36 1/4" *
(921 mm)
34 3/8"
(873 mm)
19 3/8"
(495 mm)
21 1/4" *
(540 mm)
4" (102 mm)
Chassis height
30 1/4" *
(768 mm)
28 3/8"
(721 mm)
19 3/8"
(495 mm)
21 1/4" *
(540 mm)
4" (102 mm)
Chassis height
ETT304-1, ETT365-2, MET304 and METB365-1
Document # PG03 - 001 Revised 08/20/09 Page 1/3
30 Inch and 36 Inch Wide,
Millennia® Electric Cooktops
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
PRODUCT DIMENSIONS - ETT304-1 AND MET304
(ETT304-1 SHOWN)
PLANNING
GUIDE
WARNING
Observe all governing codes and ordinances during planning •
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the •
accompanying installation instructions.
* For units with stainless steel trim, other units may be up to 1/8" less.
Model No. Electrical Circuit Required
ETT304-1 240 Vac, 60 Hz, 40 Amps. 6.9 kW (29 Amps.)
ETT365-2 240 Vac, 60 Hz, 40 Amps. 9.1 kW (38 Amps.)
MET304 240 Vac, 60 Hz, 40 Amps. 6.9 kW (29 Amps.)
METB365-1 240 Vac, 60 Hz, 50 Amps.* 9.6 kW (40 Amps.)
* For reference only, See the product data label on bottom of unit for exact specifications.
Phone: (800) 793-0093
www.Dacor.com
PRODUCT DIMENSIONS - ETT365-2 AND METB365-1
Total Connected
Load*
ELECTRICAL SUPPLY REQUIREMENTS
NOTES:
The cooktop is supplied with a flexible, 48 inch long 1.
power conduit consisting of two (2) insulated hot lead
conductors (L1 and L2) and one (1) insulated ground
conductor. There is no neutral connection. All leads are
copper. The conduit is connected to the right corner of
the cooktop. Do not connect the ground wire to neutral.
Tested in accordance with the latest edition of ANSI 2.
Z21.1 and U.L. 858 Standard for household cooking
appliances.
These cooktops are not approved for recessed 3.
installation.
Specications are subject to change without notice.
See installation instructions for additional details.
(ETT365-2 SHOWN)
Minimum Supply Wire Size
Line and Ground Connections
No. 8 AWG
3.1

ETT304-1, ETT365-2, MET304 and METB365-1
6” (152 mm)
Min. clearance
to combustible
surfaces
A
6" (152 mm) Min.
from mounting surface to
combustibles below
cooktop chassis
B
Min. overhang,
both sides
Rear
wall
1" Min.
19 3/4" Min.
(502 mm)
1" (25 mm)
(25 mm)
1" Min.
(25 mm)
Document # PG03 - 001 Revised 08/20/09 Page 2/3
30 Inch and 36 Inch Wide,
Millennia® Electric Cooktops
Allow a minimum of 6 inches (152 mm) clearance between
the top of the countertop and any combustible surface
below, including the upper edge of a drawer below the
cooktop. Proper under-cabinet clearance is also required
for the cooktop hold down brackets.
Model
ETT304-1, MET304 30 1/2” (775 mm)
ETT365-2, METB365-1 36 1/2” (927 mm)
A - Minimum Under Counter
Clearance (Width)
PLANNING
GUIDE
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
When installing model ETT365-2 or METB365-1 and the bottom of the chassis is
to be enclosed wall to wall, you must install Dacor ventilation duct kit ATD323.
Cooktop cutout in
top of cabinet
7 3/4” X 4 3/8”ventilationcut-outsinenclosureoor
3
/4”
1 1/2”
1 1/2”
3
/4”
UNDER COUNTER CLEARANCE
Model
ETT304-1, MET304 28 3/4” (730 mm)
ETT365-2, METB365-1 34 3/4” (883 mm)
B - Minimum Under Counter
Clearance (Width)
TOP VIEW VENTILATION CUTOUT
www.Dacor.com
Phone: (800) 793-0093
COUNTERTOP CUTOUT (WITHOUT RAISED VENT)
Specications are subject to change without notice.
See installation instructions for additional details.
3.2

Stiffener
Cabinet face
Countertop
Floor
3/8” Min. (10 mm) space
behind raised vent
chassis to clear stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
ETT or MET series cooktop
19 3/4"
(502 mm)
1" Min.
(25 mm)
1" Min.
(25 mm)
1" Min.
(25 mm)
Cabinet
face
A
B
C
D
E
6" (152 mm) Min.
from mounting surface to
combustibles below
cooktop chassis
Rear
wall
Stiffener
Cabinet face
Countertop
Floor
5/8” Min. (16 mm) space
behind raised vent
chassis to clear stiffener
5/8” Min. (16 mm)
flat countertop overhang
required behind cutout
RV series raised vent:
Check raised vent
dimensions/specifications
to determine proper fit
ETT or MET series cooktop
ETT304-1, ETT365-2, MET304 and METB365-1
Document # PG03 - 001 Revised 08/20/09 Page 3/3
30 Inch and 36 Inch Wide,
Millennia® Electric Cooktops
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
PLANNING
GUIDE
ERV AND PRV SERIES RAISED VENT INSTALLATION
COUNTERTOP CUTOUT (WITH RAISED VENT)
ETT304-1 or MET304 cooktop with ERV30
or PRV30 raised vent
ETT304-1 or MET304 cooktop with
RV30 raised vent
ETT365-2 or METB365-1 cooktop with
ERV36 or PRV36 raised vent
ETT365-2 or METB365-1 cooktop with
RV36 raised vent
Model/Configuration
SIDE VIEW
TOP VIEW
www.Dacor.com
Phone: (800) 793-0093
A - Cooktop
Cutout Width
28 3/4”
(730 mm)
34 3/4”
(883 mm)
B - Raised Vent
Cutout Width
27 3/4”
(705 mm)
33 3/4”
(857 mm)
RV SERIES RAISED VENT INSTALLATION
COUNTERTOP CUTOUT (WITH RAISED VENT)
C - Total Cutout
Depth
22 1/2”
(572 mm)
22 1/4”
(565 mm)
22 1/2”
(572 mm))
22 1/4”
(565 mm)
SIDE VIEW
ISO VIEW
D - Raised Vent
Cutout Depth
2 3/4”
(70 mm)
2 1/2”
(64 mm)
2 3/4”
(70 mm)
2 1/2”
(64 mm)
Specications are subject to change without notice.
See installation instructions for additional details.
E - Minimum
Rear Countertop
Overhang
3/8”
(10 mm)
5/8”
(16 mm)
3/8”
(10 mm)
5/8”
(16 mm)
3.3