to the purchase of your new professional switch mode battery charger.
This charger is included in a series of professional chargers from
CTEK SWEDEN AB and represents the latest technology in battery
charging. MXTS 70 is the first charger with multiple adjustable parameters.
SAFETY
•THE CHARGER IS DESIGNED FOR CHARGING ONLY FOR BATTERIES ACCORDING TO
THE TECHNICAL SPECIFICATION. DO NOT
USE THE CHARGER FOR ANY OTHER PURPOSE. ALWAYS FOLLOW BATTERY MANUFACTURERS RECOMMENDATIONS.
•NEVER TRY TO CHARGE NON RECHARGEABLE BATTERIES.
•CHECK THE CHARGER CABLES PRIOR TO
USE. ENSURE THAT NO CRACKS HAVE
OCCURRED IN THE CABLES OR IN THE
BEND PROTECTION. A CHARGER WITH
DAMAGED CORD MUST BE RETURNED
TO THE RETAILER. A DAMAGED MAINS
CABLE MUST BE REPLACED BY A CTEK
REPRESENTATIVE.
•NEVER CHARGE A DAMAGED BATTERY.
•NEVER CHARGE A FROZEN BATTERY.
•NEVER PLACE THE CHARGER ON TOP OF
THE BATTERY WHEN CHARGING.
•ALWAYS PROVIDE FOR PROPER VENTILATION DURING CHARGING.
•AVOID COVERING THE CHARGER.
•A BATTERY BEING CHARGED COULD EMIT
EXPLOSIVE GASSES. PREVENT SPARKS CLOSE
TO THE BATTERY. WHEN BATTERIES ARE
REACHING THE END OF THEIR LIFECYCLE
INTERNAL SPARKS MAY OCCUR.
•ALL BATTERIES FAIL SOONER OR LATER. A
BATTERY THAT FAILS DURING CHARGING IS
NORMALLY TAKEN CARE OF BY THE CHARGERS ADVANCED CONTROL, BUT SOME
RARE ERRORS IN THE BATTERY COULD STILL
EXIST. DON’T LEAVE ANY BATTERY DURING
CHARGING UNATTENDED FOR A LONGER
PERIOD OF TIME.
•ENSURE THAT THE CABLING DOES NOT
JAM OR COMES INTO CONTACT WITH HOT
SURFACES OR SHARP EDGES.
•BATTERY ACID IS CORROSIVE. RINSE IMMEDIATELY WITH WATER IF ACID COMES INTO
CONTACT WITH SKIN OR EYES, SEEK IMMEDIATE MEDICAL ADVICE.
•ALWAYS CHECK THAT THE CHARGER HAS
SWITCHED TO STEP 7 BEFORE LEAVING THE
CHARGER UNATTENDED AND CONNECTED
FOR LONG PERIODS. IF THE CHARGER
HAS NOT SWITCHED TO STEP 7 WITHIN
55 HOURS, THIS IS AN INDICATION OF
AN ERROR. MANUALLY DISCONNECT THE
CHARGER.
•BATTERIES CONSUME WATER DURING USE
AND CHARGING. FOR BATTERIES WHERE
WATER CAN BE ADDED, THE WATER LEVEL
SHOULD BE CHECKED REGULARLY. IF THE
WATER LEVEL IS LOW ADD DISTILLED WATER.
•THIS APPLIANCE IS NOT DESIGNED FOR USE
BY YOUNG CHILDREN OR PEOPLE WHO CANNOT READ OR UNDERSTAND THE MANUAL
UNLESS THEY ARE UNDER THE SUPERVISION
OF A RESPONSIBLE PERSON TO ENSURE THAT
THEY CAN USE THE BATTERY CHARGER SAFELY.
THIS APPLIANCE CAN BE USED BY CHILDREN
AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY
OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE
BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE
IN A SAFE WAY AND UNDERSTAND THE
HAZARDS INVOLVED. CHILDREN SHALL NOT
PLAY WITH THE APPLIANCE. CLEANING AND
USER MAINTENANCE SHALL NOT BE MADE
BY CHILDREN WITHOUT SUPERVISION.
•CONNECTION TO THE MAINS SUPPLY
MUST BE IN ACCORDANCE WITH THE
NATIONAL REGULATIONS FOR ELECTRICAL
INSTALLATIONS.
•THE CHARGER MUST ONLY BE CONNECTED
TO AN EARTHED SOCKET OUTLET.
•THE CHARGER IS DESIGNED FOR INDOOR
USE. DO NOT EXPOSE TO RAIN OR SNOW.
EN • 3
20019214A Manual MXTS70, All languages, Print file_003.indd 32013-08-19 13:22:19
USB PORT
ENDEFRESITNLSEDKNOFI
The USB port is used for downloading charge program parameters from a PC by a technician or skilled user
but not end user.
Die USB-Schnittstelle wird für das Herunterladen von Ladeprogrammparametern von einem PC durch einen
Techniker oder einen versierten Anwender, nicht jedoch durch einen Endanwender, verwendet.
Le port USB permet à un technicien ou à un utilisateur expérimenté de télécharger les paramètres des pro
grammes de charge depuis un PC, il n’est pas destiné à l’utilisateur standard.
Un usuario técnico/cualificado (no el usuario final) puede usar el puerto USB para descargar desde un PC
los parámetros del programa de carga.
La porta USB è riservata allo scaricamento dei parametri dei programmi di ricarica da un PC da parte di un
tecnico oppure di un utente esperto, non dell’utente finale.
De USB-poort wordt gebruikt om de parameters van het oplaadprogramma te downloaden vanaf een pc,
door technici of ervaren gebruikers, maar niet door eindgebruikers.
USB-porten används för att ansluta till en PC och hämta parametrar för laddningsprogram, vilket bör göras av
en tekniker eller en van användare, inte en slutkonsument.
-
USB-porten bruges til overførsel af opladningsprogrammets parametre fra en pc, hvilket foretages af en tekni
ker eller superbruger, men ikke slutbrugeren.
USB-porten brukes av en tekniker eller erfaren bruker, men ikke sluttbruker, til nedlasting av parametere for
ladeprogram fra en PC.
USB-porttia käytetään latausohjelman parametrien lataamiseen tietokoneelta. Toimenpiteen saa suorittaa vain
teknikko tai ammattilainen, ei loppukäyttäjä.
-
CORD SET PRO*
CORD SET PRO
female connector +
Temperature sensor
Charger cable
male connector +/-
Eyelets M8
Clamps
Temperature sensor
Temperature sensor female connector
male connector
CORD SET PRO
female connector -
USB Type B contact
Mains cable
Mains cable connector
*Optional
4 • EN
20019214A Manual MXTS70, All languages, Print file_003.indd 42013-08-19 13:22:21
Mains switch
EN
QUICK GUIDE
To charge, with last used program settings
Turn on mains switch
4
5
Press START/STOP-button to
start charging
Press the START/STOP-button
to interrupt charging
1
Attach the cables to
the charger
MOUNTING
When permanently mounting the charger, mount the charger on a firm
surface. Fix the charger with screws in the four holes. Use screws intended
for the surface. Allow space around the charger to not interfere with air
cooling.
MXTS 70
12V/70A
24V/50A
STOP
START
MODE
STOP
NORMAL Ca/Ca BOOSTAGMSUPPLY
1 2 3 4 5 6 7 8
A
Ah & infoVh
SET
CONNECT THE CABLES
If the battery clamps are incorrectly connected, the reverse polarity protection will
ensure that the battery and charger are not damaged.
• Connect the battery cable
, including the temperature sensor, to the
1
charger.
• Connect the mains cable
• Connect the red clamp
• Connect the black clamp
to the charger.
2
to the battery´s positive pole.
3
to the vehicle chassis remote from the fuel
4
pipe and the battery.
• Connect the charger
• Turn on mains switch
to the mains supply.
5
.
6
DISCONNECT THE CABLES
• Turn off mains switch
• Disconnect the charger from the mains supply
battery.
• Disconnect the black clamp
.
6
5
before the red clamp
4
before disconnecting the
.
3
6
USB TYPE B CONTACT
–
+
1
–
2
+
3
Connect
the charger
2
Connect the charger
to the battery
Batteries and electronics will be damaged if 12V batteries
20019214A Manual MXTS70, All languages, Print file_003.indd 52013-08-19 13:22:23
WARNING!
are charged in 24V-setting.
to mains supply*
*Supply plugs may differ to suit your mains supply.
USB TYPE B CONTACT
Used for downloading of customized charging programs.
Contact info@ctek.com for information.
NOTE: Not to be used for mobile phone charging!
READY TO USE
The table shows the estimated time for empty battery to 80% charge
BATTERY SIZE
20Ah 50Ah 100Ah 200Ah 500Ah 1000Ah
10A2h4h8h
20A 2h4h8h
30A2h3h5h
CURRENT
40A2h4h10h
CHARGING
50A 2h3h8h16h
Some vehicles may
have positively
earthed batteries
• Connect the black
clamp
3
to the battery´s
negative terminal.
• Connect the red clamp
to the vehicle chassis
4
remote from the fuel pipe
3
4
and the battery.
Disconnect the cables
• Disconnect the red clamp
before the black
4
clamp
5
.
3
EN • 5
CHARGING
For best possible charging of your batteries the voltage and current is
adjustable. In addition to that temperature compensated charging is
selectable. See below how to set the parameters for customized charging.
1. Connect the charger cables to the charger
(see quickguide)
MXTS 70
12V/70A
24V/50A
2. Connect the charger to the battery
(see quickguide)
3. Connect the charger to the mains supply
The power lamp will indicate that the mains cable is connected to the
mains supply. The error lamp will indicate if the battery clamps are
incorrectly connected. The reverse polarity protection will ensure that
the battery or charger will not be damaged.
4. Turn on the mains switch
5. Press the MODE-button to select charging program
6. Press SET-button to set parameters
7. Select voltage
•Display (h) will indicate that voltage (U) is selectable
•Display (V) will indicate set voltage
•Press +/- to change
•Press SET-button to confirm
8. Select current
•Display (h) will indicate that current (A) is selectable
•Display (A) will indicate set current
•Press +/- to change
•Press SET-button to confirm
9. Select temperature compensation
•Display (h) will indicate that temperature compensation ( ) is selectable
•Temperature sensor lamp will indicate activated temperature sensor
•Press +/- to change
•Press SET-button to confirm
10. Press the START/STOP-button to start charging cycle
or press MODE-button to change charging program
11. Follow the 8-step display through the charging
process
The battery is ready to start the engine when STEP 4 is lit. The battery
is fully charged when STEP 7 is lit.
MODE-BUTTON
START/STOP-BUTTON
NORMAL PROGRAM
AGM PROGRAM
Ca/Ca PROGRAM
BOOST PROGRAM
DISPLAY (V)
DISPLAY (h)
SET-BUTTON
DECREASE BUTTON
START
STOP
NORMALCa/Ca BOOSTAGMSUPPLY
12345678
STOP
V
h
MODE
A
Ah & info
SET
POWER LAMP
ERROR LAMP
TEMPERATUR SENSOR LAMP
SUPPLY PROGRAM
READY TO START
FULLY CHARGED
DISPLAY (A)
DISPLAY (Ah & info)
INCREASE BUTTON
12. Stop charging at any time by pressing the START/
STOP-button
13. Press START/STOP-button to start charging cycle
6 • EN
20019214A Manual MXTS70, All languages, Print file_003.indd 62013-08-19 13:22:23
EN
SUPPLY
For best possible float maintenance charging or voltage supply function
for your vehicle the voltage and max current limit are adjustable from the
front panel. See below how to set the voltage supply program and it's
parameters.
1. Connect the charger cables to the charger
(see "Cable connection")
2. Connect the charger to the battery
(see "Cable connection")
3. Connect the charger to the mains supply
The power lamp will indicate that the mains cable is connected to the
mains supply. The error lamp will indicate if the battery clamps are
incorrectly connected. The reverse polarity protection will ensure that
the battery or charger will not be damaged.
MODE-BUTTON
START/STOP-BUTTON
START
STOP
STOP
MXTS 70
12V/70A
24V/50A
POWER LAMP
ERROR LAMP
TEMPERATUR SENSOR LAMP
MODE
4. Turn on the mains switch
5. Press the MODE-button to select Supply mode
6. Press SET-button to set parameters
7. Select voltage
•Display (h) will indicate that voltage (U) is selected
•Display (V) will indicate set voltage
•Press +/- to change
•Press SET-button to confirm
8. Select Supply voltage
•Display (h) will indicate that Supply voltage (Su) is selected
•Display (V) will indicate Supply voltage level
•Press +/- to change
•Press SET-button to confirm
9. Select current
•Display (h) will indicate that current (A) is selected
•Display (A) will indicate set current
•Press +/- to change
•Press SET-button to confirm
10. Press the START/STOP-button to start Supply mode
11. Supply mode indication
STEP 7 is lit to indicate that Supply mode is running.
12. Stop Supply at any time by pressing the START/
STOP-button
13. Press START/STOP-button to resume Supply mode
NORMAL PROGRAM
AGM PROGRAM
Ca/Ca PROGRAM
BOOST PROGRAM
DISPLAY (V)
DISPLAY (h)
SET-BUTTON
DECREASE BUTTON
NORMALCa/Ca BOOSTAGMSUPPLY
12345678
V
h
SET
A
Ah & info
SUPPLY PROGRAM
READY TO START
FULLY CHARGED
DISPLAY (A)
DISPLAY (Ah & info)
INCREASE BUTTON
EN • 7
20019214A Manual MXTS70, All languages, Print file_003.indd 72013-08-19 13:22:23
INDICATION LAMPS, DISPLAYS
AND ERRORCODES
10-7012/24
E01
E01-E99
INDICATION LAMPS:
START/STOP LAMP
Indicates that charging has not started or has been interrupted.
Press START/PAUSE-button to start/resume.
POWER LAMP
Indicates that mains supply is connected.
ERROR LAMP
Indicates that a fault has occurred.
Se ERROR CODES for description.
Press START/PAUSE-button to clear error and interrupt charging.
TEMPERATURE SENSOR LAMP
Indicates that the temperature sensor is activated.
Voltage is automatically adjusted to optimize charge at
ambient temperature.
SETTINGS BEFORE START:
DISPLAY (V)
Indicates voltage set
Options: 12/24 Volts
DISPLAY (A)
Indicates current set
Options: 70/50/40/30/20/10A in 12V setting
Options: 50/40/30/20/10A in 24V setting
70A could only be selected for SUPPLY program.
DISPLAY (h)
Indicates which parameter to set
Options: U/SU/A/ /
U = Nominal Voltage
SU = Supply Voltage
A = Current limit
= Temperature compensation
= Recond time in BOOST program
DISPLAY (Ah & info)
Displays error codes
REAL TIME INDICATION DURING CHARGING:
DISPLAY (V)
Displays output voltage
DISPLAY (A)
Displays output current
DISPLAY (h)
Alt. 1. Displays total elapsed charging time (minutes/hours)
Alt. 2. Displays time elapsed until error occured
DISPLAY (Ah & info)
Alt.1. Displays total charge delivered since start (minutes/hours)
Alt.2. Displays error codes together with ERROR lamp
ERROR CODES:
E01REVERSE POLARITY
Connect the charger according to “quickguide”
E02 OVER VOLTAGE
Battery voltage to high for the chosen charging program, check
battery voltage.
E03 TIME OUT STEP 1: DESULPHATION
Restart the charger. If charging is still being interrupted the bat-
tery is seriously sulphated and may need to be replaced.
E04 TIME OUT STEP 2: SOFT START
Restart the charger. If charging is still being interrupted the battery
can not accept charge and may need to be replaced.
E05 TIME OUT STEP 5: ANALYSE
Restart the charger. If charging is still being interrupted the bat-
tery can not keep charge and may need to be replaced.
E06 BATTERY OVERHEATED
The battery is too hot to charge. The battery is damaged and
may need to be replaced.
E07LOW BATTERY VOLTAGE IN SUPPLY PROGRAM
Battery voltage too low or too large consumers connected. Check
if 12V battery connected in 24V battery setting or disconnect
large consumers.
E08 HIGH CURRENT IN SUPPLY PROGRAM
Check if clamps are short circuited or connected reversed polarity.
E99 OVER VOLTAGE PROTECTION
If battery voltage is below 17V the ERROR lamp is lit when 24V
Alt 1. Press START/STOP button to charge with 12V setting.
setting has been selected.
To set the parameters for customized charging proceed with
“CHARGING” step 6 to 9
Alt 2. Press INCREASE button to change to 24V setting. Press
START/STOP button to resume. To set the parameters for custom
ized charging proceed with “CHARGING” step 6 to 9.
-
8 • EN
20019214A Manual MXTS70, All languages, Print file_003.indd 82013-08-19 13:22:24
EN
CHARGING PROGRAMS
Choose program by pressing the MODE-button.
Adjust parameters according to "CHARGING" (6–9).
Press START/STOP button to start the selected program.
The table explains the different Charging Programs:
Use for most AGM batteries. Some AGM should use lower voltage
(NORMAL Mode), check battery manual if unsure.
Use for Ca/Ca batteries. Use Ca/Ca program to maximize charge with
minimum loss of fluid. Including RECOND step. Recond your battery once
per year and after deep discharge to maximise lifetime and capacity.
Used for recovery of stratified batteries.
Use as power supply or use for float maintenance charging when 100%
capacity of the battery is required. SUPPLY program activates step 7 without
time or voltage limitation.
ExplanationTemp range
12V/24V
-20°C –+50°C
(-4ºF–+122ºF)
-20°C –+50°C
(-4ºF–+122ºF)
-20°C –+50°C
(-4ºF–+122ºF)
-20°C –+50°C
(-4ºF–+122ºF)
-20°C –+50°C
(-4ºF–+122ºF)
TECHNICAL SPECIFICATION
Model number1045
Rated Voltage AC220–240VAC, 47–64Hz
Charging voltageNormal 14.4V/28.8V
Max15.8V/31.6V
Supply13.6V/27.2V,14.0V/28.0V
14.4V/28.8, 14.8V/29.6V
Start voltage2.0V
Output currentMax 50A; 70A in supply 12V
Current, mainsM a x 7. 2A
(at full charging current in 24V)
rms
Back current drain* <1Ah/mon t h
Ri p ple**<4% of actual DC current
Ambient
temperature
-20°C to +50°C
(-4°F to +122°F)
Charger type 8 step fully automatic charging cycle
Battery typesAll types of 12V and 24V lead-acid batteries
(WET, MF, Ca/Ca, AGM and GEL) Check with
your battery supplier for appropriate charge
information
Battery capacity20Ah–1500Ah
Dimensions338x178x80mm(LxWxH)
Insulation classIP20
Weight3.3kg,withoutcables
Warrenty2 years
*) Back current drain is the current that drains the battery if the charger is not connected
to the mains. CTEK chargers has a very low back current.
**) The quality of the charging voltage and charging current is very important. A high
current ripple heats up the battery which has an aging effect on the positive electrode.
High voltage ripple could harm other equipment that is connected to the battery. CTEK
battery chargers produce very clean voltage and current with low ripple.
check with the manufacturer if uncertain. The main recommendations are
that Gel batteries should be charged in the lower current range, Power
Risk for short circuiting the battery cables. Connect charger cables
to the charger before connecting the battery
WARNING!
AGM’s in the upper range and most other battery types in the mid-range.
Risk for electrical shock if touching positive and negative terminals
20019214A Manual MXTS70, All languages, Print file_003.indd 92013-08-19 13:22:24
WARNING!
when charging
CTEK SWEDEN AB, issues this limited warranty to the original purchaser of
this product. This limited warranty is not transferable. The warranty applies
to manufacturing faults and material defects for 2 years from the date of
purchase. The customer must return the product together with the receipt
of purchase to the point of purchase. This warranty is void if the battery
charger has been opened, handled carelessly or repaired by anyone
other than CTEK SWEDEN AB or its authorised representatives. The
charger is sealed. Removing or damaging the seal will void the warranty.
CTEK SWEDEN AB makes no warranty other than this limited warranty and
is not liable for any other costs other than those mentioned above, i.e. no
consequential damages. Moreover, CTEK SWEDEN AB is not obligated to
any other warranty other than this warranty.
CTEK offers a professional customer support: www.ctek.com.
For latest user manual see www.ctek.com.
By e-mail: info@ctek.com,bytelephone:+46(0)22535180,
Detects sulphated batteries. Pulsing current and voltage, removes sulfates from
the lead plates of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents charging a defect battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need
to be replaced.
STEP 6 RECOND
Choose the Ca/Ca program to add the recondition step to the charging program.
This step can also be selected separately by choosing the BOOST-program. During
the recondition step voltage increases to create controlled gassing in the battery.
Gasing mixes the battery acid and gives back energy to the battery.
STEP 7 FLOAT
This step maintains the battery voltage by providing a constant voltage charge. This
step can also be selected separately by choosing the SUPPLY-program and then it
is possible to select different voltage settings.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery
voltage and gives a pulse when necessary to keep the battery fully charged.
10 • EN
20019214A Manual MXTS70, All languages, Print file_003.indd 102013-08-19 13:22:24
20019214A
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.