Dacor ERD60, AESP03, ERD30, ERD60LP User Manual

0 (0)
Dacor ERD60, AESP03, ERD30, ERD60LP User Manual

ERD60

 

 

 

 

 

 

 

 

 

 

 

 

Revised

 

 

 

 

60” Wide,

 

 

PLANNING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Epicure® Range

1/2

GUIDE

 

 

 

 

 

 

 

 

 

 

 

 

06/25/08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28 1/2" (724mm)

 

 

 

 

 

Handle

 

 

 

warning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27" (686mm)

 

 

 

 

Front Edge of Bullnose

 

Observe all governing codes and ordinances during

 

 

 

 

 

 

 

 

 

 

 

 

 

26" (660mm)

 

 

 

 

 

 

Face of Control Panel/Oven Door

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

planning and installation. Contact your local building

 

 

 

 

 

 

 

 

 

 

 

 

24 3/8" (619mm)

 

 

 

 

Rear of Control Panel/Oven Door

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

department for further information.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This appliance must be installed in accordance with the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6” (152mm) Backguard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

accompanying installation instructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 9/16" (40mm)

When Backguard and Side Panels are

removed, the overall depth decreases

by 1" (25mm)

37”

(940mm) to

35 3/4" (908mm)

60" (1524mm)

Finished Side Panel

6" (152mm) Backguard

Accessory 3” (76mm) Side Panels

(Dacor Model No. AESP03)

erd/eGR30, erd60 overall dimensions side view

 

 

Power Cords

 

Factory installed 3/4” regulators

 

 

 

 

 

(1/2” supply ok)

 

 

 

 

rear view

 

 

 

 

 

 

 

 

 

 

Total

 

 

 

 

Dacor®

Dedicated Circuit*

Connected

 

Gas

Manifold

Min. Gas Supply

Model No.

Required

Load

 

Type

Pressure

Pressure

ERD60

240 Vac, 4-wire, 60 Hz,

4.1 kW

 

Natural

5” Water Column

6” Water Column

ERD60LP

 

Liquid

 

 

30 Amp (Breaker) X2

(21Amp) X2

 

10” Water Column

11” Water Column

 

 

Propane

 

 

 

 

 

 

*Two separate dedicated circuits are required, one for left and one for the right side of the range.

Electrical AND GAS Supply Requirements

NOTES:

1.Utilities may be located in the lower left corner of the adjacent right cabinet. (Recommended)

2.Contact your local building department to verify compliance with local code interpretation.

3.Two electrical circuits and gas supplies required.

Web: http://www.Dacor.com

Specifications are subject to change without notice.

5.7

Corporate Phone: 800-793-0093

See installation instructions for additional details.