REMP3, REMP16
REMP
3 1/4" x 10" to
Round
Transistion
45° Adjustable
Elbow
Air
Discharge
17 1/8" (435mm)
5 13/16"
(148mm)
8"
(203mm)
19" (483mm)
7 13/16"
(198mm)
24 1/16"
(611mm)
3 5/8"
(92mm)
9 1/4"
(235mm)
Mounting
Flange
25 1/2"
(648mm)
7 1/2"
(191mm)
9 1/2" (241mm)
Discharge
Cutout
Location
Intake Collar
Intake Collar
C
L
C
L
CLC
L
Power Supply
Conduit
Location
Discharge
24" (610mm)
9 9/16"
(243mm)
10"
(254mm)
26" (660mm)
11 1/2"
(292mm)
31 1/2"
(800mm)
3 1/2"
(89mm)
12 1/4"
(311mm)
Mounting
Flange
33 1/2"
(851mm)
9 1/2"
(241mm)
12 11/16"
(322mm)
Discharge
Cutout
Location
Intake Collar
Intake Collar
C
L
C
L
CLC
L
Discharge
Power Supply
Conduit
Location
Remote Blowers
REMP SLOPED INSTALLATION
(Cutaway Side View)
PLANNING
1/2062805
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
REMP3 OVERALL DIMENSIONS
REMP16 OVERALL DIMENSIONS
(Top & Side Views)
(Top & Side Views)
Specifications are subject to change without notice.
See installation instructions for additional details.
9.3
REMP3, REMP16
15"
(381mm) Min.
(Either Side)
15"
(381mm)
Minimum
Return Wall
(Either Side)
Exterior
Grade Level
Arc of
Rotation
Arc of
Minimum Clearance
to Obstructions
Air
Discharge
25 1/2"
(648mm)
2"
(51mm)
19"
(483mm)
23 1/4"
(591mm)
6"
(152mm)
2"
(51mm)
33 1/2"
(851mm)
2"
(51mm)
26"
(660mm)
30 1/2"
(776mm)
6"
(152mm)
2"
(51mm)
REMP CHASSIS ROTATION
(Exterior Wall View)
Remote Blowers
NOTE:
1. The REMP chassis may be rotated to clear
obstructions. 15” (381mm) min. clearance must
be maintained from the air discharge to any
obstruction. When mounting in a horizontal
position, shield the REMP to protect from possible
water collection in the chassis. Maintain a
minimum down slope of 1/4” (6mm) per foot for
evacuation of water.
2. When the REMP is installed on to a flat (less than a
1:12 pitch) roof, a roof curb is required.
PLANNING
2/2091805
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
ROOF CURB DIMENSIONS
REMP WITH ROOF CURB
(Top & Side Views)
Model No.
REMP3
REMP16 0.03kW (3A) 1600 CFM 72 lbs.
Dedicated Circuit
Refer to Ventilator
Required
Specifications
Maximum Duct
Length
Refer to Duct
Planning
Specifications
Total Connected
Load Blower Rating
0.05kW (4A) 1000 CFM 40 lbs.
Specifications are subject to change without notice.
See installation instructions for additional details.
ROOF CURB DIMENSIONS
REMP3
REMP16
Approximate
Shipping Weight Finish
Galvanized
(may be painted)
9.4