Dacor REMP16, REMP3 User Manual

Remote Blowers
Models: REMP3, REMP16
Installation Instructions
Part No. 65265 Rev. J
Suitable for use in a household cooking area.
Suitable for use with solid state controls.
To complete this blower, a Dacor
must be purchased separately. See the hood or downdraft vent installation
instructions to determine suitability.
hood assembly or Dacor downdraft vent
Table of Contents
Important Safety Instructions .......................................... 1
Important Information About Safety Instructions .............. 1
Safety Symbols and Labels ............................................. 1
General Safety Precautions ............................................. 2
Product Specifications ..................................................... 2
Electrical Supply Requirements ....................................... 2
Product Dimensions ......................................................... 3
Installation Requirements ................................................ 4
Installation Planning ......................................................... 4
Installation Preparation .................................................... 5
Installation Instructions .................................................... 6
Parts List .......................................................................... 6
Installation ........................................................................ 6
Verifying Proper Operation ............................................... 7
Technical Data ................................................................... 8
REMP Series Blower Ratings .......................................... 8
Before You Begin...
Important:
• Installer: In the interest of safety and to minimize problems, read these installation instructions completely and care-
fully before you begin the installation process. Leave these installation instructions with the customer.
• Customer: Keep these installation instructions for future reference and the local electrical inspector’s use.
Customer Service Information
If You Need Help...
Model Identification
If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team. For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line.
Dacor Customer Service Team
Phone: (800) 793-0093 ex. 2813 (U.S.A. and Canada) Monday — Friday 6:00
Web site: www.dacor.com
Dacor Distinctive Service (for repairs under warranty only)
Phone: (800) 793-0093 ex. 2822 (U.S.A. and Canada) Monday — Friday 6:00
a.m. to 5:00 p.m. Pacific Time
a.m. to 5:00 p.m. Pacific Time
REMP3 = Remote blower with 8-inch diameter intake
REMP16 = Remote blower with 10-inch diameter intake
All specifications subject to change without notice. Dacor assumes no liability for changes to specifications.
© 2008 Dacor, all rights reserved.
Important Safety Instructions
Important Information About Safety Instructions
• The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or oper­ating this or any other appliance.
• Always contact the Dacor Customer Service Team about problems and conditions that you don’t under­stand. See Customer Service Information.
DANGER
IMPORTANT: Do not store or use combustible,
flammable or explosive vapors and liquids (such as gasoline) inside or in the vicinity of this or any other appliance. Also keep items that could explode, such as aerosol cans, away from the range or cooktop. Do not store flammable or explosive materials in adjacent cabinets or areas.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warn­ing device, such as a tag, to the service panel.
Safety Symbols and Labels
DANGER
Immediate hazards that WILL result in severe personal injury or death.
WARNING
Hazards or unsafe practices that COULD result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that COULD result in minor personal injury or property damage.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done
by qualified person(s) in accordance with all appli­cable codes and standards, including fire-rated con­struction.
b. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guide­line and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
d. Ducted fans must always be vented to the outdoors.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors.
READ AND SAVE THESE INSTRUCTIONS
1
Important Safety Instructions
General Safety Precautions
To reduce the risk of fire, electric shock, serious injury or death when using this blower, follow basic safety precautions, including the following:
WARNING
• Do not install or operate this unit if it has been dam­aged, dropped, has damaged electrical wiring or is not working properly. If you receive a damaged product, immediately contact the dealer or builder.
• Install or locate this appliance only in accordance with these installation instructions and the Dacor hood or downdraft vent installation instructions. Improper installation, adjustment, alteration, service or maintenance can cause serious personal injury or property damage.
• Before installing or servicing the blower, make sure that power to the wiring is turned off at the circuit breaker or fuse box. Make sure that the service panel is locked or tagged to prevent power from being switched on accidently.
• A minimum of two people are required to safely install this appliance.
• The installer must show the customer the location of the fuse or circuit breaker panel so that the cus­tomer knows where and how to turn the power off.
• To reduce the risk of electric shock or fire, the total combined current draw of the in-line blower and the hood or downdraft vent must not exceed the maxi-
WARNING
mum rated input current of the hood or downdraft vent.
• Never allow the filters or vent openings on the hood or downdraft vent to become blocked or clogged. Do not allow foreign objects, such as cigarettes or napkins, to be sucked into the vent holes.
• Tape all duct joints securely to prevent combus­tion by-products, smoke or odors from entering the home. Doing so will also improve system efficiency.
• Do not route electrical wiring near hot surfaces.
• Do not ground the appliance with the neutral (white)
house supply wire. A separate ground wire must be utilized.
• To prevent a damaged or non-functional system, complete electrical connections properly. Follow the wiring diagrams carefully in the hood or in-line blower installation instructions to ensure a proper installation. After installation or service, make sure that all blower wires are tightly connected to their respective terminals.
Product Specifications
Electrical Supply Requirements
• The power for this blower is supplied via 1/2” 3-wire wiring/conduit (not included) by an approved Dacor hood or downdraft vent. The wiring/conduit is installed between the hood or downdraft vent and the blower and shall be terminated on each end by a 1/2” UL certi­fied strain relief. The power is turned on and off by the power switch on the approved ventilation device.
• The correct voltage, frequency and amperage must be supplied to the hood or downdraft vent and the blower from a grounded, single phase circuit that is protected by a properly sized circuit breaker or time-delay fuse. The circuit must have the capacity to supply the com­bined power requirements for the hood or downdraft vent and the in-line blower. See the installation instruc­tions for the hood or downdraft vent to determine total power requirements in combination with the blower electrical specifications.
Model* Power Requirements** Blower Rating***
REMP3 120 Vac, 60 Hz., 3.8 Amp. 600 CFM
REMP16 120 Vac, 60 Hz., 2.7 Amp. 1000 CFM
* All models are thermally protected. ** In addition to the hood or downdraft vent. *** Nominal rating at 0 inches static pressure. See Technical Data section for actual ratings.
• The above specifications are for reference only, See the data label on the blower for exact specifications. If the above specifications vary from the label on the blower, use the data on the blower label.
• It is the owner’s responsibility to ensure that the power supply is installed by a licensed electrician. The electri­cal installation must comply with the latest revision of the National Electric Code ANSI/NFPA 70 (latest revi­sion) and local codes and ordinances. A copy of the specification may be obtained from: