main circuit power ON.
1
2
Verifying the Setup
FAN
knob
Verify the setup to ensure everything functions correctly:
1. Turn the power ON at the circuit panel or fuse box.
2. Assemble the filters if not already done so.
3. Insert the filters gently:
Be careful not to scratch the back of the grease
channel!
• Raise the front edge into the tension clip, and press
forward.
• Lift the rear edge up and above the grease channel.
Use caution not to scratch the filter against the grease
channel or scratch other parts of the unit or filters.
• Set the rear edge onto the grease channel.
4. Turn the LIGHTS knob. Twist the knob half-way around
for the lights to illuminate.
5. Turn the LIGHTS knob in the opposite direction to turn
the lights off.
6. Turn the FAN knob. The fan(s) will start at maximum
speed and decrease as you continue.
7. Turn the FAN knob in the opposite direction to turn the
fan(s) off.
Control Panel
LIGHTS
knob
Inserting Light Bulbs with the
Suction Cup Tool
Replacement Part
Number
702666
700975
TIP: Replace all bulbs when changing from LED to
Halogen because of the difference in light color.
18
Replacement Kit
Description
Dimmable LED 7.5W
(1 bulb + 1 suction cup)
Halogen Bulb 75W
(1 bulb + 1 suction cup)
If the RNIVS Fails to Function Correctly:
1. Verify that power is supplied to the RNIVS via the outlet, circuit breaker, or another main power source.
2. Make sure the electrical supply has not been disrupted
by a blown fuse or problems in the outlet or service.
3. Check the electrical connections to ensure that the
wiring installation has been completed correctly.
4. Repeat the above steps.
• If the RNIVS still does not work, contact Dacor
Customer Assurance: 833-35-ELITE (833-353-5483).
• Do not attempt to repair the appliance yourself.
• Dacor is not responsible for service required to correct
a faulty installation.
Page 21
Installation Instructions
FRONT
BACK
tension clip
Inserting Filters: Front Edge
The Installation Checklist
WARNING
• To ensure a safe and correct installation, the following checklist should be completed by the installer to
ensure that no part of the installation has been overlooked.
• Proper installation is the responsibility of the homeowner. The importance of proper installation of your
Dacor range RNIVS cannot be overemphasized.
□ Is the RNIVS properly attached to the canopy accord-
ing to the instructions on pages 18?
□ Is the ductwork completely installed? Are all joints
attached with sheet metal screws and wrapped with foil
tape? See page 13.
□ Is the RNIVS wired and grounded according to these
instructions and in accordance with all applicable electric codes? See pages 12, 23 and 25.
□ Has the setup been verified? See page 23.
Control Panel
Grease channel
Filter
Inserting Filters: Rear Edge
Dacor Replacement Parts
Part NumberDescription
702579
702580
702666
700975
Baffle Style Filter Kit
(1 Filter + Hardware)
Baffle Style Filter Kit
(2 Filters + Hardware)
Dimmable LED Bulb Kit
(1 Bulb + Suction Cup)
Halogen Bulb Kit
(1 Bulb + 1 Suction Cup)
□ Have any problems been noted on the warranty card or
during the on-line warranty activation?
□ Has the warranty been activated on-line or the warranty
card filled out completely and mailed?
The warranty card is located in the Use and Care booklet.
19
Page 22
RNIVS1 & RNIVSR1
Wiring Diagrams
CONNECT TO
120V 60Hz 15A
POWER SUPPLY
B
W
G
W
LAMP
DIMMER
FAN
SWITCH
HOOD
LIGHT 75W
HOOD
LIGHT 75W
B
G
W
B
B
B
B
FAN MOTOR
WIRING DIAGRAM
RNIVS1, RNIVSR1
RNIVSR1 DOES NOT
HAVE A FAN IN THE
UNIT; IT IS FOR A
REMOTE BLOWER ONLY
LIGHT
LIGHT
FAN
FAN
FOR
CONNECTION
TO ARLC/ARSC
/ARSLC
DISCONNECT POWER SUPPLY AT THE
FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
W
B
G
FOR
CONNECTION
TO REMOTE
BLOWER P/N:
ILHSF -8/10 OR
REMP -3/16
DACOR P/N:
109392
REV A
20
Page 23
RNIVS2 & RNIVSR2
Wiring Diagrams
CONNECT TO
120V 60Hz 15A
POWER SUPPLY
G
W
B
LAMP
DIMMER
FAN
SWITCH
HOOD
LIGHT 75W
W
LIGHT 75W
B
G
W
HOOD
B
B
B
B
FAN MOTOR
WIRING DIAGRAM
RNIVS2, RNIVSR2
RNIVSR2 DOES NOT
HAVE A FAN IN THE
UNIT; IT IS FOR A
REMOTE BLOWER ONLY
LIGHT
LIGHT
FAN
FAN
B
G
FOR
CONNECTION
TO ARLC/ARSC
/ARSLC
W
FAN MOTOR
CAUTION:
DISCONNECT POWER SUPPLY AT THE
FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
W
B
G
FOR
CONNECTION
TO REMOTE
BLOWER P/N:
ILHSF -8/10 OR
REMP -3/16
DACOR P/N:
109391
REV A
21