CTEK PRO25S Service Manual

MANUAL
CONGRATULATIONS
on the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest technology in battery charging.
Read safety instruction
HOW TO CHARGE
1. Connect the charger to the battery.
Temperature sensor The temperature sensor works automatically and will adjust the voltage to the ambient temperature. Place the temperature sensor in the positive clamp or as the close to the battery as possible.
+
For batter ies moun ted inside a ve hicle
1. Connec t the charger according to the vehicles manual.
1 2
2. Connect the charger to the wall socket. The power lamp will indicate that the mains cable is connected to the wall socket. The error lamp will indicate if the battery clamps are incorrectly connected. The reverse polarity protection will ensure that the battery or charger will not be damaged.
2. Connect the charger to the wall socket.
3. Disconnect the charger from the wall socket before disconnecting the battery.
4. Disconnect the black clamp before the red clamp.
3. Press the MODE-button to select charging program.
4. Follow the indication lamps through the charging process. The battery is ready to start the engine when is lit. The battery is fully charged when is lit.
5. Stop charging at any time by disconnecting the mains cable from the wall socket.
ERROR
LAMP
MODE-
BUTTON
POWER
LAMP
NORMAL
BATTERY
PROGRAM
CHARGING
EMPTY
MODE
LITHIUM
PROGRAM
READY TO USE
FULLY CHARGED
RECONDSUPPLYNORMAL LITHIUM
SUPPLY
PROGRAM
RECOND
PROGRAM
EN • 5
PRO25S
RECONDSUPPLYNORMAL LITHIUM
PRO25S
LEAD -ACID
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger activates the selected program. The selected program will be restarted next time the charger is connected.
The table explains the different Charging Programs:
Program Explanation
NORMAL
RECOND
SUPPLY
Normal battery program 14.4V/25A. Only for lead-acid batteries.
Recond program 15. 8V/1.5A Use Recond to return energy to empty WET and Ca/Ca batteries. Recond your battery once per year and after deep dischare to maximise lifetime and capacity. The Recond program adds the Recond step to the normal battery program. Only for lead- acid batteries.
Supply program 13.6V/25A Use as a 12V power supply or use for float maintenance charging when 100% capacity of the battery is required. The Supply program activates the Float step without time or voltage limitation. The spark protection on the battery charger is disabled during the SUPPLY program.
READY TO USE
The table shows the estimated time to charge a battery from empty to 80%
BATTERY SIZE (Ah)
40Ah 100Ah 200Ah 300Ah
TIME TO 80% CHARGED
1.5h 3h 6h
16h
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT:
The charger has entered the energy save mode. This happens if the charger isn´t connected to the battery within 2 minutes or the battery voltage is below 2V.
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers red clamp connected to the battery's positive pole? Connect the charger according to the vehicles manual.
2. Is the charger connected to a 12V battery?
3. Are the clamps short circuited?
4. Has charging been interrupted in or ?
Restart the charger by pressing the MODE-button. If charging is still being interrupted, the battery...
...is seriosly sulphated and may need to be replaced. ...can not accept charge and may need to be replaced. ...can not keep charge and may need to be replaced.
6 • EN
Loading...