WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
A
PRODUCT DIMENSIONS - ISO VIEW
A - Width
DYRTP366 35 7/8” (91.1 cm)
DYRTP486 47 7/8” (121.6 cm)
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire) 0.25 Amp @ 120 Vac, 60 Hz
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type Manifold Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
* Maximum gas supply pressure for all models is 1/2 psi
IMPORTANT: Installation of a non-combustible material (up to the hood)
or a backsplash is always recommended, and mandatory if the distance
to the back wall from the rangetop is less than 2 1/2” (Figure 2). When
installing a backguard, use only Dacor model numbers AEB3609, AEB3612
(DYRTP366), AEB4809 or AEB4812 (DYRTP486). Consult local codes and
ordinances for acceptable non-combustible materials.
Combustible
rear wall
2 1/2” (6.4 cm) min. to
combustible rear wall
Minimum Gas Supply
Pressure
27 5/16” (69.4 cm)
26 5/16” (66.8 cm)
25 3/8” (64.5 cm)
1 1/4” (3.2 cm) cooking surface
height (grate level) above
countertop
Power cord
3 3/8”
40” long
(8.6 cm)
3/4” NPT gas inlet, connects to regulator
from bottom or rear of unit, end is recessed
2” (5.1 cm) from chassis bottom
PRODUCT DIMENSIONS - SIDE VIEW
All specications subject to change without notice.
Trim:
1/4”
(6.4 mm)
thick
7 3/4”
(19.7 cm)
7/16”
(1.1 cm)
CABINET/COUNTERTOP SIDE VIEW WITHOUT BACKGUARD
Combustible
rear wall
Backguard mandatory if
gap from back of cooktop
to combustible wall is less
than 2 1/2”
CABINET/COUNTERTOP SIDE VIEW WITH BACKGUARD
Phone: (800) 793-0093www.dacor.com
Document # PG04-007
DYRTP366, DYRTP486
Revised 08/15/14 Page 2/4
Discovery 36” and 48” Wide
Slide-in Gas Rangetops
Cabinet tolerances: +1/16” (+1.6 mm), -0 unless otherwise noted.
10” (25.4 cm) to
combustible side
wall min. both sides
CABINET/COUNTERTOP DIMENSIONS - FRONT VIEW
1/2” (1.3 cm)
overhang,
both sides
Mounting platform
1” (2.5 cm) min.
thickness
13” (33.0 cm)
max.
PLANNING
GUIDE
1 1/2” (3.8 cm)
typical countertop
thickness
B
Recommended
gas and electrical
service location,
consult local code
3
7 3/4”
(19.7 cm)
36” (91.4 cm)
typical
15” (40.6 cm)
1, 3
min.
Grate
level
Top of
finished
counter
C
30” (76.2 cm)
min.
1
Cutout for
utility access
Grate
level
See note 2
Model No. B C
DYRTP366 36” (91.4 cm)
DYRTP486 48” (121.9 cm)
* Minimum ** Recommended
CABINET/COUNTERTOP DIMENSIONS -
ISO VIEW
36” (91.4 cm)*
42” (106.7 cm)**
48” (121.9 cm)*
54” (137.2 cm)**
1
Vertical to combustible surface from rangetop grate level;
if installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
2
See Cabinet/Countertop Dimensions - Top View
3
This specification not applicable for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
All specications subject to change without notice.
continued on following pages...