Dacor REMP3 Planning Guide

Page 1
REMP3, REMP16
Revised 10/16/13 Page 1/3
± 1/16” (± 1.6 mm) unless otherwise stated
19” (48.3 cm)
17 3/8” (44.1 cm)
9 1/2” (24.1 cm)
7 1/2”
(19.1 cm)
(10.2 cm)
C L C
L
Exhaust
Intake collar
C
L
C
L
24 1/4”
(61.6 cm)
25 1/2”
(64.8 cm)
Power supply conduit hole
Cutout location
11” W x 12 5/8” H
(27.9 cm X 32.1 cm)
Renaissance® Remote Blowers
• Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the hood or downdraft vent system installation instructions.
4”
2 1/8”
(5.4 cm)
Mounting
flange
3 5/8”
(9.2 cm)
9 1/4”
(23.5 cm)
7 15/16”
(20.2 cm)
5 13/16”
(14.8 cm)
Discharge
8” Nom.
(20.3 cm)
Intake collar
PLANNING
GUIDE
WARNING
REMP3 OVERALL DIMENSIONS
(TOP AND SIDE VIEWS)
33 1/2”
32 1/4”
(81.9 cm)
26” (66.0 cm)
24 1/4” (61.6 cm)
C L C
L
Power supply conduit location
Cutout location
13” W X 16 5/8” H
(33.0 cm X 42.2 cm)
Exhaust
13 1/8”
(33.3 cm)
9 1/2”
(24.1 cm)
(10.2 cm)
Intake collar
4”
C
L
C
L
2 1/8”
(5.4 cm)
Mounting
flange
3 5/8”
(9.2 cm)
12 1/4”
(31.1 cm)
REMP16 OVERALL DIMENSIONS
(TOP AND SIDE VIEWS)
11 1/2”
(29.2 cm)
9 9/16”
(24.3 cm)
10” Nom. (25.4 cm)
Intake collar
Discharge
Model No.
REMP3
Electrical Supply
Requirements
Refer to downdraft
vent or hood
REMP16 120 Vac, 2.7 Amp.
specications
Maximum Duct
Length
Refer to downdraft
vent or hood speci-
cations
Total Connected
Load
120 Vac, 3.8 Amp.
All specications subject to change without notice.
Blower Rating*
600 CFM (nominal)
620.5 CFM (actual)
1000 CFM (nominal)
994.8 CFM (actual)
* At 0" static pressure
Approximate
Shipping Weight
35 lbs.
55 lbs.
Phone: (800) 793-0093www.dacor.com
Finish
Galvanized
(may be painted)
Page 2
REMP3, REMP16
Revised 10/16/13 Page 2/3
Renaissance Remote Blowers
REMP3 Blower Performance
5.0
4.0
3.0
2.0
1.0
Static pressure - inches of water
0
100 200 300 400 500 600 700
Airflow CFM (Cubic feet/minute)
PLANNING
GUIDE
REMP16 Blower Performance
2.5
2.0
1.5
1.0
0.5
Static pressure - inches of water
0
200 400 600 800 1000
Airflow CFM (Cubic feet/minute)
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
Page 3
Blower
Roof
Exhaust
Blower
Duct
Wiring/conduit
Wiring/conduit
Duct
Wall
No obstructions within 15 inches of exhaust
Exhaust
REMP3, REMP16
Revised 10/16/13 Page 3/3
Renaissance Remote Blowers
EXAMPLE REMP
ROOF INSTALLATION
SIDE VIEW
PLANNING
GUIDE
EXAMPLE REMP
WALL INSTALLATION
SIDE VIEW
(EXHAUST MUST
POINT DOWN)
Roof curb
Prevailing wind
Blower discharge
REMP FLAT ROOF INSTALLATION
TOP AND SIDE VIEWS (SEE NOTE 2)
+/- 1/16” (+/- 1.6 mm) unless otherwise stated
2"
(5.1 cm)
2"
(5.1 cm)
25 1/2"
(64.8 cm)
19"
(48.3 cm)
ROOF CURB DIMENSIONS
REMP3
23 ¼"
(59.1 cm)
6"
(15.2 cm)
2”
(5.1 cm)
33 1/2”
(85.1 cm)
26"
(66.0 cm)
ROOF CURB DIMENSIONS
REMP16
2”
(5.1 cm)
30 1/2”
(77.6 cm)
NOTE:
1. The REMP chassis may be rotated to clear obstructions. 15” (38.1 cm) min. clearance must be maintained from the air discharge to any obstruction. In cold climates, take into account snow accumulation which can also act as an obstruction.
2. When mounting in a horizontal position, shield the REMP to protect from possible water collection in the chassis. Maintain a minimum down slope of 1/4” (6 mm) per foot for evacuation of water.
3. When the REMP is installed on to a flat (less than a 2:12 pitch) roof, a roof curb is required.
4. The blower discharge must be pointed in the same direction as the prevailing wind.
6”
(15.2 cm)
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com