Transition ATD-2 included
Four optional exhaust directions: right or left sides, bottom or back
Ventilation Solutions
SPECIAL NOTES
V30, 36, 46 designed for RSD30, RSE30, MRES30, SGM304, SGM364,
PR
365, 466, 464GG, PGM304, PGM365, MET, ETT, CER
Page 9
9
Accessories
Remote Blower
REMP3 (pictured)
REMP16
APPLICATIONS:
Use with EHDR, IVSR, RV,
ERV or PRV systems
Stainless Steel Liners for PowerPacks
SIZES
Available in five widths:
30," 36," 42," 48" & 54"
IHL30 & IHL36
Use with IVS1 & IVSR1
IHL42, IHL48 & IHL54
Use with IVS2 & IVSR2
Internal Blower
CABP3
APPLICATIONS:
Install with RV model
downdrafts only
Stainless Steel Duct Covers
SIZES
Available in five widths:
30," 36," 42," 48" & 54"
All widths available
in three heights:
6," 12" & 18
ATD10 Transition
Use with all IVS2 & IVSR2
Use with EHD, EHDR4209,
EHDR4809 & MHD4809
Ventilation Solutions
Remote Control Speed Switch
ARSC
Install as remote control
for all blower systems
ARLC
o control lights
T
ARSLC
ol both
o contr
T
blower & lights
Page 10
0
1
In-Line Blowers
ILB 8
POWER
600 CFM
VENTING
" round duct
8
APPLICATIONS
SUPPLEMENTAL BLOWER–
Use in conjunction with internal or remote blowers.
MAKE-UP OR REPLACEMENT AIR SYSTEM–
Some local HVAC codes require make-up air if you are
using a vent system with 1000 or more CFM. The ILB's
are a great source for this. Have your builder contact
their HVAC contractor to see if this is required in your area.
SPECIAL NOTE
ILB8 cannot be used with downdraft ventilation.
ILB 10
POWER
1100 CFM
VENTING
10" round duct
APPLICATIONS
SUPPLEMENTAL BLOWER–
Use in conjunction with inter
MAKE-UP OR REPLACEMENT AIR SYSTEM–
Some local HVAC codes require make-up air if you are
using a vent system with 1000 or more CFM. The ILB's
e a great sour
ar
their HVAC contractor to see if this is r
SPECIAL NOTE
ILB10 cannot be used with downdraft ventilation.
ce for this. Have your builder contact
nal or remote blowers.
equired in your area.
Ventilation Solutions
Page 11
1
1
Creating the Proper Ventilation System 1
Select Cooking Product
OOKING PRODUCT
C
M
ODEL
RO-HOOD
P
INTEGRATED VENT
SYSTEM
VER THE RANGE (OTR)RAISED VENT SYSTEM
O
RD60S
E
ERD48S
ERD36S
ERD30S
EGR30S
ESG486S
ESG366S
SGM464GG
SGM466
EHD5418 or EHDR5418
EHD4818 or EHDR4818
EHD4809 or EHDR4809
MHD4818
MHD4809
EHD4218 or EHDR4218
EHD4209 or EHDR4209
EHD3618 or EHDR3618
EHD3609 or EHDR3609
MHD3618
MHD3609
EHD3618 or EHDR3618
EHD3609 or EHDR3609
EHD3018 or EHDR3018
EHD3009 or EHDR3009
MHD3618 or MHD3018
MHD3609 or MHD3009
EHD5418 or EHDR5418
EHD4818 or EHDR4818
EHD4809 or EHDR4809
MHD4818
MHD4809
EHD4218 or EHDR4218
EHD4209 or EHDR4209
EHD3618 or EHDR3618
EHD3609 or EHDR3609
MHD3618
MHD3609
EHD4809 or EHDR4809
EHD4818 or EHDR4818
MHD4818
MHD4809
EHD4809 or EHDR4809
EHD4818 or EHDR4818
MHD4818
MHD4809
2–IVS1 or 2–IVSR1
Plus a custom
Stainless Steel Liner
IVS2 or IVSR2
Plus IHL54 or IHL48
IVS2 or IVSR2 + IHL42
IVS1 or IVSR1 + IHL36
IVS1 or IVSR1 + IHL36
IVS1 or IVSR1 + IHL30
IVS2 or IVSR2
Plus IHL54 or IHL48
IVS2 or IVSR2 + IHL42
IVS1 or IVSR1 + IHL36
IVS2 or IVSR2
Plus IHL54 or ILH48
IVS2 or IVSR2
Plus IHL54 or ILH48
NA
NA
NA
PCOR30 or PMOR3021
with ILB8 & ARSC
(with deflector shield)
NA
NA
NA
NA
ERV30
(one for each oven)
(must use remote blower)
NA
NA
ERV30 with ERD30S
(EGR30 not approved
for use with downdraft)
(must use remote blower)
ERV48
(must use remote blower)
ERV36
(must use remote blower)
V48
ER
(must use r
(must use r
(must use r
emote blower)
PRV46
emote blower)
RV46
(CAB or remote blower)
PRV46
emote blower)
Ventilation Solutions
Page 12
2
1
Creating the Proper Ventilation System 2
Select Cooking Product
OOKING PRODUCT
C
ODEL
M
SGM365
SGM364
PGM365
SGM304
MET365
ETT365
CERB365
MET304
ETT304
OOD
H
EHD4209 or EHDR4209
EHD3609 or EHDR3609
MHD3609
EHD3609 or EHDR3609
EHD3009 or EHDR3009
MHD3609 or MHD3009
EHD4209 or EHDR4209
EHD3609 or EHDR3609
MHD3609
EHD3609 or EHDR3609
EHD3009 or EHDR3009
MHD3609 or MHD3009
INTEGRATED VENT
SYSTEM
IVS2 or IVSR2 + IHL42
IVS1 or IVSR1 + IHL36
IVS1 or IVSR1 + IHL36
or IHL30
IVS2 or IVSR2 + IHL42
IVS1 or IVSR1 + IHL36
IVS1 or IVSR1
Plus IHL36 or IHL30
VER THE RANGE (OTR)RAISED VENT SYSTEM
O
ERV36 or RV36
(with appropriate
NA
PCOR30 or PMOR3021
(add ILB8 & ARSC if
you want 600 CFM)
NA
PCOR30 or PMOR3021
remote blower)
PRV36
(must use remote blower)
ERV30 or RV30
(with appropriate blower)
PRV30
(must use remote blower)
V36 or RV36
ER
opriate blower)
(with appr
PRV30
(must use remote blower)
ERV30 or RV30
(with appropriate blower)
PRV30
(must use remote blower)
RSD30
MRES30
EHD3609 or EHDR3609
EHD3009 or EHDR3009
MHD3609 or MHD3009
EHD3609 or EHDR3609
EHD3009 or EHDR3009
MHD3609 or MHD3009
IVS1 or IVSR1
Plus IHL36 or IHL30
IVS1 or IVSR1
Plus IHL36 or IHL30
PCOR30 or PMOR3021
(add ILB8 & ARSC if
you want 600 CFM)
PCOR30 or PMOR3021
ERV30 with RSD30
(must use remote blower)
PRV30
(must use remote blower)
ERV30
(must use remote blower)
PRV30
(must use remote blower)
Ventilation Solutions
Page 13
3
1
Creating the Proper Ventilation System 3
Build the Ventilation Package
STEP:
Select
Vent System/ Model
VENT SYSTEMSMODEL
o Hood – Internal
18" Pr
18" Pro Hood – External
9" Pro Hood – Internal
1
EHD3018
EHD3618
EHD4218
EHD4818
EHD5418
EHDR3018
EHDR3618
EHDR4218
EHDR4818
EHDR5418
EHD3009
EHD3609
EHD4209
EHD4809
2
Select
Blower
INTERNAL
OWER
P
Included
600 CFM
Included
1200 CFM
NAREMP3
NAREMP16
Included
600 CFM
Included
1200 CFM
EMOTE
R
POWER
NA
NA
NA
NA
35
Duct Size
Needed
DUCT SIZE
8" round60'REMP3
10" round50'REMP16
8" round60'REMP3
10" round50'REMP16
8" round60'REMP3
(2) 8" rounds
(with ATD10)
or 10" round
4
Max Length For
1 Blower Sys.
MAX LENGTH
Determine Duct
Length Incl.
Elbows & Trans.
DUCT LENGTH
50'REMP16
6
If Over Max
Length, Choose
Extra Blower(s)
EXTRA
LOWER
B
Ask builder
about
make-up air
Ask builder
about
make-up air
Ask builder
about
make-up air
9" Pro Hood – External
EHDR3009
EHDR3609
EHDR4209
EHDR4809
NAREMP3
NAREMP16
8" round60'REMP3
(2) 8" rounds
(with ATD10)
or 10" round
50'REMP16
Ask builder
about
make-up air
Ventilation Solutions
Page 14
4
1
Creating the Proper Ventilation System 4
Build the Ventilation Package
STEP:
Select
Vent System/ Model
VENT SYSTEMSMODEL
MHD3018
MHD3618
18" Millennia Hood
9" Millennia Hood
MHD4818
MHD3009
MHD3609
MHD4809
1
INTERNAL
OWER
P
Included
600 CFM
Included
1200 CFM
Included
600 CFM
Included
1200 CFM
2
Select
Blower
EMOTE
R
POWER
NA
NA
NA
NA
35
Duct Size
Needed
DUCT SIZE
8" round60'REMP3
10" round50'REMP16
8" round60'REMP3
) 8" rounds
2
(
with ATD10) or
(
10" round
4
Max Length For
1 Blower Sys.
AX LENGTH
M
Determine Duct
Length Incl.
Elbows & Trans.
UCT LENGTH
D
50'REMP16
6
If Over Max
Length, Choose
Extra Blower(s)
EXTRA
LOWER
B
Ask builder
about
make-up air
Ask builder
about
make-up air
Ventilation Solutions
Page 15
5
1
Creating the Proper Ventilation System 5
Build the Ventilation Package
STEP:
Select
Vent System/ Model
VENT SYSTEMS
PowerPacks – Internal
PowerPacks – External
Over the Range Microwaves
Downdraft RV
1
ODEL
M
IVS1
IVS2
IVSR1
IVSR2
PMOR30
PCOR30
RV30
2
Select
Blower
NTERNAL
I
POWER
Included
600 CFM
Included
1200 CFM
NAREMP3
NAREMP16
Included
300 CFM
CABP3
EMOTE
R
POWER
NA
NA
ILB8 &
ARSC
(if used
with ERD30
or EGR30)
REMP3 or
REMP16
35
Select
Liner & Transition
RANSITION
T
LINER
IHL36 or
IHL30
IHL54, IHL48
IHL42 or
IHL40
IHL36 or
HL30
I
IHL54, IHL48
IHL42 or
I
HL40
NA
NA
NA
ATD10
N
ATD10
NA
NA
Duct Size
Needed
DUCT SIZE
8" round
10" round50'
A
8
10" round50'
rectangle
31/4" x 10"
rectangle
4
Max Length
For 1
Blower Sys.
M
LENGTH
60'
" round60'
1
3
/4"
50'
40'
AX
Determine
6
Duct Length
Incl. Elbows
& Trans.
DUCT
ENGTH
L
If Over Max
7
Length,
Choose Extra
Blower(s)
EXTRA
LOWER
B
REMP3
REMP16
EMP3
R
REMP16
ILB8
REMP3 or
REMP16
Ask builder
about
make-up air
Ask builder
about
make-up air
Remove
internal
blower if
using the
ILB8 &
ARSC
combination
Ask builder
about make-
up air if unit
is over
1000 CFM
Downdraft ER
Downdraft PRV
REMP3 for
MRES or
NA
RSD ranges.
REMP3 or
REMP16 for
ERD30 or
ESG
cooktops
NA
NA
1
/4" x 10"
3
rectangle
40'
REMP3 or
REMP16
ERV30
ERV36
ERV48
V
PRV30
PRV36
V46
PR
NA
REMP3 or
REMP16
NA
NA
31/4" x 10"
rectangle
40'
REMP3 or
REMP16
Ask builder
about make-
up air if unit
is over
1000 CFM
Ask builder
about make-
up air if unit
is over
1000 CFM
Ventilation Solutions
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.