Cub Cadet 2004701 User Manual

Electric, Spot-Sprayer Parts List
02004701 25-Gallon, 1/4" x 25' FlexCoil Hose
3/8 hose
18.0" LG.
3/8 hose each
14.0" LG.
3/8 hose
5.0" LG.
3/8 hose: 2.0" LG. Run Blue Hose through this piece and mount to tank along with harness using 1/2" conduit strap
Starting Date: 8/2007 –
Ref.
No.
Part No. Description Qty.
Ref.
No.
Part No. Description Qty.
00032615 Wire, 16-3 10ft. 15 00035626 Hose Barb, 3/8" x 90° Male Elbow 1 00032630 Shrink Tube, 3/8" 4in. 16 00035627 Hose Barb, 3/8 Nylon 2
00005173 Strainer 1 18 00035631 Hose Barb, 3/8 x 3/8 MPT 1 4 00020851 Diaphragm Pump, Flojet 1 19 00035678 Mach. Screw, # 10-24 x 3/4 Pan Hd. 4 5 -- Hose, 3/8” 3 20 00035781 Hose Barb, 3/8 x 1/4 MPT 2 6 00031247 Valve, 90°, 1/4 FPT 1 21 00035790 Conduit Strap, 1/2 1 7 00032078 Nipple, 3/8 MPT Close 1 22 00035816 Hose, 1/4" x 25', FlexCoil 1 8 00032081 Tee, 3/8 FPT Brass 1 00034896 3/8 Hose, Reinforced PVC-25 ft. 1 9 00032086 Fitting, Adapter, 1/4 MPT x 11/1 61 1 23 01000215 Hose Clamp 8
10 00032113 Elbow, 90°, 1/4 MPT x 3/8 Hose Barb 1 24 01006835 Tank, 25 Gallon, Polyethylene includes: 1 11 00034947 Cap Screw, 5/16-18 x 1/2 Hex Hd. 1 01007969 Tank Lid 1 12 00035599 Fitting, Adapter 1
Electric, Spot-Sprayers
Operating Instructions
After Filling Tank: (Note: We recommend the use of liquid products only.)
1. Connect power cord red cable to positive and black cable to negative 12 volt DC power source.
2. Turn pump power switch to "on".
3. Remove tank lid. Hold TriggerJet™ wand with nozzle pointing into fillwell. Squeeze wand trigger allowing spray liquid to recirculate back into tank until air is purged from hoses. Release pressure on trigger, remove wand from fillwell and replace lid. You are now ready to spray.
4. Closing the 1/4" Bypass Valve stops tank agitation. Opening the valve allows tank agitation through the bypass hose. The wand output can be regulated by adjusting the Bypass Valve.
Adjusting Wand Tip:
1. The knurled body of the tip rotates a half turn to provide spray selection from a wide angle, finely atomized cone spray to a straight stream spray.
Should Pump Fail to Run:
1. Check pump switch and power source connections.
2. Check 10 amp fuse in power cord.
3. Check internal pump parts for needed repairs.
Pump Runs - No Fluid:
1. Remove tank lid. Hold TiggerJet™ wand with nozzle pointing into fillwell. Squeeze wand trigger and hold until pump primes. Allow spray liquid to recirculate into tank until air is purged from hoses.
2. Check suction line inside tank and make certain it is not pinched or plugged.
3. Turn pump switch to "off" and check for clogged suction strainer at pump inlet. Remove swivel hose fitting from strainer cap and remove strainer cap (one-quarter turn counter­clockwise). Remove screen and clean.
Form No. 02004720 Rev. 08-0 7/26/2007 TriggerJet is a trademark of Spraying Systems Co.
Loading...