DHW Hoods
Chimney
24”
Min. 30” - Max. 42”
24” - 36” - 42” - 48”
15”
11 3/4”
5 3/4”
12 1/2”
16 1/4” *
24 3/4”
Document # PG07 - 001
30”, 36”, 42” and 48” Wide
Wall Mount Chimney Hoods
All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
Revised 10/21/09 Page 1/1
PLANNING
GUIDE
WARNING
Observe all governing codes and ordinances during planning •
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the •
accompanying installation instructions.
DO NOT install an additional in-line or external blower to •
increase the length of the duct run. Even small differences
between blower air flow rates can greatly reduce the air draw
of the hood.
Chimney can accommodate up to 10” round duct work◊
Unit can be installed to exhaust through the ceiling or through the rear ◊
wall (see diagram above).
Blower
Blower speeds 4
Lights 12 Vac, 20 Watt halogen
Filters Bafe type, dishwasher safe
Exhaust 8 inch
Finish 430 stainless steel
Total connected
load
Circuit
requirements
* At zero inches static pressure
Blowers 1 1 1 2
Lights 2 2 3 4
Filters 1 1 1 2
Maximum
current draw
* 18” 1/4 on 48 inch model (DHW482)
DHW SERIES OVERALL DIMENSIONS
600 CFM* (1200 CFM* for units with 2 blowers)
with electronic speed control
120 Vac, 60 Hz. (see table at right for current
rating)
120 Vac, 15 Amp. grounded, dedicated 3-wire
circuit (hot, neutral, ground)
GENERAL SPECIFICATIONS
MODEL NUMBER
DHW301 DHW361 DHW421 DHW482
3.4 Amp. 3.4 Amp. 3.6 Amp. 6.8 Amp.
REAR EXHAUST DIAGRAM
IMPORTANT: The minimum installed distance from the hood to the cooking
surface must be no less than 30 inches. The minimum specified distance
may be higher for the particular range or cooktop in use. Check the
manufacturers specifications for the cooktop or range.
Maximum Duct Length
The maximum straight duct length for the hood is 50 feet. To determine the
actual maximum duct run, subtract the equivalent length of each elbow,
transition and cap from 50 feet. See the Duct Planning Guide or the
installation instructions for more details.
MODEL SPECIFIC SPECIFICATIONS
www.Dacor.com
Phone: (800) 793-0093
Specications are subject to change without notice.
See installation instructions for additional details.
7.1