Dacor DHICH Planning Guide

Document # PG07-002
28” (71.1 cm) to 36” (91.4 cm)
DHI
Revised 09/22/14 Page 1/1
Discovery® 36”, 42”, 48” and 54” Wide
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
• DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences
between blower air flow rates can greatly reduce the air draw
of the hood.
Blower
Blower Speeds 4
Lights 12 Vac, 20 Watt halogen
Filters Bafe type, dishwasher safe
Exhaust 8 Inch
Finish 430 stainless steel
Total connected
load
Circuit
requirements
* At zero inches static pressure
600 CFM* (1200 CFM* for units with 2 blowers) with electronic speed control
120 Vac, 60 Hz (see table at right for current rating)
120 Vac, 15 Amp. grounded, dedicated 3-wire circuit (hot, neutral, ground)
GENERAL SPECIFICATIONS
PLANNING
GUIDE
All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
15 ¾” (40.0 cm)
Chimney
12 ½”
15 ½”
Chimney can accommodate up to 10” round duct work
(31.8 cm)
(39.4 cm)*
* 18” 1/4 on models DHI482 and DHI542
DHI SERIES OVERALL DIMENSIONS
12 9/16” (31.9 cm)
36” (91.4 cm) - 42” (106.7 cm) 48” (121.9 cm) - 54” 137.2 cm)
30” (76.2 cm)
Model** Blowers Lights Filters
DHI361 1 4 1 3.8 Amp.
DHI421 1 4 1 3.8 Amp.
DHI482 2 4 2 6.8 Amp.
DHI542 2 6 2 7.1 Amp.
MODEL SPECIFIC SPECIFICATIONS
** IMPORTANT ORDERING INFORMATION: Each model
requires that you order a chimney assembly (Part number DHICH) in addition to the hood assembly part number.
Maximum Current
Draw
Maximum Duct Length
The maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details.
IMPORTANT: The minimum installed distance from the hood to the cooking
surface must be no less than 30 inches. The minimum specified distance
may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.
Optional Recirculation Kit (PN AVDI1/AVDI2)
Converts hood to a recirculating configuration in instances where exhausting the hood outside the building is not practical or desired. Consists of a top cap and 2 charcoal filters. When installed, the top cap redirects air flow out the vents in the sides of the hood
chimney assembly. The provided
charcoal filters are installed
underneath the mesh type filters
included with the hood. The
charcoal filters reduce smoke and
fumes before the hood exhaust is vented into the room. Requires 20 inch long piece of 8 inch round duct (not included).
Top cap
8 inch duct
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com