CER304, ETT304, MET304,
1” (25mm) to Combustible Rear Wall
0” (0mm) to Non-Combustible Rear Wall
“A”
21”
(533mm)
6” (152mm) Min.
from edge of cooktop
to combustible
side wall above
finished countertop
(both sides)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
19 7/8”
(505mm)
1 3/4” (44mm) to Combustible Rear Wall
3/4” (19mm) to Non-Combustible Rear Wall
Flush with
backside of
cabinet front
“B”
25”
(635mm)
7” Min. from edge of
cutout to combustible
side wall above
finished countertop
(both sides)
2”
(51mm)
CERB365, ETT365, METB365
30”, 36” Wide,
Millennia™ Electric Cooktops
OVERALL DIMENSIONS
(MET304 Shown)
PLANNING
1/2092105
GUIDE
Models “A” Cooktop Width “B” Cooktop Cutout Width
30” 30” (762mm) 28 1/2” (724mm)
36” 36” (914mm) 34 1/2” (876mm)
Web: http://www.dacor.com
Corporate Phone: 800-793-0093
TOP VIEW COUNTERTOP CUTOUT
Specifications are subject to change without notice.
See installation instructions for additional details.
3.1
L65334 rev D
CER304, ETT304, MET304,
30" (762mm) Minimum
from finished countertop to combustible/
non-combustible surface
"C"
18” (457mm) Min.
Both Sides
6” (152mm) Min.
from edge of cooktop
to combustible side wall
above finished countertop
(both sides)
4” (102mm) Chassis height
2” (51mm) Min. to
combustibles below chassis
Recommended Utility Location
CERB365, ETT365, METB365
30”, 36” Wide,
Millennia™ Electric Cooktops
PLANNING
2/2091605
GUIDE
Models “C” Min. Hood Width “C” Recommended Hood Width
30” 30” (762mm) 36” (914mm)
36” 36” (914mm) 42” (1067mm)
Model
No.
CER304
CERB365
ETT304
ETT365
MET304
METB365
Dedicated Circuit
Required
240VAC, 60Hz,
30A (Breaker)
240VAC, 60Hz,
50A (Breaker)
240VAC, 60Hz,
30A (Breaker)
240VAC, 60Hz,
40A (Breaker)
240VAC, 60Hz,
50A (Breaker)
Total Connected
Load
240VAC 6.9kW
(29A)
240VAC 9.6kW
(40A)
240VAC, 6.9kW
(29A)
240VAC 8.9kW
(37A)
240VAC 6.9kW
(29A)
240VAC 9.6kW
(40A)
Shipping Weight
UPPER CABINET DIMENSIONS
(Upper Cabinets 13” (330mm) Maximum Depth)
Approximate
NOTES:
1. Cooktop is supplied with a 48” (1219mm) flexible
55 lbs.
conduit.
2. The Cooktops are not approved for recessed
64 lbs.
installation.
3. All power conduits are located in the back right
45 lbs.
53 lbs.
45 lbs.
54 lbs.
corner of the Cooktop.
4. See the Combination Installation (CI) Section if
installing with a downdraft, wall oven, or warming
oven.
Web: http://www.dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
3.2
L65334 rev D